Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

New dynamic diamond anvil cells for tera-pascal per second fast compression x-ray diffraction experiments

Fast compression experiments performed using dynamic diamond anvil cells (dDACs) employing piezoactuators offer the opportunity to study compression-rate dependent phenomena. In this paper, we describe an experimental setup which allows us to perform time-resolved x-ray diffraction during the fast compression of materials using improved dDACs. The combination of the high flux available using a 25.6 keV x-ray beam focused with a linear array of compound refractive lenses and the two fast GaAs LAMBDA detectors available at the Extreme Conditions Beamline (P02.2) at PETRA III enables the collection of x-ray diffraction patterns at an effective repetition rate of up to 4 kHz. Compression rates of up to 160 TPa/s have been achieved during the compression of gold in a 2.5 ms fast compression using improved dDAC configurations with more powerful piezoactuators. The application of this setup to low-Z compounds at lower compression rates is described, and the high temporal resolution of the setup is demonstrated. The possibility of applying finely tuned pressure profiles opens opportunities for future research, such as using oscillations of the piezoactuator to mimic propagation of seismic waves in the Earth.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In situ x-ray diffraction study of polyamorphism in H 2 O under isothermal compression and decompression

Amorphous-amorphous transformations in H 2 O have been studied under rapid isothermal compression and decompression in a diamond anvil cell together with in situ x-ray diffraction measurements using brilliant synchrotron radiation. The experimental pathways provide a density-driven approach for studying polyamorphic relations among low-, high-, and very high-density amorphs (LDA, HDA, VHDA) in a pressure range of 0-3.5 GPa at temperatures of 145-160 K. Our approach using rapid (de) compression allows for studying the polyamorphic transformations at higher temperatures than the conditions previously studied under slow (de) compression or isobaric annealing. Multiple compression-decompression cycles can be integrated with in situ x-ray measurements, thus facilitating the study of repeatability and reversibility of the polyamorphic transformations. Fast in situ x-ray diffraction measurements allow for obtaining detailed insight into the structural changes across polyamorphic transformations regarding the (dis) continuity, reversibility, and possible intermediate forms. As demonstrated at isothermal conditions of 145 K and 155 K, the polyamorphic transformations are characterized by a sharp and reversible LDA-VHDA transformation, with an HDA-like form (referred to as HDA' appearing as an intermediate state. The LDA-VHDA transformation is found to occur in two steps: a discontinuous transition between LDA and HDA' and a continuous change within HDA' involving structural reconfigurations and finally converging to VHDA. Published under license by AIP Publishing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Femtosecond gas-phase mega-electron-volt ultrafast electron diffraction

The development of ultrafast gas electron diffraction with nonrelativistic electrons has enabled the determination of molecular structures with atomic spatial resolution. It has, however, been challenging to break the picosecond temporal resolution barrier and achieve the goal that has long been envisioned—making space- and-time resolved molecular movies of chemical reaction in the gas-phase. Recently, an ultrafast electron diffraction (UED) apparatus using mega-electron-volt (MeV) electrons was developed at the SLAC National Accelerator Laboratory for imaging ultrafast structural dynamics of molecules in the gas phase. The SLAC gas-phase MeV UED has achieved 65 fs root mean square temporal resolution, 0.63 Å spatial resolution, and 0.22 Å−1 reciprocal-space resolution. Such high spatial-temporal resolution has enabled the capturing of real-time molecular movies of fundamental photochemical mechanisms, such as chemical bond breaking, ring opening, and a nuclear wave packet crossing a conical intersection. In this paper, the design that enables the high spatial-temporal resolution of the SLAC gas phase MeV UED is presented. The compact design of the differential pump section of the SLAC gas phase MeV UED realized five orders-of-magnitude vacuum isolation between the electron source and gas sample chamber. The spatial resolution, temporal resolution, and long-term stability of the apparatus are systematically characterized.

74 ATOMIC AND MOLECULAR PHYSICS↗

Economical Laue x-ray diffraction using photographic film and orientation of single crystals

Many Laue x-ray diffraction systems using the Polaroid XR-7 Land Diffraction Cassette camera became inactive after production of the required high sensitivity Polaroid T-57 instant film ceased. This Tutorial reports on a low-cost solution using the readily available replacement film with push processing to increase the effective film speed. The use of this film in the polaroid camera is described along with film development and digitization. The orientation of single crystals with the obtained data and free software is explained. A simple method to prepare single crystals with surfaces perpendicular to a desired crystallographic orientation is described. The content of this Tutorial may prove beneficial for educational and research laboratories.

47 OTHER INSTRUMENTATION↗

A kiloelectron-volt ultrafast electron micro-diffraction apparatus using low emittance semiconductor photocathodes

We report the design and performance of a time-resolved electron diffraction apparatus capable of producing intense bunches with simultaneously single digit micrometer probe size, long coherence length, and 200 fs rms time resolution. We measure the 5d (peak) beam brightness at the sample location in micro-diffraction mode to be 7×1013 A/m2 rad2. To generate high brightness electron bunches, the system employs high efficiency, low emittance semiconductor photocathodes driven with a wavelength near the photoemission threshold at a repetition rate up to 250 kHz. We characterize spatial, temporal, and reciprocal space resolution of the apparatus. We perform proof-of-principle measurements of ultrafast heating in single crystal Au samples and compare experimental results with simulations that account for the effects of multiple scattering.

43 PARTICLE ACCELERATORS↗

Relativistic ultrafast electron diffraction at high repetition rates

The ability to resolve the dynamics of matter on its native temporal and spatial scales constitutes a key challenge and convergent theme across chemistry, biology, and materials science. The last couple of decades have witnessed ultrafast electron diffraction (UED) emerge as one of the forefront techniques with the sensitivity to resolve atomic motions. Increasingly sophisticated UED instruments are being developed that are aimed at increasing the beam brightness in order to observe structural signatures, but so far they have been limited to low average current beams. Here, we present the technical design and capabilities of the HiRES (High Repetition-rate Electron Scattering) instrument, which blends relativistic electrons and high repetition rates to achieve orders of magnitude improvement in average beam current compared to the existing state-of-the-art instruments. The setup utilizes a novel electron source to deliver femtosecond duration electron pulses at up to MHz repetition rates for UED experiments. Instrument response function of sub-500 fs is demonstrated with < 100 fs time resolution targeted in future. We provide example cases of diffraction measurements on solid-state and gas-phase samples, including both micro- and nanodiffraction (featuring 100 nm beam size) modes, which showcase the potential of the instrument for novel UED experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operando single crystal neutron diffraction reveals insight into the field response mechanisms in the hydrogen-bonded KH 2 PO 4 ferroelectric

The mechanism that facilitates polarization reorientation in KH 2 PO 4 (KDP) was investigated using operando single-crystal neutron diffraction. Diffraction data were measured from a KDP single crystal during the application of alternating electric fields and were then binned into 40 increments to enable field-dependent single-crystal structure refinements. The field-dependent structures are compared with an as-grown crystal to determine how the lattice and atomic sites evolve in response to the applied electric fields. These analyses provide evidence that the reorientation of the macroscopic polarization is facilitated through a cooperative change in hydrogen bonding, which results in the reversal of the spontaneous dipole. In addition, a decrease in secondary extinction near the coercive field indicates that the inversion of the macroscopic polarization is achieved through the nucleation and subsequent growth of new domains.

36 MATERIALS SCIENCE↗

Non-conventional bell-shaped diffuse scattering in low-energy electron diffraction from high-quality epitaxial 2D-materials

A broad, bell-shaped intensity component is observed in low-energy electron diffraction from high-quality epitaxial 2D-systems. Three 2D-systems, graphene on Ir(111), graphene on SiC(0001), and hexagonal boron nitride on Ir(111), have been prepared in situ under ultra-high vacuum conditions. In all three systems—independent of substrate material—similar strong diffuse intensity is observed, exhibiting a width as large as 50% of the Brillouin zone and an integrated intensity more than 10 times the intensity of the Bragg spots. The presented experimental results provide evidence for a common origin of such diffuse diffraction intensity in different atomically thin 2D-materials.

Omambac, K. (ORCID:0000000250139567)↗

Developing a platform for Fresnel diffractive radiography with 1 μ m spatial resolution at the National Ignition Facility

An x-ray Fresnel diffractive radiography platform was designed for use at the National Ignition Facility. It will enable measurements of micron-scale changes in the density gradients across an interface between isochorically heated warm dense matter materials, the evolution of which is driven primarily through thermal conductivity and mutual diffusion. Here we use 4.75 keV Ti K-shell x-ray emission to heat a 1000 μm diameter plastic cylinder, with a central 30 μm diameter channel filled with liquid D 2 , up to 8 eV. This leads to a cylindrical implosion of the liquid D 2 column, compressing it to ~2.3 g/cm 3 . After pressure equilibration, the location of the D 2 /plastic interface remains steady for several nanoseconds, which enables us to track density gradient changes across the material interface with high precision. For radiography, we use Cu He- α x rays at 8.3 keV. Using a slit aperture of only 1 μm width increases the spatial coherence of the source, giving rise to significant diffraction features in the radiography signal, in addition to the refraction enhancement, which further increases its sensitivity to density scale length changes at the D 2 /plastic interface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coherent diffractive imaging with twisted X-rays: Principles, applications, and outlook

Recent technological breakthroughs in synchrotron and x-ray free electron laser facilities have revolutionized nanoscale structural and dynamic analyses in condensed matter systems. This review provides a comprehensive overview of the advancements in coherent scattering and diffractive imaging techniques, which are now at the forefront of exploring materials science complexities. These techniques, notably Bragg coherent diffractive imaging and x-ray photon correlation spectroscopy, x-ray magnetic dichroism, and x-ray correlation analysis leverage beam coherence to achieve volumetric three-dimensional imaging at unprecedented sub-nanometer resolutions and explore dynamic phenomena within sub-millisecond timeframes. Such capabilities are critical in understanding and developing advanced materials and technologies. Simultaneously, the emergence of chiral crystals—characterized by their unique absence of standard inversion, mirror, or other roto-inversion symmetries—presents both challenges and opportunities. These materials exhibit distinctive interactions with light, leading to phenomena such as molecular optical activity, chiral photonic waveguides, and valley-specific light emissions, which are pivotal in the burgeoning fields of photonic and spintronic devices. This review elucidates how novel x-ray probes can be leveraged to unravel these properties and their implications for future technological applications. A significant focus of this review is the exploration of new avenues in research, particularly the shift from conventional methods to more innovative approaches in studying these chiral materials. Inspired by structured optical beams, the potential of coherent scattering techniques utilizing twisted x-ray beams is examined. This promising direction not only offers higher spatial resolution but also opens the door to previously unattainable insights in materials science. By contextualizing these advancements within the broader scientific landscape and highlighting their practical applications, this review aims to chart a course for future research in this rapidly evolving field.

Physics↗

On single-crystal neutron-diffraction in DACs: quantitative structure refinement of light elements on SNAP and TOPAZ

Quantitative single crystal neutron-diffraction in diamond anvil cells has so far been limited by the neutron flux available at the various neutron sources. As a result, highly precise measurements of the exact position of light elements have not been possible preventing, for example, structural studies of hydrogen and hydrogen bonds under pressure. Here we report experiments carried out on SNAP at the Spallation Neutron Source (ORNL, TN, USA) to explore the possibility and current limits of such studies. Furthermore, we benchmarked the obtained data quality with reference experiments carried out on TOPAZ, a dedicated single-crystal instrument.We show that measuring single-crystal diffraction intensities on SNAP is possible to such a precision that we are able to resolve the hydrogen bonds in potassium dideuterium phosphate (DKDP) as well as in ice VI.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Structural properties of PbTe quantum dots revealed by high-energy x-ray diffraction

High-energy x-ray diffraction (HE-XRD) experiments combined with an analysis based on atomic-pair-distribution functions can be an effective tool for probing low-dimensional materials. Here, we show how such an analysis can be used to gain insight into structural properties of PbTe nanoparticles (NPs). Here we interpret our HE-XRD data using an orthorhombic Pnma phase of PbTe, which is an orthorhombic distortion of the rocksalt phase. Although local crystal geometry can vary substantially with particle size at scales below 10 nm, and for very small NPs the particle size itself influences x-ray diffraction patterns, our study shows that HE-XRD can provide a unique nano-characterization tool for unraveling structural properties of nanoscale systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photoproduction of J /ψ in non-single-diffractive p+p collisions

Significant enhancements of $ J/\psi $ production at very low transverse momenta were recently observed by the ALICE and STAR collaborations in peripheral hadronic A+A collisions. The anomalous excess points to coherent photon-nucleus interactions in violent hadronic heavy-ion collisions, which were conventionally studied only in ultra-peripheral collisions. Assuming that the coherent photoproduction is the underlying mechanism responsible for the excess observed in peripheral A+A collisions, its contribution in p+p collisions with nuclear overlap, i.e. non-single-diffractive collisions, is of particular interest. In this paper, we perform a calculation of exclusive $ J/\psi $ photoproduction in non-single-diffractive p+p collisions at the RHIC and LHC energies based on the pQCD motivated parametrization using the world-wide experimental data, which could be further employed to improve the precision of the phenomenological calculations for photoproduction in A+A collisions. The differential rapidity and transverse momentum distributions of $ J/\psi $ from photoproduction are presented. In comparison with the $ J/\psi $ production from hadronic interactions, we find that the contribution of photoproduction is negligible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Asymmetric nanoparticle oxidation observed in-situ by the evolution of diffraction contrast

Abstract The use of transmission electron microscopy (TEM) to observe real-time structural and compositional changes has proven to be a valuable tool for understanding the dynamic behavior of nanomaterials. However, identifying the nanoparticles of interest typically require an obvious change in position, size, or structure, as compositional changes may not be noticeable during the experiment. Oxidation or reduction can often result in subtle volume changes only, so elucidating mechanisms in real-time requires atomic-scale resolution or in-situ electron energy loss spectroscopy, which may not be widely accessible. Here, by monitoring the evolution of diffraction contrast, we can observe both structural and compositional changes in iron oxide nanoparticles, specifically the oxidation from a wüstite-magnetite (FeO@Fe 3 O 4 ) core – shell nanoparticle to single crystalline magnetite, Fe 3 O 4 nanoparticle. The in-situ TEM images reveal a distinctive light and dark contrast known as the ‘Ashby-Brown contrast’, which is a result of coherent strain across the core – shell interface. As the nanoparticles fully oxidize to Fe 3 O 4 , the diffraction contrast evolves and then disappears completely, which is then confirmed by modeling and simulation of TEM images. This represents a new, simplified approach to tracking the oxidation or reduction mechanisms of nanoparticles using in-situ TEM experiments.

36 MATERIALS SCIENCE↗

Crystal structure and thermal expansion of Ta 2 ⁢O 5 from neutron diffraction

Tantalum pentoxide (Ta 2 ⁢O 5 ) is a component of technologies ranging from photographic lenses to medical implants. Despite more than six decades of interest, however, there is no consensus on the crystal structure of Ta 2 ⁢O 5 . Here, we report the results of neutron diffraction experiments on Ta 2⁢ O 5 powders at temperatures up to 1000⁢°⁢C. Because neutron diffraction is sensitive to the positions of O atoms in the presence of heavy elements, our results provide strong evidence that the orthorhombic L SR structure can account for experimental observations better than any other proposal in the literature. Here, we also determine the anisotropic crystallographic thermal expansion parameters of Ta 2 ⁢O 5 , which are important for modeling the performance of Ta 2⁢ O 5 -bearing technologies.

36 MATERIALS SCIENCE↗

Concurrent probing of electron-lattice dephasing induced by photoexcitation in 1 T -TaSeTe using ultrafast electron diffraction

It has been technically challenging to concurrently probe the electrons and the lattices in materials during nonequilibrium processes, allowing their correlations to be determined. Here, in a single set of ultrafast electron diffraction patterns taken on the charge-density-wave (CDW) material 1T-TaSeTe, we discover a temporal shift in the diffraction intensity measurements as a function of scattering angle. With the help of dynamic models and theoretical calculations, we show that the ultrafast electrons probe both the valence-electron and lattice dynamic processes, resulting in the temporal shift measurements. Our results demonstrate unambiguously that the CDW is not merely a result of the periodic lattice deformation ever present in 1T-TaSeTe but has significant electronic origin. This method demonstrates an approach for studying many quantum effects that arise from electron-lattice dephasing in molecules and crystals for next-generation devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Long-range three-dimensional magnetic structures of the spin S =1 hexamer cluster fedotovite-like A 2 Cu 3 O ( SO 4 ) 3 ( A 2 = K 2 , NaK, Na 2 ): A neutron diffraction study

The crystal and magnetic structures of the spin S = 1 hexamer cluster fedotovite-like A 2 Cu 3 O(SO 4 ) 3 (A 2 = K 2 , NaK, Na 2 ) were studied by neutron powder diffraction at temperatures 1.6–290 K. The crystal structures in all compounds are well refined in the monoclinic space group C2/c. The basic magnetic units of the compounds are copper hexamers, which are coupled by weak superexchange interactions giving rise to three-dimensional long-range magnetic order below 3.0 < T N < 4.7 K. We have found that for A 2 = K 2 and NaK the propagation vector of the magnetic structure is k = [0,0,0], and the coupling of the Cu hexamers is ferromagnetic (FM) along the ab diagonal and antiferromagnetic along the bc diagonal. In contrast, for A = Na the propagation vector is k = [0,1,0], and the Cu hexamers are coupled antiferromagnetically (AFM) along the ab diagonal. Further, the hexamers are formed by three Cu pairs arranged along the b axis. The calculated spin expectation values $\langle s \rangle$ for the simplest symmetric spin Hamiltonian (obtained from inelastic neutron spectroscopy) of the isolated hexamers in the mean field amounted to $\langle s \rangle$ = 3/8 for the side spins Cu1 and Cu2 and $\langle s \rangle$ = 1/4 for Cu3 in the middle. The Cu spins are FM coupled in pairs and AFM between neighboring pairs. The experimental magnetic moments of the Cu 2+ ions turn out to be not completely collinear due to spin frustrations within the weak interhexamer interactions. The sizes of magnetic moments of Cu in the hexamers determined from the diffraction data are in fair agreement with the calculated values.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Identification of Phase Transitions and Metastability in Dynamically Compressed Antimony Using Ultrafast X-Ray Diffraction

Ultrafast x-ray diffraction at the LCLS x-ray free electron laser has been used to resolve the structural behavior of antimony under shock compression to 59 GPa. Antimony is seen to transform to the incommensurate, host-guest phase Sb-II at ~11 GPa, which forms on nanosecond timescales with ordered guest-atom chains. The high-pressure bcc phase Sb-III is observed above ~15 GPa, some 8 GPa lower than in static compression studies, and mixed Sb-III/liquid diffraction are obtained between 38 and 59 GPa. An additional phase which does not exist under static compression, Sb–I', is also observed between 8 and 12 GPa, beyond the normal stability field of Sb-I, and resembles Sb-I with a resolved Peierls distortion. In conclusion, the incommensurate Sb-II high-pressure phase can be recovered metastably on release to ambient pressure, where it is stable for more than 10 ns.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗