Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “conclusion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

What Can Meta-Analyses Tell Us About the Reliability of Life Cycle Assessment for Decision Support?

The body of life cycle assessment (LCA) literature is vast and has grown over the last decade at a dauntingly rapid rate. Many LCAs have been published on the same or very similar technologies or products, in some cases leading to hundreds of publications. One result is the impression among decision makers that LCAs are inconclusive, owing to perceived and real variability in published estimates of life cycle impacts. Despite the extensive available literature and policy need formore conclusive assessments, only modest attempts have been made to synthesize previous research. A significant challenge to doing so are differences in characteristics of the considered technologies and inconsistencies in methodological choices (e.g., system boundaries, coproduct allocation, and impact assessment methods) among the studies that hamper easy comparisons and related decision support. An emerging trend is meta-analysis of a set of results from LCAs, which has the potential to clarify the impacts of a particular technology, process, product, or material and produce more robust and policy-relevant results. Meta-analysis in this context is defined here as an analysis of a set of published LCA results to estimate a single or multiple impacts for a single technology or a technology category, either in a statistical sense (e.g., following the practice in the biomedical sciences) or by quantitative adjustment of the underlying studies to make them more methodologically consistent. One example of the latter approach was published in Science by Farrell and colleagues (2006) clarifying the net energy and greenhouse gas (GHG) emissions of ethanol, in which adjustments included the addition of coproduct credit, the addition and subtraction of processes within the system boundary, and a reconciliation of differences in the definition of net energy metrics. Such adjustments therefore provide an even playing field on which all studies can be considered and at the same time specify the conditions of the playing field itself. Understanding the conditions under which a meta-analysis was conducted is important for proper interpretation of both the magnitude and variability in results. This special supplemental issue of the Journal of Industrial Ecology includes 12 high-quality metaanalyses and critical reviews of LCAs that advance understanding of the life cycle environmental impacts of different technologies, processes, products, and materials. Also published are three contributions on methodology and related discussions of the role of meta-analysis in LCA. The goal of this special supplemental issue is to contribute to the state of the science in LCA beyond the core practice of producing independent studies on specific products or technologies by highlighting the ability of meta-analysis of LCAs to advance understanding in areas of extensive existing literature. The inspiration for the issue came from a series of meta-analyses of life cycle GHG emissions from electricity generation technologies based on research from the LCA Harmonization Project of the National Renewable Energy Laboratory (NREL), a laboratory of the U.S. Department of Energy, which also provided financial support for this special supplemental issue. (See the editorial from this special supplemental issue [Lifset 2012], which introduces this supplemental issue and discusses the origins, funding, peer review, and other aspects.) The first article on reporting considerations for meta-analyses/critical reviews for LCA is from Heath and Mann (2012), who describe the methods used and experience gained in NREL's LCA Harmonization Project, which produced six of the studies in this special supplemental issue. Their harmonization approach adapts key features of systematic review to identify and screen published LCAs followed by a meta-analytical procedure to adjust published estimates to ones based on a consistent set of methods and assumptions to allow interstudy comparisons and conclusions to be made. In a second study on methods, Zumsteg and colleagues (2012) propose a checklist for a standardized technique to assist in conducting and reporting systematic reviews of LCAs, including meta-analysis, that is based on a framework used in evidence-based medicine. Widespread use of such a checklist would facilitate planning successful reviews, improve the ability to identify systematic reviews in literature searches, ease the ability to update content in future reviews, and allow more transparency of methods to ease peer review and more appropriately generalize findings. Finally, Zamagni and colleagues (2012) propose an approach, inspired by a meta-analysis, for categorizing main methodological topics, reconciling diverging methodological developments, and identifying future research directions in LCA. Their procedure involves the carrying out of a literature review on articles selected according to predefined criteria.

54 ENVIRONMENTAL SCIENCES↗

Band or Polaron: The Hole Conduction Mechanism in the p-Type Spinel Rh 2ZnO4

Given the emerging role of oxide spinels as hole conductors, we discuss in this article the traditional vs. new methodologies of determining the type of conduction mechanism at play - localized polaronic vs. band-like transport. Applying (i) traditional small polaron analysis to our in-situ high temperature four-point conductivity and thermopower measurements, we previously found an activated mobility, which is indicative of the small polaron mechanism. However, (ii) employing the recent developments in correcting density functional methodologies for hole localization, we predict that the self-trapped hole is unstable and that Rh{sub 2}ZnO{sub 4} is instead a band conductor with a large effective mass. The hole mobility measured by high-field room temperature Hall effect also suggests band rather than polaron conduction. The apparent contradiction between the conclusion of the traditional procedure (i) and first-principles theory (ii) is resolved by taking into account in the previous transport analysis the temperature dependence of the effective density of states, which leads to the result that the mobility is actually temperature-independent in Rh{sub 2}ZnO{sub 4}. Our case study on Rh{sub 2}ZnO{sub 4} illustrates the range of experimental and theoretical approaches at hand to determine whether the transport mechanism of a semiconductor is band or small polaron conduction.

14 SOLAR ENERGY↗

Expression of Acetate Permease-like (apl) Genes in Subsurface Communities of Geobacter Species Under Fluctuating Acetate Concentrations

The addition of acetate to uranium-contaminated aquifers in order to stimulate the growth and activity of Geobacter species that reduce uranium is a promising in situ bioremediation option. Optimizing this bioremediation strategy requires that sufficient acetate be added to promote Geobacter species growth. We hypothesized that under acetate-limiting conditions, subsurface Geobacter species would increase the expression of either putative acetate symporters genes (aplI and aplII). Acetate was added to a uranium-contaminated aquifer (Rifle, CO) in two continuous amendments separated by 5 days of groundwater flush to create changing acetate concentrations. While the expression of aplI in monitoring well D04 (high acetate) weakly correlated with the acetate concentration over time, the transcript levels for this gene were relatively constant in well D08 (low acetate). At the lowest acetate concentrations during the groundwater flush, the transcript levels of aplII were the highest. The expression of aplII decreased 2–10-fold upon acetate reintroduction. However, the overall instability of acetate concentrations throughout the experiment could not support a robust conclusion regarding the role of apl genes in response to acetate limitation under field conditions, in contrast to previous chemostat studies, suggesting that the function of a microbial community cannot be inferred based on lab experiments alone.

acetate↗

Effectiveness of fat grafting in scar reduction: A systematic review and meta‐analysis

Abstract Background Scar brings great physical and mental pain to patients. Fat grafting may be a new and simple way to treat scar. This review aimed to systematically evaluate the correlation between fat grafting and scar reduction. Methods The author searched Chinese and English literature databases such as CNKI, Wanfang Data, Cqvip, Pubmed, Web of Science, Embase, CBM, etc. for articles published in the period from 2011 to 2021 about the randomized controlled trials (RCTs) to assess the effect of fat grating on scar reduction, and then performed meta‐analysis with Review Manager 5.4. Results A total of nine articles were included in the assessment of the effect of fat grafting on scar reduction, with meta‐analysis suggesting statistical significance (OR = 5.63, 95% CI: 3.01–10.53, p < 0.01). There was statistical significance in the difference observed between the simple fat grating group ( p = 0.004) and the group of existing therapies combined with fat grafting ( p < 0.0001). Conclusion Fat grafting may be a good method for scar treatment, especially when it's combined with other therapies. Still, due to the limitations of included RCTs, more large‐scale high‐quality RCTs must be carried out before solid conclusions can be drawn.

Zhang, Xiaoyuan↗

Spatial Replication Is Important for Developing Landscape Genetic Inferences for a Wetland Salamander

Habitat fragmentation is a pressing threat to wildlife populations, and maintenance of gene flow between populations is an essential goal of conservation. Resistance surfaces have emerged as an important tool for modelling connectivity and developing management strategies to mitigate effects of habitat fragmentation. However, recent studies have noted inconsistencies in the factors most strongly associated with connectivity across different landscapes. Thus, replication of genetic-based resistance surface optimisation across landscapes may be necessary for making robust conclusions about the influence of environmental variables. Accordingly, replication represents a substantive challenge and opportunity in the field of landscape genetics. In this study, we conducted replicated landscape genetic analyses across five landscapes in Tennessee and Kentucky for a threatened wetland amphibian, the four-toed salamander (Hemidactylium scutatum). We tested multiple hypotheses of how different landscape features that could directly affect small, desiccation-intolerant amphibians (e.g., canopy cover) influenced gene flow and assessed the appropriate scale at which to model different features. We found some concordance in the landscape features that influenced gene flow (e.g., a common importance of forest cover and topography), but also some differences—potentially owing to the difference in variability of predictors across landscapes. We also found discordance in the scale of effect of different features across landscapes. In conclusion, our work emphasises that flat areas of moist forest not bisected by roads may be important for H. scutatum conservation, and our replicated design allows us to identify relationships that would have been missed if only using one study site.

59 BASIC BIOLOGICAL SCIENCES↗

High-throughput sequencing of the chloroplast and mitochondrion of Chlamydomonas reinhardtii to generate improved de novo assemblies, analyze expression patterns and transcript speciation, and evaluate diversity among laboratory strains and wild isolates

Chlamydomonas reinhardtii is a unicellular chlorophyte alga that is widely studied as a reference organism for understanding photosynthesis, sensory and motile cilia, and for development of an algal-based platform for producing biofuels and bio-products. Its highly repetitive, ~205-kbp circular chloroplast genome and ~15.8-kbp linear mitochondrial genome were sequenced prior to the advent of high-throughput sequencing technologies. Here, high coverage shotgun sequencing was used to assemble both organellar genomes de novo. These new genomes correct dozens of errors in the prior genome sequences and annotations. Gen-ome sequencing coverage indicates that each cell contains on average 83 copies of the chloroplast genome and 130 copies of the mitochondrial genome. Using protocols and analyses optimized for organellar tran-scripts, RNA-Seq was used to quantify their relative abundances across 12 different growth conditions. Forty-six percent of total cellular mRNA is attributable to high expression from a few dozen chloroplast genes. RNA-Seq data were used to guide gene annotation, to demonstrate polycistronic gene expression, and to quantify splicing of psaA and psbA introns. In contrast to a conclusion from a recent study, we found that chloroplast transcripts are not edited. Unexpectedly, cytosine-rich polynucleotide tails were observed at the 3’-end of all mitochondrial transcripts. A comparative genomics analysis of eight laboratory strains and 11 wild isolates of C. reinhardtii identified 2658 variants in the organellargenomes, which is 1/10th as much genetic diversity as is found in the nucleus.

ftsH↗

PREDICTION OF CYCLIC VARIABILITY AND KNOCK-LIMITED SPARK ADVANCE (KLSA) IN SPARK-IGNITION (SI) ENGINE

Engine knock remains one of the major barriers to further improve the thermal efficiency of spark-ignition (SI) engines. SI engine is usually operated at knock-limited spark advance (KLSA) to achieve possibly maximum efficiency with given engine hardware and fuel properties. Co-optimization of fuels and engines is promising to improve engine efficiency, and predictive computational fluid dynamics (CFD) models can be used to facilitate this process. However, cyclic variability of SI engine demands that multi cycle results are required to capture the extreme conditions. In addition, Mach Courant Friedrichs-Lewy (CFL) number of 1 is desired to accurately predict the knock intensity (KI), resulting in unaffordable computational cost. In this study, a new approach to numerically predict KLSA using large Mach CFL of 50 with ten consecutive cycle simulation is proposed. This approach is validated against the experimental data for a boosted SI engine at multiple loads and spark timings with good agreements in terms of cylinder pressure, combustion phasing, and cyclic variation. Engine knock is predicted with early spark timing, indicated by significant pressure oscillation and end-gas heat release. Maximum amplitude of pressure oscillation analysis is performed to quantify the KI, and the slope change point in KI extrema is used to indicate the KLSA accurately. Using a smaller Mach CFL number of 5 also results in the same conclusions, thus demonstrating that this approach is insensitive to the Mach CFL number. The use of large Mach CFL number allows us to achieve fast turn-around time for multicycle engine CFD simulations.

CCV↗

Validation Assessment of Turbulent Reacting Flow Model Using The Area-Validation Metric on Medium-Scale Methanol Pool Fire Results

Accident analysis and ensuring power plant safety are pivotal in the nuclear energy sector. Significant strides have been achieved over the past few decades regarding fire protection and safety, primarily centered on design and regulatory compliance. Yet, after the Fukushima accident a decade ago, the imperative to enhance measures against fire, internal flooding, and power loss has intensified. Hence, a comprehensive, multilayered protection strategy against severe accidents is needed. Consequently, gaining a deeper insight into pool fires and their behavior through extensive validated data can greatly aid in improving these measures using advanced validation techniques. A model validation study was performed at Sandia National Laboratories in which a 30-cm diameter methanol pool fire was modeled using the SIERRA/Fuego turbulent reacting flow code. This validation study used a standard validation experiment to compare model results against, and conclusions have been published. The fire was modeled with a Large Eddy Simulation (LES) turbulence model with subgrid turbulent kinetic energy closure. Combustion was modeled using a strained laminar flamelet library approach. Radiative heat transfer was accounted for with a model utilizing the gray-gas approximation. In the present study, additional validation analysis is performed using the area validation metric (AVM). These activities are done on multiple datasets involving different variables and temporal/spatial ranges and intervals. In conclusion, the results provide insight into the use of the area validation metric on such temporally varying datasets and the importance of physics-aware use of the metric for proper analysis.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Evaluation of high-energy brachytherapy source electronic disequilibrium and dose from emitted electrons

Purpose: The region of electronic disequilibrium near photon-emitting brachytherapy sources of high-energy radionuclides ({sup 60}Co, {sup 137}Cs, {sup 192}Ir, and {sup 169}Yb) and contributions to total dose from emitted electrons were studied using the GEANT4 and PENELOPE Monte Carlo codes. Methods: Hypothetical sources with active and capsule materials mimicking those of actual sources but with spherical shape were examined. Dose contributions due to source photons, x rays, and bremsstrahlung; source {beta}{sup -}, Auger electrons, and internal conversion electrons; and water collisional kerma were scored. To determine if conclusions obtained for electronic equilibrium conditions and electron dose contribution to total dose for the representative spherical sources could be applied to actual sources, the {sup 192}Ir mHDR-v2 source model (Nucletron B.V., Veenendaal, The Netherlands) was simulated for comparison to spherical source results and to published data. Results: Electronic equilibrium within 1% is reached for {sup 60}Co, {sup 137}Cs, {sup 192}Ir, and {sup 169}Yb at distances greater than 7, 3.5, 2, and 1 mm from the source center, respectively, in agreement with other published studies. At 1 mm from the source center, the electron contributions to total dose are 1.9% and 9.4% for {sup 60}Co and {sup 192}Ir, respectively. Electron emissions become important (i.e., >0.5%) within 3.3 mm of {sup 60}Co and 1.7 mm of {sup 192}Ir sources, yet are negligible over all distances for {sup 137}Cs and {sup 169}Yb. Electronic equilibrium conditions along the transversal source axis for the mHDR-v2 source are comparable to those of the spherical sources while electron dose to total dose contribution are quite different. Conclusions: Electronic equilibrium conditions obtained for spherical sources could be generalized to actual sources while electron contribution to total dose depends strongly on source dimensions, material composition, and electron spectra.

61 RADIATION PROTECTION AND DOSIMETRY↗

Ionization chamber gradient effects in nonstandard beam configurations

Purpose: For the purpose of nonstandard beam reference dosimetry, the current concept of reporting absorbed dose at a point in water located at a representative position in the chamber volume is investigated in detail. As new nonstandard beam reference dosimetry protocols are under development, an evaluation of the role played by the definition of point of measurement could lead to conceptual improvements prior to establishing measurement procedures. Methods: The present study uses the current definition of reporting absorbed dose to calculate ionization chamber perturbation factors for two cylindrical chamber models (Exradin A12 and A14) using the Monte Carlo method. The EGSnrc based user-code EGS lowbar chamber is used to calculate chamber dose responses of 14 IMRT beams chosen to cause considerable dose gradients over the chamber volume as previously used by Bouchard and Seuntjens [''Ionization chamber-based reference dosimetry of intensity modulated radiation beams,'' Med. Phys. 31(9), 2454-5465 (2004)]. Results: The study shows conclusively the relative importance of each physical effect involved in the nonstandard beam correction factors of 14 IMRT beams. Of all correction factors involved in the dosimetry of the beams studied, the gradient perturbation correction factor has the highest magnitude, on average, 11% higher compared to reference conditions for the Exradin A12 chamber and about 5% higher for the Extradin A14 chamber. Other perturbation correction factors (i.e., P{sub wall}, P{sub stem}, and P{sub cel}) are, on average, less than 0.8% different from reference conditions for the chambers and beams studied. The current approach of reporting measured absorbed dose at a point in water coinciding with the location of the centroid of the chamber is the main factor responsible for large correction factors in nonstandard beam deliveries (e.g., intensity modulated radiation therapy) reported in literature. Conclusions: To reduce or eliminate the magnitude of perturbation correction factors in nonstandard beam reference dosimetry, two possible ways to report absorbed dose are suggested: (1) Reporting average dose to the sensitive volume of the chamber filled with water, combined with removing the reference field implicit gradient effect when measuring output factors, and (2) reporting average dose to the chamber itself during output factor verifications. The first option could be adopted if clinical beam correction factors are negligible. The second option could simplify quality assurance procedures when correction factors are not negligible and have to be calculated using Monte Carlo simulations.

61 RADIATION PROTECTION AND DOSIMETRY↗

X-ray energy optimization in minibeam radiation therapy

Purpose: The purpose of this work is to assess which energy in minibeam radiation therapy provides the best compromise between the deposited dose in the tumor and the sparing of the healthy tissues. Methods: Monte Carlo simulations (PENELOPE 2006) have been used as a method to calculate the ratio of the peak-to-valley doses (PVDR) in the healthy tissues and in the tumor for different beam energies. The maximization of the ratio of PVDR in the healthy tissues and in the tumor has been used as a criterion. Results: The main result of this work is that, for the parameters being used in preclinical trials (minibeam sizes of 600 {mu}m and 1200 {mu}m center-to-center separation), the optimum beam energy is 375 keV. Conclusions: The conclusion is that this is the energy of minibeams that should be used in the preclinical studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient geometry-driven information retrieval for IMRT treatment plan quality control

Purpose: Intensity modulated radiation therapy (IMRT) treatment plan quality depends on the planner's level of experience and the amount of time the planner invests in developing the plan. Planners often unwittingly accept plans when further sparing of the organs at risk (OARs) is possible. The authors propose a method of IMRT treatment plan quality control that helps planners to evaluate the doses of the OARs upon completion of a new plan. Methods: It is achieved by comparing the geometric configurations of the OARs and targets of a new patient with those of prior patients, whose plans are maintained in a database. They introduce the concept of a shape relationship descriptor and, specifically, the overlap volume histogram (OVH) to describe the spatial configuration of an OAR with respect to a target. The OVH provides a way to infer the likely DVHs of the OARs by comparing the relative spatial configurations between patients. A database of prior patients is built to serve as an external reference. At the conclusion of a new plan, planners search through the database and identify related patients by comparing the OAR-target geometric relationships of the new patient with those of prior patients. The treatment plans of these related patients are retrieved from the database and guide planners in determining whether lower doses delivered to the OARs in the new plan are feasible. Results: Preliminary evaluation is promising. In this evaluation, they applied the analysis to the parotid DVHs of 32 prior head-and-neck patients, whose plans are maintained in a database. Each parotid was queried against the other 63 parotids to determine whether a lower dose was possible. The 17 parotids that promised the greatest reduction in D{sub 50} (DVH dose at 50% volume) were flagged. These 17 parotids came from 13 patients. The method also indicated that the doses of the other nine parotids of the 13 patients could not be reduced, so they were included in the replanning process as controls. Replanning with an effort to reduce D{sub 50} was conducted on these 26 parotids. After replanning, the average reductions for D{sub 50} of the 17 flagged parotids and nine unflagged parotids were 6.6 and 1.9 Gy, respectively. These results demonstrate that the quality control method has accurately identified not only the parotids that require dose reductions but also those for which dose reductions are marginal. Originally, 11 of out the 17 flagged parotids did not meet the Radiation Therapy Oncology Group sparing goal of V(30 Gy)<50%. Replanning reduced them to three. Additionally, PTV coverage and OAR sparing of the original plans were compared to those of the replans by using pairwise Wilcoxon p test. The statistical comparisons show that replanning compromised neither PTV coverage nor OAR sparing. Conclusions: This method provides an effective quality control mechanism for evaluating the DVHs of the OARs. Adoption of such a method will advance the quality of current IMRT planning, providing better treatment plan consistency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Theoretical and empirical investigations of KCl:Eu{sup 2+} for nearly water-equivalent radiotherapy dosimetry

Purpose: The low effective atomic number, reusability, and other computed radiography-related advantages make europium doped potassium chloride (KCl:Eu{sup 2+}) a promising dosimetry material. The purpose of this study is to model KCl:Eu{sup 2+} point dosimeters with a Monte Carlo (MC) method and, using this model, to investigate the dose responses of two-dimensional (2D) KCl:Eu{sup 2+} storage phosphor films (SPFs). Methods: KCl:Eu{sup 2+} point dosimeters were irradiated using a 6 MV beam at four depths (5-20 cm) for each of five square field sizes (5x5-25x25 cm{sup 2}). The dose measured by KCl:Eu{sup 2+} was compared to that measured by an ionization chamber to obtain the magnitude of energy dependent dose measurement artifact. The measurements were simulated using DOSXYZnrc with phase space files generated by BEAMnrcMP. Simulations were also performed for KCl:Eu{sup 2+} films with thicknesses ranging from 1 {mu}m to 1 mm. The work function of the prototype KCl:Eu{sup 2+} material was determined by comparing the sensitivity of a 150 {mu}m thick KCl:Eu{sup 2+} film to a commercial BaFBr{sub 0.85}I{sub 0.15}:Eu{sup 2+}-based SPF with a known work function. The work function was then used to estimate the sensitivity of a 1 {mu}m thick KCl:Eu{sup 2+} film. Results: The simulated dose responses of prototype KCl:Eu{sup 2+} point dosimeters agree well with measurement data acquired by irradiating the dosimeters in the 6 MV beam with varying field size and depth. Furthermore, simulations with films demonstrate that an ultrathin KCl:Eu{sup 2+} film with thickness of the order of 1 {mu}m would have nearly water-equivalent dose response. The simulation results can be understood using classic cavity theories. Finally, preliminary experiments and theoretical calculations show that ultrathin KCl:Eu{sup 2+} film could provide excellent signal in a 1 cGy dose-to-water irradiation. Conclusions: In conclusion, the authors demonstrate that KCl:Eu{sup 2+}-based dosimeters can be accurately modeled by a MC method and that 2D KCl:Eu{sup 2+} films of the order of 1 {mu}m thick would have minimal energy dependence. The data support the future research and development of a KCl:Eu{sup 2+} storage phosphor-based system for quantitative, high-resolution multidimensional radiation therapy dosimetry.

36 MATERIALS SCIENCE↗

Smoothing of respiratory motion traces for motion-compensated radiotherapy

Purpose: The CyberKnife system has been used successfully for several years to radiosurgically treat tumors without the need for stereotactic fixation or sedation of the patient. It has been shown that tumor motion in the lung, liver, and pancreas can be tracked with acceptable accuracy and repeatability. However, highly precise targeting for tumors in the lower abdomen, especially for tumors which exhibit strong motion, remains problematic. Reasons for this are manifold, like the slow tracking system operating at 26.5 Hz, and using the signal from the tracking camera ''as is''. Since the motion recorded with the camera is used to compensate for system latency by prediction and the predicted signal is subsequently used to infer the tumor position from a correlation model based on x-ray imaging of gold fiducials around the tumor, camera noise directly influences the targeting accuracy. The goal of this work is to establish the suitability of a new smoothing method for respiratory motion traces used in motion-compensated radiotherapy. The authors endeavor to show that better prediction--With a lower rms error of the predicted signal--and/or smoother prediction is possible using this method. Methods: The authors evaluated six commercially available tracking systems (NDI Aurora, PolarisClassic, Polaris Vicra, MicronTracker2 H40, FP5000, and accuTrack compact). The authors first tracked markers both stationary and while in motion to establish the systems' noise characteristics. Then the authors applied a smoothing method based on the a trous wavelet decomposition to reduce the devices' noise level. Additionally, the smoothed signal of the moving target and a motion trace from actual human respiratory motion were subjected to prediction using the MULIN and the nLMS{sub 2} algorithms. Results: The authors established that the noise distribution for a static target is Gaussian and that when the probe is moved such as to mimic human respiration, it remains Gaussian with the exception of the FP5000 and the Aurora systems. The authors also showed that the proposed smoothing method can indeed be used to filter noise. The signal's jitter dropped by as much as 95% depending on the tracking system employed. Subsequently, the 3D prediction error (rms) for a prediction horizon of 150 ms on a synthetic signal dropped by up to 37% when using a normalized LMS prediction algorithm (nLMS{sub 2}) and hardly changed when using a MULIN algorithm. When smoothing a real signal obtained in our laboratory, the improvement of prediction was similar: Up to 30% for both the nLMS{sub 2} and the best MULIN algorithm. The authors also found a noticeable increase in smoothness of the predicted signal, the relative jitter dropped by up to 95% on the real signal, and on the simulated signal. Conclusions: In conclusion, the authors can say that preprocessing of marker data is very useful in motion-compensated radiotherapy since the quality of prediction increases. This will result in better performance of the correlation model. As a side effect, since the prediction of a preprocessed signal is also less noisy, the authors expect less robot vibration resulting in better targeting accuracy and less strain on the robot gears.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulation of dose reduction in tomosynthesis

Purpose: Methods for simulating dose reduction are valuable tools in the work of optimizing radiographic examinations. Using such methods, clinical images can be simulated to have been collected at other, lower, dose levels without the need of additional patient exposure. A recent technology introduced to healthcare that needs optimization is tomosynthesis, where a number of low-dose projection images collected at different angles is used to reconstruct section images of an imaged object. The aim of the present work was to develop a method of simulating dose reduction for digital radiographic systems, suitable for tomosynthesis. Methods: The developed method uses information about the noise power spectrum (NPS) at the original dose level and the simulated dose level to create a noise image that is added to the original image to produce an image that has the same noise properties as an image actually collected at the simulated dose level. As the detective quantum efficiency (DQE) of digital detectors operating at the low dose levels used for tomosynthesis may show a strong dependency on the dose level, it is important that a method for simulating dose reduction for tomosynthesis takes this dependency into account. By applying an experimentally determined relationship between pixel mean and pixel variance, variations in both dose and DQE in relevant dose ranges are taken into account. Results: The developed method was tested on a chest tomosynthesis system and was shown to produce NPS of simulated dose-reduced projection images that agreed well with the NPS of images actually collected at the simulated dose level. The simulated dose reduction method was also applied to tomosynthesis examinations of an anthropomorphic chest phantom, and the obtained noise in the reconstructed section images was very similar to that of an examination actually performed at the simulated dose level. Conclusions: In conclusion, the present article describes a method for simulating dose reduction suitable for tomosynthesis. However, the method applies equally well to any digital radiographic system, although the benefits of correcting for DQE variations may be smaller.

61 RADIATION PROTECTION AND DOSIMETRY↗

Segmenting CT prostate images using population and patient-specific statistics for radiotherapy

Purpose: In the segmentation of sequential treatment-time CT prostate images acquired in image-guided radiotherapy, accurately capturing the intrapatient variation of the patient under therapy is more important than capturing interpatient variation. However, using the traditional deformable-model-based segmentation methods, it is difficult to capture intrapatient variation when the number of samples from the same patient is limited. This article presents a new deformable model, designed specifically for segmenting sequential CT images of the prostate, which leverages both population and patient-specific statistics to accurately capture the intrapatient variation of the patient under therapy. Methods: The novelty of the proposed method is twofold: First, a weighted combination of gradient and probability distribution function (PDF) features is used to build the appearance model to guide model deformation. The strengths of each feature type are emphasized by dynamically adjusting the weight between the profile-based gradient features and the local-region-based PDF features during the optimization process. An additional novel aspect of the gradient-based features is that, to alleviate the effect of feature inconsistency in the regions of gas and bone adjacent to the prostate, the optimal profile length at each landmark is calculated by statistically investigating the intensity profile in the training set. The resulting gradient-PDF combined feature produces more accurate and robust segmentations than general gradient features. Second, an online learning mechanism is used to build shape and appearance statistics for accurately capturing intrapatient variation. Results: The performance of the proposed method was evaluated on 306 images of the 24 patients. Compared to traditional gradient features, the proposed gradient-PDF combination features brought 5.2% increment in the success ratio of segmentation (from 94.1% to 99.3%). To evaluate the effectiveness of online learning mechanism, the authors carried out a comparison between partial online update strategy and full online update strategy. Using the full online update strategy, the mean DSC was improved from 86.6% to 89.3% with 2.8% gain. On the basis of full online update strategy, the manual modification before online update strategy was introduced and tested, the best performance was obtained; here, the mean DSC and the mean ASD achieved 92.4% and 1.47 mm, respectively. Conclusions: The proposed prostate segmentation method provided accurate and robust segmentation results for CT images even under the situation where the samples of patient under radiotherapy were limited. A conclusion that the proposed method is suitable for clinical application can be drawn.

60 APPLIED LIFE SCIENCES↗

Irradiation of gold nanoparticles by x-rays: Monte Carlo simulation of dose enhancements and the spatial properties of the secondary electrons production

Purpose: The aim of this study is to understand the characteristics of secondary electrons generated from the interaction of gold nanoparticles (GNPs) with x-rays as a function of nanoparticle size and beam energy and thereby further the understanding of GNP-enhanced radiotherapy. Methods: The effective range, deflection angle, dose deposition, energy, and interaction processes of electrons produced from the interaction of x-rays with a GNP were calculated by Monte Carlo simulations. The GEANT4 code was used to simulate and track electrons generated from a 2, 50, and 100 nm diameter GNP when it is irradiated with a 50 kVp, 250 kVp, cobalt-60, and 6 MV photon beam in water. Results: When a GNP was present, depending on the beam energies used, secondary electron production was increased by 10- to 2000-fold compared to an absence of a GNP. Low-energy photon beams were much more efficient at interacting with the GNP by two to three orders of magnitude compared to MV energies and increased the deflection angle. GNPs with larger diameters also contributed more dose. The majority of the energy deposition was outside the GNP, rather than self-absorbed by the nanoparticle. The mean effective range of electron tracks for the beams tested ranged from approximately 3 {mu}m to 1 mm. Conclusions: These simulated results yield important insights concerning the spatial distributions and elevated dose in GNP-enhanced radiotherapy. The authors conclude that the irradiation of GNP at lower photon energies will be more efficient for cell killing. This conclusion is consistent with published studies.

60 APPLIED LIFE SCIENCES↗

Independent quality assurance of a helical tomotherapy machine using the dose magnifying glass

Purpose: Helical tomotherapy is a complex delivery technique, integrating CT image guidance and intensity modulated radiotherapy in a single system. The integration of the CT detector ring on the gantry not only allows patient position verification but is also often used to perform various QA procedures. This convenience lacks the rigor of a machine-independent QA process. Methods: In this article, a Si strip detector, known as the Dose Magnifying Glass (DMG), was used to perform machine-independent QA measurements of the multileaf collimator alignment, leaf open time threshold, and leaf fluence output factor (LFOF). Results: The DMG measurements showed good agreements with EDR2 film for the MLC alignment test while the CT detector agrees well with DMG measurements for leaf open time threshold and LFOF measurements. The leaf open time threshold was found to be approximately 20 ms. The LFOF measured with the DMG agreed within error with the CT detector measured LFOF. Conclusions: The DMG with its 0.2 mm spatial resolution coupled to TERA ASIC allowed real-time high temporal resolution measurements of the tomotherapy leaf movement. In conclusion, DMG was shown to be a suitable tool for machine-independent QA of a tomotherapy unit.

60 APPLIED LIFE SCIENCES↗