Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooling system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

The power reliability event simulator tool (PRESTO): A novel approach to distribution system reliability analysis and applications

The growing interest in onsite solar photovoltaic and energy storage systems is partially motivated by customer concerns regarding grid reliability. However, accurately assessing the effectiveness of PVESS in mitigating these interruptions requires a comprehensive understanding of location-specific outage patterns and the ability to simulate realistic scenarios. To address the gap, we introduce the Power Reliability Event Simulation TOol (PRESTO), the first publicly available tool that simulates location-specific power interruptions at the county level. PRESTO allows for a more realistic assessment of system reliability by considering the unpredictability and location-specific patterns of power interruptions. We applied PRESTO in a case study of a single-family home across three U.S. counties, examining the performance of a solar photovoltaic system with 10kWh of battery storage during short-duration power interruptions. Our findings show that this system reliably met 93% of energy demand for essential non-heating and cooling loads, fully serving these loads in 84% of events, despite the constraints of daily time-of-use bill management which limits the battery's state-of-charge reserve. However, when heating and cooling loads were included, system performance decreased significantly, with only 70% of demand met and full service in 43% of events. These results highlight the challenges of using solar photovoltaic and energy storage systems for short-duration outages, emphasizing the need to consider factors like battery size and grid charging strategies to improve reliability. Our study demonstrates the practical applications of PRESTO, providing valuable insights into potential mitigation strategies including grid charging and optimizing battery size.

14 SOLAR ENERGY↗

Tests of a High Temperature Sample Conditioner for the Waste Treatment Plant LV-S2, LV S3, HV S3A and HV-S3B Exhaust Systems

Tests were performed to evaluate a sample conditioning unit for stack monitoring at Hanford Tank Waste Treatment and Immobilization Plant (WTP) exhaust stacks with elevated air temperatures. The LV-S2, LV-S3, HV-S3A and HV-S3B exhaust stacks are expected to have elevated air temperature and dew point. At these emission points, exhaust temperatures are too high to deliver the air sample directly to the required stack monitoring equipment. As a result, a sample conditioning system is considered to cool and dry the air prior to its delivery to the stack monitoring system. The method proposed for the sample conditioning is a dilution system that will introduce cooler, dry air to the air sample stream. This method of sample conditioning is meant to reduce the sample temperature while avoiding condensation of moisture in the sample stream. An additional constraint is that the ANSI/HPS N13.1-1999 standard states that at least 50% of the 10 µm aerodynamic diameter (AD) particles present in the stack free stream must be delivered to the sample collector. In other words, depositional loss of particles should be limited to 50% in the sampling, transport, and conditioning systems. Based on estimates of particle penetration through the LV-S3 sampling system, the diluter should perform with about 80% penetration or better to ensure that the total sampling system passes the 50% or greater penetration criterion.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experiments on a vapor compression air conditioner with liquid desiccants for efficient dehumidification

Buildings require air conditioning systems that not only cool and dehumidify supply air but also provide sufficient ventilation to ensure indoor air quality and occupant comfort. However, standard recirculation systems-which introduce about a 10 % to 20 % fraction of outdoor air-often fail to deliver air that is precisely cooled and dry, particularly because 80-90 % of the ventilation cooling load is latent. Mixing humid ventilation air with recirculated indoor air increases the energy and costs required to condition the air to comfortable levels. Dedicated outdoor air systems (DOASs) are designed to handle this latent dominated ventilation load and thus need to have efficient humidity removal. Many cooling cycles can perform this task. Here we describe a liquid desiccant DOAS, which combines a vapor compression cycle and a liquid desiccant absorber and desorber pair. We present its performance at 26 operating conditions and a thermodynamic model which can accurately predict the moisture removal efficiency. The model's performance predictions have a mean percentage error of 2.5 % and a coefficient of variation of the root mean square error of 7.5 %. We also compare the performance of this vapor-compression-coupled liquid desiccant system with a standard vapor compression system with the same components but no liquid desiccant. For the 26 conditions tested in this study, this comparison shows that adding liquid desiccants lowers the required evaporator cooling load by 21 %, allows for 25 % lower compressor volumetric capacity, and 25 % lower electricity use. Future work will leverage this model to quantify the reduction in annual electricity use across different climates, including the need for a standard vapor compression system to reheat the air during some of the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

In-situ heating-and-electron tomography for materials research: from 3D ( In-situ 2D) to 4D ( In-situ 3D)

In-situ observation has expanded the application of transmission electron microscopy (TEM) and has made a significant contribution to materials research and development for energy, biomedical, quantum, etc. Recent technological developments related to in-situ TEM have empowered the incorporation of three-dimensional observation, which was previously considered incompatible. In this review article, we take up heating as the most commonly used external stimulus for in-situ TEM observation and overview recent in-situ TEM studies. Then, we focus on the electron tomography (ET) and in-situ heating combined observation by introducing the authors’ recent research as an example. Assuming that in-situ heating observation is expanded from two dimensions to three dimensions using a conventional TEM apparatus and a commercially available in-situ heating specimen holder, the following in-situ heating-and-ET observation procedure is proposed: (i) use a rapid heating-and-cooling function of a micro-electro-mechanical system holder; (ii) heat and cool the specimen intermittently and (iii) acquire a tilt-series dataset when the specimen heating is stopped. This procedure is not too technically challenging and can have a wide range of applications. Essential technical points for a successful 4D (space and time) observation will be discussed through reviewing the authors’ example application.

36 MATERIALS SCIENCE↗

Influence of building heat distribution temperatures on the energy performance and sizing of 5th generation district heating and cooling networks

This paper investigates the energy performance and sizing criteria of 5th generation district heating and cooling (5GDHC) networks as a function of the heat distribution temperature in the building systems connected to the district network. An energy simulation model of a 5GDHC network was developed in Modelica for a case study located in Denmark. Calculations were carried out for four different building heating systems. Simulation results show that reducing the heat distribution temperatures from 70 °C to 23 °C leads to around 40% annual electric energy savings (from 10.4 kWh/m 2 to 6.2 kWh/m 2 ) for the operation of the heat pumps. Heat distribution temperatures of 23 °C cause higher water mass flow rates through the network, leading to annual electric energy consumption for the circulation pumps that are almost doubled (from 0.16 kWh/m 2 to 0.3 kWh/m 2 ) compared to the reference case at 70 °C. Furthermore, the paper discusses how the results obtained from the Danish case study can be generalized and applied to other cases using a simplified mathematical approach. In conclusion, it is found that about 1.5% of electric energy savings can be achieved for each temperature degree reduction in the heat distribution system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Project Phase 1 Report: Reducing Data Center Peak Cooling Demand and Energy Costs With Cold Underground Thermal Energy Storage (Cold UTES)

Cold Underground Thermal Energy Storage (Cold UTES) is an ultra-long duration grid energy storage technology. With Cold-UTES, low-cost grid power is converted to cold thermal energy and stored in the native subsurface rock at the point of use. Cold UTES is one approach within the general category of engineered geothermal systems. Cold UTES for peak-hour cooling of data centers (DCs) was studied for deployment in Maricopa County, Arizona and Loudoun County, Virgina using thermal storage capacities from 4 GWh-th to over 1,000 GWh-th (>1 Terawatt-hour). The two sites have different power and transmission systems, available grid energy resources, daily and seasonal load profiles, weather conditions, and grid regulatory requirements. The study results indicate high value for both locations and because of this, likely indicates value across most of the US and the world. The basis of the study was a 1,000 MW-e hourly electric use of DC computing and auxiliary loads, which was modeled as 1 GW-th of thermal load to a dry cooled heat rejection system - i.e. a cooling system that does not consume water. The electric power required for cooling the DC varies as the air temperature changes. In cold weather only the dry-coolers are used, with an electrical load for cooling load as low as 10 MW-e. In hot summer hours, chillers and dry- coolers are required, which raises the electrical load for cooling load to as much as 300 MW-e. The continuous and peak cooling electrical loads result in a grid interconnection requirement of no less than 1,300 MW-e. From both a grid and thermal design modeling perspective the 1.3 GW-e could either be a single facility or result from the total load at multiple sites.

15 GEOTHERMAL ENERGY↗

Machine Learning Analysis of Temperature-Strain Relationships for Structural Health Monitoring of Pipes: Self-powered wireless sensor system for health monitoring of liquid-sodium cooled fast reactors

This report presents machine learning (ML) analysis of temperature-strain relationships for structural health monitoring of nuclear reactor stainless steel (SS) pipes with the strain gauge sensor directly printed on the pipe with a 3D conformal aerosol jet printer. We investigate correlations for two sensor pairs installed on the same SS304 pipe: commercial K-type thermocouple with a printed gold strain gauge (TC3-SG3), and commercial K-type thermocouple with commercial Kyowa strain gauge (TC0-SG0). The temperature ranges for the sensor pairs TC0-SG0 and TC3-SG3 are 20.00°C to 266.37°C and 39.95°C to 219.28°C respectively. ML algorithms in this study include Linear Regression (baseline method), Ridge Regression, Lasso Regression, and Gradient Boosting. Performance evaluation metrics include Root Mean Square Error (RMSE), Mean Square Error (MSE), Mean Absolute Error (MAE), R 2 Score, and Explained Variance. Using advanced feature engineering techniques, we extracted 27 temperature-based features and 30 strategic inclusion features. The best performance was obtained with the Gradient Boosting method, which achieves prediction accuracy of R 2 = 0.9999 and RMSE = 7.69 μStrain for TC0-SG0, and R 2 = 0.9998 and RMSE = 18.03 μStrain for TC3-SG3. While the temperature-strain correlations are weaker for the gauge directly printed on the pipe than for the commercial strain gauge, deployment-ready performance exceeding industry standards is achieved for both sensor pairs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Balancing performance of active magnetic regenerators: a comprehensive experimental study of aspect ratio, particle size, and operating conditions

Abstract Effective and, at the same time, efficient active magnetic regenerator (AMR) performance requires balanced geometry and operating conditions. Here the influence of regenerator shape, magnetocaloric material size, operating frequency, and utilization on the performance of gadolinium packed-particle bed AMRs is demonstrated experimentally. Various metrics are applied to assess effectiveness and efficiency. Observed temperature spans and cooling powers across a wide range of operating conditions are used to evaluate system performance and estimate exergetic cooling power and exergetic power quotient. A new metric combining exergetic cooling power and pump power provides an estimate of the maximum achievable second law efficiency. Five regenerator geometries with equal volumes and the aspect ratio from 1.0 to 3.8, and four different ranges of Gd spherical particles between 182 and 354 µ m, are investigated. Improvements in system performance are demonstrated by a boost in specific cooling power of gadolinium from 0.85 to 1.16 W g −1 and maximum temperature span from 8.9 to 15.1 K. The optimum exergetic cooling power is observed for 1.37 utilization and 3 Hz operating frequency, exergetic power quotient exhibits a maximum at the same utilization but at 2 Hz frequency, while the highest efficiency is recorded at 1 Hz and utilization of 0.5, demonstrating that multiple performance metrics must be balanced to achieve regenerator design meeting all performance targets.

42 ENGINEERING↗

Light storage, retrieval, and controllable interference in an atomic tripod system

Highly efficient quantum memories are essential for advancing quantum information processing technologies, including scalable quantum computing and quantum networks. We experimentally demonstrate a light storage and retrieval protocol in a tripod system using an ensemble of laser-cooled 87 Rb atoms. The tripod system, which consists of three ground states and an excited state, offers rich dynamics: its use to coherently store and retrieve a weak probe pulse in the 87 Rb 𝐹 = 1 ground-state manifold leads to the interference of two spin-wave excitations during storage time that translate to an interference in the peak intensity of the retrieved probe pulse. Our work shows that these interferences, which manifest when varying the pulse sequence or energy level structure, can be controlled experimentally by varying the storage time, optical phase, and magnetic field strength. Theoretical simulations exhibit excellent agreement with the experimental results. In conclusion, this work demonstrates the rich dynamics and versatile capabilities of atomic tripod systems for light storage and retrieval, with key advantages over conventional Λ systems, highlighting the potential of atomic tripod systems for applications in quantum information processing, quantum synchronization, and atomic memory protocols.

Coherent control↗

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it's desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilation systems (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. While this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and - of greatest concern - outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger HVAC systems. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Mitsubishi Electric Trane US, CORE Energy Recovery Solutions, and Therma-Stor LLC to design and test VICS prototypes. A conceptual diagram is shown in Figure 1, and the latest prototype (shown in Figure 2) was manufactured by Therma-Stor and tested in SWA's facility in Norwalk, CT. The ERV heat exchanger was provided by CORE, and the VICS was installed in conjunction with a 1-ton, inverter heat pump provided by Mitsubishi.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Simulation and Experimental Validation of an Integrated Heat Pump – Thermal Energy Storage Using a Room-Temperature Phase Change Material

As the dependence on electrical heat pumps (HPs) and intermittent renewables increases, grid strains are expected to grow. This necessitates an energy storage system to reduce the mismatch between energy supply and demand. Thus, a proposed dual-mode commercially available 14.1 kW HP was integrated with a single 22°C phase change material (PCM) thermal storage system (TES) to load-shift both cooling and heating loads. The HP-TES system was manufactured and experimentally tested using a novel test matrix based on AHRI 210/240 psychrometric conditions. Furthermore, transient dual-mode system-level HP-TES models were developed in Modelica and validated using the experimental test conditions. Base HP cooling and heating experimental tests at ambient temperatures of 35°C and −8.3°C show that the modified HP-TES maintained the rated system capacity and performance. The HP-TES discharge provided approximately 30% and 50% reductions in cooling and heating demand, respectively. The transient HP-TES models predicted system capacity and total power input for discharge and recharge operating modes within ±4% mean percentage error, and recharge power input within ±2%, with maximum errors occurring at the equipment startup. During system operation, the sources of model deviations are first-order polynomial fits of the PCM digital scanning calorimetry (DSC) data and unaccounted supercooling in the PCM during solidification. Nonetheless, the model predictions agree with the experimental tests, demonstrating the availability of robust, accurate, and validated transient models that can be used for further validation and the development of system controls.

25 ENERGY STORAGE↗

Biologically Cooling the Planet: A BRISK Approach that Directly Connects the Ground to Deep Space

Climate change is a grave threat to our ability to thrive and prosper on Earth. Accumulation of greenhouse gases in the atmosphere stifle the Earth’s ability to cool itself, which leads to a rise of the average temperature – Global warming. The planetary cooling is exclusively radiative – thermal radiation escapes into cold outer space via a flux of photons at the low-infrared range. The penetration of these photons through Earth’s atmosphere is dictated by atmospheric transparency, which, serendipitously possesses a window centered around the peak of the Plank spectrum for a black body at about room temperature – the average temperature of Earth. This window spanning about 8 --13 μm wavelengths allows most of the photons in this range to escape into the Cosmos carrying our planet’s heat away. The efficiency of this outer heat flux – and thus planet’s cooling ability – can be controlled via emissivity – a function of wavelength which multiplies the fundamental Plank spectrum of a black body at a given temperature. In the presence of non-trivial atmospheric transparency it can be shown that radiative cooling can be enhanced with properly “designed” emissivity function. For the last 100 years, or so, people have been looking into ways to engineer materials to take advantage of such enhancement for various cooling applications, from making ice to cool clothes, and substantial progress has been achieved, including cooling in direct sunlight. The beauty if this approach is that it is entirely passive – no energy input is required. The objective of this project was to investigate whether biological systems possess such advanced cooling capacity, developed via millennia of evolution, to enhance plant’s adaptation to a hot environment, to increase cooling capability, and possibly modulate spectral emissivities on short or long time scales. We wanted to know if BRISK (Biological Radiative Sky Cooling) occurs and to what extent. It is unknown whether biological systems can perform this "spectral redistribution." It is reasonable to expect, however, that they might: in particular, desert plants under high heat stress and arid conditions might evolve this mechanism in order to maintain a tolerable internal temperature. Our intended approach was twofold: extensive literature search and supporting experimental investigations on select plants. We obtained the answers from the former, while the latter proved to be more complicated to perform with required accuracy in the timespan/budget of a small seedling project. After one year of research, we concluded that among the plant species studied there seem to be no evidence of BRISK, but it’s not the end of the story. Our planet’s biosphere is immense, and the evolution is continuing. With our preliminary results and a better understanding of what to look for further discoveries await, considering the accelerated pace of infrared imaging and spectroscopy technology development, from microscopic to satellite-based studies of plants and canopies. In the end, Earth’s energy balance is ultimately tied to radiative cooling so that further investigation into this problem is directly tied to solving the Climate Change challenge.

54 ENVIRONMENTAL SCIENCES↗

Progress in Fast Modular Reactor Conceptual Design

The Fast Modular Reactor (FMR) is a 100-MW(thermal) gas-cooled fast reactor being developed by General Atomics Electromagnetic System with the goal of developing a FMR for flexible and dispatchable power to the U.S. electricity market in the mid-2030s. The conceptual design aims to develop and verify simplified design features. These include an inert helium gas coolant, pellet-loaded fuel rods, installations with air cooling as ultimate heat sink, and small and passive heat removal systems. The goal is to ensure the development of a safe, maintainable, cost-effective, and distributed nuclear energy-generating station. The baseline technologies selected to achieve this goal are a helium coolant that is an inert gas with no chemical reaction with structural components, not activated, single phase, enabling high-temperature operation and a high thermal efficiency Brayton cycle; conventional uranium dioxide (UO 2 ) fuel, which is the most widely used and well-known fuel material, capable of high burnup (100 MWd/kg) and a long fuel life; and silicon carbide composite (SiGA®) cladding and internal structures that are chemically inert in the helium environment, exceptionally radiation tolerant, and being derisked by accident tolerant fuel technology development. Further, the reactor was specifically designed with passive safety features, including high-temperature in-core materials and a reactor vessel cooling system consisting of cooling panels of naturally circulating water. The passive safety of the core was confirmed for the depressurized loss-of–forced cooling accident, which showed the peak cladding temperature at ~1600°C during the transient, which is below the current design limit of 1800°C. The conceptual design of the FMR has been conducted for the reactor system, vessel system, generator and turbomachine, instrumentation and control, residual heat removal system, plant service system, and containment, as well as pre-application licensing documents.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Final Cooling with Thick Wedges for a Muon Collider

A muon collider is a particle accelerator that collides muons rather than protons or electrons. An important component of such a collider is cooling, in which the emittance of the muon beam is reduced to make it suitable for use in a collider. In the last stage of this process, called final 4D cooling, emittance in the transverse axes is reduced while emittance in the longitudinal axis is allowed to grow. In previous studies, Final 4-D cooling used absorbers within very high field solenoids to cool low-momentum muons. Simulations of the systems did not reach the desired cooling design goals. In this study, we develop and optimize a different conceptual design for the final 4D cooling channel, which is based on single thick wedges. We used G4Beamline to simulate the channel and Python to generate and analyze particle distributions. We characterized the effects of various parameters on the performance of this system, including the initial emittances and Twiss parameters, the length and angle of the wedges, the length of the drift channel, and the length, frequency, gradient, and phase of the RF cavities. We optimized the design parameters of the cooling channel and produced two conceptual designs (corresponding to two possible starting points for the input beam) which achieve transverse cooling in both x and y by a factor of ≈ 3.5. These channels achieve a lower transverse and longitudinal emittance than the best design previously published.

43 PARTICLE ACCELERATORS↗

Modeling a Water-Cooled Printed Circuit Heat Exchanger Condensing CO2 for use in SCO2 Cycle System Optimization Studies

This work describes a one-dimensional model of a water-cooled printed circuit heat exchanger (PCHE) condensing supercritical CO2. The model is developed for use in cycle optimization studies (e.g., minimizing levelized cost of electricity) as either the main heat rejection cooler and/or a compressor intercooler for recompression closed Brayton supercritical CO2 power cycles. Sensitivity and case studies are used to illustrate the impact of important model parameters, and this includes allowing for independent variation of zig-zag channel wave angles on the CO2 and water side. Results show that for a given CO2 design pressure (and thus saturation temperature), the PCHE design inlet water temperature has a significant impact on the PCHE size. Results also demonstrate that if wave angles are the same on the CO2 and water side, the water side pressure drop will have more influence on determining the optimum PCHE mass than the CO2 side pressure drop. Reducing the water side wave angle to near straight channel flow offers a more compact design for a similar water side pressure drop (and pump power requirement). Cases are also shown for further increasing the compactness and how the PCHE mass is affected along with water pump power.

Liese, Eric↗

Multiscale Thermal-hydraulic analysis of the MARVEL microreactor using a coupled SAM and SCM simulation. (PPTX)

This is .pptx document presenting a summary of the paper of the same name that has been submitted and accepted to NURETH-21: MARVEL is a natural-convection-cooled sodium-potassium microreactor that is anticipated to generate 85 kilowatts of thermal energy. It will operate within Idaho National Laboratory Transient Reactor Test Facility and is being developed by the DOE Microreactor Program. MARVEL will be used to test microreactor applications, evaluate systems for remote monitoring, and develop autonomous control technologies. A thermal-hydraulic computational model of this facility is a valuable tool to study important transients and calculate the safety limits of the micro-reactor design. For this purpose, the authors have chosen to use a multiscale coupled simulation: SCM for modeling the reactor core and SAM for the reactor's primary cooling system. SCM is MOOSE physics module for subchannel analysis, which was designed to model single-phase flows through liquid-metal cooled, wire-wrapped fuel pin sub-assemblies, ordered in a triangular lattice. The SCM code was modified to be able to model MARVEL?s unique geometry. SAM is a systems analysis module based on the MOOSE framework. It aims to provide fast-running, whole-plant transient analyses capability with improved-fidelity for various advanced reactor types. The coupling between the two SCM and SAM for MARVEL modeling is done implementing a domain over-lapping approach. The resulting coupled simulation can model transients such as reactor startup/shutdown and provide an intermediate fidelity picture of the temperature field and other variables, in the core. Results for the steady-state simulations are presented in the article as well as flow blockage transient.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗