At least 649 records · Page 36

PET imaging in patients with coal workers pneumoconiosis and suspected malignancy

Abstract: Positron Emission Tomography (PET) with F-18-fluorodeoxyglucose is commonly used in the evaluation of lung nodules; however, there is limited data on the PET appearance of coal worker's pneumoconiosis (CWP) and its utility for diagnosing lung malignancy in this setting. Six cases of CWP and suspected malignancy are reported. Each patient had at least one nodule >1 cm in diameter for a total of 19 nodules >1 cm. On PET imaging 18 of the 19 nodules were hypermetabolic and five of the six patients had at least one nodule that was PET positive. Based on pathologic data and clinical follow-up, none of the six patients had any evidence of malignancy. In this series, PET imaging was often positive in patients with CWP; however, all were false positives with standardized uptake value measurements in the range that are typically seen with malignant nodules. Due to its high rate of false positives, PET imaging seems to be of limited utility in diagnosing malignancy in patients with underlying coal worker's pneumoconiosis.

01 COAL, LIGNITE, AND PEAT↗

High-Current, Relativistic Electron-Beam Transport in Metals and the Role of Magnetic Collimation

High-resolution coherent transition radiation (CTR) imaging diagnoses electrons accelerated in laser—solid interactions with intensities of ~10^19 W/cm^2. The CTR images indicate electron-beam filamentation and annular propagation. The beam temperature and half-angle divergence are inferred to be ~1:4 MeV and ~16 degrees, respectively. Three-dimensional hybrid-particle-in-cell code simulations reproduce the details of the CTR images assuming an initial half-angle divergence of ~56 degrees. Self-generated resistive magnetic fields are responsible for the difference between the initial and measured divergence.

Storm, M↗

Evidence for Fast-Ion Transport by Microturbulence

Cross-field diffusion of energetic ions by microturbulence is measured during neutral-beam injection into the DIII-D tokamak. Fast-ion D{sub {alpha}}, neutron, and motional Stark effect measurements diagnose the fast-ion distribution function. As expected for transport by plasma turbulence, anomalies relative to the classical prediction are greatest in high temperature plasmas, at low fast-ion energy, and at larger minor radius. Theoretical estimates of fast-ion diffusion are comparable to experimental levels.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MolProbity: all-atom structure validation for macromolecular crystallography

MolProbity structure validation will diagnose most local errors in macromolecular crystal structures and help to guide their correction. MolProbity is a structure-validation web service that provides broad-spectrum solidly based evaluation of model quality at both the global and local levels for both proteins and nucleic acids. It relies heavily on the power and sensitivity provided by optimized hydrogen placement and all-atom contact analysis, complemented by updated versions of covalent-geometry and torsion-angle criteria. Some of the local corrections can be performed automatically in MolProbity and all of the diagnostics are presented in chart and graphical forms that help guide manual rebuilding. X-ray crystallography provides a wealth of biologically important molecular data in the form of atomic three-dimensional structures of proteins, nucleic acids and increasingly large complexes in multiple forms and states. Advances in automation, in everything from crystallization to data collection to phasing to model building to refinement, have made solving a structure using crystallography easier than ever. However, despite these improvements, local errors that can affect biological interpretation are widespread at low resolution and even high-resolution structures nearly all contain at least a few local errors such as Ramachandran outliers, flipped branched protein side chains and incorrect sugar puckers. It is critical both for the crystallographer and for the end user that there are easy and reliable methods to diagnose and correct these sorts of errors in structures. MolProbity is the authors’ contribution to helping solve this problem and this article reviews its general capabilities, reports on recent enhancements and usage, and presents evidence that the resulting improvements are now beneficially affecting the global database.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Rotor Magnet Fault Analysis in Permanent Magnet AC Machines Under Load Conditions - All Electric Transportation Systems

This paper studies the performance of a Permanent Magnet (PM) alternating-current (AC) machine when subjected to faults under load conditions. The effect of varying load torques, and unbalances are found to be potential causes of rotor faults, inducing physical magnet defects or broken rotor-PMs. The consequent and immediate impact on the machine quantities is observed through anomalous change in torque-speed characteristics and other vital signatures such as machine back-EMF/flux and motor current signatures (MCS). The present research study develops and illustrates a method to diagnose physical magnet defects (fault) in PMAC machines by estimating the machine torque/back-EMF constant, Ke. The constant Ke is a measure of magnet strength exhibiting the health of rotor PMs, indicative of faults. Advanced research studies and investigations are carried out to establish motor approximations and signature-based analysis as significant viable tools for diagnosing machine faults even under load conditions.

alternating current↗

Novel Millimeter Wave Sensor Concepts for Energy, Environment, and National Security

Millimeter waves (30 – 300 GHz) are ideally suited for sensing and diagnosing materials, devices, and processes that are broadly important to energy, environment, and national security missions. The wavelengths are long enough to penetrate dust, smoke, and industrial environment yet short enough to enable focusing and manipulating of the signals for useful applications. We have developed a novel thermal return reflection (TRR) technique that uses emission as a probe to interrogate and diagnose materials and systems and determine emissivity and temperature simultaneously. Scientific basis of TRR, 2-D and potentially 3-D measurements, and selected results on application of TRR will be presented. We will also present new sensor concepts based on emit-probe and pump-probe modes to further broaden its applications. In its 3-D manifestation of this technique, one can track three different parameters or view/measure at three different directions (x, y, and z). On application to materials and processes, it shows promise for measuring temperature (T) - position (x) - time (t) simultaneously in real time leading to T-x-t diagrams that can be exploited for spatial resolution of emissivity or stability over a function of time. Selected examples of applications in fusion plasma diagnostics, nuclear waste disposal, and non-proliferation will be presented.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Upgrades of Diagnostic Techniques and Technologies for JET next D-T Campaigns

JET next D-T campaign is presently scheduled for the year 2017. The main scientific objectives include the assessment of the isotopic effects on various plasma aspects: mainly on confinement, on the threshold to access the H mode and on ELM behaviour. From a technical point of view, the total yield of the entire D-T phase is expected to be 1.7 1021 neutrons, about a factor of six higher than the previous main D-T campaign on JET, DTE1. Therefore the radiation field will be quite relevant for next step devices, since the neutron flux at the first wall (∼10{sup 16} n/cm{sup 2}s), for example, will be comparable to the one in ITER behind the blanket. From a point of view of diagnostics developments, for many years JET diagnostics have been upgraded in order to provide adequate support for the scientific exploitation of a D-T campaign. The main efforts have concentrated on improving three main aspects of JET measuring capability: 1) the quality of the measurements of the electron and ion fluids to support the plasma physics programme 2) the diagnostic for the fusion products 3) diagnostic technologies for ITER. In terms of general diagnostic capability, compared to the previous DTE1, JET diagnostics have a much better spatial and temporal resolution of both the ion and electron fluid (about one order of magnitude improvement for each parameter). The consistency of the various independent measurements of the same parameters has also increased significantly; the three independent measurements of the electron temperature, for example, agree now within 5%. Moreover, solutions are being addressed to operate some cameras, both visible and IR, even during the full D-T phase to provide imaging of the plasma and the first wall. Various upgrades of neutral particle analysis are being considered, mainly to measure the isotopic composition. A new set of reflectometers is expected to provide valuable information about the changes in the turbulence with the different fuel mixtures. With regard to the fusion products, JET now can deploy a consistent set of techniques to measure the neutron yield and neutron spectra and to diagnose the fast particles. A full calibration of the neutron diagnostics with a 14 MeV source is being considered, after the recent very successful calibration for the 2.45 MeV neutrons. Vertical and horizontal lines of sight are foreseen for neutron and gamma spectrometry, in order to better determine the thermal neutron yield and to separate the trapped and passing components of the alphas. Various gamma ray spectrometers are being developed to cover all the various operational scenarios, from trace tritium to 50-50 D-T operation. The redistribution of the alphas will be measured with the gamma ray cameras, recently upgraded with full digital electronics; new detectors are being considered to bring the time resolution of the system in the ten of ms range. The lost alphas will also be diagnosed with improved spatial and temporal resolution, using Faraday cups and a scintillator probe. From a technological perspective, the D-T campaign will provide a unique opportunity to test ITER relevant technologies. From radiation hard detectors, for example Hall probes, to neutron absorbers and to shielding concepts, the potential of various solutions in a realistic 14 MeV radiation field will be assessed. The effects of neutrons and gamma on ancillary technologies and systems, such as fibre optics and electronics circuits, are also expected to be sufficiently high to derive useful information about the competitive advantage of various alternatives.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proton Radiography: Its uses and Resolution Scaling

Los Alamos National Laboratory has used high energy protons as a probe in flash radiography for over a decade. In this time the proton radiography project has used 800 MeV protons, provided by the LANSCE accelerator facility at LANL, to diagnose over five-hundred dynamic experiments in support of stockpile stewardship programs as well as basic materials science. Through this effort significant experience has been gained in using charged particles as direct radiographic probes to diagnose transient systems. The results of this experience will be discussed through the presentation of data from experiments recently performed at the LANL pRad.

36 MATERIALS SCIENCE↗

Computerized detection of breast cancer on automated breast ultrasound imaging of women with dense breasts

Purpose: Develop a computer-aided detection method and investigate its feasibility for detection of breast cancer in automated 3D ultrasound images of women with dense breasts. Methods: The HIPAA compliant study involved a dataset of volumetric ultrasound image data, “views,” acquired with an automated U-Systems Somo•V{sup ®} ABUS system for 185 asymptomatic women with dense breasts (BI-RADS Composition/Density 3 or 4). For each patient, three whole-breast views (3D image volumes) per breast were acquired. A total of 52 patients had breast cancer (61 cancers), diagnosed through any follow-up at most 365 days after the original screening mammogram. Thirty-one of these patients (32 cancers) had a screening-mammogram with a clinically assigned BI-RADS Assessment Category 1 or 2, i.e., were mammographically negative. All software used for analysis was developed in-house and involved 3 steps: (1) detection of initial tumor candidates, (2) characterization of candidates, and (3) elimination of false-positive candidates. Performance was assessed by calculating the cancer detection sensitivity as a function of the number of “marks” (detections) per view. Results: At a single mark per view, i.e., six marks per patient, the median detection sensitivity by cancer was 50.0% (16/32) ± 6% for patients with a screening mammogram-assigned BI-RADS category 1 or 2—similar to radiologists’ performance sensitivity (49.9%) for this dataset from a prior reader study—and 45.9% (28/61) ± 4% for all patients. Conclusions: Promising detection sensitivity was obtained for the computer on a 3D ultrasound dataset of women with dense breasts at a rate of false-positive detections that may be acceptable for clinical implementation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-H-BRC-08: Examining Credentialing Criteria and Poor Performance Indicators for IROC Houston’s Anthropomorphic Head and Neck Phantom

Purpose: To analyze the most recent results of IROC Houston’s anthropomorphic H&N phantom to determine the nature of failing irradiations and the feasibility of altering pass/fail credentialing criteria. Methods: IROC Houston’s H&N phantom, used for IMRT credentialing for NCI-sponsored clinical trials, requires that an institution’s treatment plan must agree with measurement within 7% (TLD doses) and ≥85% pixels must pass 7%/4 mm gamma analysis. 156 phantom irradiations (November 2014 – October 2015) were re-evaluated using tighter criteria: 1) 5% TLD and 5%/4 mm, 2) 5% TLD and 5%/3 mm, 3) 4% TLD and 4%/4 mm, and 4) 3% TLD and 3%/3 mm. Failure/poor performance rates were evaluated with respect to individual film and TLD performance by location in the phantom. Overall poor phantom results were characterized qualitatively as systematic (dosimetric) errors, setup errors/positional shifts, global but non-systematic errors, and errors affecting only a local region. Results: The pass rate for these phantoms using current criteria is 90%. Substituting criteria 1-4 reduces the overall pass rate to 77%, 70%, 63%, and 37%, respectively. Statistical analyses indicated the probability of noise-induced TLD failure at the 5% criterion was <0.5%. Using criteria 1, TLD results were most often the cause of failure (86% failed TLD while 61% failed film), with most failures identified in the primary PTV (77% cases). Other criteria posed similar results. Irradiations that failed from film only were overwhelmingly associated with phantom shifts/setup errors (≥80% cases). Results failing criteria 1 were primarily diagnosed as systematic: 58% of cases. 11% were setup/positioning errors, 8% were global non-systematic errors, and 22% were local errors. Conclusion: This study demonstrates that 5% TLD and 5%/4 mm gamma criteria may be both practically and theoretically achievable. Further work is necessary to diagnose and resolve dosimetric inaccuracy in these trials, particularly for systematic dose errors. This work is funded by NCI Grant CA180803.

60 APPLIED LIFE SCIENCES↗

Plasma diagnostics from intensities of resonance line series of He-like ions

The possibility of using the relative intensities of the 1snp{sup 1}P{sub 1}–1s{sup 21}S0 transitions with n = 3–6 in He-like multicharged ions to diagnose plasma in a nonstationary ionization state is considered. The calculations performed for F VIII ions show that, at electron temperatures of T{sub e} = 10–100 eV, the intensity ratios are sensitive to the plasma electron density in the range of N{sub e} = 10{sup 16}–10{sup 20} cm{sup –3}. The universal calculated dependences can be used to diagnose various kinds of recombining or ionizing plasmas containing such ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of vaccination on the case fatality rate for COVID-19 infections 2020–2021: multivariate modelling of data from the US Department of Veterans Affairs

Objectives: To evaluate the benefits of vaccination on the case fatality rate (CFR) for COVID-19 infections. Design, setting and participants: The US Department of Veterans Affairs has 130 medical centres. We created multivariate models from these data—339 772 patients with COVID-19—as of 30 September 2021. Outcome measures: The primary outcome for all models was death within 60 days of the diagnosis. Logistic regression was used to derive adjusted ORs for vaccination and infection with Delta versus earlier variants. Models were adjusted for confounding factors, including demographics, comorbidity indices and novel parameters representing prior diagnoses, vital signs/baseline laboratory tests and outpatient treatments. Patients with a Delta infection were divided into eight cohorts based on the time from vaccination to diagnosis. A common model was used to estimate the odds of death associated with vaccination for each cohort relative to that of unvaccinated patients. Results: 9.1% of subjects were vaccinated. 21.5% had the Delta variant. 18 120 patients (5.33%) died within 60 days of their diagnoses. The adjusted OR for a Delta infection was 1.87±0.05, which corresponds to a relative risk (RR) of 1.78. The overall adjusted OR for prior vaccination was 0.280±0.011 corresponding to an RR of 0.291. Raw CFR rose steadily after 10–14 weeks. The OR for vaccination remained stable for 10–34 weeks. Conclusions: Our CFR model controls for the severity of confounding factors and priority of vaccination, rather than solely using the presence of comorbidities. Our results confirm that Delta was more lethal than earlier variants and that vaccination is an effective means of preventing death. After adjusting for major selection biases, we found no evidence that the benefits of vaccination on CFR declined over 34 weeks. We suggest that this model can be used to evaluate vaccines designed for emerging variants.

59 BASIC BIOLOGICAL SCIENCES↗

AIIO: Using Artificial Intelligence for Job-Level and Automatic I/O Performance Bottleneck Diagnosis

Manually diagnosing the I/O performance bottleneck for a single application (hereinafter referred to as the "job level'') is a tedious and error-prone procedure requiring domain scientists to have deep knowledge of complex storage systems. However, existing automatic methods for I/O performance bottleneck diagnosis have one major issue: the granularity of the analysis is at the platform or group level and the diagnosis results cannot be applied to the individual application. To address this issue, we designed and developed a method named "Artificial Intelligence for I/O"(AIIO), which uses AI and its interpretation technology to diagnose I/O performance bottlenecks at the job level automatically. By considering the sparsity of I/O log files, employing multiple AI models for performance prediction, merging diagnosis results across multiple models, and generalizing its performance prediction and diagnosis functions, AIIO can accurately and robustly identify the bottleneck of an even unseen application. Experimental results show that real and unseen applications can use the diagnosis results from AIIO to improve their I/O performance by at most 146 times.

Dong, Bin↗

Troubleshooting deep-learner training data problems using an evolutionary algorithm on Summit

Architectural and hyper-parameter design choices can influence deep-learner (DL) model fidelity but can also be affected by malformed training and validation data. However, practitioners may spend significant time refining layers and hyper-parameters before discovering that distorted training data was impeding training progress. We found that an evolutionary algorithm (EA) can be used to diagnose this kind of DL problem. An EA evaluated thousands of DL configurations on Summit that yielded no overall improvement in DL performance, which suggested problems with the training and validation data. We suspected that Contrast Limited Adaptive Histogram Equalization (CLAHE) enhancement that was applied to previously generated digital surface models (DSMs), for which we were training DLs to find errors, had damaged the training data. Subsequent runs with an alternative global normalization yielded significantly improved DL performance. However, the DL Intersection Over Union (IOU) still exhibited consistent sub-par performance, which suggested further problems with the training data and DL approach. Nonetheless, we were able to diagnose this problem within a 12-hour span via Summit runs, which prevented several weeks of unproductive trial-and-error DL configuration refinement, and allowed for a more timely convergence on an ultimately viable solution.

97 MATHEMATICS AND COMPUTING↗

Detection of Head and Neck Cancer Based on Longitudinal Changes in Serum Protein Abundance

Head and Neck Squamous Cell Carcinoma (HNSCC) is significantly represented in the military population with substantial impact on military operations. Two-thirds of new HNSCC cases are first diagnosed at advanced stage III or IV with lymph node metastases. Thus, there is an urgent need of biomarkers for early detection and risk stratification. Archived serum samples from the Department of Defense Serum Repository provide a unique resource for longitudinal studies of HNSCC in the military and the identification of early detection biomarkers. Methods: We identified 175 patients diagnosed with HNSCC with 175 matched healthy controls and retrieved a total of 978 serum samples drawn at the time of diagnosis, 2 and 4 years prior to diagnosis, and 2 years after diagnosis. Following immunoaffinity depletion, serum samples were analyzed by targeted proteomics assays for multiplexed quantification of a panel of 146 candidate protein biomarkers from the curated literature. Results: We derived a 13-protein signature that distinguishes case versus controls based on longitudinal changes in serum protein concentration. The abundances of each of the 13 proteins remain constant over time in control subjects. The area under the curve for the derived random forest classifier was 0.90. Conclusions: This 13-protein classifier is highly promising for detection of HNSCC prior to overt symptoms. Impact: Use of longitudinal samples has significant potential to identify biomarkers for detection and risk stratification.

59 BASIC BIOLOGICAL SCIENCES↗

Risk Factors and Trends for HPV-Associated Subsequent Malignant Neoplasms among Adolescent and Young Adult Cancer Survivors

Subsequent malignant neoplasms (SMN; new cancers that arise after an original diagnosis) contribute to premature mortality among adolescent and young adult (AYA) cancer survivors. Because of the high population prevalence of human papillomavirus (HPV) infection, we identify demographic and clinical risk factors for HPV-associated SMNs (HPV-SMN) among AYA cancer survivors in the SEER-9 registries diagnosed from 1976 to 2015. Outcomes included any HPV-SMN, oropharyngeal-SMN, and cervical-SMN. Follow-up started 2 months after their original diagnosis. Standardized incidence ratios (SIR) compared risk between AYA survivors and general population. Age-period-cohort (APC) models examined trends over time. Fine and Gray's models identified therapy effects controlling for cancer and demographic confounders. Of 374,408 survivors, 1,369 had an HPV-SMN, occurring on average 5 years after first cancer. Compared with the general population, AYA survivors had 70% increased risk for any HPV-SMN [95% confidence interval (CI), 1.61–1.79] and 117% for oropharyngeal-SMN (95% CI, 2.00–2.35); cervical-SMN risk was generally lower in survivors (SIR, 0.85; 95% CI, 0.76–0.95), but Hispanic AYA survivors had a 8.4 significant increase in cervical-SMN (SIR, 1.46; 95% CI, 1.01–2.06). AYAs first diagnosed with Kaposi sarcoma, leukemia, Hodgkin, and non-Hodgkin lymphoma had increased HPV-SMN risks compared with the general population. Oropharyngeal-SMN incidence declined over time in APC models. Chemotherapy and radiation were associated with any HPV-SMN among survivors with first HPV-related cancers, but not associated among survivors whose first cancers were not HPV-related. HPV-SMN in AYA survivors are driven by oropharyngeal cancers despite temporal declines in oropharyngeal-SMN. Hispanic survivors are at risk for cervical-SMN relative to the general population. Encouraging HPV vaccination and cervical and oral cancer screenings may reduce HPV-SMN burden among AYA survivors.

60 APPLIED LIFE SCIENCES↗

What Sets the Strength of the Middepth Stratification and Overturning Circulation in Eddying Ocean Models?

The processes maintaining stratification in the oceanic middepth (between approximately 1000 and 3000 m) are explored using an eddy-resolving general circulation model composed of a two-hemisphere, semienclosed basin with a zonal reentrant channel in the southernmost eighth of the domain. The middepth region lies below the wind-driven main thermocline but above the diffusively driven abyssal ocean. Here, it is argued that middepth stratification is determined primarily in the model’s Antarctic Circumpolar Current. Competition between mean and eddy overturning in the channel leads to steeper isotherms and thus deeper stratification throughout the basin than would exist without the channel. Isotherms that outcrop only in the channel are nearly horizontal in the semienclosed portion of the domain, whereas isotherms that also outcrop in the Northern Hemisphere deviate from horizontal and are accompanied by geostrophically balanced meridional transport. A northern source of deep water (water with temperatures in the range of those in the channel) leads to the formation of a thick middepth thermostad. Changes in wind forcing over the channel influence the stratification throughout the domain. Since the middepth stratification is controlled by adiabatic dynamics in the channel, it becomes independent of the interior diffusivity κ as κ → 0. The meridional overturning circulation (MOC), as diagnosed by the mean meridional volume transport, also shows a tendency to become independent of κ as κ → 0, whereas the MOC diagnosed by water mass transport shows a continuing dependence on κ as κ → 0. A nonlocal scaling for MOC is created that relates the strength of the northern MOC to the depth of isotherms in the southern channel. Findings of this report compare favorably to observations of large-scale neutral density in the World Ocean.

54 ENVIRONMENTAL SCIENCES↗

Evaluating Entrainment–Mixing Characteristics through Direct Comparisons of Drop Size Distributions Using In Situ Observations from ACE-ENA

Abstract Constraining the impacts of entrainment and associated mixing (i.e., entrainment–mixing) on cloud properties continues to be difficult, partly due to observational uncertainties as well as a lacking consensus of which methodologies for diagnosing entrainment–mixing are most appropriate. This study introduces a novel method to evaluate the presence and degree of inhomogeneous and homogeneous mixing using ∼100 h of in situ observations from a research aircraft over the northeastern Atlantic. Specifically, drop size distributions are compared between regions containing negligible and significant entrainment for select flight legs, making a direct characterization of the degree of homogeneous and inhomogeneous mixing possible. A measure of drop concentration variance is used as a proxy variable to diagnose entrainment–mixing. Results correspond well with entrainment–mixing metrics, showing lower Damköhler numbers where drop size distributions shift toward smaller drop sizes (i.e., inhomogeneous mixing) and greater transition length scales where drop size distributions do not (i.e., homogeneous mixing). Inhomogeneous mixing occurs in most samples from Aerosol and Cloud Experiment in the Eastern North Atlantic (ACE-ENA) (regardless of homogeneous mixing frequencies increasing with increasing spatial resolution from ∼100 to ∼10 m) and is associated with decreased drop size relative dispersion and both greater aerosol and drop concentrations compared with homogeneous mixing. Precipitating clouds have a greater frequency of homogeneous mixing compared with nonprecipitating clouds. The proposed methodology is similarly applied to in situ observations of southeast Pacific stratocumulus, shallow convective clouds over central Oklahoma and low-level clouds over the Southern Ocean. All four locations are primarily dominated by inhomogeneous mixing with minimal variability among each region.

Clouds↗