Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

New detector for use in fast neutron radiography

We have developed and tested a new type detector for use in the fast neutron (FN) imaging radiography applications. FN radiography is generally used for nondestructive material testing, medical and biology applications, border patrol, transportation and cargo screening tasks. It is complementary to other types of radiography, providing additional information on light element content of the material samples. Distinct from other FN imagers presently known, our device implements a neutron-sensitive scintillator attached to a position-sensitive photomultiplier tube (PSPMT), and operates in an event-by-event readout mode, acquiring energy, timing, and pulse shape information for all detected radiation events. The information is used to help separate events of FN interactions in the scintillator from the background events caused by the electronics noise and by the other types of background radiation. Selection of pure fast neutron events in the final image allows us to achieve ultimate image contrast and resolution, as compared with other types of FN imaging devices operating most commonly in an integration mode, in which the detector?s dark noise and radiation background dilute the images. The detector performance for FN imaging application was tested using D-D neutron generator, designed and manufactured by Adelphi Technology, Inc. This essentially point-like neutron source operates in continuous mode producing up to 109 of 2.5 MeV neutrons per second. Samples made of metals plastic and other material were used to measure the detector resolution, efficiency and uniformity. Results of these tests are presented and discussed. Fig. 1 shows one of the test FN radiographic images obtained using the sample made of 11 styrene plastic strips. All strips are squares 4.8 x 4.8 mm2 with six different lengths 10 to 60 mm with 10 mm increment. [A] [B] [C] Fig. 1. [A]-layout of the test sample; [B]-raw FN shadow image of the sample; [C]-map of the plastic strips as they appear on the image, with measured FN absorption factor shown in percent. Both X and Y position resolution of the FN imaging detector are estimated to be less than 0.5 mm (sigma) based on the analysis of the edges of the strip shadows in the plot. Because this detector shows the fraction-of-a-millimeter resolution desirable for most of FN applications, and is built using radiation hard materials, we believe it could be a good alternative to other FN imaging systems based on CCD or solid state detectors. In addition, having a sub-nanosecond timing resolution, it is suitable for the time-of-flight energy-resolved FN imaging.

Popov, V.↗

Improved Growth Methods for LaBr3 Scintillation Radiation Detectors

The objective is to develop advanced materials for deployment as high-resolution gamma ray detectors. Both LaBr3 and CeBr3 are advanced scintillation materials, and will be studied in this research. Prototype devices, in collaboration Sandia National Laboratories, will be demonstrated along with recommendations for mass production and deployment. It is anticipated that improved methods of crystal growth will yield larger single crystals of LaBr3 for deployable room-temperature operated gamma radiation spectrometers. The growth methods will be characterized. The LaBr3 and CeBr3 scintillation crystals will be characterized for light yield, spectral resolution, and for hardness.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Collecting data in the home laboratory: evolution of X-ray sources, detectors and working practices

Recent developments in X-ray crystallographic hardware related to structural biology research are presented and discussed. While the majority of macromolecular X-ray data are currently collected using highly efficient beamlines at an ever-increasing number of synchrotrons, there is still a need for high-performance reliable systems for in-house experiments. In addition to crystal screening and optimization of data-collection parameters before a synchrotron trip, the home system allows the collection of data as soon as the crystals are produced to obtain the solution of novel structures, especially by the molecular-replacement method, and is invaluable in achieving the quick turnover that is often required for ligand-binding studies in the pharmaceutical industry. There has been a continuous evolution of X-ray sources, detectors and software developed for in-house use in recent years and a diverse range of tools for structural biology laboratories are available. An overview of the main directions of these developments and examples of specific solutions available to the macromolecular crystallography community are presented in this paper, showing that data collection ‘at home’ is still an attractive proposition complementing the use of synchrotron beamlines.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A novel muon detector for borehole density tomography

Muons can be used to image the density of materials through which they pass, including geological structures. Subsurface applications of the technology include tracking fluid migration during injection or production, with increasing concern regarding such timely issues as induced seismicity or chemical leakage into aquifers. Current density monitoring options include gravimetric data collection and active or passive seismic surveys. One alternative, or complement, to these methods is the development of a muon detector that is sufficiently compact and robust for deployment in a borehole. Such a muon detector can enable imaging of density structure to monitor small changes in density – a proxy for fluid migration – at depths up to 1500 m. Such a detector has been developed, and Monte Carlo modeling methods applied to simulate the anticipated detector response. Testing and measurements using a prototype detector in the laboratory and shallow underground laboratory demonstrated robust response. Lastly, a satisfactory comparison with a large drift tube-based muon detector is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, construction, operation and performance of a Hadron Blind Detector for the PHENIX experiment

A Hadron Blind Detector (HBD) has been developed, constructed and successfully operated within the PHENIX detector at RHIC. The HBD is a Cherenkov detector operated with pure CF{sub 4}. It has a 50 cm long radiator directly coupled in a windowless configuration to a readout element consisting of a triple GEM stack, with a CsI photocathode evaporated on the top surface of the top GEM and pad readout at the bottom of the stack. This paper gives a comprehensive account of the construction, operation and in-beam performance of the detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detection of high frequency intensity oscillations at RESEDA using the CASCADE detector

We have explored the technological potential of combining neutron resonance spin echo (NRSE) with the time-of-flight method in quasielastic neutron scattering (QENS) experiments. For these test measurements at the new NRSE instrument RESEDA (FRM II, Munich), we have employed CASCADE, one of the fastest neutron detectors in the world, developed at the University of Heidelberg. Conventionally, scintillation detectors are used, in order to detect neutron intensities with high time resolution. In contrast, we used the new CASCADE detector converting neutrons in thin {sup 10}B layers being capable of resolving neutron intensity modulations up to the megahertz regime. This fast detector allows us to abandon the last resonance flip coil of a standard NRSE setup. The classical spin echo signal is replaced by a time-modulated signal. In this setup, fast intensity modulations are present at the detector position. In order to demonstrate, that NRSE-CASCADE operates well up to detector frequencies of 10 MHz, we performed elastic polarization test measurements on a standard sample. The CASCADE detector is a multidetector accumulating counts in 128 x 128 pixels on a surface of 200 mm x 200 mm. We have analyzed the signal in 600 pixels, providing information about the spin phase reaching the detector and about the resolution function of this new variant tested at RESEDA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fine-tuning machine-learned particle-flow reconstruction for new detector geometries in future colliders

We demonstrate transfer learning capabilities in a machine-learned algorithm trained for particle-flow reconstruction in high energy particle colliders. This paper presents a cross-detector fine-tuning study, where we initially pretrain the model on a large full simulation dataset from one detector design, and subsequently fine-tune the model on a sample with a different collider and detector design. Specifically, we use the Compact Linear Collider detector (CLICdet) model for the initial training set and demonstrate successful knowledge transfer to the CLIC-like detector (CLD) proposed for the Future Circular Collider in electron-positron mode. We show that with an order of magnitude less samples from the second dataset, we can achieve the same performance as a costly training from scratch, across particle-level and event-level performance metrics, including jet and missing transverse momentum resolution. Furthermore, we find that the fine-tuned model achieves comparable performance to the traditional rule-based particle-flow approach on event-level metrics after training on 100,000 CLD events, whereas a model trained from scratch requires at least 1 million CLD events to achieve similar reconstruction performance. To our knowledge, this represents the first full-simulation cross-detector transfer learning study for particle-flow reconstruction. These findings offer valuable insights towards building large foundation models that can be fine-tuned across different detector designs and geometries, helping to accelerate the development cycle for new detectors and opening the door to rapid detector design and optimization using machine learning.

43 PARTICLE ACCELERATORS↗

Task I: Dark Matter Search Experiments with Cryogenic Detectors: CDMS-I and CDMS-II Task II: Experimental Study of Neutrino Properties: EXO and KamLAND

Dark Matter Search - During the period of performance, our group continued the search for dark matter in the form of weakly interacting massive particles or WIMPs. As a key member of the CDMS (Cryogenic Dark Matter Search) collaboration, we completed the CDMS II experiment which led the field in sensitivity for more than five years. We fabricated all detectors, and participated in detector testing and verification. In addition, we participated in the construction and operation of the facility at the Soudan Underground Laboratory and played key roles in the data acquisition and analysis. Towards the end of the performance period, we began operating the SuperCDMS Soudan experiment, which consists of 15 advanced Ge (9 kg) detectors. The advanced detector design called iZIP grew out of our earlier DOE Particle Detector R&D program which demonstrated the rejection of surface electrons to levels where they are no longer the dominant source of background. Our group invented this advanced design and these larger detectors were fabricated on the Stanford campus in collaboration with the SLAC CDMS group and the Santa Clara University group. The sensitivity reach is expected to be up to 5 times better than CDMS II after two years of operation. We will check the new limits on WIMPs set by XENON100, and we expect improved sensitivity for light mass WIMPs beyond that of any other existing experiment. Our group includes the Spokesperson for SuperCDMS and continues to make important contributions to improvements in the detector technology which are enabling the very low trigger thresholds used to explore the low mass WIMP region. We are making detailed measurements of the charge transport and trapping within Ge crystals, measuring the diffusive trapping distance of the quasiparticle excitations within the Al phonon collector fins on the detector surface, and we are contributing to the development of much improved detector Monte Carlos which are essential to guide the detector design and optimize the analysis. Neutrino Physics – In the period of performance the neutrino group successfully completed the construction of EXO-200 and commissioned the detector. Science data taking started on Jun 1, 2011. With the discovery of the 2-neutrino double-beta decay in 136-Xe and the first measurement of the 0-neutrino mode resulting in the most stringent limit of Majorana masses, our group continues to be a leading innovator in the field of neutrino physics which is central to DOE-HEP Intensity Frontier program. The phenomenon of neutrino oscillations, in part elucidated by our earlier efforts with the Palo Verde and KamLAND experiments, provides the crucial information that neutrino masses are non-zero and, yet, it contains no information on the value of the neutrino mass scale. In recent times our group has therefore shifted its focus to a high sensitivity 0-neutrino double beta decay program, EXO. The 0-neutrino double beta decay provides the best chance of extending the sensitivity to the neutrino mass scale below 10 meV but, maybe more importantly, it tests the nature of the neutrino wave function, providing the most sensitive probe for Majorana particles and lepton number violation. The EXO program, formulated by our group several years ago, plans to use up to tonnes of the isotope 136-Xe to study the 0-neutrino double beta decay mode. The EXO-200 detector is the first step in this program and it represents the only large US-led and based experiment taking data. The EXO-200 isotope enrichment program broke new grounds for the enterprise of double beta decay. The detector design and material selection program paid off, resulting in a background that is among the very best in the field. The “first light" of EXO-200 was very exciting with the discovery -in the first month of data- of the rarest 2-neutrino double beta decay mode ever observed. The lower limit on the 0-neutrino double beta decay half-life, published in Phys. Rev. Lett. and based on the first 120 days of data is the second best but, when translated into a Majorana mass scale, it is one of the most stringent constraint we have on neutrino masses. Indeed, such a limit was the first result to contradict a claim of discovery in 76-Ge for most nuclear matrix elements calculations. As we continue data taking and plan some modest upgrades to EXO-200 our group is also very active in the design of nEXO, a 5 tonne detector based on the technology demonstrated by EXO-200. Over the years we have made it a tradition to explore the frontier and not to be shy about looking in new directions and re-inventing ourselves to best take advantage of the precious few opportunities provided by Nature. We have also cultivated a number of young people at all levels and, by now, many of the undergraduates, graduate students and postdocs educated by this group have leading positions in academia and industry around the world.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analyzing Noise for the Muon Silicon Scanner

The development of a silicon muon tomography detector is a joint project between Fermilab and National Security Technologies, LLC. The goal of this detector is to detect nuclear materials better than technology in the past. Using silicon strip detectors and readout chips used by experiments at CERN we have been developing the detector. This summer we have been testing components of the detector and have been analyzing noise characteristics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of Rayleigh Scattering in Liquid Argon at Vacuum Ultraviolet Wavelengths

Liquid argon based experiments are limited in scintillation light analysis capabilities due to inconsistent measured values of fundamental constants essential for reconstructing scintillation events. This experiment measures the Rayleigh scattering length of vacuum ultraviolet light propagating in liquid argon to support liquid argon experiments by expanding the scope of scintillation signal analysis. Preliminary results are presented for the Rayleigh scattering length in arange of vacuum ultraviolet wavelengths, including the liquid argon scintillation peak wavelength. Currently, further data collection and analysis is required to reduce measurement uncertainty as well as quantify and correct for other effects such as the photon detector temperature dependence. Results will contribute to the development of new photon detector system analysis methods for liquid argon experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cherenkov Water Detectors in Particle Physics and Cosmic Rays

Among various types of Cherenkov detectors (solid, liquid and gaseous) created for different studies, the most impressive development was gained by water detectors: from the first detector with a volume of several liters in which the Cherenkov radiation was discovered, to the IceCube detector with a volume of one cubic kilometer. The review of the development of Cherenkov water detectors for various purposes and having different locations − ground-based, underground and underwater–is presented in the paper. The prospects of their further development are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Test of a prototype neutron spectrometer based on diamond detectors in a fast reactor

A prototype of neutron spectrometer based on diamond detectors has been developed. This prototype consists of a {sup 6}Li neutron converter sandwiched between two CVD diamond crystals. The radiation hardness of the diamond crystals makes it suitable for applications in low power research reactors, while a low sensitivity to gamma rays and low leakage current of the detector permit to reach good energy resolution. A fast coincidence between two crystals is used to reject background. The detector was read out using two different electronic chains connected to it by a few meters of cable. The first chain was based on conventional charge-sensitive amplifiers, the other used a custom fast charge amplifier developed for this purpose. The prototype has been tested at various neutron sources and showed its practicability. In particular, the detector was calibrated in a TRIGA thermal reactor (LENA laboratory, University of Pavia) with neutron fluxes of 10{sup 8} n/cm{sup 2}s and at the 3 MeV D-D monochromatic neutron source named FNG (ENEA, Rome) with neutron fluxes of 10{sup 6} n/cm{sup 2}s. The neutron spectrum measurement was performed at the TAPIRO fast research reactor (ENEA, Casaccia) with fluxes of 10{sup 9} n/cm{sup 2}s. The obtained spectra were compared to Monte Carlo simulations, modeling detector response with MCNP and Geant4. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modeling of the photodetector based on the multilayer graphene nanoribbons

Graphene nanoribbon (GNR), which has unique properties and advantages, is a crucial component of nanoelectornic devices, especially in the development of photoelectric detectors. In this work, an infrared photodetector based on the structure of stacked multiple-GNRs, which is separated by a little thick barrier layers (made of tungsten disulfide or related materials) to prevent tunneling current, is proposed and modeled. Operation of photoelectric detector is related to the electron cascaded radiative transition in the adjacent GNRs strengthened by the electrons heated due to the incident light. With a developed model, the working principle is analyzed and the relationships for the photocurrent and dark current as functions of the intensity of the incident radiation are derived. The spectral dependence of the responsivity and detectivity for graphene nanoribbons photodetector (GNRs-PT) with different Fermi energy, band gaps and numbers of GNRs layers are analyzed as well. The results demonstrate that the spectral characteristics depend on the GNRs band gap, which shows a potential on GNRs-PT application in the multi-wavelength systems. In addition, GNRs-PT has a better spectrum property and higher responsivity compared to photodetectors based on In{sub x}Ga{sub x}As in room temperature.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Unsupervised Learning for Improved Gamma-Ray Spectrometry in Pixelated Cadmium Zinc Telluride (CZT) Detectors

Machine learning has been found to be ubiquitously useful across many industries, presenting an opportunity to improve radiation detection performance using data-driven algorithms. Improved detector resolution can aid in the detection, identification, and quantification of radionuclides. Here, in this work, a novel, data-driven, unsupervised learning approach is developed to improve detector spectral characteristics by learning, and subsequently rejecting, poorly performing regions of the pixelated detector. Feature engineering is used to fit individual characteristic photo peaks to a Doniach lineshape with a linear background model. Then, principal component analysis is used to learn a lower-dimension latent space representation of each photo peak where the pixels are clustered, and subsequently ranked, based on the cluster mean distance to an optimal point. Pixels within the worst cluster(s) are rejected to improve the full-width at half-maximum (FWHM) by 10% to 15% (relative to the bulk detector) at 50% net efficiency when applied to training data obtained from measurements of a 100 μCi 154 Eu source using a H3D M400i pixelated cadmium zinc telluride detector. These results compare well with, but do not outperform, a greedy algorithm that accumulates pixels in order of FWHM from lowest to highest used as a benchmark. In the future, this approach can be extended to include the detector energy and angular response. Finally, the model is applied to newly seen natural and enriched uranium spectra relevant for nuclear safeguards applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a double-sided silicon strip detector autoradiography system

Purpose: The most commonly used technology currently used for autoradiography is storage phosphor screens, which has many benefits such as a large field of view but lacks particle-counting detection of the time and energy of each detected radionuclide decay. A number of alternative designs, using either solid state or scintillator detectors, have been developed to address these issues. The aim of this study is to characterize the imaging performance of one such instrument, a double-sided silicon strip detector (DSSD) system for digital autoradiography. A novel aspect of this work is that the instrument, in contrast to previous prototype systems using the same detector type, provides the ability for user accessible imaging with higher throughput. Studies were performed to compare its spatial resolution to that of storage phosphor screens and test the implementation of multiradionuclide ex vivo imaging in a mouse preclinical animal study. Methods: Detector background counts were determined by measuring a nonradioactive sample slide for 52 h. Energy spectra and detection efficiency were measured for seven commonly used radionuclides under representative conditions for tissue imaging. System dead time was measured by imaging {sup 18}F samples of at least 5 kBq and studying the changes in count rate over time. A line source of {sup 58}Co was manufactured by irradiating a 10 μm nickel wire with fast neutrons in a research reactor. Samples of this wire were imaged in both the DSSD and storage phosphor screen systems and the full width at half maximum (FWHM) measured for the line profiles. Multiradionuclide imaging was employed in a two animal study to examine the intratumoral distribution of a {sup 125}I-labeled monoclonal antibody and a {sup 131}I-labeled engineered fragment (diabody) injected in the same mouse, both targeting carcinoembryonic antigen. Results: Detector background was 1.81 × 10{sup −6} counts per second per 50 × 50 μm pixel. Energy spectra and detection efficiency were successfully measured for seven radionuclides. The system dead time was measured to be 59 μs, and FWHM for a {sup 58}Co line source was 154 ± 14 μm for the DSSD system and 343 ± 15 μm for the storage phosphor system. Separation of the contributions from {sup 125}I and {sup 131}I was performed on autoradiography images of tumor sections. Conclusions: This study has shown that a DSSD system can be beneficially applied for digital autoradiography with simultaneous multiradionuclide imaging capability. The system has a low background signal, ability to image both low and high activity samples, and a good energy resolution.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The GALILEO γ-ray array at the Legnaro National Laboratories

GALILEO, a new 4 pi high-resolution gamma-detection array, based on HPGe detectors, has been developed and installed at the Legnaro National Laboratories. The GALILEO array greatly benefits from a fully-digital readout chain, customized DAQ, and a variety of complementary detectors to improve the resolving power by the detection of particles, ions or high-energy gamma-ray transitions. In this paper, a full description of the array, including electronics and DAQ, is presented together with its complementary instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HIBP Applications to Advance Understanding of Plasma Transport Physics (2011-2017) (and subsequently titled) Development of Beam Measurements to Advance Understanding of Transients and Improve Validation (2017-2020) (Final Technical Report)

This is the Final Technical Report for the DoE Measurement Innovation (previously Diagnostic Development) grant DE-SC0006077 titled HIBP Applications to Advance Understanding of Plasma Transport Physics (2011-2017), and subsequently titled Development of Beam Measurements to Advance Understanding of Transients and Improve Validation (2017-2020). The grant was funded by the Office of Fusion Energy Sciences (FES) for the period 1 May 2011–17 July 2020. Work performed through the grant has resulted in diagnostic innovations and new measurement capabilities that will improve understanding of transport, magnetic equilibrium, and electric fields in magnetically confined plasmas. We have developed novel hardware and advanced techniques to expand beam-based diagnostic capabilities, and extend measurements to new operating regimes. Some have been realized using a Heavy Ion Beam Probe (HIBP) having traditional features, while other applications have joined our innovations with subsets of advantageous HIBP features. This work has established smaller, more economical detection systems and, in doing so, may enable substantial extension of scenarios in which beam-based diagnostics are deployed. Key Measurement Innovations include: Computer Models and Simulations of HIBP Applications-Computer modeling and simulating of HIBP applications is central to predicting interaction of beam particles with plasmas, designing diagnostic systems, and anticipating measurement characteristics. We have extended the capability and improved measurement fidelity of the HIBP diagnostic on the Madison Symmetric Torus (MST) reversed field pinch (RFP); simulated feasibility of HIBP operation in the Helically Symmetric eXperiment (HSX) optimized stellarator; and investigated the plausibility of HIBP measurements in the ASDEX Upgrade tokamak. We have also developed a new technique that uses ion optics to model a finite phase-space beam. It yields more realistic (than traditional method) estimates of sample volume characteristics, which influence measurement resolution and sensitivity. Extension of Diagnostic Capabilities and Measurements on the MST RFP-Capabilities have been extended using the first and only HIBP installation on an RFP. Challenges associated with operation of the diagnostic on MST include the three-dimensional nature of particle trajectories, temporal topology and amplitude changes in the plasma equilibrium, and strong particle and radiative emission from the plasma. We have addressed these challenges through development of detailed and higher precision diagnostic simulations, calibrated subtraction of noise to resolve secondary ion signals, and implementation of hardware that enables higher fidelity measurement of plasma fluctuations. Development of New Hardware and Measurement Techniques - We have advanced beam-based measurement capabilities via development of new detectors and techniques to determine the poloidal magnetic flux ψ in the plasma, and enable placement of detectors close to the plasma and thus allow a smaller and less expensive diagnostic. We have demonstrated measurement of ψ, an ability that was made possible by development of highly effective noise reduction techniques. We also modeled the effect of non-ideal and instrumentation effects by developing a virtual (simulated) diagnostic. Application of beam-based diagnostics on various devices and multiple magnetic configurations (e.g. stellarator, tokamak, and reversed field pinch) enables investigation of critical physics issues and measurements resulting in the broad parameter space data needed to test and validate theory & modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-Element Germanium Detectors with Integrated Readouts

In this study, we have developed a series of monolithic multi-element germanium detectors coupled with custom developed CMOS application specific integrated circuit (ASIC) for readout. Several strip detectors with element counts ranging from 64 to 384 were developed and are currently used at the National Synchrotron Light Source II in Brookhaven National Laboratory and the Advanced Photon Source in Argonne National Laboratory. Lastly, the detectors are photon counting and are used at high-energy diffraction and energy dispersive diffraction beamlines.

47 OTHER INSTRUMENTATION↗