Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamic temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Pressure measurement at low temperatures

The present discussion centers on the following topics: (1) what types of pressure transducers show good potential for cryogenic use; (2) what are the output characteristics (stability, sensitivity, etc.) of a transducer when subjected to low temperature environments; and (3) are methods or apparatus available to calibrate cryogenically pressure transducers under static and dynamic conditions. Some information is available on the low-temperature performance of relatively few pressure transducer types; however, the information is either in the form of manufacturing specifications or unpublished reports. The results of this study clearly indicate that individual transducers, even from the same manufacturer, can exhibit totally different characteristics when subjected to identical cryogenic test procedures. This indicates the necessity of calibrating each transducer for use at low temperature. Also included in the discussion is the description of a static/dynamic low-temperature pressure transducer calibration facility, which is currently being developed.

Arvidson, J. M.↗

Human Thermal Assessment of Traverse and Geology Task Iterations During Simulated Lunar Extravehicular Activity

Spacewalks or extravehicular activities (EVA) in microgravity are mentally and physically demanding. Current microgravity EVAs are predominantly focused on upper body tasks on engineered surfaces; however, the introduction of gravity means that crew members during future lunar EVAs will be required to perform tasks that generate full body workloads such as navigating natural lunar terrain while conducting geological sampling. To date, only 12 people have walked on the surface of the Moon resulting in limited knowledge of suited thermal regulation under lunar-relevant physical workloads. To address this gap, a study is underway to focus on spacesuit operations with simulated lunar EVA workloads. This study presents methodology for collecting standard thermal measures during suit testing. In this pilot study, two suited subjects underwent simulated lunar EVAs using the NASA Active Response Gravity Offload System (ARGOS) to simulate the effects of partial gravity. Each lunar EVA, lasting three to five hours, included various metabolically demanding EVA tasks. Subjects donned the NASA Mark III (MK III) space suit and were offloaded to 1/6th G (lunar gravity). A subset task circuit from one of these simulations replicated an EVA traverse to a lunar crater, taking a geological sample, and returning to base. The suited subject walked one 1500 m (0% grade) and three 500 m traverses at three different grades (10, 20, 30%). Between each traverse, subjects performed geology sampling tasks (0 and 10% grade). Thermal measurements included core and skin temperature, liquid cooling garment (LCG) inlet and outlet temperature, and spacesuit gas inlet and outlet temperature and humidity. Compared to baseline core temperature (S1 = 37.07±0.32 °C, S2 = 37.27±0.01 °C) and mean skin temperature (S1 = 32.38±0.34 °C, S2 = 33.62±0.03 °C), after a 1500 m traverse, each suited subject showed an increased core temperature (S1 = 37.23±0.12 °C, S2 = 37.41±0.11°C) and decreased mean skin temperature (S1 = 32.16±0.17 °C, S2 = 31.53±1.15 °C) at a delta LCG temperature (S1 = 1.86±0.24 °C, S2 = 2.20±0.76 °C) and delta suit humidity (S1 = 9.66±1.49 %, S2 = 11.50±1.58 %). Core temperature continued to increase from compounding traverse and geology tasks (S1 = 38.04±0.03 °C, S2 = 38.1±0.02 °C) accompanied by an increase in delta LCG temperature (S1 = 2.24±0.13 °C, S2 = 2.67±0.12 °C) and delta suit humidity (S1 = 28±2.42 %, S2 = 31±2.13 %). Conversely, as the circuit progressed, mean skin temperature continued to decrease due to sustained LCG heat rejection (S1 = 30.08±0.15 °C, S2 = 30.28±0.07 °C). During the simulated EVA circuit core temperature increased to elevated values and remained elevated as heat was retained while mean skin temperature decreased due to peripheral heat offloaded to the LCG. The thermal measures collected during this study provided critical heat loading dynamics during lunar EVA tasks. Including core and skin temperatures along with suited thermal measures provides a standard data collection scheme for human thermal metrics during EVA task management. Data collected in this configuration can be used to build future lunar EVA task circuits and human thermal predictions.

Bradley Hoffmann↗

Structure and dynamics of amorphous water ice

Further insight into the structure and dynamics of amorphous water ice, at low temperatures, was obtained by trapping in it Ar, Ne, H2, and D2. Ballistic water-vapor deposition results in the growth of smooth, approximately 1 x 0.2 micrometer2, ice needles. The amorphous ice seems to exist in at least two separate forms, at T < 85 K and at 85 < T < 136.8 K, and transform irreversibly from one form to the other through a series of temperature-dependent metastable states. The channels formed by the water hexagons in the ice are wide enough to allow the free penetration of H2 and D2 into the ice matrix even in the relatively compact cubic ice, resulting in H2-(D2-) to-ice ratios (by number) as high as 0.63. The larger Ar atoms can penetrate only into the wider channels of amorphous ice, and Ne is an intermediate case. Dynamic percolation behavior explains the emergence of Ar and Ne (but not H2 and D2) for the ice, upon warming, in small and big gas jets. The big jets, each containing approximately 5 x 10(10) atoms, break and propel the ice needles. Dynamic percolation also explains the collapse of the ice matrix under bombardment by Ar , at a pressure exceeding 2.6 dyn cm-2, and the burial of huge amounts of gas inside the collapsed matrix, up to an Ar-to-ice of 3.3 (by number). The experimental results could be relevant to comets, icy satellites, and icy grain mantles in dense interstellar clouds.

NASA Program Exobiology↗

Mixing and the dynamics of the deep chlorophyll maximum in Lake Tahoe

Chlorophyll-temperature profiles were measured across Lake Tahoe about every 10 days from April through July 1980. Analysis of the 123 profiles and associated productivity and nutrient data identified three important processes in the formation and dynamics of the deep chlorophyll maximum (DCM): turbulent diffusion, nutrient supply rate, and light availability. Seasonal variation in these three processes resulted in three regimes: a diffusion-dominated regime with a weak DCM, a variable-mixing regime with a pronounced, nutrient supply-dominated DCM, and a stable regime with a deep, moderate light availability-dominated DCM. The transition between the first two regimes occurred in about 10 days, the transition between the last two more gradually over about 3 weeks. The degree of spatial variability of the DCM was highest in the second regime and lowest in the third. These data indicate that the DCM in Lake Tahoe is constant in neither time nor space.

Abbott, M. R.↗

Solar dynamic space power system heat rejection

A radiator system concept is described that meets the heat rejection requirements of the NASA Space Station solar dynamic power modules. The heat pipe radiator is a high-reliability, high-performance approach that is capable of erection in space and is maintainable on orbit. Results are present of trade studies that compare the radiator system area and weight estimates for candidate advanced high performance heat pipes. The results indicate the advantages of the dual-slot heat pipe radiator for high temperature applications as well as its weight-reduction potential over the range of temperatures to be encountered in the solar dynamic heat rejection systems.

Carlson, A. W.↗

Performance of High-frequency High-flux Magnetic Cores at Cryogenic Temperatures

Three magnetic powder cores and one ferrite core, which are commonly used in inductor and transformer design for switch mode power supplies, were selected for investigation at cryogenic temperatures. The powder cores are Molypermalloy Core (MPC), High Flux Core (HFC), and Kool Mu Core (KMC). The performance of four inductors utilizing these cores has been evaluated as a function of temperature from 20 C to -180 C. All cores were wound with the same wire type and gauge to obtain equal values of inductance at room temperature. Each inductor was evaluated in terms of its inductance, quality (Q) factor, resistance, and dynamic hysteresis characteristics (B-H loop) as a function of temperature and frequency. Both sinusoidal and square wave excitations were used in these investigations. Measured data obtained on the inductance showed that both the MPC and the HFC cores maintain a constant inductance value, whereas with the KMC and ferrite core hold a steady value in inductance with frequency but decrease as temperature is decreased. All cores exhibited dependency, with varying degrees, in their quality factor and resistance on test frequency and temperature. Except for the ferrite, all cores exhibited good stability in the investigated properties with temperature as well as frequency. Details of the experimental procedures and test results are presented and discussed in the paper.

Gerber, Scott S.↗

Trends in stratospheric temperature

Stratospheric temperatures for long-term and recent trends and the determination of whether observed changes in upper stratospheric temperatures are consistent with observed ozone changes are discussed. The long-term temperature trends were determined up to 30mb from radiosonde analysis (since 1970) and rocketsondes (since 1969 and 1973) up to the lower mesosphere, principally in the Northern Hemisphere. The more recent trends (since 1979) incorporate satellite observations. The mechanisms that can produce recent temperature trends in the stratosphere are discussed. The following general effects are discussed: changes in ozone, changes in other radiatively active trace gases, changes in aerosols, changes in solar flux, and dynamical changes. Computations were made to estimate the temperature changes associated with the upper stratospheric ozone changes reported by the Solar Backscatter Ultraviolet (SBUV) instrument aboard Nimbus-7 and the Stratospheric Aerosol and Gas Experiment (SAGE) instruments.

Schoeberl, M. R.↗

On the kinetic temperature of He/++/ in the solar wind.

Observations of solar-wind He(++) can be useful for studying dynamical processes in the interplanetary medium. Several processes which may influence the kinetic temperature are considered, and an attempt is made to inquire whether they can account for the observed fact that the kinetic temperature exceeds the proton temperature. Resonant heating is discussed qualitatively, and equations of resonant heating are developed. The proton and He(++) heating rates are determined for the least damped magnetoacoustic wave under various conditions.

Barnes, A.↗

Microwave Brightness Temperatures of Tilted Convective Systems

Aircraft and ground-based radar data from the Tropical Ocean and Global Atmosphere Coupled-Ocean Atmosphere Response Experiment (TOGA COARE) show that convective systems are not always vertical. Instead, many are tilted from vertical. Satellite passive microwave radiometers observe the atmosphere at a viewing angle. For example, the Special Sensor Microwave/Imager (SSM/I) on Defense Meteorological Satellite Program (DMSP) satellites and the Tropical Rainfall Measurement Mission (TRMM) Microwave Imager (TMI) on the TRMM satellite have an incident angle of about 50deg. Thus, the brightness temperature measured from one direction of tilt may be different than that viewed from the opposite direction due to the different optical depth. This paper presents the investigation of passive microwave brightness temperatures of tilted convective systems. To account for the effect of tilt, a 3-D backward Monte Carlo radiative transfer model has been applied to a simple tilted cloud model and a dynamically evolving cloud model to derive the brightness temperature. The radiative transfer results indicate that brightness temperature varies when the viewing angle changes because of the different optical depth. The tilt increases the displacements between high 19 GHz brightness temperature (Tb(sub 19)) due to liquid emission from lower level of cloud and the low 85 GHz brightness temperature (Tb(sub 85)) due to ice scattering from upper level of cloud. As the resolution degrades, the difference of brightness temperature due to the change of viewing angle decreases dramatically. The dislocation between Tb(sub 19) and Tb(sub 85), however, remains prominent.

Hong, Ye↗

Temperature Dependence of the Thermal Conductivity of Single Wall Carbon Nanotubes

The thermal conductivity of several single wall carbon nanotubes (CNT) has been calculated over a temperature range of 100-500 K using molecular dynamics simulations with Tersoff-Brenner potential for C-C interactions. In all cases, starting from similar values at 100K, thermal conductivities show a peaking behavior before falling off at higher temperatures. The peak position shifts to higher temperatures for nanotubes of larger diameter, and no significant dependence on the tube chirality is observed. It is shown that this phenomenon is due to onset of Umklapp scattering, which shifts to higher temperatures for nanotubes of larger diameter.

Osman, Mohamed A.↗

Species and temperature measurement in H2/O2 rocket flow fields by means of Raman scattering diagnostics

Validation of CFD codes developed for prediction and evaluation of rocket performance is hampered by a lack of experimental data. Nonintrusive laser based diagnostics are needed to provide spatially and temporally resolved gas dynamic and fluid dynamic measurements. This paper reports the first nonintrusive temperature and species measurements in the plume of a 110 N gaseous hydrogen/oxygen thruster at and below ambient pressures, obtained with spontaneous Raman spectroscopy. Measurements at 10 mm downstream of the exit plane are compared with predictions from a numerical solution of the axisymmetric Navier-Stokes and species transport equations with chemical kinetics, which fully model the combustor-nozzle-plume flowfield. The experimentally determined oxygen number density at the centerline at 10 mm downstream of the exit plane is four times that predicted by the model. The experimental number density data fall between those numerically predicted for the exit and 10 mm downstream planes in both magnitude and radial gradient. The predicted temperature levels are within 10 to 15 percent of measured values.

De Groot, Wim A.↗

An advanced arc track resistant airframe wire

Tensolite, a custom cable manufacturer specializing in high temperature materials as the dielectric medium, develops an advance arc track resistant airframe wire called Tufflite 2000. Tufflite 2000 has the following advantages over the other traditional wires: lighter weight and smaller in diameter; excellent wet and dry arc track resistance; superior dynamic cut-through performance even at elevated temperatures; flight proven performance on Boeing 737 and 757 airplanes; and true 260 C performance by utilizing Nickel plated copper conductors. This paper reports the different tests performed on Tufflite 2000: accelerated aging, arc resistance (wet and dry), dynamic cut through, humidity resistance, wire-to-wire abrasion, flammability, smoke, weight, notch sensitivity, flexibility, and markability. It particularly focuses on the BSI (British Standards Institute) dry arc resistance test and BSI wet arc tracking.

Beatty, J.↗

Room-temperature InGaAs detector arrays for 1.0 - 1.7 microns spectroscopy

Linear arrays of 256 element InGaAs detectors with 100 x 30 micron pixels were mounted in multiplexer packages and tested in an optical multichannel analyzer (OMA). Typical performance characteristics include dark current (-5V) of 400 picoamps and responsivities of 0.75 A/W (1.3 microns) and 0.14 A/W (0.85 microns). The 256 element exhibited a mean room-temperature dark current of under 400 picoamps when mounted in the OMA and a dynamic range over 11 bits (2000:1). Future applications, including room-temperature detector arrays for 2.5 microns and avalanche photodiode arrays for 1.0-1.7 microns, are discussed.

Olsen, G. H.↗

Analysis and design of an ultrahigh temperature hydrogen-fueled MHD generator

A coupled gas dynamics/radiative heat transfer analysis of partially ionized hydrogen, in local thermodynamic equilibrium, flowing through an ultrahigh temperature (10,000-20,000 K) magnetohydrodynamic (MHD) generator is performed. Gas dynamics are modeled by a set of quasi-one-dimensional, nonlinear differential equations which account for friction, convective and radiative heat transfer, and the interaction between the ionized gas and applied magnetic field. Radiative heat transfer is modeled using nongray, absorbing-emitting 2D and 3D P-1 approximations which permit an arbitrary variation of the spectral absorption coefficient with frequency. Gas dynamics and radiative heat transfer are coupled through the energy equation and through the temperature- and density-dependent absorption coefficient. The resulting nonlinear elliptic problem is solved by iterative methods. Design of such MHD generators as onboard, open-cycle, electric power supplies for a particular advanced airbreathing propulsion concept produced an efficient and compact 128-MWe generator characterized by an extraction ratio of 35.5 percent, a power density of 10,500 MWe/cu m, and a specific (extracted) energy of 324 MJe/kg of hydrogen. The maximum wall heat flux and total wall heat load were 453 MW/sq m and 62 MW, respectively.

Moder, Jeffrey P.↗

Computer program for analysis of split-Stirling-cycle cryogenic coolers

A computer program for predicting the detailed thermodynamic performance of split-Stirling-cycle refrigerators has been developed. The mathematical model includes the refrigerator cold head, free-displacer/regenerator, gas transfer line, and provision for modeling a mechanical or thermal compressor. To allow for dynamic processes (such as aerodynamic friction and heat transfer) temperature, pressure, and mass flow rate are varied by sub-dividing the refrigerator into an appropriate number of fluid and structural control volumes. Of special importance to modeling of cryogenic coolers is the inclusion of real gas properties, and allowance for variation of thermo-physical properties such as thermal conductivities, specific heats and viscosities, with temperature and/or pressure. The resulting model, therefore, comprehensively simulates the split-cycle cooler both spatially and temporally by reflecting the effects of dynamic processes and real material properties.

Brown, M. T.↗

Electron densities and temperatures in the Venus ionosphere Effects of solar EUV, solar wind pressure and magnetic field

The Venus ionosphere is influenced by variations in both solar EUV flux and solar wind conditions. On the dayside the location of the topside of the ionosphere, the ionopause, is controlled by solar wind dynamic pressure. Within the dayside ionosphere, however, electron density is affected mainly by solar EUV variations, and is relatively unaffected by solar wind variations and associated magnetic fields induced within the ionosphere. The existence of a substantial nightside ionosphere of Venus is thought to be due to the rapid nightward transport of dayside ionospheric plasma across the terminator. Typical solar wind conditions do not strongly affect this transport and consequently have little direct influence on nightside ionospheric conditions, except on occasions of extremely high solar wind dynamic pressure. However, both nightside electron density and temperature are affected by the presence of magnetic field, as in the case of ionospheric holes.

Elphic, R. C.↗

Second coefficient of viscosity in air

Acoustic attenuation measurements in air were analyzed in order to estimate the second coefficient of viscosity. Data over a temperature range of 11 C to 50 C and at relative humidities between 6 percent and 91 percent were used. This analysis showed that the second coefficient of viscosity varied between 1900 and 20,000 times larger than the dynamic or first coefficient of viscosity over the temperature and humidity range of the data. In addition, the data showed that the molecular relaxation effects, which are responsible for the magnitude of the second coefficient of viscosity, place severe limits on the use of time-independent, thermodynamic equations of state. Compressible flows containing large streamwise velocity gradients, like shock waves, which cause significant changes in particle properties to occur during time intervals shorter than hundredths of seconds, must be modeled using dynamic equations of state. The dynamic model approach is described briefly.

Ash, Robert L.↗

Laser Rayleigh and Raman Diagnostics for Small Hydrogen/oxygen Rockets

Localized velocity, temperature, and species concentration measurements in rocket flow fields are needed to evaluate predictive computational fluid dynamics (CFD) codes and identify causes of poor rocket performance. Velocity, temperature, and total number density information have been successfully extracted from spectrally resolved Rayleigh scattering in the plume of small hydrogen/oxygen rockets. Light from a narrow band laser is scattered from the moving molecules with a Doppler shifted frequency. Two components of the velocity can be extracted by observing the scattered light from two directions. Thermal broadening of the scattered light provides a measure of the temperature, while the integrated scattering intensity is proportional to the number density. Spontaneous Raman scattering has been used to measure temperature and species concentration in similar plumes. Light from a dye laser is scattered by molecules in the rocket plume. Raman spectra scattered from major species are resolved by observing the inelastically scattered light with linear array mounted to a spectrometer. Temperature and oxygen concentrations have been extracted by fitting a model function to the measured Raman spectrum. Results of measurements on small rockets mounted inside a high altitude chamber using both diagnostic techniques are reported.

Degroot, Wilhelmus A.↗