Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Advances in Detector-Integrated Filter Coatings for the Far Ultraviolet

We report on the continued development of multilayer optical coatings on back-illuminated silicon imaging sensors in order to enhance the functionality of such systems at ultraviolet wavelengths. This includes the development metal-dielectric filter structures to enable solar-blind operation, and graded thickness coatings to tune the spatial response of a detector system to the dispersion of a spectrometer. Such systems can maintain the high internal quantum efficiency afforded by the delta-doping process utilized at NASA JPL, while also providing long-wavelength rejection or a spatially optimized efficiency (or both). We present the characterization of CCD and CMOS image sensors incorporating these processes, and describe the atomic layer deposition coating processes. Such detectors are currently being developed for ground-based high energy physics applications as well as NASA orbital astrophysics instruments operating at wavelengths shorter than 200 nm.

Nikzad, Shouleh↗

Spacecraft Smoke Detector Characterization with Reference and Smoke Aerosols

Performance testing of consumer smoke detectors requires specific facilities and experiments with smoldering and flaming emissions from different fuels. Smoke detectors for use in spacecraft are tested using similar setups with representative fuel materials. To simplify smoke detector testing, this study explored the use of laboratory-generated reference aerosols as transfer standards to evaluate smoke detector performance. Among the three tested reference aerosols, mineral oil particles were reproducibly generated with a Gemini smoke detector tester, dioctyl sebacate (DOS) particles were generated with a wide concentration range and flexible size distributions using an atomizer, while polystyrene latex(PSL) particles were difficult to produce with the high concentrations needed for smoke detector testing. Reference aerosols generated from 1.5%–100% DOS solutions and mineral oil covered the response range of six types of smoke aerosols generated by oxidative pyrolysis of spacecraft-relevant materials. Although no single reference aerosol can be used to simulate the response of different smoke detection technologies to different smoke aerosols within ±10% error, the relationship between reference and smoke aerosols derived from this study can be used to predict smoke detector responses to combustion aerosols.

Smoke↗

The calculation of radial dose from heavy ions: predictions of biological action cross sections

The track structure model of heavy ion cross sections was developed by Katz and co-workers in the 1960s. In this model the action cross section is evaluated by mapping the dose-response of a detector to gamma rays (modeled from biological target theory) onto the radial dose distribution from delta rays about the path of the ion. This is taken to yield the radial distribution of probability for a "hit" (an interaction leading to an observable end-point). Radial integration of the probability yields the cross section. When different response from ions of different Z having the same stopping power is observed this model may be indicated. Since the 1960s there have been several developments in the computation of the radial dose distribution, in the measurement of these distributions, and in new radiobiological data against which to test the model. The earliest model, by Butts and Katz made use of simplified delta ray distribution functions, of simplified electron range-energy relations, and neglected angular distributions. Nevertheless it made possible the calculation of cross sections for the inactivation of enzymes and viruses, and allowed extension to tracks in nuclear emulsions and other detectors and to biological cells. It set the pattern for models of observable effects in the matter through which the ion passed. Here we outline subsequent calculations of radial dose which make use of improved knowledge of the electron emission spectrum, the electron range-energy relation, the angular distribution, and some considerations of molecular excitation, of particular interest both close to the path of the ion and the outer limits of electron penetration. These are applied to the modeling of action cross sections for the inactivation of several strains of E-coli and B. subtilis spores where extensive measurements in the "thin-down" region have been made with heavy ion beams. Such calculations serve to test the radial dose calculations at the outer limit of electron penetration. We lack data from which to test these calculations in regions close to the path of the ion aside from our earliest work on latent tracks in plastics, though it appears that the criterion then suggested for the threshold of track formation, of a minimal dose at a minimal distance (of about 20 angstroms, in plastics), remains valid.

NASA Discipline Radiation Health↗

The CLAS12 Backward Angle Neutron Detector (BAND)

The Backward Angle Neutron Detector (BAND) of CLAS12 detects neutrons emitted at backward angles of 155° to 175°, with momenta between 200 and 600 MeV$/c_0$. It is positioned 3-m upstream of the target, consists of 18 rows and 5 layers of 7.2-cm by 7.2-cm scintillator bars, and read out on both ends by PMTs to measure time and energy deposition in the scintillator layers. Between the target and BAND there is a 2-cm thick lead wall followed by a 2-cm veto layer to suppress gammas and reject charged particles. This paper discusses the component-selection tests and the detector assembly. Timing calibrations (including offsets and time-walk) were performed using a novel pulsed-laser calibration system, resulting in time resolutions better than 250 ps (150 ps) for energy depositions above 2 MeV (5 MeV). Cosmic rays and a variety of radioactive sources were used to calibration the energy response of the detector. Scintillator bar attenuation lengths were measured. We report the time resolution results in a neutron momentum reconstruction resolution, $δp/p$ < 1.5% for neutron momentum 200 ≤ $p$ ≤ 600 MeV/c. Final performance of the BAND with CLAS12 is shown, including electron–neutral particle timing spectra and a discussion of the off-time neutral contamination as a function of energy deposition threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IRAS comet observations - The continuing saga

IRAS observations of comets include photometry, spectroscopy, and multiple wavelength imagery. The large beam of the IRAS detector array, which was well suited to detect faint extended emissions of cometary origin, has produced a large data set that is complex to analyze. Although some preliminary results of the IRAS comet photometry have been published, definitive analysis must explicitly account for the convolution of the emission source with the nonuniform spatial response of the detector array. This paper reviews the progress made toward the production and subsequent analysis of instrument-free comet images, and presents the current state of the art IRAS images of comet Kopff.

Walker, R. G.↗

Air-bridge microbolometer for far-infrared detection

A new microbolometer for far-infrared detection has been fabricated that allows an increase in sensitivity of a factor of 4 over the best previously reported bolometer. By suspending the detector in the air above its substrate, a reduction in the thermal conductance out of the device by a factor of 5 has been achieved. At a modulation frequency of 100 kHz this microbolometer has an electrical noise equivalent power 28 pW/sq rt Hz. A thermal model is also presented that accurately fits the response of the detector.

Neikirk, D. P.↗

Comparative Soot Diagnostics: Preliminary Results

The motivation for the Comparative Soot Diagnostics (CSD) experiment lies in the broad practical importance of understanding combustion generated particulate. Depending upon the circumstances, particulate matter can affect the durability and performance of combustion equipment, can be a pollutant, can be used to detect fires and, in the form of soot, can be the dominant source of radiant energy from flames. The nonbuoyant structure of most flames of practical interest makes understanding of soot processes in low gravity flames important to our ability to predict fire behavior on earth. These studies also have direct applications to fire safety in human-crew spacecraft, since smoke is the indicator used for automated detection in current spacecraft. In the earliest missions (Mercury, Gemini and Apollo), the crew quarters were so cramped that it was considered reasonable that the astronauts would rapidly detect any fire. The Skylab module, however, included approximately 20 UV-sensing fire detectors. The Space Shuttle has 9 particle-ionization smoke detectors in the mid-deck and flight deck and Spacelab has six additional particle-ionization smoke detectors. The designated detectors for the ISS are laser-diode, forward-scattering, smoke or particulate detectors. Current plans for the ISS call for two detectors in the open area of the module, and detectors in racks that have both cooling air flow and electrical power. Due to the complete absence of data concerning the nature of particulate and radiant emission from incipient and fully developed low-g fires, all three of these detector systems were designed based upon l-g test data and experience. As planned mission durations and complexity increase and the volume of spacecraft increases, the need for and importance of effective, crew-independent, fire detection grows significantly. To provide this level of protection, more knowledge is needed concerning low-gravity fire phenomena and, in particular, how they might be detected and suppressed. Prior to CSD, no combustion-generated particulate samples had been collected near the flame zone for well-developed microgravity flames. All of the extant data either came from drop tower tests and therefore only corresponded to the early stages of a fire or were collected far from the flame zone. The fuel sources in the drop tower tests were restricted to laminar gas-jet diffusion flames and very rapidly overheated wire insulation. The gas-jet tests indicated, through thermophoretic sampling, (2) that soot primaries and aggregates (groups of primary particles) in low-gravity may be significantly larger than those in normal gravity (1-g). This raises new scientific questions about soot processes as well as practical issues for particulate size sensitivity and detection alarm threshold levels used in on-orbit smoke detectors. Preliminary tests in the 2.2 second drop tower suggest that particulate generated by overheated wire insulation may be larger in low-g than in 1-g. Transmission Electron Microscope (TEM) grids downstream of the fire region in the Wire Insulation Flammability experiment as well as visual observation of long string-like aggregates, further confirm this suggestion. The combined impact of these limited results and theoretical predictions is that, as opposed to extrapolation from l-g data, direct knowledge of low-g combustion particulate is needed for more confident design of smoke detectors for spacecraft. This paper describes the operation and preliminary results of the CSD, a project conceived and developed at NASA Lewis Research Center. The CSD flight experiment was conducted in the Middeck Glovebox Facility (MGBX) on USMP-3. The project is support by NASA Headquarters Microgravity Science and Applications Division and Code Q. The results presented here are from the microgravity portion of the experiment, including the temporal response of the detectors and average sizes of the primary and aggregate particles captured on the thermophoretic probes.

Urban, David L.↗

Toward the implementation of self-powered, wireless, real-time reactor power sensing

The successful development of real-time, self-powered, wireless reactor power sensing technology would enable key operating parameters of every fuel assembly in a commercial reactor core to be continuously monitored, and potentially be utilized for applications such as closed-loop reactor control. This paper discusses the expansion of successful work on the application of Self Powered Neutron Detectors (SPND) for reactor power monitoring and the wireless transmission of these detector signals using advanced vacuum micro-electronic (VME) transmitter technology developed by Westinghouse in collaboration with the Penn State University Radiation Science and Engineering Center. Results demonstrate that this technology may be successfully applied via long-term testing in the Penn State TRIGA reactor. SPND are inherently slower than, for example, ion chambers due to their dependence on radioactive decay to generate a signal. Additional research developed delay compensation algorithms to accelerate the response of these detectors for use in near-real-time closed-loop reactor control. Initial results indicate that practical signal acceleration can be obtained digitally or with an equivalent analog circuit. Future research will apply an inverse model of the sensor’s balance differential equations to more-effectively accelerate the SPND signal. Use of inverse models will also prove to be adaptive in the sense that time-dependent burn-up of these detectors, due to neutron activation of the detector material, can be modeled and applied in the acceleration algorithm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fixed Source Sensitivity Calculations for Inertial Confinement Fusion Applications

A numerical code library was developed for the radiation transport code MCNP6.3 to calculate generalized response sensitivity coefficients for fixed source neutron transport problems with applications to inertial confinement fusion (ICF) experiments. The new MCNP6.3 dependency is used to generate a novel time convolution response that represents a neutron time-of-flight (nToF) signal. The traditional suite of macroscopic cross-section sensitivities and constrained fixed source probability distribution sensitivities are available for both the standard and the new response tallies in this library. However, novel sensitivity coefficients for the constrained hyperparameters of analytic fixed source probability distributions are emphasized in this work for their connection to ICF neutron transport models. Particularly, advanced Monte Carlo methods are developed for calculating the sensitivity of a nToF signal to perturbations in an ICF plasma’s ion temperature and burn history as well as perturbations in the target liner mass density and the shape parameters of the nToF detector’s impulse response function. Together, these capabilities form an advanced suite of computational tools that can be used to analyze and extract information from any ICF experimental platform.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization and description of a spectrum unfolding method for the $\mathrm{CATRiNA}$ neutron detector array

We report the CATRiNA deuterated neutron detector array at Florida State University consists of 16 2" x 2" and 16 $" x 2" EJ-315 detectors with characteristic light output and pulse-shape discrimination capabilities. The unique properties of the detectors, in part due to the anisotropic nature of (d,n) scattering, are used to extract the energy of neutrons via pulse-height spectrum unfolding. The unfolding method uses the light output and response matrix of the detectors to extract neutron energies, independent of the traditional time-of-flight (ToF) technique. Detailed response matrices of the CATRiNA detectors were measured at the Edwards Accelerator Laboratory at Ohio University via the 9 Be(d,n) and 27 Al(d,n) reactions. Full characterization of the detectors using digital electronics, as well as a description of the unfolding method are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent Developments in Quantum-Well Infrared Photodetectors

Intrinsic infrared (IR) detectors in the long wavelength range (8-20 Am) are based on an optically excited interband transition, which promotes an electron across the band gap (E(sub g)) from the valence band to the conduction band as shown. These photoelectrons can be collected efficiently, thereby producing a photocurrent in the external circuit. Since the incoming photon has to promote an electron from the valence band to the conduction band, the energy of the photon (h(sub upsilon)) must be higher than the E(sub g) of the photosensitive material. Therefore, the spectral response of the detectors can be controlled by controlling the E(sub g) of the photosensitive material. Examples for such materials are Hg(1-x), Cd(x), Te, and Pb(1-x), Sn(x), Te, in which the energy gap can be controlled by varying x. This means detection of very-long-wavelength IR radiation up to 20 microns requires small band gaps down to 62 meV. It is well known that these low band gap materials, characterized by weak bonding and low melting points, are more difficult to grow and process than large-band gap semiconductors such as GaAs. These difficulties motivate the exploration of utilizing the intersub-band transitions in multiquantum well (MQW) structures made of more refractory large-band gap semiconductors. The idea of using MQW structures to detect IR radiation can be explained by using the basic principles of quantum mechanics. The quantum well is equivalent to the well-known particle in a box problem in quantum mechanics, which can be solved by the time independent Schroudiner equation.

Gunapala, S. D.↗

Methods of use for sensor based fluid detection devices

Methods of use and devices for detecting analyte in fluid. A system for detecting an analyte in a fluid is described comprising a substrate having a sensor comprising a first organic material and a second organic material where the sensor has a response to permeation by an analyte. A detector is operatively associated with the sensor. Further, a fluid delivery appliance is operatively associated with the sensor. The sensor device has information storage and processing equipment, which is operably connected with the device. This device compares a response from the detector with a stored ideal response to detect the presence of analyte. An integrated system for detecting an analyte in a fluid is also described where the sensing device, detector, information storage and processing device, and fluid delivery device are incorporated in a substrate. Methods for use for the above system are also described where the first organic material and a second organic material are sensed and the analyte is detected with a detector operatively associated with the sensor. The method provides for a device, which delivers fluid to the sensor and measures the response of the sensor with the detector. Further, the response is compared to a stored ideal response for the analyte to determine the presence of the analyte. In different embodiments, the fluid measured may be a gaseous fluid, a liquid, or a fluid extracted from a solid. Methods of fluid delivery for each embodiment are accordingly provided.

Lewis, Nathan S.↗

HaloSat – A CubeSat that Studied the Hot Galactic Halo

HaloSat was the first CubeSat competitively funded by NASA's Astrophysics Division. HaloSat surveyed the sky in the soft (0.4-2 keV) band with the goal of studying diffuse X-ray emission from highly ionized oxygen in the circumgalactic medium (CGM) of the Milky Way (MW). The HaloSat science instrument (shown above ) contained three nominally identical X-ray detectors. The field of view had full response over a 10° diameter, tapering to zero response at 14° diameter. The detectors were sensitive in the 0.4-7 keV band. Typical halo spectra are shown below. The figure of merit for observing diffuse emission, survey grasp, is the product of effective area and solid angle of the field of view, AΩ. HaloSat has a small effective area, but a large field of view, giving it a grasp competitive with major missions. HaloSat’s grasp (17.6 cm 2 deg 2 at 600 eV) was larger than Chandra’s at launch (8.7 cm 2 deg 2 ). HaloSat data are archived at the HEASARC by a collaboration between NASA/MSFC, UI, and GSFC. See poster 104.01 by Jesse Bluem for details. HaloSat was built and operated by the University of Iowa (UI), NASA/GSFC, Johns Hopkins University, the Laboratoire Atmosphères, Observations Spatiales (LATMOS), and Blue Canyon Technologies.

HaloSat↗

Comparative Soot Diagnostics: 1 Year Report

The motivation for the Comparative Soot Diagnostics (CSD) experiment lies in the broad practical importance of understanding combustion generated particulate. Depending upon the circumstances, particulate matter can affect the durability and performance of combustion equipment, can be a pollutant, can be used to detect fires and, in the form of soot, can be the dominant source of radiant energy from flames. Bright sooty fires are desirable for efficient energy extraction in furnaces and power equipment. In contrast, soot-enhanced radiation is undesirable in many propulsion systems (e.g. jet engines). The non-buoyant structure of most flames of practical interest (turbulent) makes understanding of soot processes in low gravity flames important to our ability to predict fire behavior on earth. These studies also have direct applications to fire safety in human-crew spacecraft, since smoke is the indicator used for automated detection in current spacecraft. In addition, recent tests conducted on MIR showed that a candle in a truly quiescent spacecraft environment can burn for tens of minutes. Consequently, this test and many earlier tests have demonstrated that fires in spacecraft can be considered a credible risk. In anticipation of this risk, NASA has included fire detectors on Skylab, smoke detectors on the Space Shuttle (STS), and smoke detectors in the design for the International Space Station (ISS). In the CSD experiment, these smoke detectors were tested using, quasi-steady, low-gravity, particulate generating materials. Samples of the particulate were also obtained from these low-gravity sources. This experiment provides the first such measurements aimed toward understanding of soot processes here on earth and for the testing and design of advanced spacecraft smoke detection systems. This paper describes the operation and preliminary results of the CSD experiment which was was conducted in the Middeck Glovebox Facility (MGBX) on USMP-3. The objectives of CSD are to examine the particulate emission from a variety of pyrolyzing and combusting sources and to quantify the performance of several particulate-sensing diagnostic techniques. This paper presents the results of the microgravity portion of the CSD experiment. The results include the temporal response of the detectors and average sizes of the primary and aggregate particles captured on the thermophoretic probes. Complete assessment of the microgravity data and its combination with the normal-gravity data are still in process.

Urban, David L.↗

Fast, Large Area, Wide Band GAP UV Photodetector for Cherenkov Light Detection

A solid-state radiation detector includes a pattern of conductive metal on a zinc oxide substrate. The pattern provides an arrangement of interdigitated electrode fingers. The wide band gap substrate is sensitive to UV light, which can cause a conductivity change in the substrate. The electrode fingers are configured to sense a difference in substrate conductivity resulting from UV light. The detector has a fast response time, which enables it to detect Cherenkov light. The compact detector provides savings on size, weight, and required power. Thus, the solid-state detector can be used to replace photomultiplier tubes in Cherenkov detectors. The features of the novel detector allow for an improved system to detect and monitor UV radiation, especially during deep space missions.

Wrbanek, John D.↗

MODIS Solar Diffuser Attenuation Screen Modeling Results

On-orbit calibration of the reflected solar bands on the EOS Moderate Resolution Imaging Spectroradiometer (MODIS) is accomplished by have the instrument view a high reflectance diffuse surface illuminated by the sun. For some of the spectral bands this proves to be much too bright a signal that results in the saturation of detectors designed for measuring low reflectance (ocean) surfaces signals. A mechanical attenuation device in the form of a pin hole screen is used to reduce the signals to calibrate these bands. The sensor response to solar illumination of the SD with and without the attenuation screen in place will be presented. The MODIS detector response to the solar diffuser is smooth when the attenuation screen is absent, but has structures up to a few percent when the attenuation screen is present. This structure corresponds to non-uniform illumination from the solar diffuser. Each pin hole produces a pin-hole image of the sun on the solar diffuser, and there are very many pin hole images of the sun on the solar diffuser for each MODIS detector. Even though there are very many pin-hole images of the sun on the solar diffuser, it is no longer perfectly uniformly illuminated. This non-uniformly illuminated solar diffuser produces intensity variation on the focal planes. The results of a very detailed simulation will be discussed which show how the illumination of the focal plane changes as a result of the attenuation, and the impacts on the calibration will be discussed.

Waluschka, Eugene↗

Performance characterization of 5×5×12 mm 3 virtual Frisch-grid TlBr detectors

Thallium bromide (TlBr) is a promising material for semiconductor gamma-ray detectors due to its high atomic number (Tl = 81, Br = 35), high density (7.56 g/cm 3 ), and relatively low melting point (460 °C). These properties give TlBr several competitive features, including high detection efficiency, good energy resolution, and lower fabrication costs, making it suitable for applications requiring compact, highly sensitive gamma-ray detection systems. Recent developments of TlBr detectors have progressed toward thicker crystals, up to 10–20 mm, configured as pixelated or virtual Frisch-grid (VFG) devices with volumes >1 cm 3 . Despite these advances, challenges remain in practical implementation, including material and fabrication issues that affect energy resolution, device stability, performance, and longevity. These challenges are similar to those faced by HgI 2 and lead-halide perovskite detectors. Here, this study presents results from characterizing over 100 position-sensitive 5×5×12 mm 3 virtual Frisch-grid detectors fabricated by Radiation Monitoring Devices Inc. For a prototype Radioisotope Identification Device (RIID). The work identified factors limiting the performance and longevity of TlBr detectors, including stochastic response variations that limit the energy resolution to 2–3 % (at 662 keV) for most devices, performance degradation associated with defect decoration, and contact delamination. Addressing these issues advances the use of TlBr and similar materials for reliable, high-resolution gamma-ray spectroscopy.

47 OTHER INSTRUMENTATION↗