Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Optical Time-Resolved Diagnostics of Laser-Produced Plasmas

Here we present the general challenges of diagnostics for laser-produced plasmas related to their small dimensions and short duration but also to the presence of very strong temperature and density gradient in the plasma. In particular, we focus on more detailed examples related to optical diagnostics for the undercritical region of the plasma: shadowgraphy, schlieren, interferometry, polarimetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A systematic feature extraction and selection framework for data-driven whole-building automated fault detection and diagnostics in commercial buildings

In data-driven automated fault detection and diagnostics (AFDD) modeling for building energy systems, feature engineering is a critical process of extracting information from high-dimensional and noisy sensor measurement and turning it into informative and representative inputs or features for data-driven modeling. However, few studies specifically discuss the feature engineering, especially the interactions between feature extraction and feature selection in whole-building AFDD. We developed a systematic feature extraction and selection framework for whole-building AFDD. In this framework, features are aggressively extracted from raw sensor data using statistical feature extraction techniques with various window sizes and statistics. With many features extracted, a hybrid feature selection algorithm that combines the filter and wrapper method then selects the best feature set. The framework considers diversity in the duration of fault behavior among fault types in whole-building AFDD, thus achieving high model generalization. We implemented our developed framework in a virtual testbed calibrated with measured data from Oak Ridge National Laboratory's Flexible Research Platform designed to mimic the operation of a typical small commercial building. The AFDD model is trained by the simulation data generated from the virtual testbed. The results show that (1) the developed framework improves the generalization of the AFDD model by 10.7% compared with literature-reported feature extraction and selection methods and (2) features with diverse window sizes and statistics are selected, providing insight into physical systems beyond the current understanding of buildings and faults and improving the detection and diagnostics of multiple fault types.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laser diagnostics to characterize the in-flame growth of platinum nanoparticles manufactured by the reactive spray deposition technology

Reactive Spray Deposition Technology (RSDT) is an atmospheric pressure, flame-based advanced manufacturing method used to fabricate Membrane Electrode Assemblies (MEAs) for proton exchange fuel cells and water electrolyzers. RSDT combines the flame synthesis of catalyst nanoparticles and their deposition onto the membrane in one step. The properties of the synthesized nanoparticles, such as their Size Distribution Function (SDF), determine the manufactured electrodes’ performance, which can be evaluated when the deposition is complete via ex-situ characterization of the products. Efforts to improve RSDT for manufacturing state-of-the-art MEAs can be significantly enhanced with integrated laser diagnostics that enable in situ measurement of the synthesized catalyst nanoparticles. This paper reports the implementation of laser diagnostics in an RSDT facility and evaluates their potential to assist the manufacturing process. Laser Light Scattering (LS) and Laser-Induced Incandescence (LII) measurements are performed in the oxygen-rich zone of the flame at various distances from the flame fuel jet nozzle downstream of its luminous region. The measurements quantitatively track the evolution in size and volume fraction of platinum-based nanoparticles in two flames that yield different catalytic properties in the manufactured electrodes. The profiles of the measured nanoparticles’ volume fraction along the flame axis can be estimated a priori so that the average nanoparticle sizes can be measured in quasi-real time via LS. Nanoparticles experience an extremely slow growth rate while being convected at distances from 150 nm to 300 nm from the fuel nozzle. Complementary characterizations of the synthesized nanoparticles are performed ex-situ via High-Angle Annular Darkfield Scanning Transmission Electron Microscopy (HAADF-STEM) image analyses of samples collected on grids at a fixed distance from the fuel jet nozzle. Comparing the results from laser and microscopy techniques not only cross-validates the findings but also provides the parameters to infer the bimodal SDF in-situ and yields evidence that the coagulation efficiency of the synthesized nanoparticles has extremely low values in the investigated zone of the flames.

Rayleigh Light Scattering (LS)↗

Jacobian-based model diagnostics and application to equation oriented modeling of a carbon capture system

It can be difficult to identify the specific variables or equations responsible for convergence issues in large mathematical programming models. The Institute for the Design of Advanced Energy Systems Integrated Platform (IDAES-IP) contains a tool to identify poorly scaled constraints and variables by searching for rows and columns of the Jacobian matrix with small L2-norms. A singular value decomposition is then performed to identify degenerate sets of equations and remaining scaling issues. Here, this work presents a flowsheet developed for post-combustion carbon capture using a monoethanolamine (MEA) solvent system as a case study. This work takes the reader through the entire process of model diagnostics and reformulation, from a basic introduction to the mathematics behind these model diagnostics to the reformulations necessary to make the model numerically robust, including a significantly modified enhancement factor model.

IDAES↗

Human Papillomavirus (HPV) Infection in Squamous Cell Carcinomas Arising From the Oropharynx: Detection of HPV DNA and p16 Immunohistochemistry as Diagnostic and Prognostic Indicators—A Pilot Study

Purpose: Human papillomavirus (HPV) 16 infection is associated with oropharyngeal carcinogenesis and is likely the cause of the reported increase in disease incidence. We evaluated the prevalence of HPV infection and the reliability of different diagnostic tools using primary tumor samples from a cohort of 50 patients. Methods and Materials: Formalin-fixed paraffin-embedded (FFPE) tumor samples were collected from all 50 consecutive primary oropharyngeal SCC patients who were enrolled in the study; fresh tumor samples were available in 22 cases. NucliSENS EasyQ HPVv1 was used for RNA, and Digene Hybrid Capture-2(HC2) was used for DNA detection. p16 Expression was evaluated by immunohistochemistry in FPPE specimens. Results: Based on the DNA detection assay on FFPE samples, the frequency of high-risk HPV infection was 32%. The agreement rate between HPV RNA and HPV DNA detection in fresh samples was 100%. The agreement rate between p16 immunohistochemistry (IHC) and the detection of HPV DNA in the FFPE samples was fair but not excellent (κ = 0.618). HPV DNA detection was highly significant, as measured by disease-specific survival and determined using a Wilcoxon test (P=.001). p16 IHC also exhibited a prognostic value but with a lower statistical significance (P=.0475). The detection of HPV DNA, but not p16 IHC, was also significantly correlated with locoregional control (P=.0461). Conclusion: Diagnostic methods based on the detection of HPV nucleic acids appear to be more reliable and objective because they do not require reading by a trained histopathologist. Furthermore, the detection of HPV DNA exhibits an improved correlation with survival, and therefore appears definitely more reliable than p16 IHC for routine use in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the climate policy implications of substitutability and flexibility in the economy: An in-depth integrated assessment model diagnostic

This paper conducts an in-depth model diagnostic exercise for two parameters, 1) the elasticity of substitution between the capital/labour aggregate and the energy aggregate in the Integrated Assessment Model (IAM) MERGE's production function and 2) the rate at which new technologies can be deployed within the energy system. We show that in a more complementary world the model's ability to adjust the carbon intensity of its energy sector is more important whereas in a more substitutable world the ability to expand carbon free technologies is of lesser relative importance. The uncertainty in the literature surrounding the elasticity of substitution parameter, its interaction with the mechanisms of technical change, and the associated danger of grounding forward-looking analyses in historically based parameters lend support to the importance of such a diagnostic exercise. Building on work from model intercomparison studies, we investigate whether a given model's choice of strategy is primarily a function of the choice of its parameter values or its structure. As a result, a deeper understanding of what drives model behaviour is beneficial to both modellers and the policymakers who utilise their insights and output.

54 ENVIRONMENTAL SCIENCES↗

An important criterion for reliable multi-monochromatic x-ray imager diagnostics and its impact on the reconstructed images

Temperature and density asymmetry diagnosis is critical to advance inertial confinement fusion (ICF) science. A multimonochromatic x-ray imager, MMI, records the spectral signature from an ICF implosion core with time resolution, 2D spatial resolution and spectral resolution. While narrow-band images and 2D space-resolved spectra from the MMI data constrain the temperature and the density spatial structure of the core, the accuracy of the images and the spectra highly depends on the quality of the MMI data and the processing tools. Here, we synthetically investigate the criterion for reliable MMI diagnostics and its effects on the accuracy of the reconstructed images. The pinhole array tilt determines the object spatial sampling efficiency and the minimum reconstruction width, $\textit{w}$. When the spectral width associated with $\textit{w}$ is significantly narrower than the spectral linewidth, the line images reconstructed from the MMI data become reliable. The MMI setup has to be optimized for every application to meet this criterion for reliable ICF diagnostics.

47 OTHER INSTRUMENTATION↗

High-power non-perturbative laser delivery diagnostics at the final focus of 100-TW-class laser pulses

Controlling the delivery of multi-terawatt and petawatt laser pulses to final focus, both in position and angle, is critical to many laser applications such as optical guiding, laser–plasma acceleration, and laser-produced secondary radiation. We present an online, non-destructive laser diagnostic, capable of measuring the transverse position and pointing angle at focus. The diagnostic is based on a unique double-surface-coated wedged-mirror design for the final steering optic in the laser line, producing a witness beam highly correlated with the main beam. By propagating low-power kilohertz pulses to focus, we observed spectra of focus position and pointing angle fluctuations dominated by frequencies below 70 Hz. The setup was also used to characterize the excellent position and pointing angle correlation of the 1 Hz high-power laser pulses to this low-power kilohertz pulse train, opening a promising path to fast non-perturbative feedback concepts even on few-hertz-class high-power laser systems.

47 OTHER INSTRUMENTATION↗

Methods to Evaluate Subcolumn Profiles Based on Two-Point Diagnostics

In atmospheric models, stochastic generation of subgrid-scale profiles or “subcolumns” has been used for a variety of purposes. Such subcolumns can be generated from subgrid probability density functions (PDFs) at different vertical levels, when such PDFs are available. To do so, the generator needs to decide how strongly points should be correlated in the vertical, that is, how much the values should be overlapped. This is sometimes called “PDF overlap.” To assess vertical correlation in a simplified, observable setting, here the vertical correlation of vertical velocity in subcloud layers is examined. Doppler lidar is used to evaluate the vertical profiles of vertical velocity produced by a large-eddy simulation (LES) model and the Subgrid Importance Latin Hypercube Sampler (SILHS) subcolumn generator. In order to diagnose unrealistic features in subcolumn profiles, various statistical diagnostics are examined here, including the bivariate PDF of vertical velocity at two separated points (i.e., altitudes), the two-point velocity correlation, the integral correlation length, the PDF of two-point velocity differences, and the skewness and kurtosis of two-point velocity differences. The profiles produced by LES match lidar well, except that they are too smooth at small scales. The profiles produced by SILHS exhibit sharp jumps from updraft to downdraft that are not observed in the lidar data. To reduce the generation of these unrealistically sharp jumps, the SILHS sampling method is revised. The diagnostics confirm that the revised sampling method reduces the overprediction of sharp jumps.

54 ENVIRONMENTAL SCIENCES↗

FDA-ARGOS is a database with public quality-controlled reference genomes for diagnostic use and regulatory science

FDA proactively invests in tools to support innovation of emerging technologies, such as infectious disease next generation sequencing (ID-NGS). Here, we introduce FDA-ARGOS quality-controlled reference genomes as a public database for diagnostic purposes and demonstrate its utility on the example of two use cases. We provide quality control metrics for the FDA-ARGOS genomic database resource and outline the need for genome quality gap filling in the public domain. In the first use case, we show more accurate microbial identification of Enterococcus avium from metagenomic samples with FDA-ARGOS reference genomes compared to non-curated GenBank genomes. In the second use case, we demonstrate the utility of FDA-ARGOS reference genomes for Ebola virus target sequence comparison as part of a composite validation strategy for ID-NGS diagnostic tests. The use of FDA-ARGOS as an in silico target sequence comparator tool combined with representative clinical testing could reduce the burden for completing ID-NGS clinical trials

59 BASIC BIOLOGICAL SCIENCES↗

Probabilistic machine learning for battery health diagnostics and prognostics—review and perspectives

Abstract Diagnosing lithium-ion battery health and predicting future degradation is essential for driving design improvements in the laboratory and ensuring safe and reliable operation over a product’s expected lifetime. However, accurate battery health diagnostics and prognostics is challenging due to the unavoidable influence of cell-to-cell manufacturing variability and time-varying operating circumstances experienced in the field. Machine learning approaches informed by simulation, experiment, and field data show enormous promise to predict the evolution of battery health with use; however, until recently, the research community has focused on deterministic modeling methods, largely ignoring the cell-to-cell performance and aging variability inherent to all batteries. To truly make informed decisions regarding battery design in the lab or control strategies for the field, it is critical to characterize the uncertainty in a model’s predictions. After providing an overview of lithium-ion battery degradation, this paper reviews the current state-of-the-art probabilistic machine learning models for health diagnostics and prognostics. Details of the various methods, their advantages, and limitations are discussed in detail with a primary focus on probabilistic machine learning and uncertainty quantification. Last, future trends and opportunities for research and development are discussed.

25 ENERGY STORAGE↗

Dust trajectories and diagnostic applications beyond strongly coupled dusty plasmas

Plasma interaction with dust is of growing interest for a number of reasons. On the one hand, dusty plasma research has become one of the most vibrant branches of plasma science. On the other hand, substantially less is known about dust dynamics outside the laboratory strongly coupled dusty-plasma regime, which typically corresponds to 10{sup 15} m{sup -3} electron density with ions at room temperature. Dust dynamics is also important to magnetic fusion because of concerns about safety and potential dust contamination of the fusion core. Dust trajectories are measured under two plasma conditions, both of which have larger densities and hotter ions than in typical dusty plasmas. Plasma-flow drag force, dominating over other forces in flowing plasmas, can explain the dust motion. In addition, quantitative understanding of dust trajectories is the basis for diagnostic applications using dust. Observation of hypervelocity dust in laboratory enables dust as diagnostic tool (hypervelocity dust injection) in magnetic fusion. In colder plasmas ({approx}10 eV or less), dust with known physical and chemical properties can be used as microparticle tracers to measure both the magnitude and directions of flows in plasmas with good spatial resolution as the microparticle tracer velocimetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Some plasma aspects and plasma diagnostics of ion sources (invited)

We consider plasma properties in the most advanced type of plasma ion sources, electron cyclotron resonance ion sources for highly charged ions. Depending on the operation conditions the plasma in these sources may be highly ionized, which completely changes its transport properties. The most striking difference to weakly ionized plasma is that diffusion will become intrinsically ambipolar. We further discuss means of plasma diagnostics. As noninvasive diagnostic methods we will discuss analysis of the ion beam, optical spectroscopy, and measurement of the x-ray bremsstrahlung continuum. From beam analysis and optical spectroscopy one may deduce ion densities, and electron densities and distribution functions as a mean over the line of sight along the axis (optical spectroscopy) or at the plasma edge (ion beam). From x-ray spectra one obtains information about the population of highly energetic electrons and the energy transfer from the driving electromagnetic waves to the plasma--basic data for plasma modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Invited Review Article: Contemporary instrumentation and application of charge exchange neutral particle diagnostics in magnetic fusion energy experiments

An overview of the developments postcirca 1980s in the instrumentation and application of charge exchange neutral particle diagnostics on magnetic fusion energy experiments is presented. First, spectrometers that employ only electric fields and hence provide ion energy resolution but not mass resolution are discussed. Next, spectrometers that use various geometrical combinations of both electric and magnetic fields to provide both energy and mass resolutions are reviewed. Finally, neutral particle diagnostics based on utilization of time-of-flight techniques are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scintillator based energetic ion loss diagnostic for the National Spherical Torus Experiment

A scintillator based energetic ion loss detector has been built and installed on the National Spherical Torus Experiment (NSTX) [Synakowski et al., Nucl. Fusion 43, 1653 (2000)] to measure the loss of neutral beam ions. The detector is able to resolve the pitch angle and gyroradius of the lost energetic ions. It has a wide acceptance range in pitch angle and energy, and is able to resolve the full, one-half, and one-third energy components of the 80 keV D neutral beams up to the maximum toroidal magnetic field of NSTX. Multiple Faraday cups have been embedded behind the scintillator to allow easy absolute calibration of the diagnostic and to measure the energetic ion loss in several ranges of pitch angle with good time resolution. Several small, vacuum compatible lamps allow simple calibration of the scintillator position within the field of view of the diagnostic's video camera.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of Inboard-Outboard Pedestal Temperature Measurements in JET Using ECE Diagnostics

Despite considerable effort, both theoretically and experimentally, a complete physical model to describe the particle and energy losses during ELMs is far from complete. On the experimental front, improved description of the spatial structure (poloidal asymmetry, radial distribution) and the dynamics of the ELM crash is a key requirement to answer some of the basic outstanding questions concerning the physics of ELMs. A significant number of diagnostics is now capable of fast measurements of the pedestal profile during an ELM, however, there is a lack of data from the inboard midplane, so assumptions of poloidal symmetry on the flux surfaces have often to be made. The aim of this work is to explore the capabilities of the electron cyclotron emission (ECE) diagnostics to provide simultaneous measurements of the edge temperature for both inboard and outboard plasma midplane. Access to the inboard region of the plasma is achieved in JET by using 1 harmonic/O-mode polarization, as it is not affected by harmonic overlap with the 2{sup nd} harmonic. This paper focuses on the validation of the inboard ECE data and the identification of the limitations of the measurements and the data analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The CXRS diagnostic for ITER and the CXRS-Pilot Experiment on TEXTOR

Charge eXchange Recombination Spectroscopy (CXRS) will play a crucial role in the diagnosing of burning plasmas: items like helium ash, transport barriers, impurity content or fuel ratio can all be assessed with CXRS. In fact this is the only direct method to obtain information about the light impurity ions, such as temperature, concentrations and rotation, in the core of the plasma. Two of such systems are foreseen at ITER, one in the upper port plug and one on the equatorial level, both viewing the 100 keV diagnostic H-beam.Challenges for this diagnostic development project are: constructing a mirror close to the plasma able to keep its reflectivity under the extreme bombardment by neutrons, erosion by fast neutrals and deposition of sputtered material, design of an optical labyrinth with well enough neutron shielding, developing spectrometers with a throughput about a factor 100 larger than on present day devices, with a similar or better dispersion, calibration and alignment techniques and last but not least, finding ways to obtain the physics relevant information from the measured complicated spectra in real time.With all these issues in mind, an ITER-CXRS pilot experiment has been developed and became operational on the TEXTOR tokamak, to address some of the above aspects. The results of this show the feasibility and the sensitivity of the ITER system: the simulation code for ITER signal levels could be verified, the sensitivity to the current profile has been tested, the beam emission has been compared to beam attenuation calculations and used to obtain absolute impurity concentrations and a high throughput spectrometer became operational.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗