Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic filters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Phase Contrast Imaging Diagnostic on DIII-D (1994-2007); Phase Contrast Imaging Diagnostic on DIII-D and Alcator C-Mod (2007-2010); Experimental Study of Waves, Turbulence and Transport, and Model Validation with Phase Contrast Imaging on DIII-D and Alcator C-Mod (2010-2012); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Measuring High-k Turbulence and Alfven modes (2021-2016); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Full Multi-Scale Measurements (2016-2020) (Final Report)

This report describes the first twenty-five years of development and use of the Phase Contrast Imaging (PCI) diagnostic for measuring plasma fluctuations on the DIII–D tokamak. One of the key challenges in moving tokamak technology forward to the stage of a nuclear reactor remains understanding how energy and particles are transported across the magnetic field by the action of turbulence and waves, and PCI provides a highly flexible and capable measurement of these fluctuations. The PCI diagnostic uses a laser beam to probe the plasma and optical filtering to produce an amplitude variation on a linear detector array which provides an image of the density waves in the plasma. The PCI covers an exceptional range in frequency and wavelength of the measured fluctuations, allowing observation of plasma-sized magnetohydrodynamic (MHD) modes and ion- and electron-scale turbulence. Modulation of the beam amplitude allows measurement of radio frequency (RF) waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compensated digital readout family

ISC has completed test on an IC which has 32 channels of amplifiers, low pass anti-aliasing filters, 13-bit analog-to-digital (A/D) converters with non-uniformity correction per channel and a digital multiplexer. The single slope class of A/D conversion is described, as are the unique variations required for incorporation of this technique for use with on-focal plane detector readout electronics. This paper describes the architecture used to implement the digital on-focal plane signal processing functions. Results from measured data on a test IC are presented for a circuit containing these functions operating at a sensor frame rate of 1000 hertz.

Ludwig, David E.↗

A Hot‐Swappable, Fault‐Tolerant, Modular Power Converter System for Solar Photovoltaic Plants

The performance metrics of the state-of-the-art commercial solar inverters, such as system cost, operation and maintenance (O&M) cost, service life, reliability, maintainability, and power density are much lower than the target metrics needed to achieve SunShot’s 2030 levelized cost of energy (LCOE) goals. To overcome the shortcomings of the existing solar inverters, this project proposed a novel Hot-Swappable, Fault-Tolerant, Modular Power Converter (HSFT-MPC) concept for solar photovoltaic (PV) plants and proved the concept through the design, fabrication, and laboratory test validation of a single-phase HSFT-MPC prototype. The HSFT-MPC has the following distinct advantages over the state-of-the-art: 1) elimination of harmonic/ electromagnetic interference (EMI) filter in the inverter stage due to the novel topology, 2) lower system cost and higher power density due to the modular design, elimination of harmonic/EMI filter, and lower cooling requirement, 3) higher efficiency due to lower switching frequencies, 4) higher reliability and longer (50 years) service life due to simpler cooling and fault tolerance capability, 5) easier installation, lower O&M cost, and improved maintainability due to the modular design and hot-swappable power electronic building blocks (PEBBs), and 6) improved manufacturability due to the modular design. This project developed a single-phase HSFT-MPC prototype with 25kW nominal output power, 2.4kV, 60Hz nominal AC output, lower than 5% AC output voltage total harmonic distortion, over 5 kW/L inverter power density, and 99.4% inverter peak efficiency, being tolerant to failure of single and multiple PEBBs, and capable of hot swapping of the failed PEBB(s). The HSFT-MPC enables uninterruptable operation of the solar PV plant when failure of single or multiple PEBBs or PV modules occurs. Compared with the existing solar inverters in the market, the HSFT-MPC is expected to reduce the inverter failure-caused downtime and energy losses of solar PV plants by more than 60% and 50%, respectively. Project findings have been presented at major conferences in the field and published in peer-reviewed papers, which added new knowledge to the field of power electronics for solar PV systems. A minicourse on Solar PV Systems was developed for outreach activities. The minicourse will help attract young individuals to the renewable energy profession which has a significant talent shortage. The HSFT-MPC is expected to overcome all of the shortcomings of the state-of-the-art solar inverters in terms of cost, efficiency, service life, reliability, maintainability, and manufacturability targets needed to achieve SunShot’s 2030 LCOE goals. Therefore, the proposed HSFT-MPC concept has the great potential to disrupt the current solar inverter market. This project created a pathway towards industry adoption of the HSFT-MPC to help achieve 50-year service life solar PV systems. Since the solar PV plants using the HSFT-MPC will feature with higher reliability, longer service life, and easier maintenance, they are particularly useful for the rural areas with underserved populations that demand reliable and affordable clean electricity. The outcomes of the project have the strong potential to address national needs in the field of renewable energy to reduce CO 2 emissions from the electricity sector, reduce imports of energy from foreign sources, and improve energy security, efficiency, and sustainability. Since electricity is used in almost all of society’s sectors, the outcomes of the project will benefit various sectors of society and economy.

14 SOLAR ENERGY↗

Slow control and data acquisition development in the Mu2e experiment

The muon campus program at Fermilab includes the Mu2e experiment that will search for a charged-lepton flavor violating processes where a negative muon converts into an electron in the field of an aluminum nucleus, improving by four orders of magnitude the search sensitivity reached so far.Mu2e’s Trigger and Data Acquisition System (TDAQ) uses {\it otsdaq} solution. Developed at Fermilab, {\it otsdaq} uses the {\it artdaq} DAQ framework and {\it art} analysis framework, for event transfer, filtering, and processing.{\it otsdaq} is an online DAQ software suite with a focus on flexibility and scalability, and provides a multi-user interface accessible through a web browser.A Detector Control System (DCS) for monitoring, controlling, alarming, and archiving has been developed using the Experimental Physics and Industrial Control System (EPICS) open source Platform. The DCS System has also been integrated into {\it otsdaq}, providing a GUI multi-user, web-based control, and monitoring dashboard.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 10 micron heterodyne receiver for ultra high resolution astronomical spectroscopy

An improved CO2 laser heterodyne spectrometer is examined. The present system uses reflective optics to eliminate refocusing at different wavelengths, and the local oscillator is a line-center-stabilized isotopic CO2 laser. A tunable diffraction grating makes possible easy and rapid selection of over 50 transitions per isotope of CO2. The IF (0 to 1.6 GHz) from the HgCdTe photomizer is analyzed by a 128-channel filter bank, consisting of 64 tunable 5-MHz filters and 64 fixed 25-MHz RF filters. These filters provide resolving powers of about 1,000,000 to 10,000,000 and velocity resolution of 50 to 250 m/sec; their output is synchronously detected, integrated, multiplexed and stored in a buffer memory for the desired integration period. Kitt Peak observations show the wide spectral coverage, wide mixer and electronics bandwidth, and high sensitivity of the system.

Buhl, D.↗

Optical Monitoring of Weld Penetration

Robotic welding controlled by reliable, relatively-noise-free optoelectronic unit. Bounding off meniscus of pool of molten metal, laser beam impinges on position-sensitive photodetector. Beam diameter adjusted for width of weld. Optical filters screen out light from arc. Made from small, low-cost components and utilizing optical fibers to conduct signals, system immune to electromagnetic interference common in industrial environments. Aimed for automatic welders, robot welders in particular and also adaptable to other types of welding, including tungsten/inert-gas, laser, and electron-beam techniques.

Maram, J.↗

Phase Detector For Rectangular Waveforms

Phase detector for use with phase-locked-loops, servocontrol, and other electronic circuits designed to avoid disadvantages of other phase detectors. Used with both intermittent and continuous input signals. Circuit offers several advantages; reference signals continuous, burst of few pulses, or single pulse. Circuit "coasts" in absence of reference signal. Generates no steady-state output waveform at lock which makes filtering easier.

Dischert, Robert A.↗

Measuring Neutrino Oscillations in the NOvA and CHIPS Detectors.

NOvA is a long baseline neutrino experiment which uses muon neutrinos produced by the NuMI beam at the Fermi National Accelerator Laboratory to measure muon neutrino disappearance and electron neutrino appearance, among other analyses. The Far/Near Extrapolation analysis framework (FNEX) was used to measure muon neutrino disappearance using the events observed by NOvA while the NuMI beam was in Forward Horn Current configuration (i.e. this analysis uses neutrino data, not antineutrino data). The values of the parameters measured in this analysis are sin 2 θ 23 - 0.499$^{+0.098}_{-0.069}$ and Δm$^2_{32}$ - 2.454$^{+0.108}_{0.119}$ × 10 -3 eV, which is consistent with the results of NOvA’s main muon neutrino disappearance analysis using the experiment’s usual framework, known as CAF. The CHIPS detector is a water Cherenkov detector currently in construction. It will also use the NuMI beam to perform muon neutrino disappearance and electron neutrino appearance analyses. The necessary water clarity for a detector with a diameter of 25 m and a height of 6 m is discussed, as well as the results of testing water filtration systems. The filtration that will be used for the detector is a 10 µm carbon block filter and a 0.5 µm filter in series, with no reverse osmosis or ultraviolet sterilisation being used. This provides an attenuation length of 16.63 ± 0.25 m for light of 532 nm wavelength (green), so light with a wavelength of 405 nm (violet) would have an attenuation length of 133±2 m. The greatest possible distance between a PMT and any point in the detector’s volume is approximately 26 m, so 133 m is sufficient for the detector to measure Cherenkov light produced anywhere in the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinear interactions of electromagnetic waves with a thermally generated cesium plasma.

The interaction of a large‐amplitude disturbing wave with a thermally generated, highly ionized cesium plasma has been investigated using a small‐amplitude sensing wave as a probe. The subsequent interaction between the disturbing and sensing waves is related to the plasma electron temperature. The plasma was contained in a magnetic field of 500–1000 G and had an electron plasma frequency near 10 GHz and an electron gyromagnetic frequency around 2 GHz. The sensing wave was a 10 GHz plane wave of approximately 1.5 mW input power and the disturbing wave was 7.5 GHz plane wave of about 1.2 W peak power. Measurements of the sensing‐wave transmitted power were made using standard microwave techniques. A notch filter in the sensing‐wave receiving circuit reduced the scattered disturbing‐wave interference to an immeasurably low level. Langmuir probes were used to detect disturbing‐wave modulation and to measure plasma temperatures and densities. Measurements of the interaction were correlated with a solution of the Boltzmann transport equation for a perturbed Maxwellian distribution function with binary Coulomb collisions.

Jack G Hewitt, Jr↗

Coaxial charged particle energy analyzer

A non-dispersive electrostatic energy analyzer for electrons and other charged particles having a generally coaxial structure of a sequentially arranged sections of an electrostatic lens to focus the beam through an iris and preferably including an ellipsoidally shaped input grid for collimating a wide acceptance beam from a charged-particle source, an electrostatic high-pass filter including a planar exit grid, and an electrostatic low-pass filter. The low-pass filter is configured to reflect low-energy particles back towards a charged particle detector located within the low-pass filter. Each section comprises multiple tubular or conical electrodes arranged about the central axis. The voltages on the lens are scanned to place a selected energy band of the accepted beam at a selected energy at the iris. Voltages on the high-pass and low-pass filters remain substantially fixed during the scan.

Kelly, Michael A.↗

AlGaN/GaN Core-Shell Nanofin Diodes on Si Substrates for Vertical GaN Electronics

We demonstrate plasma-assisted MBE selective-area growth of GaN/AlGaN core-shell structures on Si(111) as a path to vertical GaN devices. The selective-area growth enables the full vertical and uniform core-shell fin structures to be realized in a continuous growth without breaking vacuum. TEM images and EDS mapping of the core-shell structures show well-aligned crystal structure and sharp heterointerfaces. Dislocation filtering was observed in STEM imaging of the fin structure. P-N junction diodes fabricated with GaN/AlGaN core-shell structures reveal ideality factors as low as 1.5, and the reverse-bias leakage is consistent with trap-assisted space-charge-limited conduction. While practical challenges exist, including material-related leakage, growth-related challenges and optimization, this demonstration of p-n junction by this method may provide a path to vertical Superjunction device concepts in GaN and related materials.

Xiong, Juncheng [University of Notre Dame, IN (Uni↗

Development of Short-Pulse Laser-Based Diagnostics for Pulsed Power-Driven Warm Dense Matter

This report summarizes a research project conducted at the Physics Department’s Zebra Pulsed Power Laboratory (ZPPL) at the University of Nevada Reno, aimed at developing short-pulse laser-based diagnostics to probe pulsed-power-driven warm dense matter. ZPPL combines a MegaAmpere (MA) pulsed power generator, Zebra, and a relativistic intensity, short-pulse laser, Leopard, offering a unique university-scale platform for high energy density physics, laboratory astrophysics, and inertial fusion energy research. The project focused on establishing a hard X-ray radiographic capability using high-intensity, short-pulse laser-generated X-rays to probe warm dense matter created by the Zebra current. Initial experiments produced X-ray radiographs of a static (cold) aluminum wire using silver and gold foil and wire targets, but intense background radiation from Zebra shots overwhelmed the laser-produced X-rays. To mitigate this, a radiationhardened detector housing was designed and implemented. Additional diagnostic, including a filter stack bremsstrahlung spectrometer and an X-ray pinhole camera, were developed to characterize laser-produced hard X-ray spectra and locate hard X-ray sources in the vacuum chamber. These revealed that strong hard X-rays (> 20 keV) originated near the anode cap, bombarded by energetic electrons. Due to laser unavailability during some experiments, detector performance was successfully tested using hard X-ray sources from the Zebra current, demonstrating their readiness for coupled experiments. The project supported one Ph.D. student (Dr. Lei Chen), who conducted experimental and numerical research, and provided training opportunities and data for three undergraduate senior theses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Integrated Imaging Detector of Polarization and Spectral Content

A new type of image detector has been designed to simultaneously analyze the polarization of light at all picture elements in a scene. The Integrated Dual Imaging Detector (IDID) consists of a polarizing beamsplitter bonded to a charge-coupled device (CCD), with signal-analysis circuitry and analog-to-digital converters, all integrated on a silicon chip. It should be capable of 1:10(exp 4) polarization discrimination. The IDID should simplify the design and operation of imaging polarimeters and spectroscopic imagers used, for example, in atmospheric and solar research. Innovations in the IDID include (1) two interleaved 512 x 1024-pixel imaging arrays (one for each polarization plane); (2) large dynamic range (well depth of 10(exp 6) electrons per pixel); (3) simultaneous readout of both images at 10 million pixels per second each; (4) on-chip analog signal processing to produce polarization maps in real time; (5) on-chip 10-bit A/D conversion. When used with a lithium-niobate Fabry-Perot etalon or other color filter that can encode spectral information as polarization, the IDID can collect and analyze simultaneous images at two wavelengths. Precise photometric analysis of molecular or atomic concentrations in the atmosphere is one suggested application. When used in a solar telescope, the IDID will charge the polarization, which can then be converted to maps of the vector magnetic fields on the solar surface.

Rust, D. M.↗

Fully Integrated Ultra-thin Intraoperative Micro-imager for Cancer Detection Using Upconverting Nanoparticles

Abstract Purpose Intraoperative detection and removal of microscopic residual disease (MRD) remain critical to the outcome of cancer surgeries. Today’s minimally invasive surgical procedures require miniaturization and surgical integration of highly sensitive imagers to seamlessly integrate into the modern clinical workflow. However, current intraoperative imagers remain cumbersome and still heavily dependent on large lenses and rigid filters, precluding further miniaturization and integration into surgical tools. Procedures We have successfully engineered a chip-scale intraoperative micro-imager array—without optical filters or lenses—integrated with lanthanide-based alloyed upconverting nanoparticles (aUCNPs) to achieve tissue imaging using a single micro-chip. This imaging platform is able to leverage the unique optical properties of aUCNPs (long luminescent lifetime, high-efficiency upconversion, no photobleaching) by utilizing a time-resolved imaging method to acquire images using a 36-by-80-pixel, 2.3 mm $$\times$$ × 4.8 mm silicon-based electronic imager micro-chip, that is, less than 100-µm thin. Each pixel incorporates a novel architecture enabling automated background measurement and cancellation. We have validated the performance, spatial resolution, and the background cancellation scheme of the imaging platform, using resolution test targets and mouse prostate tumor sample intratumorally injected with aUCNPs. To demonstrate the ability to image MRD, or tumor margins, we evaluated the imaging platform in visualizing a single-cell thin section of the injected prostate tumor sample. Results Tested on USAF resolution targets, the imager is able to achieve a resolution of 71 µm. We have also demonstrated successful background cancellation, achieving a signal-to-background ratio of 8 when performing ex vivo imaging on aUCNP-injected prostate tumor sample, improved from originally 0.4. The performance of the imaging platform on single-cell layer sections was also evaluated and the sensor achieved a signal-to-background ratio of 4.3 in resolving cell clusters with sizes as low as 200 cells. Conclusion The imaging system proposed here is a scalable chip-scale ultra-thin alternative for bulky conventional intraoperative imagers. Its novel pixel architecture and background correction scheme enable visualization of microscopic-scale residual disease while remaining completely free of lenses and filters, achieving an ultra-miniaturized form factor—critical for intraoperative settings.

59 BASIC BIOLOGICAL SCIENCES↗

Visualizing strange metallic correlations in the two-dimensional Fermi-Hubbard model with artificial intelligence

Strongly correlated phases of matter are often described in terms of straightforward electronic patterns. This has so far been the basis for studying the Fermi-Hubbard model realized with ultracold atoms. Here, we show that artificial intelligence (AI) can provide an unbiased alternative to this paradigm for phases with subtle, or even unknown, patterns. Long- and short-range spin correlations spontaneously emerge in filters of a convolutional neural network trained on snapshots of single atomic species. In the less well-understood strange metallic phase of the model, we find that a more complex network trained on snapshots of local moments produces an effective order parameter for the non-Fermi-liquid behavior. We report our technique can be employed to characterize correlations unique to other phases with no obvious order parameters or signatures in projective measurements, and has implications for science discovery through AI beyond strongly correlated systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fiscal Year 2021 Filtration of Hanford Tank 241-AP-107 Supernatant Samples Obtained at Prototypic Tank Level and Filtered at 16 °C

Bench-scale filtration testing of 8.5 liters of supernatant from Hanford waste tank 241-AP-107, chilled to 16 °C, was conducted using a backpulse dead-end filter (BDEF) filtration system equipped with a feed vessel and a Mott inline filter Model 6610 (Media Grade 5) in the hot cells of the Radiochemical Processing Laboratory at Pacific Northwest National Laboratory. This was done to assess the impact of a lower sampling location within the tank as well the lowered filtration temperature on supernatant stability and fouling. The as-received samples were transferred to 1.5-liter poly bottles and held at 16 °C for approximately 1 week prior to filtration. The feed was filtered through the BDEF system at a targeted flux of 0.065 gpm/ft 2 to match the prototypic operation of the TSCR system. During the initial period of filtration, the differential pressure required to effect filtration at 0.065 gpm/ft 2 increased until it reached 2 psid [the Tank Side Cesium Removal (TSCR) action limit] at 26 hours. After this, the filter was backpulsed to dislodge accumulated solids and reduce this pressure differential. An additional eight backpulses were conducted during the initial filtration period; each time, the target pressure was reached sooner than during the previous interval. Volume filtered decreased from 0.9 to 0.03 m 3 /m 2 over the course of 14 processing hours. After the ninth backpulse, the backpulse frequency had become unsustainable, and it was decided to perform an extensive filter cleaning. The filter was cleaned by draining the chilled AP-107 feed into chilled holding containers, introducing 0.1 M NaOH into the feed vessel, and recirculating the NaOH through the system for 20 minutes before allowing the system to soak for 2 hours without temperature control. A measurable decrease in filter resistance during this recirculation indicated that the 0.1 M NaOH was likely dissolving some of the solids that had deposited on the filter. Post cleaning, the filter resistance was effectively restored to initial conditions as the initial transmembrane pressure was restored to original levels. However, resumed processing of the AP-107 feed at 16 °C continued to result in an increased rate of filter resistance. An additional five backpulses were conducted (four during feed processing, one during subsequent cleaning) before the conclusion of the test. Solids concentrated from the backpulse solutions displayed sodium oxalate-type phases, Al-oxides and sodium Al-oxides/carbonates, iron oxides, and Ca-bearing phases (calcite). The scanning electron microscopy analyses also revealed a large distribution of particles, with some particles, notably sodium phosphate dodecahydrate, having diameters close to 0.5 mm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Multiwavelength Search for Intrinsic Linear Polarization in Wolf–Rayet Winds

Wolf–Rayet stars have strong, hot winds, with mass-loss rates at least a factor of 10 greater than their O-star progenitors, although their terminal wind speeds are similar. In this paper, we use the technique of multiband linear polarimetry to extract information on the global asymmetry of the wind in a sample of 47 bright Galactic WR stars. Our observations also include time-dependent observations of 17 stars in the sample. The path to our goal includes removing the dominating component of wavelength-dependent interstellar polarization (ISP), which normally follows the well-known Serkowski law. We include a wavelength-dependent ISP position angle parameter in our ISP law and find that 15 stars show significant results for this parameter. We detect a significant component of wavelength-independent polarization due to electron scattering in the wind for 10 cases, with most WR stars showing none at the ∼0.05% level precision of our data. The intrinsically polarized stars can be explained with binary interaction, large-scale wind structure, and clumping. We also found that 5 stars out of 19 observed with the Strömgren b filter (probing the complex λ4600–4700 emission-line region) have significant residuals from the ISP law and propose that this is due to wind asymmetries. We provide a useful catalog of ISP for 47 bright Galactic WR stars and upper limits on the possible level of intrinsic polarization.

79 ASTRONOMY AND ASTROPHYSICS↗

Laser/Plasma/Chemical-Vapor Deposition Of Diamond

Proposed process for deposition of diamond films includes combination of plasma induced in hydrocarbon feed gas by microwave radiation and irradiation of plasma and substrate by lasers. Deposition of graphite suppressed. Reaction chamber irradiated at wavelength favoring polymerization of CH2 radical into powders filtered out of gas. CH3 radicals, having desired sp3 configuration, remains in gas to serve as precursors for deposition. Feed gas selected to favor formation of CH3 radicals; candidates include CH4, C2H4, C2H2, and C2H6. Plasma produced by applying sufficient power at frequency of 2.45 GHz and adjusting density of gas to obtain electron kinetic energies around 100 eV in low-pressure, low-temperature regime.

Hsu, George C.↗