Temperature and dopant concentration effects on proton light quenching in rare-earth inorganic scintillators [Slides]

Rare-earth inorganic scintillators have characteristics that offer optimal detection qualities for space applications as long a quenching is considered; Incident proton and electron response was measured in four different rare-earth inorganic scintillators of interest; We observed: A temperature effect on quenching for GAGG type detectors. A dopant concentration/decay time effect on quenching for GAGG detectors; Extracting the Birks’ factor for future detectors will improve the analysis of data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ASTM D03 Workshop: Developing a Hydrogen Contamination Detector Analyzer [Slides]

Non-hydrogen constituents in the fuel steam can cause irreversible damage to FC systems and therefore should be avoided. The objectives are: 1. Develop a low-cost fast response device (analyzer) to measure impurities in a dry hydrogen fuel stream at or above the SAE J2719 levels, 2. Develop understanding of a working mechanism and improve the analyzer by identifying the best materials and their configuration, and 3. Test the analyzer in real-world environments.

42 ENGINEERING↗

High spatial resolution charge sensing of quantum Hall states

Charge distribution offers a unique fingerprint of important properties of electronic systems, including dielectric response, charge ordering, and charge fractionalization. Here, we develop an architecture for charge sensing in two-dimensional electronic systems in a strong magnetic field. We probe local change of the chemical potential in a proximitized detector layer using scanning tunneling microscopy, allowing us to infer the chemical potential and the charge profile in the sample. Our technique has both high energy (<0.3 meV) and spatial (<10 nm) resolution exceeding that of previous studies by an order of magnitude. We apply our technique to study the chemical potential of quantum Hall liquids in monolayer graphene under high magnetic fields and their responses to charge impurities. The chemical potential measurement provides a local probe of the thermodynamic gap of quantum Hall ferromagnets and fractional quantum Hall states. The screening charge profile reveals spatially oscillatory response of the quantum Hall liquids to charge impurities and is consistent with the composite Fermi liquid picture close to the half-filling. Our technique also paves the way to map moiré potentials, probe Wigner crystals, and investigate fractional charges in quantum Hall and Chern insulators.

charge sensing↗

Comparison of gamma-ray spectral analysis methods for thick-walled UF 6 cylinders

Three data analysis methods were compared for gamma ray spectra collected by planar and coaxial high-purity germanium detectors (HPGe) on thick-walled uranium hexafluoride cylinders. The cylinder contents range from natural to low-enriched uranium (4.95% 235 U). Each spectrum was analyzed with the traditional 185.7 keV enrichment meter method, a 185.7/1001 keV ratio method, and the Fixed Energy Response Function Analysis with Multiple Efficiency (FRAM) software that utilizes low- and high-energy gamma rays and X-rays. When results for all cylinders were compared, the enrichment meter method and the 185.7/1001 keV peak ratio method consistently provided the most accurate data for all detector types. The error on the enrichment calculations analyzed with FRAM did not meet the international target value whereas those calculated with the enrichment meter and ratio method did. Enrichments calculated by FRAM were found to skew to higher values on natural uranium and to lower values on low-enriched uranium. FRAM calculated the least-precise enrichments; replicate analyses of single cylinders resulted in 235 U values that varied by as much as 19%. FRAM does have the significant advantages in that it does not require the use of calibration cylinders, infinite thickness criteria are not necessary, and it can be applied to any HPGe detector. Finally, if calibration cylinders are available, the enrichment meter and 185.7/1001 peak ratio are the recommended methods as they are the most accurate and precise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the energy response of the ATLAS calorimeter to charged pions from $W^{\pm }\rightarrow \tau ^{\pm }(\rightarrow \pi ^{\pm }\nu _{\tau })\nu _{\tau }$ events in Run 2 data

The energy response of the ATLAS calorimeter is measured for single charged pions with transverse momentum in the range 10 < p T < 300 GeV. The measurement is performed using 139 fb –1 of LHC proton–proton collision data at √s = 13 TeV taken in Run 2 by the ATLAS detector. Charged pions originating from τ-lepton decays are used to provide a sample of high-p T isolated particles, where the composition is known, to test an energy regime that has not previously been probed by in situ single-particle measurements. The calorimeter response to single-pions is observed to be overestimated by ~2% across a large part of the p T spectrum in the central region and underestimated by ~4% in the endcaps in the ATLAS simulation. The uncertainties in the measurements are ≲1% for 15 < p T < 185 GeV in the central region. To investigate the source of the discrepancies, the width of the distribution of the ratio of calorimeter energy to track momentum, the energies per layer and response in the hadronic calorimeter are also compared between data and simulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The throughput calibration of the VERITAS telescopes

Context. The response of imaging atmospheric Cherenkov telescopes to incident γ -ray-initiated showers in the atmosphere changes as the telescopes age due to exposure to light and weather. These aging processes affect the reconstructed energies of the events and γ -ray fluxes. Aims. This work discusses the implementation of signal calibration methods for the Very Energetic Radiation Imaging Telescope Array System (VERITAS) to account for changes in the optical throughput and detector performance over time. Methods. The total throughput of a Cherenkov telescope is the product of camera-dependent factors, such as the photomultiplier tube gains and their quantum efficiencies, and the mirror reflectivity and Winston cone response to incoming radiation. This document summarizes different methods to determine how the camera gains and mirror reflectivity have evolved over time and how we can calibrate this changing throughput in reconstruction pipelines for imaging atmospheric Cherenkov telescopes. The implementation is validated against seven years of observations with the VERITAS telescopes of the Crab Nebula, which is a reference object in very-high-energy astronomy. Results. Regular optical throughput monitoring and the corresponding signal calibrations are found to be critical for the reconstruction of extensive air shower images. The proposed implementation is applied as a correction to the signals of the photomultiplier tubes in the telescope simulation to produce fine-tuned instrument response functions. This method is shown to be effective for calibrating the acquired γ -ray data and for recovering the correct energy of the events and photon fluxes. At the same time, it keeps the computational effort of generating Monte Carlo simulations for instrument response functions affordably low.

79 ASTRONOMY AND ASTROPHYSICS↗

Sensitivity and Detection Limit of Spectroscopic-Grade Perovskite CsPbBr 3 Crystal for Hard X-Ray Detection

We report spectroscopic-grade single crystal detectors can register the energies of individual X-ray interactions enabling photon-counting systems with superior resolution over traditional photoconductive X-ray detection systems. Current technical challenges have limited the preparation of perovskite semiconductors for energy-discrimination X-ray photon-counting detection. Here, this work reports the deployment of a spectroscopic-grade CsPbBr 3 Schottky detector under reverse bias for continuum hard X-ray detection in both the photocurrent and spectroscopic schemes. High surface barriers of approximate to ≈ 1 eV are formed by depositing solid bismuth and gold contacts. The spectroscopic response under a hard X-ray source is assessed in resolving the characteristic X-ray peak. The methodology in enhancing X-ray sensitivity by controlling the X-ray energies and flux, and voltage, is described. The X-ray sensitivity varies between a few tens to over 8000 μC Gy air -1 cm -2 . The detectable dose rate of the CsPbBr 3 detectors is as low as 0.02 nGy air s -1 in the energy discrimination configuration. Finally, the unbiased CsPbBr 3 device forms a spontaneous contact potential difference of about 0.7 V enabling high quality of the CsPbBr 3 single crystals to operate in "passive" self-powered X-ray detection mode and the X-ray sensitivity is estimated as 14 μC Gy air -1 cm -2 . The great potential of spectroscopic-grade CsPbBr 3 devices for X-ray photon-counting systems is anticipated in this work.

36 MATERIALS SCIENCE↗

Calibration and simulation of ionization signal and electronics noise in the ICARUS liquid argon time projection chamber

The ICARUS liquid argon time projection chamber (LArTPC) neutrino detector has been taking physics data since 2022 as part of the Short-Baseline Neutrino (SBN) Program. This paper details the equalization of the response to charge in the ICARUS time projection chamber (TPC), as well as data-driven tuning of the simulation of ionization charge signals and electronics noise. The equalization procedure removes non-uniformities in the ICARUS TPC response to charge in space and time. This work leverages the copious number of cosmic ray muons available to ICARUS at the surface. The ionization signal shape simulation applies a novel procedure that tunes the simulation to match what is measured in data. The end result of the equalization procedure and simulation tuning allows for a comparison of charge measurements in ICARUS between Monte Carlo simulation and data, showing good performance with minimal residual bias between the two.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of Electron Antineutrino Oscillation Amplitude and Frequency via Neutron Capture on Hydrogen at Daya Bay

This Letter reports the first measurement of the oscillation amplitude and frequency of reactor antineutrinos at Daya Bay via neutron capture on hydrogen using 1958 days of data. With over 3.6 million signal candidates, an optimized candidate selection, improved treatment of backgrounds and efficiencies, refined energy calibration, and an energy response model for the capture-on-hydrogen sensitive region, the relative ν ¯ e rates and energy spectra variation among the near and far detectors gives sin 2 2 θ 13 = 0.075 9 − 0.0049 + 0.0050 and Δ m 32 2 = ( 2.7 2 − 0.15 + 0.14 ) × 10 − 3 eV 2 assuming the normal neutrino mass ordering, and Δ m 32 2 = ( − 2.8 3 − 0.14 + 0.15 ) × 10 − 3 eV 2 for the inverted neutrino mass ordering. This estimate of sin 2 2 θ 13 is consistent with and essentially independent from the one obtained using the capture-on-gadolinium sample at Daya Bay. The combination of these two results yields sin 2 2 θ 13 = 0.0833 ± 0.0022 , which represents an 8% relative improvement in precision regarding the Daya Bay full 3158-day capture-on-gadolinium result. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Particle showers detected on ISS in Timepix pixel detectors

We detect regular particle showers in several compact pixel detectors, distributed over the International Space Station. These showers are caused by high energy galactic cosmic rays, with energies often in the 10 s of TeV or higher. We survey the frequency of these events, their dependence on location on ISS, and their independence of the location of ISS, on its orbit. The Timepix detectors used allow individual particle tracks to be resolved, providing a possibility to perform physical analysis of shower events, which we demonstrate. In terms of radiation dosimetry, these showers indicate certain possible limitations of traditional dosimetric measures, in that (a) the dose measured in small sensor may be less than that received in a larger distribution of matter, such as a human and (b) the spatial and temporal extent of these events represents a regime of poorly documented biological response.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of the Mu2e sensitivity to the $\mu^-\rightarrow e^+$ conversion process

The Mu2e experiment at Fermilab (Batavia, IL) will search for the coherent neutrinoless conversion of a muon into an electron in the electric field of an aluminum atom. The conversion process results in a monochromatic electron with energy slightly below the muon rest mass ($E_e= 104.97$ MeV). The experiment goal is to improve the previous measurement by four orders of magnitude and reach a single event sensitivity of $3 \times 10^{-17} $ on the conversion rate with respect to the muon capture rate. \\ The experiment will deliver a very intense pulsed negative muon beam to an aluminum target to achieve a total number of $10^{18}$ stopped muons in three years of running. Production and transport of the muons are accomplished with a sophisticated magnetic system comprised of a Production, a Transport and a Detector solenoid, with the last one hosting a Straw-tube Tracker and a Crystal Calorimeter. The entire detector region is surrounded by a Cosmic Ray Veto system. Mu2e is und er construction at the Muon Campus of Fermilab. \\ The INFN italian group is responsible for the design and construction of the crystal calorimeter, which plays a crucial role in the Mu2e measurement, providing particle identification capabilities fundamental for the rejection of the different background sources that can mimic a conversion electron. The calorimeter information allows also to improve the tracking performances it provides a fast standalone trigger for the experiment.\\ After a long R\&D phase, the final drawings see a calorimeter comprised of 1348 pure CsI crystals arranged in two annular disks. Each crystal is readout by two custom UV-extended Silicon Photomultipliers (SiPMs). Performances of the selected components were verified with an electron beam test, carried out in 2017 at the Beam Test Facility (BTF) at the National Laboratories of Frascati, on a large size prototype of 51 crystals and 102 SiPMs, confirming excellent energy ($\sigma_{E}/E = \mathcal{O }(10\%)$) and timing ($\sigma_{T} <500$ ps) resolutions in a! greement with the Mu2e specifications.\\ In the first chapters of this thesis, I describe my involvement in the calorimeter activities, with particular emphasis on the data analysis of the prototype energy response and resolution, that I was personally leading. Moreover, a description of the tuning of the simulation and the careful data-MC comparison is also reported.\\ An auxiliary measurement that can be performed with Mu2e is the search for a Lepton Number Violation (LNV) process where the negatively charged muon converts, without neutrinos, into a positron, $\mu ^{-} +N(A,Z) \rightarrow $ e$^+ +N(A,Z-2)$. At the moment of writing, Neutrinoless Double Beta Decay (0$\nu \beta \beta$) has set the most stringent limit on the LNV processes (T$^{0\nu \beta \beta}_{1/2} > 1.1 \times 10^{26} $ yr at 90$\%$ CL) with the GERDA experiment. In 0$\nu \beta \beta$ a pair of free electrons is created in the transformation from a nucleus $(A, Z)$ into its daughter $(A, Z + 2)$, namely: $(A,Z)\rightarrow (A, Z+2) =2 e^-$. Similar transitions could proceed through the emission of a pair of positrons, double electron capture (EC), or EC and single emission of a positron, with the nucleus changing from $(A, Z)$ to $(A, Z - 2)$. All these variations are equally interesting when discussing of new Physics, since they all manifest a non-conservation of the number of leptons.\\ Moreover, recent studies show that, because of flavor effect, off-diagonal processes, such as the $\mu^- -e^+$ conversion, can have their rate enhanced with respect to processes occurring in the $e-e$ sector.\\ Mu2e will search for $\mu^- + Al(27,13) \rightarrow e^+ +Na(27,11)$, only considering ground state transition, producing a conversion positron with energy $E_{e^+}= 92.32 $ MeV.\\ This thesis is focused on this search. In particular, I developed an algorithm to account for the radiative corrections to be applied to the conversion positrons that resulted in a few percent reduction in s ignal acceptance.\\ One of the most prominent background to ! this sear! ch is the Radiative Muon Capture (RMC) $ \mu+ N(Z,A)\rightarrow \gamma + \nu_{\mu} + N(Z-1,A)$. The produced photon can convert, virtually or in the detector materials (in the following referred as internal or external conversion respectively) in an electron-positron pair, producing positrons with energies approaching the expected conversion energy. Experimental results from previous experiments indicate the RMC endpoint ($\kmax$) to be of $\sim$ 90 MeV. A precise modeling of this background is relevant due to the proximity of the photon spectrum endpoint to the positron conversion energy. The calorimeter group is obviously interested to reconstruct the RMC distribution having also the opportunity to improve the current knowledge of the process. \\ A toy MC has been developed to evaluate the number of $e^+$ from external RMC background in the signal window. Knowing this value and ev...

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultrafast carrier dynamics in terahertz photoconductors and photomixers: beyond short-carrier-lifetime semiconductors

Abstract Efficient terahertz generation and detection are a key prerequisite for high performance terahertz systems. Major advancements in realizing efficient terahertz emitters and detectors were enabled through photonics-driven semiconductor devices, thanks to the extremely wide bandwidth available at optical frequencies. Through the efficient generation and ultrafast transport of charge carriers within a photo-absorbing semiconductor material, terahertz frequency components are created from the mixing products of the optical frequency components that drive the terahertz device – a process usually referred to as photomixing. The created terahertz frequency components, which are in the physical form of oscillating carrier concentrations, can feed a terahertz antenna and get radiated in case of a terahertz emitter, or mix with an incoming terahertz wave to down-convert to DC or to a low frequency photocurrent in case of a terahertz detector. Realizing terahertz photoconductors typically relies on short-carrier-lifetime semiconductors as the photo-absorbing material, where photocarriers are quickly trapped within one picosecond or less after generation, leading to ultrafast carrier dynamics that facilitates high-frequency device operation. However, while enabling broadband operation, a sub-picosecond lifetime of the photocarriers results in a substantial loss of photoconductive gain and optical responsivity. In addition, growth of short-carrier-lifetime semiconductors in many cases relies on the use of rare elements and non-standard processes with limited accessibility. Therefore, there is a strong motivation to explore and develop alternative techniques for realizing terahertz photomixers that do not rely on these defect-introduced short-carrier-lifetime semiconductors. This review will provide an overview of several promising approaches to realize terahertz emitters and detectors without short-carrier-lifetime semiconductors. These novel approaches utilize p-i-n diode junctions, plasmonic nanostructures, ultrafast spintronics, and low-dimensional materials to offer ultrafast carrier response. These innovative directions have great potentials for extending the applicability and accessibility of the terahertz spectrum for a wide range of applications.

36 MATERIALS SCIENCE↗

Signatures of linearized gravity in atom interferometers: A simplified computational framework

We develop a general framework for calculating the leading-order, general relativistic contributions to the gravitational phase shift in single-photon atom interferometers within the context of linearized gravity. We show that the atom gradiometer observable, which only depends on the atom interferometer propagation phase, can be written in terms of three distinct contributions: the Doppler phase shift, which accounts for the tidal displacement of atoms along the baseline, the Shapiro phase shift, which accounts for the delay in the arrival time of photons at atom-light interaction points, and the Einstein phase shift, which accounts for the gravitational redshift measured by the atoms. For specific atom gradiometer configurations, we derive the signal and response functions for two physically motivated scenarios: (i) transient gravitational waves in the transverse-traceless gauge and, for the first time, in the proper detector frame, and (ii) transient massive objects sourcing weak and slow-varying Newtonian potentials. Here, we find that the Doppler contribution of realistic Newtonian noise sources (e.g., a freight truck or a piece of space debris) at proposed atom gradiometer experiments, such as AION, MAGIS, and AEDGE, can exceed the shot noise level and thus affect physics searches if not properly subtracted. Note: 44 pages including appendices, 4 figures; v2: different formatting, fixed typos, 28 pages including appendices, 5 figures, agrees with published version

Atom interferometry↗

Moderate spectral resolution solar irradiance measurements, aerosol optical depth, and solar transmission, from 360 to 1070 nm, using the refurbished rotating shadow band spectroradiometer (RSS)

Abstract. This paper reports on a third-generation rotating shadow band spectroradiometer (RSS) used to measure global and diffuse horizontal plus direct normal irradiances and transmissions at 1002 wavelengths between 360 and 1070 nm. The prism-dispersed spectral data are from the Atmospheric Radiation Measurement (ARM) Southern Great Plains site in north-central Oklahoma (36.605∘ N, 97.486∘ W) and cover dates between August 2009 and February 2014. The refurbished RSS isolates the detector in a vacuum chamber with pressures near 10−7 torr. This prevents the deposition of outgassed vapors from the interior of the spectrometer shell on the cooled detector that affected the operation of the first commercial RSS. Methods for (1) ensuring the correct wavelength registration of the data and (2) deriving extraterrestrial responses over the entire spectrum, including throughout strong water vapor and oxygen bands, are described. The resulting data produced are archived as ARM data records and include cloud-screened aerosol optical depths, spectral irradiances and direct normal solar transmission, as well as normalized diffuse and global irradiances.

54 ENVIRONMENTAL SCIENCES↗

Investigation of modified uni-traveling carrier photodiode for cryogenic microwave photonic links

Quantum devices present the potential for unparalleled computing and communications capabilities; however, the cryogenic temperatures required to successfully control and read out many qubit platforms can prove to be very challenging to scale. Recently, there has emerged an interest in using microwave photonics to deliver control signals down to ultracold stages via optical fiber, thereby reducing thermal load and facilitating dense wavelength multiplexing. Photodetectors can then convert this optical energy to electrical signals for qubit control. The fidelity of the quantum operations of interest therefore depend heavily upon the characteristics of the photodiode, yet experimental demonstrations of fiber-coupled photodetection systems at low temperatures are relatively few in number, leaving important open questions regarding how specific detectors may perform in real-world cryogenic settings. In this work, we examine a highly linear modified uni-traveling carrier photodiode (MUTC-PD) under C-band illumination (1530–1565 nm) at three temperature regimes (300 K, 80 K, and ∼4 K) and multiple bias conditions. Our findings of reduced responsivity but preserved bandwidth are consistent with previous studies, while our saturation tests suggest a variety of potential applications for MUTC-PDs in cryogenic microwave photonics with and without electrical bias. Overall, our results should provide a valuable foundation for the continued and expanding use of this detector technology in quantum information processing.

47 OTHER INSTRUMENTATION↗

Collective excitations and low-energy ionization signatures of relativistic particles in silicon detectors

Abstract Solid-state detectors with a low energy threshold have several applications, including searches of non-relativistic halo dark-matter particles with sub-GeV masses. When searching for relativistic, beyond-the-Standard-Model particles with enhanced cross sections for small energy transfers, a small detector with a low energy threshold may have better sensitivity than a larger detector with a higher energy threshold. In this paper, we calculate the low-energy ionization spectrum from high-velocity particles scattering in a dielectric material. We consider the full material response including the excitation of bulk plasmons. We generalize the energy-loss function to relativistic kinematics, and benchmark existing tools used for halo dark-matter scattering against electron energy-loss spectroscopy data. Compared to calculations commonly used in the literature, such as the Photo-Absorption-Ionization model or the free-electron model, including collective effects shifts the recoil ionization spectrum towards higher energies, typically peaking around 4–6 electron-hole pairs. We apply our results to the three benchmark examples: millicharged particles produced in a beam, neutrinos with a magnetic dipole moment produced in a reactor, and upscattered dark-matter particles. Our results show that the proper inclusion of collective effects typically enhances a detector’s sensitivity to these particles, since detector backgrounds, such as dark counts, peak at lower energies.

Physics↗

Cryogenic light detectors with thermal signal amplification for 0 νββ search experiments

As a step towards the realization of cryogenic-detector experiments to search for neutrinoless double-beta decay (such as CROSS, BINGO, and CUPID), we investigated a batch of 10 Ge light detectors (LDs) assisted by Neganov-Trofimov-Luke (NTL) signal amplification. Each LD was assembled with a large cubic light-emitting crystal (45 mm side) using the recently developed CROSS mechanical structure. The detector array was operated at milli-Kelvin temperatures in a pulse-tube cryostat at the Canfranc underground laboratory in Spain. We achieved good performance with scintillating bolometers from CROSS, made of Li 2 100 MoO 4 crystals and used as reference detectors of the setup, and with all LDs tested (except for a single device that encountered an electronics issue). No leakage current was observed for 8 LDs with an electrode bias up to 100 V. Operating the LDs at an 80 V electrode bias applied in parallel, we obtained a gain of around 9 in the signal-to-noise ratio of these devices, allowing us to achieve a baseline noise RMS of O(10 eV). Thanks to the strong current polarization of the temperature sensors, the time response of the devices was reduced to around half a millisecond in rise time. The achieved performance of the LDs was extrapolated via simulations of pile-up rejection capability for several configurations of the CUPID detector structure. Despite the sub-optimal noise conditions of the LDs (particularly at high frequencies), we demonstrated that the NTL technology provides a viable solution for background reduction in CUPID.

47 OTHER INSTRUMENTATION↗

Reflectance and fluorescence characteristics of PTFE coated with TPB at visible, UV, and VUV as a function of thickness

Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. In noble element systems, it is often coated with tetraphenyl butadiene (TPB) to allow detection of vacuum ultraviolet scintillation light. Here, in this work this dependence is investigated for PTFE coated with TPB in air for light of wavelengths of 200 nm, 260 nm, and 450 nm. The results show that TPB-coated PTFE has a reflectance of approximately 92% for thicknesses ranging from 5 mm to 10 mm at 450 nm, with negligible variation as a function of thickness within this range. A cross-check of these results using an argon chamber supports the conclusion that the change in thickness from 5 mm to 10 mm does not affect significantly the light response at 128 nm. Our results indicate that pieces of TPB-coated PTFE thinner than the typical 10 mm can be used in particle physics detectors without compromising the light signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗