At least 649 records · Page 36

User's Guide to Pre-Processing Data in Universal Translator 2 for the Energy Charting and Metrics Tool (ECAM)

This document is a user's guide for the Energy Charting and Metrics Tool to facilitate the examination of energy information from buildings, reducing the time spent analyzing trend and utility meter data. This user guide was generated to help pre-process data with the intention of utilizing the Energy Charting and Metrics (ECAM) tool to improve building operational efficiency. There are numerous occasions when the metered data that is received from the building automation system (BAS) isn't in the right format acceptable for ECAM. This includes, but isn't limited to, cases such as inconsistent time-stamps for the trends (e.g., each trend has its own time-stamp), data with holes (e.g., some time-stamps have data and others are missing data), each point in the BAS is trended and exported into an individual .csv or .txt file, the time-stamp is unrecognizable by ECAM, etc. After reading through this user guide, the user should be able to pre-process all data files and be ready to use this data in ECAM to improve their building operational efficiency.

99 GENERAL AND MISCELLANEOUS↗

Potential energy savings benefits and limitations of radiative cooling coatings for U.S. residential buildings

We report radiative coatings are a promising strategy to implement passive cooling that provides an eco-friendly pathway to achieve energy efficiency in buildings. This study investigates the benefits and limitations of implementing radiative coatings on the building envelope, particularly the roof, of residential buildings in the United States. The analysis compares the performance of an ideal radiative coating with broadband surface properties to a realistic radiative coating with diffuse and semitransparent properties. To enhance the net energy efficiency of buildings, we carried out a comprehensive parametric analysis comprising key radiation surface properties to maximize cooling energy savings while minimizing heating energy penalties. A countrywide assessment for 68 locations across the United States showed that net energy savings are a strong function of the climatic and atmospheric conditions. Broadly, southern locations showed high overall energy savings whereas northern locations exhibited high overall energy penalties. Locations in International Energy Conservation Code (IECC) climate zones 1A, 2A, and 2B showed a net annual energy savings above 5%, whereas locations in IECC climate zones 5B, 6B, and 7 showed a net annual energy penalty greater than 3%. The hot and dry climate of Phoenix, Arizona, showed the highest overall energy savings of 426 kWh (6.2%). Additionally, the mathematical correlation reveals that the net energy savings of a location is positive only when its average cooling degree days is greater than 5.5 or its average heating degree days is less than 10.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Conditioning with Magnetic Refrigeration : An Efficient, Green Compact Cooling System Using Magnetic Refrigeration

BEETIT Project: Astronautics is developing an air conditioning system that relies on magnetic fields. Typical air conditioners use vapor compression to cool air. Vapor compression uses a liquid refrigerant to circulate within the air conditioner, absorb the heat, and pump the heat out into the external environment. Astronautics’ design uses a novel property of certain materials, called “magnetocaloric materials”, to achieve the same result as liquid refrigerants. These magnetocaloric materials essentially heat up when placed within a magnetic field and cool down when removed, effectively pumping heat out from a cooler to warmer environment. In addition, magnetic refrigeration uses no ozone-depleting gases and is safer to use than conventional air conditioners which are prone to leaks.

ARPA-E↗

Elastic Metal Alloy Refrigerants: Thermoelastic Cooling

BEETIT Project: UMD is developing an energy-efficient cooling system that eliminates the need for synthetic refrigerants that harm the environment. More than 90% of the cooling and refrigeration systems in the U.S. today use vapor compression systems which rely on liquid to vapor phase transformation of synthetic refrigerants to absorb or release heat. Thermoelastic cooling systems, however, use a solid-state material—an elastic shape memory metal alloy—as a refrigerant and a solid to solid phase transformation to absorb or release heat. UMD is developing and testing shape memory alloys and a cooling device that alternately absorbs or creates heat in much the same way as a vapor compression system, but with significantly less energy and a smaller operational footprint.

ARPA-E↗

Efficiency and Demand Flexibility in Large Office Buildings

Data is associated with Report "Efficiency and Demand Flexibility in Large Office Buildings" by Joyce McLaren, Thomas Bowen, and Chioke Harris ( https://doi.org/10.2172/1989231 ). Results are created from repos GEB_ECM_Impact_Estimator ( https://github.nlr.gov/tbowen/GEB_ECM_Impact_Estimator ). Results outline the changes in building load in large office buildings based on measures from NREL's Scout, and the impacts those changes in load have on grid-induced emissions, grid operating costs, and customer bills.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improved Design of Motors for Increased Efficiency in Residential Commercial Buildings

Research progress on understanding magnetic steel core losses is presented in this report. Three major aspects have been thoroughly investigated: 1, experimental characterization of core losses, 2, fundamental physical understanding of core losses and development of core loss formulas, and 3, design of more efficient machine based on the new formulations. Considerable progress has been achieved during the four years of research and the main achievements are summarized in the following: For the experimental characterization, a specially designed advanced commercial test bench was commissioned in addition to the development of a laboratory system with advanced capabilities. The measured properties are core losses at low and higher frequencies, with sinusoidal and non-sinusoidal excitations, at different temperatures, with different measurement apparatus (Toroids, Epstein etc). An engineering-based core loss formula has been developed which considers skin effect. The formula can predict core losses for both sinusoidal and non-sinusoidal flux densities and frequencies up to 4000 Hz. The formula is further tested in electric machines. The formula error range is 1.1% - 7.6% while the standard formulas can have % errors between -8.5% {-+} 44.7%. Two general core loss formulas, valid for different frequencies and thickness, have been developed by analytically and numerically solving Maxwell's equations based on a physical investigation of the dynamic hysteresis effects of magnetic materials. To our knowledge, they are the first models that can offer accurate core loss prediction over a wide range of operating frequencies and lamination thicknesses without a massive experimental database of core losses. The engineering core loss formula has been used with commercial software. The formula performs better than the modified Steinmetz and Bertotti's model used in Cedrat/Magsoft Flux 2D/3D. The new formula shows good correlation with measured results under both sinusoidal and non-sinusoidal excitations. A permanent magnet synchronous motor has been designed with the use of the engineering formula with Flux2D. There was acceptable agreement between predictions and measurements. This was further tested on an induction motor with toroid results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency Potential in Existing Commercial Buildings: Review of Selected Recent Studies

This report reviews six recent studies (from 2002 through 2006) by states and utilities to assess the energy saving potential in existing commercial buildings. The studies cover all or portions of California, Connecticut, Vermont, Colorado, Illinois, and the Pacific Northwest. The studies clearly reveal that lighting remains the single largest and most cost effective end use that can be reduced to save energy. Overall the study indicated that with existing technologies and costs, a reasonable range of economic savings potential in existing commercial buildings is between 10 and 20 percent of current energy use. While not a focus of the study, an additional conclusion is that implementation of commercial building monitoring and controls would also play an important role in the nation’s efforts to improve energy efficiency of existing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Are Deep Energy Retrofits in Commercial Buildings Including Window Upgrades?

U.S. Commercial buildings account for about 20% of total U.S. energy consumption. Because the thermal performance of windows significantly affects building energy efficiency and HVAC system performance, best practice guidance often includes window and envelope improvements in conjunction with HVAC upgrades to optimize energy use and improve occupant comfort. It is an open question, however, regarding how often these best practices are implemented in the field. This paper aims to address that gap by conducting a literature review and a series of interviews with commercial building auditing and management professionals to explore the factors that drive window retrofits in commercial buildings. The paper explores a range of case studies from deep energy retrofits across the globe, comparing projects with and without window retrofits. The primary goals of this review are to: (1) provide data from real-world case studies illustrating the role of windows in deep energy renovations and HVAC upgrades, (2) conduct retrofit cost analyses for windows and high-performance HVAC systems and (3) offer insights into how window upgrade decisions are made and when they are implemented as part of deep energy retrofits. Most of the retrofit studies focused exclusively on high performance HVAC upgrades without considering how window upgrades might further enhance the overall energy efficiency of commercial buildings. Interviews with building industry experts shed light on the key factors influencing deep energy retrofit decisions and what factors tip the scales in favor of including window measures with more comprehensive retrofit projects.

Cort, Katherine↗

A VLSI decomposition of the deBruijn graph

A new Viterbi decoder for convolutional codes with constraint lengths up to 15, called the Big Viterbi Decoder, is under development for the Deep Space Network. It will be demonstrated by decoding data from the Galileo spacecraft, which has a rate 1/4, constraint-length 15 convolutional encoder on board. Here, the mathematical theory underlying the design of the very-large-scale-integrated (VLSI) chips that are being used to build this decoder is explained. The deBruijn graph B sub n describes the topology of a fully parallel, rate 1/v, constraint length n+2 Viterbi decoder, and it is shown that B sub n can be built by appropriately wiring together (i.e., connecting together with extra edges) many isomorphic copies of a fixed graph called a B sub n building block. The efficiency of such a building block is defined as the fraction of the edges in B sub n that are present in the copies of the building block. It is shown, among other things, that for any alpha less than 1, there exists a graph G which is a B sub n building block of efficiency greater than alpha for all sufficiently large n. These results are illustrated by describing a special hierarchical family of deBruijn building blocks, which has led to the design of the gate-array chips being used in the Big Viterbi Decoder.

Collins, O.↗

xSDK: Building an ecosystem of highly efficient math libraries for exascale

Current efforts to build increasingly powerful computer architectures are opening up new avenues for more complex and higher fidelity simulations coupled with data analytics and learning, leading to new scientific insights and deeper understanding. At one extreme, exascale computers will be much faster than previous computer generations (performing 10 18 operations per second—that is, 1,000 times faster than petascale). To achieve these performance improvements, computer architectures are becoming increasingly complex, with deep memory hierarchies, very high node and core counts, and heterogeneous features such as graphics processing units (GPUs). Such architectural changes impact the full breadth of computing scales, as heterogeneity pervades even current-generation laptops, workstations, and moderate-sized clusters. While emerging advanced architectures provide unprecedented opportunities, they also present significant challenges for developers of scientific applications, such as multiphysics and multiscale codes, who must adapt their software to handle disruptive changes in architectures and new programming models that have not yet stabilized. Developers must consider increasing concurrency while reducing communication and synchronization, and other complexities such as the potential for using mixed precision to leverage the compute power available in low-precision tensor cores. On one hand, developers must implement new scientific capabilities, which in turn increase code complexity. On the other hand, the codes must be ported to new architectures, requiring the inclusion of new programming models and the restructuring of code to achieve good performance. Addressing these issues is beyond the capability of any single person or team—leading to the need for collaboration among many teams, who encapsulate their expertise in reusable software and work together to create sustainable software ecosystems.

97 MATHEMATICS AND COMPUTING↗

Implementing High-Efficiency Rooftop Units in Leased Buildings

This case study details a project completed by Efficiency Vermont to install 66 high-efficiency rooftop unit replacements on a large 140,000-square-foot office building, which realized 163 kW in electricity demand reduction and $93,000 annual utility cost savings.

utility, project financing, office building, comme↗

Residential Building Stock Characterization in Palm Beach County, Florida

This building stock characterizations is intended to help Palm Beach County (PBC) Office of Resilience (OOR) and municipalities composing the Municipal Resilience Partnership prioritize building energy efficiency investments to reduce energy costs and increase resilience for the county's most vulnerable residents. The analysis utilizes NREL’s ResStock model to characterize PBC’s residential building stock, including building type, renter/owner status, size (square footage), age of buildings (vintage), HVAC system types, and, for multi-family buildings, number of units. Building energy efficiency, weatherization, and electrification upgrade packages were assessed for approximate cost, customer bill-savings, and emissions reductions potential and findings will help guide OOR financial assistance program design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of radiant cooling system integrated with cooling tower for composite climatic conditions

Increased demand for cooling leads to consumption of a significant amount of energy by heating, ventilation, and air conditioning (HVAC) systems in buildings. Building envelope acts as a thermal barrier and plays a significant role in improving building energy efficiency. Radiant cooling systems often utilize building structure in the form of thermal storage and provide thermal comfort. The radiant cooling system has the potential of saving peak power in the buildings. In present study experimental and a simulation study is performed for chiller and cooling tower integrated chilled ceiling radiant cooling system for chilled water source and a parallel dedicated outdoor air system (DOAS) is used for providing latent load and fresh air requirements of the zone. Cooling tower based radiant cooling system is compared with a chiller-based radiant cooling system for achieving annual energy saving. Experiments are conducted for the chiller and cooling tower operated radiant cooling system. Based on experimental data, whole building simulation models of both cooling tower and chiller-based systems were calibrated. For both the simulation model of chiller and cooling tower operated radiant cooling system simulation were carried out for round the year. The annual simulation results show that the cooling tower operated radiant cooling system saves 14% energy as compared to the chilled water operated radiating cooling system.

Srivastava, Prateek↗

Low-Cost Bio-Based Phase Change Materials as an Energy Storage Medium in Building Envelopes

A promising approach to increasing the energy efficiency of buildings is the implementation of phase change material (PCM) in building envelope systems. Several studies have reported the energy saving potential of PCM in building envelopes. However, wide application of PCMs in building applications has been inhibited, in part, by their high cost. This article describes a novel paraffin product made of naturally occurring fatty acids/glycerides trapped into high density polyethylene (HDPE) pellets and its performance in a building envelope application, with the ultimate goal of commercializing a low-cost PCM platform. The low-cost PCM pellets were mixed with cellulose insulation, installed in external walls and field-tested under natural weatherization conditions for a period of several months. In addition, several PCM samples and PCM-cellulose samples were prepared under controlled conditions for laboratory-scale testing. The laboratory tests were performed to determine the phase change properties of PCM-enhanced cellulose insulation both at microscopic and macroscopic levels. This article presents the data and analysis from the exterior test wall and the laboratory-scale test data. PCM behavior is influenced by the weather and interior conditions, PCM phase change temperature and PCM distribution within the wall cavity, among other factors. Under optimal conditions, the field data showed up to 20% reduction in weekly heat transfer through an external wall due to the PCM compared to cellulose-only insulation.

low-cost PCM↗

Energy efficiency outlook in China’s urban buildings sector through 2030

Here, this study uses bottom-up modeling framework in order to quantify potential energy savings and emission reduction impacts from the implementation of energy efficiency programs in the building sector in China. Policies considered include (1) accelerated building codes in residential and commercial buildings, (2) increased penetration of district heat metering and controls, (3) district heating efficiency improvement, (4) building energy efficiency labeling programs and (5) retrofits of existing commercial buildings. Among these programs, we found that the implementation of building codes provide by far the largest savings opportunity, leading to an overall 17% reduction in overall space heating and cooling demand relative to the baseline. Second are energy efficiency labels with 6%, followed by reductions of losses associated with district heating representing 4% reduction and finally, retrofits representing only about a 1% savings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Design, Development and Testing Plan for Energy Efficiency Algorithms Related to Building-Integrated Cooling, Heating, and Power Systems

Building-integrated cooling, heating and power (CHP) systems are more efficient than conventional systems at providing local power and thermal energy, and favorable fuel prices are bound to spur their increased adoption. It is estimated that the total CHP technical potential in the commercial building sector is approximately 76 GW, but only a small fraction of it is actually deployed. Advanced control and monitoring systems that realize the full potential of these CHP systems can transform this capacity into an asset for both the owner and the grid and also accelerate the adoption of these systems in the building sector. However, to realize the full benefit of the CHP systems, we must ensure persistence of energy efficient operations. It has been demonstrated by several studies that as much as 30% of building energy use is wasted. Much of the waste results from the inability to anticipate load variations (design day vs. non-design day operations; diurnal variation of loads), identify improper operation, and efficiently operate, control and maintain building systems. Moreover, many buildings, even those with adequate control infrastructure, lack knowledgeable staff to operate and maintain energy systems. Operators of buildings with CHP systems will constantly need to make tradeoffs (economic dispatch) between onsite power generation and purchasing power, between onsite heat production from distributed generation versus heating/cooling from conventional systems, and different passive and active load management measures. Much of the inefficiency in the current building operations can be eliminated by use of automated performance monitoring (PM), real-time commissioning verification (CxV) and automated fault detection and diagnostic (AFDD) tools. Automation can help system operators make intelligent decisions. Remote and continuous monitoring of system conditions and performance will enable better management and integration of CHP with existing building systems. Continuous PM, real-time CxV and AFDD could alleviate burdens for operations staff, enhance operations and maintenance (O&M), and improve reliability of building and CHP systems. To address the O&M challenges and to provide a means to maximize the rate-of-return of building-integrated CHP systems, the Building Technologies Office (BTO) within the U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) initiated a project to design, develop, and field test a VOLTTRON™-based supervisory controller and associated open-source algorithms. These algorithms will ensure real-time optimal operation of a building-integrated CHP system, support electric grid reliability, and lead to achieving the goal of a clean, efficient, reliable and affordable next-generation integrated energy systems. This report lists the components for which PM, real-time CxV and AFDD algorithms will be developed, how the algorithms will be tested, and metrics that will be used to validate the algorithms and easy of deployment. Deployment of these algorithms in the field will result in savings reduction in energy consumption of between 10% and 20%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of Energy Savings Potential from the Use of Demand Control Ventilation Systems in General Office Spaces in California

Demand controlled ventilation (DCV) was evaluated for general office spaces in California. A medium size office building meeting the prescriptive requirements of the 2008 California building energy efficiency standards (CEC 2008) was assumed in the building energy simulations performed with the EnergyPlus program to calculate the DCV energy savings potential in five typical California climates. Three design occupancy densities and two minimum ventilation rates were used as model inputs to cover a broader range of design variations. The assumed values of minimum ventilation rates in offices without DCV, based on two different measurement methods, were 81 and 28 cfm per occupant. These rates are based on the co-author's unpublished analyses of data from EPA's survey of 100 U.S. office buildings. These minimum ventilation rates exceed the 15 to 20 cfm per person required in most ventilation standards for offices. The cost effectiveness of applying DCV in general office spaces was estimated via a life cycle cost analyses that considered system costs and energy cost reductions. The results of the energy modeling indicate that the energy savings potential of DCV is largest in the desert area of California (climate zone 14), followed by Mountains (climate zone 16), Central Valley (climate zone 12), North Coast (climate zone 3), and South Coast (climate zone 6). The results of the life cycle cost analysis show DCV is cost effective for office spaces if the typical minimum ventilation rates without DCV is 81 cfm per person, except at the low design occupancy of 10 people per 1000 ft{sup 2} in climate zones 3 and 6. At the low design occupancy of 10 people per 1000 ft{sup 2}, the greatest DCV life cycle cost savings is a net present value (NPV) of $0.52/ft{sup 2} in climate zone 14, followed by $0.32/ft{sup 2} in climate zone 16 and $0.19/ft{sup 2} in climate zone 12. At the medium design occupancy of 15 people per 1000 ft{sup 2}, the DCV savings are higher with a NPV $0.93/ft{sup 2} in climate zone 14, followed by $0.55/ft{sup 2} in climate zone 16, $0.46/ft{sup 2} in climate zone 12, $0.30/ft{sup 2} in climate zone 3, $0.16/ft{sup 2} in climate zone 3. At the high design occupancy of 20 people per 1000 ft{sup 2}, the DCV savings are even higher with a NPV $1.37/ft{sup 2} in climate zone 14, followed by $0.86/ft{sup 2} in climate zone 16, $0.84/ft{sup 2} in climate zone 3, $0.82/ft{sup 2} in climate zone 12, and $0.65/ft{sup 2} in climate zone 6. DCV was not found to be cost effective if the typical minimum ventilation rate without DCV is 28 cfm per occupant, except at high design occupancy of 20 people per 1000 ft{sup 2} in climate zones 14 and 16. Until the large uncertainties about the base case ventilation rates in offices without DCV are reduced, the case for requiring DCV in general office spaces will be a weak case.