Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data requests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Experimental Determination and Thermodynamic Modeling of Electrical Conductivity of SRS Waste Tank Supernate

SRS High Level Waste Tank Farm personnel rely on conductivity probes for detection of incipient overflow conditions in waste tanks. Minimal information is available concerning the sensitivity that must be achieved such that that liquid detection is assured. Overly sensitive electronics results in numerous nuisance alarms for these safety-related instruments. In order to determine the minimum sensitivity required of the probe, Tank Farm Engineering personnel need adequate conductivity data to improve the existing designs. Little or no measurements of liquid waste conductivity exist; however, the liquid phase of the waste consists of inorganic electrolytes for which the conductivity may be calculated. Savannah River Remediation (SRR) Tank Farm Facility Engineering requested SRNL to determine the conductivity of the supernate resident in SRS waste Tank 40 experimentally as well as computationally. In addition, SRNL was requested to develop a correlation, if possible, that would be generally applicable to liquid waste resident in SRS waste tanks. A waste sample from Tank 40 was analyzed for composition and electrical conductivity as shown in Table 4-6, Table 4-7, and Table 4-9. The conductivity for undiluted Tank 40 sample was 0.087 S/cm. The accuracy of OLI Analyzer™ was determined using available literature data. Overall, 95% of computed estimates of electrical conductivity are within ±15% of literature values for component concentrations from 0 to 15 M and temperatures from 0 to 125 °C. Though the computational results are generally in good agreement with the measured data, a small portion of literature data deviates as much as ±76%. A simplified model was created that can be used readily to estimate electrical conductivity of waste solution in computer spreadsheets. The variability of this simplified approach deviates up to 140% from measured values. Generally, this model can be applied to estimate the conductivity within a factor of two. The comparison of the simplified model to pure component literature data suggests that the simplified model will tend to under estimate the electrical conductivity. Comparison of the computed Tank 40 conductivity with the measured conductivity shows good agreement within the range of deviation identified based on pure component literature data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data Sharing Report for the Quantification of Removable Activity in Various Surveillance and Maintenance Facilities at the Oak Ridge National Laboratory Oak Ridge TN

The U.S. Department of Energy (DOE) Oak Ridge Office of Environmental Management (OR-EM) requested that Oak Ridge Associated Universities (ORAU), working under the Oak Ridge Institute for Science and Education (ORISE) contract, provide technical and independent waste management planning support using American Recovery and Reinvestment Act (ARRA) funds. Specifically, DOE OR-EM requested that ORAU plan and implement a sampling and analysis campaign targeting potential removable radiological contamination that may be transferrable to future personal protective equipment (PPE) and contamination control materials—collectively referred to as PPE throughout the remainder of this report—used in certain URS|CH2M Oak Ridge, LLC (UCOR) Surveillance and Maintenance (S&M) Project facilities at the Oak Ridge National Laboratory (ORNL). Routine surveys in Bldgs. 3001, 3005, 3010, 3028, 3029, 3038, 3042, 3517, 4507, and 7500 continuously generate PPE. The waste is comprised of Tyvek coveralls, gloves, booties, Herculite, and other materials used to prevent worker exposure or the spread of contamination during routine maintenance and monitoring activities. This report describes the effort to collect and quantify removable activity that may be used by the ORNL S&M Project team to develop radiation instrumentation “screening criteria.” Material potentially containing removable activity was collected on smears, including both masselin large-area wipes (LAWs) and standard paper smears, and analyzed for site-related constituents (SRCs) in an analytical laboratory. The screening criteria, if approved, may be used to expedite waste disposition of relatively clean PPE. The ultimate objectives of this effort were to: 1) determine whether screening criteria can be developed for these facilities, and 2) provide process knowledge information for future site planners. The screening criteria, if calculated, must be formally approved by Federal Facility Agreement parties prior to use for ORNL S&M Project PPE disposal at the Environmental Management Waste Management Facility (EMWMF). ORAU executed the approved sampling and analysis plan (SAP) (DOE 2013) while closely coordinating with ORNL S&M Project personnel and using guidelines outlined in the Waste Handling Plan for Surveillance and Maintenance Activities at the Oak Ridge National Laboratory, DOE/OR/01-2565&D2 (WHP) (DOE 2012). WHP guidelines were followed because the PPE waste targeted by this SAP is consistent with that addressed under the approved Waste Lot (WL) 108.1 profile for disposal at EMWMF—this PPE is a “future waste stream” as defined in the WHP. The SAP presents sampling strategy and methodology, sample selection guidelines, and analytical guidelines and requirements necessary for characterizing future ORNL S&M Project PPE waste. This report presents a review of the sample and analysis methods including data quality objectives (DQOs), required deviations from the original design, summary of field activities, radiation measurement data, analytical laboratory results, a brief presentation of results, and process knowledge summaries.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Middleware Case Study: MeDICi

In many application domains in science and engineering, data produced by sensors, instruments and networks is naturally processed by software applications structured as a pipeline . Pipelines comprise a sequence of software components that progressively process discrete units of data to produce a desired outcome. For example, in a Web crawler that is extracting semantics from text on Web sites, the first stage in the pipeline might be to remove all HTML tags to leave only the raw text of the document. The second step may parse the raw text to break it down into its constituent grammatical parts, such as nouns, verbs and so on. Subsequent steps may look for names of people or places, interesting events or times so documents can be sequenced on a time line. Each of these steps can be written as a specialized program that works in isolation with other steps in the pipeline. In many applications, simple linear software pipelines are sufficient. However, more complex applications require topologies that contain forks and joins, creating pipelines comprising branches where parallel execution is desirable. It is also increasingly common for pipelines to process very large files or high volume data streams which impose end-to-end performance constraints. Additionally, processes in a pipeline may have specific execution requirements and hence need to be distributed as services across a heterogeneous computing and data management infrastructure. From a software engineering perspective, these more complex pipelines become problematic to implement. While simple linear pipelines can be built using minimal infrastructure such as scripting languages, complex topologies and large, high volume data processing requires suitable abstractions, run-time infrastructures and development tools to construct pipelines with the desired qualities-of-service and flexibility to evolve to handle new requirements. The above summarizes the reasons we created the MeDICi Integration Framework (MIF) that is designed for creating high-performance, scalable and modifiable software pipelines. MIF exploits a low friction, robust, open source middleware platform and extends it with component and service-based programmatic interfaces that make implementing complex pipelines simple. The MIF run-time automatically handles queues between pipeline elements in order to handle request bursts, and automatically executes multiple instances of pipeline elements to increase pipeline throughput. Distributed pipeline elements are supported using a range of configurable communications protocols, and the MIF interfaces provide efficient mechanisms for moving data directly between two distributed pipeline elements.

99 GENERAL AND MISCELLANEOUS↗

Performance of CUDA Unified Memory in CMS Heterogeneous Pixel Reconstruction

The management of separate memory spaces of CPUs and GPUs brings an additional burden to the development of software for GPUs. To help with this, CUDA unified memory provides a single address space that can be accessed from both CPU and GPU. The automatic data transfer mechanism is based on page faults generated by the memory accesses. This mechanism has a performance cost, that can be with explicit memory prefetch requests. Various hints on the inteded usage of the memory regions can also be given to further improve the performance. The overall effect of unified memory compared to an explicit memory management can depend heavily on the application. In this paper we evaluate the performance impact of CUDA unified memory using the heterogeneous pixel reconstruction code from the CMS experiment as a realistic use case of a GPU-targeting HEP reconstruction software. We also compare the programming model using CUDA unified memory to the explicit management of separate CPU and GPU memory spaces.

Kortelainen, Matti J.↗

MO-FG-213-04: Managing the Relationship

Academic-industrial collaborations are playing an increasingly prominent role in medical physics research. Successful partnerships have enabled truly translational, benchtop-to-bedside research that has significantly and positively impacted our field. Given the current flat or depleting trends in federal funding, and the increasing emphasis in the medical physics community on demonstrating translatability, efficacy, and safety prior to widespread clinical use, it is anticipated that such partnerships will become ever more important in advancing our field. In the future, it is likely that neither academia alone, nor industry alone, will be able to bring significant innovation to successfully impact patient care in radiotherapy. Such innovation will require partnership and symbiosis through the lifetime of the project. This symposium is aimed at professionals from academia and the industry who are interested in either initiating new collaborations or maintaining and improving existing partnerships. We will hear from four thought leaders from industry and academia on critical aspects of building and maintaining successful academic-industrial research partnerships. The following topics will be addressed: 1. Motivations: The industry perspective [Kevin Brown, Elekta] What goes into the development of a company’s R&D roadmap What are the motivations and expectations of the industry from academic partners How can academics make a successful pitch by identifying projects aligned with a company’s roadmap Why are some relationships successful and some not Milestones and progress reports - Why do we need them 2. Motivations: The academic perspective [T. Rock Mackie, Univ. of Madison, WI; Tomotherapy] What are the motivations and expectations of academic partners from the industry What are the cultural differences in academia vs industry on sharing information, exchanging ideas Partnership or entrepreneurship? When does each option make sense 3. Industrial Grants and Research Contracts – a Primer [Norbert Pelc; Stanford University] What topics are suited to industrial grants vs. academic grants How do resources (personnel effort, tuition) get allocated and charged in academia What are reasonable resource and timeline requests for small and big projects; from small and big companies “Fair market value” considerations Sections of a research agreement (IP including software confidential information, publications, data, exclusivity, support) 4. Managing the relationship [John Wong, Johns Hopkins University] How to effectively collaborate with each other How to adapt to changes in the relationship How to renew funding with the industry Moderated Panel Discussion [All speakers + moderators] Learning Objectives: 1. Understand the motivations of each partner 2. Elements that contribute to a successful partnership 3. Avoiding pitfalls - Challenges on either side that may derail a project 4. How to frame a research grant and agreement 5. How to sustain the collaborative relationship Amit Sawant: Funding from: NIH. Varian, Elekta and VisionRT; Michelle Svatos: Employee and shareholder: Varian, Board Member, TopasMC; Kevin Brown: Employee, Elekta; T. Rock Mackie: Consultant, Accuray; Norbert Pelc: Research support: Philips Healthcare, GE Healthcare; John Wong: Funding from NIH, Xstrahl and Elekta. Co-founder and advisor for JPLC Associates, LLC.

07 ISOTOPE AND RADIATION SOURCES↗

Final Report on C8 Enhanced Surveillance Campaign Milestone L2 4654: Surveillance Metrics Assessments on Selected Weapons

In December 2012, LANL Enhanced Surveillance was tasked with milestone L2 4654 to provide an assessment of the results of the Surveillance Metrics Team approaches to metrics. The goal was to provide an assessment and comparison of the two approaches. The approaches are labeled Approach 1 and Approach 2 based on their order of development. Approach 1 was developed by LLNL (initially December 2009) to be a high level, non data-intensive snapshot for the stockpile health for each system. Approach 2 was a statistically-based approach developed by SNL and LANL over a period from 2009-2012 as a means to analyze Core Surveillance data and answer the question of whether there is an adequate amount of Core Surveillance data. The two approaches are summarized below along with key differences. Both approaches were developed to respond to an August 10, 2009 Dr. Greenaugh memo which requested, “metric(s) describing the results of realized and, non-realized surveillance activities on our confidence in reporting reliability and assessing the stockpile”. Both approaches were developed to satisfy the developers’ interpretation of the memo and be useful for their work. Both approaches are being used by their respective developers and so the memo has caused positive change in surveillance. This report looks at what is reported, possible problems, and some opportunities that exist. This report expands the conventional idea of “non-realized” surveillance activities to include “opportunities” that could allow surveillance activities to improve the confidence in reporting reliabilities. These “non-realized surveillance” opportunities are important to consider along with the current surveillance activities.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Average X-Ray Energy from Optimized Tantalum / Carbon Bremsstrahlung Converters

A set of coupled electron/photon radiation transport calculations were performed on optimized Ta / C converters due to questions about previous work at Sandia National Laboratories by Halbleib and Sanford. Generally, the results of the previous calculations were confirmed. However, new relationships between the incident electron beam energy and the average energy of a bremsstrahlung x-ray spectrum for the converters have been defined for the incident electron energy range of 50 keV to 15 MeV as well as for the narrower range of 50 keV to 1 MeV. The relationships were developed by bracketing the results of radiation transport calculations rather than by a rigorous mathematical fit to the data. Additional data such as the total x-ray or the energy spectra of the x-ray fluence exiting the Ta / C converters are available upon request.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

University of Hawai‘i, Shallow Geothermal Resources: Energy Technology Innovation Partnership Project (Final Report)

Scientists at Lawrence Berkeley National Laboratory (Berkeley Lab) have teamed up with the University of Hawai‘i at Manoa (UH Manoa) through the U.S. Department of Energy’s Energy Technology Innovation Partnership Project to evaluate the technological and market feasibility of shallow geothermal heat exchanger (GHE) technology. UH requested this analysis to evaluate opportunities in building cooling, energy efficiency, and emissions reduction applications in Hawai‘i. UH has an abundance of geologic and geothermal data and is looking to the national labs’ expertise to execute this analysis. UH is also interested in investigating policy, regulatory, and business conditions advantageous for implementation of a pilot project and more broad deployment of this technology in Hawai‘i. In many locations around the world, the demands for heating and cooling are roughly balanced over the course of the year, so GHEs do not cause significant long-term changes in subsurface temperature. This is not the case in Hawai’i, where the demand for heating is very small, meaning that, over time, GHEs will add heat to the subsurface. If temperatures increase significantly, GHE systems will not work as designed. Regional groundwater flow has the potential to sweep heated water away from boreholes, thereby maintaining the functionality of the GHE system. Significant regional groundwater flow requires two things: a sufficiently large driving hydraulic head gradient (usually closely related to surface topography), and sufficient porosity and permeability to enable groundwater to flow in large enough quantities to enable near-borehole temperatures to be maintained at ambient values. Hawai‘i’s volcanic terrain offers ample surface topographic variation. The lava itself shows an extremely large range of porosity and permeability, so sites with large enough values of these properties must be selected. Numerical modeling of coupled groundwater and heat flow can be used to determine how large is large enough. Primarily, closed-loop systems have been investigated. Other options considered are open-loop systems and using cool seawater as the chilling source. Project work investigated the feasibility of GHE technology at two scales. At the island scale, GIS layers of various attributes relevant for GHE were combined to develop an overall favorability map for employing GHE in Hawai‘i. At the local scale, a hydrogeologic model for the subsurface component of a closed-loop system was developed for the Stan Sheriff Center at the UH Manoa campus. This site is considered promising because the rock below and immediately downgradient of the borefield is highly permeable, consisting of a subsurface karst system (limestone containing high-permeability open channels), which is underlain by a thick, high-permeability fractured basalt. Moreover, the site is near the base of the Ko‘olau Range, providing a large hydraulic head gradient. Thus, groundwater flow through the site is expected to be large, enabling efficient removal of heated groundwater. A full-GHE-system model of the site was also developed, with a simplified representation of the subsurface, in which groundwater flow is not considered and heat transfer is purely by conduction. Using the building cooling load data provided by UH, simulation results show that with groundwater flow present, a GHE can operate successfully for at least 10 years, but with no groundwater flow, the subsurface begins to heat up after only one year of operation, making the GHE unviable within 2-6 years. The team also developed a techno-economic model for this site to compare the cost of cooling using a GHE system with the costs of operating the current air-conditioning system. The GHE system is advantageous economically if favorable tax incentives and interest rates can be obtained.

15 GEOTHERMAL ENERGY↗

Indoor Air Quality (IAQ) Monitoring for Space Farming Institute [Slides]

Through the U.S. Department of Energy's Energy to Communities (E2C) program, NREL, other national laboratory experts, and select organizations provide Expert Match - free, short-term technical assistance to address near-term energy challenges and questions. Expert Match is for community stakeholders who have decision-making power or influence in their community but need access to additional energy expertise to inform key upcoming decisions. This Expert Match request supported the Space Farming Institute, a nonprofit organization located in Anchorage, AK, with an indoor air quality analysis. The NREL team analyzed indoor air quality data provided by the Space Farming Institute, which experts at PNNL used to design an indoor bioreactor to grow Ulva algae for indoor air quality mitigation purposes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Industry Level Feasibility of LiDAR Data into Fire Modeling Using Fire Risk Investigation in 3D (FRI3D)

Many evaluation, assessment, and modeling tasks at nuclear power plants require spatial information this often requires physical visits to locations within the facility because the 2D or 3D schematics and current models do not contain enough detail or do not capture as-built and real-world conditions. These visits require extensive manual labor for not only the requesting party, but support groups such as security. LIDAR mapping is trying to solve that problem by providing very detailed 3D models for low costs. However, the use of these models can be very limited because either component reference information is missing and too costly to add, or there is no way to extract specific spatial data needed for other tools. This report presents Idaho National Lab's work with Environmental Intellect (Ei) covering two main efforts. First, to reduce the effort of "tagging" data in large 3D models. By using both existing plant database information, and artificial intelligence (AI) to find and read equipment labels. This research explores the ability of to provide a simple way for the user to tag items and verify plant data, capturing both the speed of AI and human verification. The second part of the work is the development of an interface for importing pieces needed for Modeling & Simulation. Analysis work such as that for fire, flood, or physical security all require spatial or 3D models in various levels of detail. This interface will allow for the retrieval of item location or boundaries, enabling the auto generation of models for varying tools. The application program interface (API) of the fire risk investigation in 3D (FRI3D) was used to test feasibility of exporting the LiDAR tagged spatial information. Outcomes from this work provide preliminary data to determine if the tools and methods could provide substantial industry benefit if fully matured.

97 MATHEMATICS AND COMPUTING↗

Analysis of the Tank 6F Final Characterization Samples-2012 (U)

The Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (SRR) to provide sample preparation and analysis of the Tank 6F final characterization samples to determine the residual tank inventory prior to grouting. Fourteen residual Tank 6F solid samples from three areas on the floor of the tank were collected and delivered to SRNL between May and August 2011. These Tank 6F samples were homogenized and combined into three composite samples based on a proportion compositing scheme and the resulting composite samples were analyzed for radiological, chemical and elemental components. Additional measurements performed on the Tank 6F composite samples include bulk density and water leaching of the solids to account for water soluble components. The composite Tank 6F samples were analyzed and the data reported in triplicate. Sufficient quality assurance standards and blanks were utilized to demonstrate adequate characterization of the Tank 6F samples. The main evaluation criteria were target detection limits specified in the technical task request document. While many of the target detection limits were met for the species characterized for Tank 6F some were not met. In a few cases, the relatively high levels of radioactive species of the same element or a chemically similar element precluded the ability to measure some isotopes to low levels. The isotopes whose detection limits were not met in all cases included Sn-126, Sb-126, Sb-126m, Eu-152, Cm-243 and Cf-249. SRNL, in conjunction with the customer, reviewed all of these cases and determined that the impacts of not meeting the target detection limits were acceptable. Based on the analyses of variance (ANOVA) for the inorganic constituents of Tank 6F, all the inorganic constituents displayed heterogeneity. The inorganic results demonstrated consistent differences across the composite samples: lowest concentrations for Composite Sample 1, intermediate-valued concentrations for Composite Sample 2, and highest concentrations for Composite Sample 3. The Hg and Mo results suggest possible measurement outliers. However, the magnitudes of the differences between the Hg 95% upper confidence limit (UCL95) results with and without the outlier and the magnitudes of the differences between the Mo UCL95 results with and without the outlier do not appear to have practical significance. It is recommended to remove the potential measurement outliers. Doing so is conservative in the sense of producing a higher UCL95 for Hg and Mo than if the potential outliers were included in the calculations. In contrast to the inorganic results, most of the radionuclides did not demonstrate heterogeneity among the three Tank 6F composite sample characterization results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of the Tank 6F Final Characterization Samples-2012

The Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (SRR) to provide sample preparation and analysis of the Tank 6F final characterization samples to determine the residual tank inventory prior to grouting. Fourteen residual Tank 6F solid samples from three areas on the floor of the tank were collected and delivered to SRNL between May and August 2011. These Tank 6F samples were homogenized and combined into three composite samples based on a proportion compositing scheme and the resulting composite samples were analyzed for radiological, chemical and elemental components. Additional measurements performed on the Tank 6F composite samples include bulk density and water leaching of the solids to account for water soluble components. The composite Tank 6F samples were analyzed and the data reported in triplicate. Sufficient quality assurance standards and blanks were utilized to demonstrate adequate characterization of the Tank 6F samples. The main evaluation criteria were target detection limits specified in the technical task request document. While many of the target detection limits were met for the species characterized for Tank 6F some were not met. In a few cases, the relatively high levels of radioactive species of the same element or a chemically similar element precluded the ability to measure some isotopes to low levels. The isotopes whose detection limits were not met in all cases included Sn-126, Sb-126, Sb-126m, Eu-152, Cm- 243 and Cf-249. SRNL, in conjunction with the customer, reviewed all of these cases and determined that the impacts of not meeting the target detection limits were acceptable. Based on the analyses of variance (ANOVA) for the inorganic constituents of Tank 6F, all the inorganic constituents displayed heterogeneity. The inorganic results demonstrated consistent differences across the composite samples: lowest concentrations for Composite Sample 1, intermediate-valued concentrations for Composite Sample 2, and highest concentrations for Composite Sample 3. The Hg and Mo results suggest possible measurement outliers. However, the magnitudes of the differences between the Hg 95% upper confidence limit (UCL95) results with and without the outlier and the magnitudes of the differences between the Mo UCL95 results with and without the outlier do not appear to have practical significance. It is recommended to remove the potential measurement outliers. Doing so is conservative in the sense of producing a higher UCL95 for Hg and Mo than if the potential outliers were included in the calculations. In contrast to the inorganic results, most of the radionuclides did not demonstrate heterogeneity among the three Tank 6F composite sample characterization results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Independent Verification Survey Summary and Results for Sub-Slab Soils Associated with the Former Building K-33, Oak Ridge, Tennessee (Final Report)

At DOE’s request, ORAU conducted confirmatory surveys of the K-33 sub-slab soil during the period of August 2011 through May 2012. The survey activities included visual inspections and measurement and sampling activities. LSRS was forthcoming with information relating to surface scan results. Scans performed by the contractor were of adequate coverage and overall data appear to represent actual site conditions. However, the LSRS technicians failed to identify several areas of elevated direct gamma radiation. Most of the samples taken by ORAU at locations of elevated instrument response were above the remediation concentration for one or more radionuclides of concern (ROC). The contractor was, however, quick to perform additional remediation of areas identified to have contamination above the guidelines. Further investigation by ORAU was not requested once additional remediation was completed. It is presumed the remediation contractor’s future PCCR will present detailed and conclusive evidence that K-33 sub-slab soils either comply or do not comply with record of decision (ROD) criteria. However, ORAU concludes, based on both independent verification (IV) data and data provided by LSRS, that the remediation contractor followed appropriate and applicable procedures and that the associated data adequately represent site conditions.

54 ENVIRONMENTAL SCIENCES↗

Use of an Alternative Conceptual Model of Vadose Zone Heterogeneity to Evaluate Past Tank Leaks and Other Unplanned Releases within a Tank Farm at the Hanford Site - 20061

Washington State Department of Ecology (Ecology) requested that U.S. Department of Energy (DOE)-Office of River Protection (ORP) consider an evaluation of effects of fine-grained thin sediment layers on transport with a separate alternative conceptual model in its evaluation of the potential impact of tank leaks and other unplanned releases within the tank farm at the Hanford Site. For this alternative model, Ecology recommended that the model be developed based on the general framework of fine-grained units identified by a stakeholder group in their interpretations of variability in moisture content data collected in the vicinity of Waste Management Area (WMA) C. In discussions with DOE-ORP, Ecology acknowledged that the underlying data and interpretations of the occurrence and lateral continuity of the fine-grained thin layers identified by a stakeholder group are uncertain. However, DOE-ORP agreed to Ecology's recommendation and has provided support for the requested evaluation that involved development of an alternative model based on the general framework of the unpublished report by the stakeholder. DOE-ORP considered this evaluation to be a hypothetical evaluation of vadose zone heterogeneities at WMA C. General observations from the range of simulation cases examined in the evaluation of the effects of hypothetical vadose zone heterogeneities at WMA C are as follows. - The movement of the center of mass of the simulated plumes was generally vertically downward below the source for all simulations, including those that incorporated the hypothetical fine-grained units. - All simulations that incorporated hypothetical heterogeneity produced additional plume spreading over what was produced in simulations using Equivalent Homogeneous Media (EHM) model(s)a. The spreading resulted in a broadening of the fringes of the plume, resulting in a wider region of low concentration, but lower peak concentrations associated with the center of mass of the plume. - Simulations that used the silty-sand hydraulic properties, suggested by Ecology for the hypothetical fine-grained units, generally produced similar spreading and slightly lower peak mass flux at the water table when compared to the EHM modeling results. a The EHM-based models used at WMA C do not explicitly include small-scale fine-grained heterogeneities used in the model advocated by Ecology. - Simulations that used the silty-sand hydraulic properties, suggested by Ecology for the hypothetical fine-grained units, generally produced less spreading and an earlier arrival of mass flux at the water table when compared to the use of another set of hydraulic properties from a silty-sand sample collected at a nearby disposal facility. - The EHM representation of the vadose zone generally produced higher peak mass flux and an earlier occurrence of peak fluxes at the water table compared to all analyses incorporating additional hypothetical heterogeneity. Results of this alternative model evaluation of past leaks provided some insight into the transport effects of vadose zone heterogeneities at WMA C that helped resolve Ecology's comments and issues related to the effects of vadose zone heterogeneities on past leaks and losses from the WMA C tank farms area. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

REPORTABLE RADIONUCLIDES IN DWPF SLUDGE BATCH 7A (MACROBATCH 8)

The Waste Acceptance Product Specifications (WAPS) 1.2 require that the waste producer 'shall report the curie inventory of radionuclides that have half-lives longer than 10 years and that are, or will be, present in concentrations greater than 0.05 percent of the total inventory for each waste type indexed to the years 2015 and 3115.' As part of the strategy to meet WAPS 1.2, the Defense Waste Processing Facility (DWPF) will report for each waste type all radionuclides that have half-lives longer than 10 years and contribute greater than 0.01 percent of the total curie inventory from the time of production through the 1100 year period from 2015 through 3115. The initial list of radionuclides to be reported is based on the design-basis glass identified in the Waste Form Compliance Plan (WCP) and Waste Form Qualification Report. However, it is required that the list be expanded if other radionuclides with half-lives greater than 10 years are identified that meet the 'greater than 0.01% of the curie inventory' criterion. Specification 1.6 of the WAPS, International Atomic Energy Agency Safeguards Reporting for High Level Waste (HLW), requires that the ratio by weights of the following uranium and plutonium isotopes be reported: U-233, U-234, U-235, U-236, and U-238; and Pu-238, Pu-239, Pu-240, Pu-241, and Pu-242. Therefore, the complete list of reportable radionuclides must also include these sets of U and Pu isotopes - and the U and Pu isotopic mass distributions must be identified. The DWPF receives HLW sludge slurry from Savannah River Site (SRS) Tank 40. For Sludge Batch 7a (SB7a), the waste in Tank 40 contained a blend of the heel from Sludge Batch 6 (SB6) and the Sludge Batch 7 (SB7) material transferred to Tank 40 from Tank 51. This sludge blend is also referred to as Macrobatch 8. Laboratory analyses of a Tank 40 sludge sample were performed to quantify the concentrations of pertinent radionuclides in the SB7a waste. Subsequently, radiological decay and in-growth were calculated over the time period from 2015 to 3115. This provided a basis for characterizing the radionuclide content of SB7a over time and for identifying the 'reportable radionuclides.' Details of the characterization methodology and the analytical results are the focus of this report. This work was performed at the request of the Waste Solidification Engineering Department of Savannah River Remediation, initiated via Technical Task Request (TTR) HLW-DWPF-TTR-2010-0031. A minor revision in the reporting requirements was requested via a subsequent email communication. The work was conducted in accordance with the protocols identified in Task Technical and Quality Assurance Plan SRNL-RP-2010-01218 and Analytical Study Plan SRNL-RP-2010-01219. All of the raw data related to this scope have been recorded in laboratory notebook SRNL-NB-2011-00061. The overall goal of this task was to characterize the radionuclide content of the SB7a waste sufficiently to meet the WAPS and DWPF reporting requirements. The specific objectives were: (1) Quantify the current concentrations of all radionuclides impacting (or potentially-impacting) the total curie content between calendar years 2011 and 3115. Also quantify the current concentrations of other radionuclides specifically requested in the TTR or required by the WAPS. (2) Calculate future concentrations of decayed and in-grown radionuclides impacting the total curie content between calendar years 2015 and 3115; (3) Identify as 'reportable' all radionuclides contributing {ge} 0.01% of the total curie content from 2015 to 3115 and having half-lives {ge} 10 years.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Designing and prototyping extensions to the Message Passing Interface in MPICH

As HPC system architectures and the applications running on them continue to evolve, the MPI standard itself must evolve. The trend in current and future HPC systems toward powerful nodes with multiple CPU cores and multiple GPU accelerators makes efficient support for hybrid programming critical for applications to achieve high performance. However, the support for hybrid programming in the MPI standard has not kept up with recent trends. The MPICH implementation of MPI provides a platform for implementing and experimenting with new proposals and extensions to fill this gap and to gain valuable experience and feedback before the MPI Forum can consider them for standardization. Here, in this work, we detail six extensions implemented in MPICH to increase MPI interoperability with other runtimes, with a specific focus on heterogeneous architectures. First, the extension to MPI generalized requests lets applications integrate asynchronous tasks into MPI’s progress engine. Second, the iovec extension to datatypes lets applications use MPI datatypes as a general-purpose data layout API beyond just MPI communications. Third, a new MPI object, MPIX_Stream, can be used by applications to identify execution contexts beyond MPI processes, including threads and GPU streams. MPIX stream communicators can be created to make existing MPI functions thread-aware and GPU-aware, thus providing applications with explicit ways to achieve higher performance. Fourth, MPIX Streams are extended to support the enqueue semantics for offloading MPI communications onto a GPU stream context. Fifth, thread communicators allow MPI communicators to be constructed with individual threads, thus providing a new level of interoperability between MPI and on-node runtimes such as OpenMP. Lastly, we present an extension to invoke MPI progress, which lets users spawn progress threads with fine-grained control to adapt the communication performance to their application designs. We describe the design and implementation of these extensions, provide usage examples, and highlight their expected benefits with performance results.

97 MATHEMATICS AND COMPUTING↗

The Potosi Reservoir Model 2014

As a part of a larger project co-funded by the United States Department of Energy (US DOE) to evaluate the potential of formations within the Cambro-Ordovician strata above the Mt. Simon Sandstone as potential targets for carbon sequestration in the Illinois and Michigan Basins, the Illinois State Geological Survey (ISGS) requested Schlumberger to evaluate the potential injectivity and carbon dioxide (CO2) plume size of the Cambrian Potosi Formation. The evaluation of this formation was accomplished using wireline data, core data, pressure data, and seismic data from this project as well as two other separately funded projects: the United States Department of Energy-funded Illinois Basin – Decatur Project (IBDP) being conducted by the Midwest Geological Sequestration Consortium (MGSC) in Macon County, Illinois, and the Illinois Industrial Carbon Capture and Sequestration (IL-ICCS) project funded through the American Recovery and Reinvestment Act.

Smith, Valerie↗

The Potosi Reservoir Model 2013

As a part of a larger project co-funded by the United States Department of Energy (US DOE) to evaluate the potential of formations within the Cambro-Ordovician strata above the Mt. Simon as potential targets for carbon sequestration in the Illinois and Michigan Basins, the Illinois Clean Coal Institute (ICCI) requested Schlumberger to evaluate the potential injectivity and carbon dioxide (CO2) plume size of the Cambrian Potosi Formation. The evaluation of this formation was accomplished using wireline data, core data, pressure data, and seismic data from the US DOE-funded Illinois Basin–Decatur Project (IBDP) being conducted by the Midwest Geological Sequestration Consortium in Macon County, Illinois. In 2010, technical performance evaluations on the Cambrian Potosi Formation were performed through reservoir modeling. The data included formation tops from mud logs, well logs from the VW1 and the CCS1 wells, structural and stratigraphic formation from three dimensional (3D) seismic data, and field data from several waste water injection wells for Potosi Formation. Intention was for two million tons per annum (MTPA) of CO2 to be injected for 20 years. In the preceding, the 2010 Potosi heterogeneous model (referred to as the "Potosi Dynamic Model 2010" in this topical report) was re-run using a new injection scenario; 3.2 MTPA for 30 years. The extent of the Potosi Dynamic Model 2010, however, appeared too small for the new injection target. It was not sufficiently large enough to accommodate the evolution of the plume. The new model, Potosi Dynamic Model 2013a, was built by extending the Potosi Dynamic Model 2010 grid to 30 miles x 30 miles (48.3km x48.3km), while preserving all property modeling workflows and layering. This model was retained as the base case of Potosi Dynamic Model 2013a. The Potosi reservoir model was updated to take into account the new data from the verification well VW2 which was drilled in 2012. The new porosity and permeability modeling was performed to take into account the log data from the new well. Revisions of the 2010 modeling assumptions were also done on relative permeability, capillary pressures, formation water salinity, and the maximum allowable well bottomhole pressure. Dynamic simulations were run using the injection target of 3.2 MTPA for 30 years. This new dynamic model was named Potosi Dynamic Model 2013b. Due to the major uncertainties on the vugs permeability, two models were built; the Pessimistic and Optimistic Cases. The Optimistic Case assumes vugs permeability of 9,000 mD, which is analog to the vugs permeability identified in the pressure fall off test of a waste water injector in the Tuscola site, approx. 40 miles (64.4km) away from the IBDP area. The Pessimistic Case assumes that the vugs permeability is equal to the log data, which does not take into account the permeability from secondary porosity. The probability of such case is deemed low and could be treated as the worst case scenario, since the contribution of secondary porosity to the permeability is neglected and the loss circulation events might correspond to a much higher permeability. It is considered important, however, to identify the range of possible reservoir performance since there are no rigorous data available for the vugs permeability. The Optimistic Case gives an average CO2 injection rate of 0.8 MTPA and cumulative injection of 26 MT in 30 years, which corresponds to 27% of the injection target. The injection rate is approx. 3.2 MTPA in the first year as the well is injecting into the surrounding vugs, and declines rapidly to 0.8 MTPA in year 4 once the surrounding vugs are full and the CO2 start to reach the matrix. This implies that according to this preliminary model, a minimum of four (4) wells could be required to achieve the injection target. This result is lower than the injectivity estimated in the Potosi Dynamic Model 2013a (43 MT in 30 years), since the permeability model applied in the Potosi Dynamic Model 2013b is more conservative. This revision was deemed necessary to treat the uncertainty in a more appropriate manner. As the CO2 follows the paths where vugs interconnection exists, a reasonably large and irregular plume extent was created. For the Optimistic Case, the plume extends 17 miles (27.4km) in E-W and 14 miles (22.5km) in N-S directions after 30 years. After injection is completed, the plume continues to migrate laterally, mainly driven by the remaining pressure gradient. After 100 years post injection, the plume extends 20 miles (32.2km) in E-W and 15.5 miles (24.9km) in N-S directions. Should the targeted cumulative injection of 96 MT be achieved; a much larger plume extent could be expected. For the Optimistic Case, the increase of reservoir pressure at the end of injection is approximately 1200 psia (8,274 kPa) around the injector and gradually decreases away from the well. The reservoir pressure increase is less than 30 psia (206.8 kPa) beyond 14 miles (22.5km) away from injector. Should the targeted cumulative injection of 96 MT be achieved; a much larger areal pressure increase could be expected. The initial reservoir pressure is nearly restored after approximately 100 years post injection. The presence of matrix slows down the pressure dissipations. The Pessimistic Case gives an average CO2 injection rate of 0.2 MTPA and cumulative injection of 7 MT in 30 years, which corresponds to 7% of the injection target. This implies that in the worst case scenario, a minimum of sixteen (16) wells could be required to achieve the injection target. The present evaluation is mainly associated with uncertainty on the vugs permeability, distribution, and interconnectivity. The different results indicated by the Optimistic and Pessimistic Cases signify the importance of vugs permeability characterization. Therefore, injection test and pressure interference test among the wells could be considered to evaluate the local vugs permeability, extent, and interconnectivity. Porosity mapping derived from the seismic inversion could also be used in the succeeding task to characterize the lateral porosity distribution within the reservoir. With or without seismic inversion porosity mapping, it is worth exploring whether increased lateral heterogeneity plays a significant role in Potosi injectivity. Investigations on vugular, dolomitic outcrops suggest that there may be significantly greater lateral heterogeneity than what has been modeled here. Facies modeling within the Potosi has yet to be thoroughly addressed. The carbonates during the time of deposition are believed to be regionally extensive. However, it may be worth delineating the reservoir with other regional wells or modern day analogues to understand the extent of the Potosi. More specifically, the model could incorporate lateral changes or trends if deemed necessary to represent facies transition. Data acquisitions to characterize the fracture pressure gradient, the formation water properties, the relative permeability, and the capillary pressure could also be considered in order to allow a more rigorous evaluation of the Potosi storage performance. A simulation using several injectors could also be considered to determine the required number of wells to achieve the injection target while taking into account the pressure interference.

Adushita, Yasmin↗