Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “chip”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Chip Scale Package Implementation Challenges

The JPL-led MicrotypBGA Consortium of enterprises representing government agencies and private companies have joined together to pool in-kind resources for developing the quality and reliability of chip scale packages (CSPs) for a variety of projects.

chipscale↗

On-Chip p-MOSFET Dosimetry

On-chip p-FETs were developed to monitor the radiation dose of n-well CMOS ICs by monitoring threshold voltage shifts due to radiation induced oxide and interface charge.

FETs↗

Catastrophic fault recovery with self-reconfigurable chips

Mission critical systems typically employ multi-string redundancy to cope with possible hardware failure. Such systems are only as fault tolerant as there are many redundant strings. Once a particular critical component exhausts its redundant spares, the multi-string architecture cannot tolerate any further hardware failure. This paper aims at addressing such catastrophic faults through the use of "Self-Reconfigurable Chips" as a last resort effort to "repair" a faulty critical component.

Chau, Savio N.↗

Cold Survivable Current Sense Multi-Chip Module

This paper will present the design of a Current Sense Module (CSM) used to measure motor phase currents that is capable of surviving the harsh ambient environment of ocean worlds, such as Europa and Enceladus. The CSM module is fabricated by i3 Electronics using their Multi-Chip Module (MCM) technology with techniques developed by JPL to allow this module to survive temperatures down to -184°C. This module greatly improves the ability to measure phase and bridge current which can be problematic in extreme environments. In addition, by packaging these electronics at the die level, we achieve significant weight and size savings. This module is one of several modules that employ similar techniques that are integrated into a distributed or centralized motor controller. This paper will discuss the module’s design along with a summary of our test results.

Cheng, Ben↗

Deep Space Radiation Affects Neurovascular Functions in Human Organ-on-a-Chip Models

A major health risk for human deep space exploration is central nervous system (CNS) damage by galactic cosmic ray radiation. Simulated galactic cosmic rays or their components, especially the high- linear energy transfer (LET) particles such as 56 Fe ions, cause CNS damage, neuroinflammation and cognitive dysfunction in rodent models, but their effects on human CNS remain to be investigated. CNS damage from any insult, including ionizing radiation, is partially mediated by the blood-brain barrier (BBB), which regulates the interactions between CNS and the rest of the body. The main cellular regulators of BBB permeability are astrocytes, which also modulate neuronal health and neuroinflammation. However, there have been few studies on BBB and astrocyte functions in regulating CNS responses, especially in human tissue/organ analogs. Therefore, we utilized a high-throughput human 3D organ-on-a-chip system, seeded with induced pluripotent stem cell-derived endothelial cells, astrocytes and neurons, to study human neurovascular responses to simulated deep space radiation. We investigated BBB permeability, oxidative stress, cellular and tissue damage, and secreted factors over the time period of 24 hours-1 week after irradiation with 0.25-0.5 Gy 5-ion simplified simulated galactic cosmic rays and 0.3-0.8 Gy high-LET 600MeV/n 56 Fe particles, and compared the outcomes to low-LET irradiation with 0.1-1 Gy doses of X-rays and gamma rays. Both high and low-LET radiation increased neurovascular permeability, caused oxidative stress, damaged endothelial cells and tight junctions, and altered expression of inflammatory cytokines. Ionizing radiation- induced neurovascular permeability and oxidative stress peaked at 3 days after irradiation and were further exacerbated by the presence of astrocytes. Furthermore, in response to particle irradiation, astrocytes stimulated interleukin-1 signaling by inhibiting the expression of interleukin-1 receptor antagonist. Thus, we also evaluated interleukin-1 receptor antagonist as a potential countermeasure against particle radiation. Ultimately, our results may help develop countermeasures to mitigate human CNS damage in deep space exploration.

Sonali D Verma↗

Minimally Intrusive Single-Chip Recession/Temperature Sensors for Spacecraft Thermal Protection Systems

We report the initial results of ongoing development of minimally intrusive, single-chip integrated capacitive recession/temperature sensors that would provide real-time monitoring of ablation recession of heatshield thermal protection systems (TPS) during spacecraft atmospheric entry. This work, which was performed using Phenolic Impregnated Carbon Ablator (PICA), is also to demonstrate the ease of sensor insertion during TPS manufacturing, thereby resulting in faster, low-cost, uniform sensor assembly, and spatial distribution, without compromising TPS structural integrity. Using oxy-acetylene flame at 500 W-cm-2 heat flux for 16 seconds, the average recession depth of 3.25 mm was obtained. Some measurement problems were encountered in this first attempt. However, the initial results obtained are in relatively good agreement with published data, and offer promise of future improvement based on lessons learned.

Recession↗

Neurovascular Responses to Simulated Deep Space Radiation in a Human Organ-on-a-Chip Model

A major health risk for human deep space exploration is central nervous system (CNS) damage by galactic cosmic ray radiation. Simulated galactic cosmic rays or their components, especially the high-linear energy transfer (LET) particles such as 56Fe ions, have been shown to cause CNS damage, neuroinflammation and cognitive dysfunction in rodent models, but their effects on human CNS remain to be investigated. CNS damage from any insult, including ionizing radiation, is partially mediated by the blood-brain barrier (BBB), which regulates interactions between CNS and the rest of the body. The main cellular regulators of BBB permeability are astrocytes, which also modulate neuroinflammation. However, there have been few studies on BBB and astrocyte functions in regulating CNS responses, especially in human tissue analogs. Therefore, we utilized a high-throughput 3D organ-on-a-chip system, seeded with human induced pluripotent stem cell-derived astrocytes and brain endothelial cells, or brain endothelial cells alone, to study human neurovascular responses to simulated deep space radiation. We investigated the permeability and morphology of vascular structures formed by endothelial cells, as well as oxidative stress and secreted cytokines and chemokine levels over 1-7 days after irradiation with 0.25 – 0.5 Gy 5-ion simplified simulated galactic cosmic rays or 0.3 – 0.8 Gy high-LET 600 MeV/n 56Fe particles, and compared the outcomes to low-LET X-ray irradiation. We observed that simulated deep space radiation caused delayed astrocyte activation in a pattern resembling CNS responses to brain injury, caused oxidative stress and the production of inflammatory cytokines, and compromised BBB integrity by damaging tight junctions, thus increasing vascular permeability. Furthermore, our results indicate that astrocytes have a dual role in regulating radiation responses: they exacerbate blood-brain barrier permeability early after irradiation, followed by switching to a more protective scar-like phenotype by reducing oxidative stress and pro-inflammatory cytokine and chemokine secretion. In a follow-up study using the same platform, we investigated the dose-rate effects of ionizing radiation, by exposing our model to chronic, low dose-rate, gamma radiation. Our model was significantly improved by adding additional cell types composing the BBB, modelling immune cell infiltration into the brain, and studying the effect of an antioxidant, to measure more complex outcomes and model more closely the effect of deep space radiation on the human BBB. In summary, our results present a human neurovascular model for space radiation studies and potential future automated payload adaptation, and suggest astrocyte regulatory mechanisms as targets for countermeasures to mitigate human neurovascular impairments during deep space exploration.

Ionizing radiation↗

Proton Testing of AMD v1202b System on Chip

Single-Event Effects (SEE) testing was previously conducted on the AMD v1200 System on Chip (SoC) at Massachusetts General Hospital’s (MGH) Francis H. Burr Proton Therapy Center on May 28, 2022, using 200-MeV protons.

Edward J Wyrwas↗

Benchmarking and Testing of Qualcomm Snapdragon System-on-Chip for JPL Space Applications and Missions

As some space missions become more challenging due to new environments, greater distances, or more limited size, weight, and power (SWaP) constraints, spacecraft avionics must adapt to allow the spacecraft to be more autonomous and agile---eliminating the Spacecraft-Earth-Spacecraft feedback loop whenever possible. Prime examples of such missions include Aerobots (such as Ingenuity with extremely low SWaP constraints and demanding signal/image processing during flight) and landers in possibly hostile environments (such as a Europa lander mission, with limited communication capacity, high latency, and constrained power budget). To address these challenges, JPL worked with Qualcomm to demonstrate the use of their Snapdragon 801 system-on-chip (SoC) onboard the Ingenuity Helicopter on Mars. The Qualcomm Snapdragon SoC contains various subsystems, including an ARM cluster, a Graphics processing unit, a Digital Signal Processing subsystem, a Neural Processing Engine, Image Signal Processing subsystem, among others. Since the success of Ingenuity, JPL is continuing to work with Qualcomm to address other applications of the Snapdragon SoC technology. This includes the deployment of two 855 Snapdragon development boards onboard the International Space Station (ISS) for successful in-situ benchmarking of applications in space (beyond those tested on Ingenuity). In this paper, we will examine the performance of various applications that have been identified to benefit from greater onboard computational capability. These applications include (among others): machine vision algorithms that are expected to be critical in autonomous entry-descent-and-landing scenarios and real-time Aerobot flight navigation; Hyperspectral compression algorithms; Synthetic Aperture Radar Processing along with various instrument processing algorithms. We discuss how the infusion of Qualcomm's Snapdragon SoC is capable of enabling missions that may not have been able to achieve their goals with traditional flight computing. In addition, we also show that for some algorithms, the software implementation on the Snapdragon SoC outperforms traditional FPGA implementations.

Cretu, Vlad↗

Stress Testing of Chip Aluminum Polymer Capacitors

Layered aluminum polymer capacitors (APC) may be viable replacements to current chip tantalum capacitors due to their lower ESR, weight, and smaller size. So far, there is a lack of information regarding the reliability of these parts. Available technical literature is mostly related to the effect on humidity. Although APCs have a limited moisture resistance, it may be contained to the level sufficient for space applications. In this work, seven types of commercial APCs manufactured by four vendors and rated to voltages from 6.3 to 35 V were used to evaluate reliability of the parts under environmental stresses and highly accelerated life tests. Characteristics of the parts, including breakdown voltages, the level of anomalous charging currents (ACC), capacitance, DF, ESR and leakage currents were measured in the process of storage at high-temperatures (from 100 to 150 °C) and high humidity at 85 °C. Monitored highly accelerated life tests have been carried out at temperatures of 85 °C and 125 °C and voltages varying from 1.2 to 1.9 times the rated voltage. Degradation processes and reliability of APCs have been analyzed and compared to polymer tantalum capacitors.

Alexander Teverovsky↗

Design of On-chip Power Transport and Coupling Components for a Silicon Woodpile Accelerator

Three-dimensional woodpile photonic bandgap (PBG) waveguide enables high-gradient and efficient laser driven acceleration, while various accelerator components, including laser couplers, power transmission lines, woodpile accelerating and focusing waveguides, and energy recycling resonators, can be potentially integrated on a single monolithic structure via lithographic fabrications. This paper will present designs of this on-chip accelerator based on silicon-on-insulator (SOI) waveguide. Laser power is coupled from free-space or fiber into SOI waveguide by grating structures on the silicon surface, split into multiple channels to excite individual accelerator cells, and eventually gets merged into the power recycle pathway. Design and simulation results will be presented regarding various coupling components involved in this network.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flip-chip and backside techniques.

State-of-the-art techniques for failure localization and design modification through bulk silicon are essential for multi-level metallization and new, flip chip packaging methods. The tutorial reviews the transmission of light through silicon, sample preparation, and backside defect localization techniques that are both currently available and under development. The techniques covered include emission microscopy, scanning laser microscope based techniques (electrooptic techniques, LIVA and its derivatives), and other non-IR based tools (FIB, e-beam techniques, etc.).

99 GENERAL AND MISCELLANEOUS↗

Microstructural characterization of Ti-6Al-4V metal chips by focused ion beam (FIB) and transmission electron microscopy (TEM)

The microstructure of the secondary deformation zone (SDZ) near the cutting surface in metal chips of Ti-6Al-4V formed during machining was investigated using focused ion beam (FIB) specimen preparation and transmission electron microscopy (TEM) imaging. Use of the FIB allowed precise extraction of the specimen across this region to reveal its inhomogeneous microstructure resulting from the non-uniform distribution of strain, strain rate, and temperature generated during the cutting process. Initial imaging from conventional TEM foil preparation revealed microstructures ranging from heavily textured to regions of fine grains. Using FIB preparation, the transverse microstructure could be interpreted as fine grains near the cutting surface which transitioned to coarse grains toward the free surface. At the cutting surface a 10 nm thick recrystallized layer was observed capping a 20 nm thick amorphous layer.

36 MATERIALS SCIENCE↗

Chip-based in situ hybridization for identification of bacteria from the human microbiome.

The emerging field of metagenomics seeks to assess the genetic diversity of complex mixed populations of bacteria, such as those found at different sites within the human body. A single person's mouth typically harbors up to 100 bacterial species, while surveys of many people have found more than 700 different species, of which {approx}50% have never been cultivated. In typical metagenomics studies, the cells themselves are destroyed in the process of gathering sequence information, and thus the connection between genotype and phenotype is lost. A great deal of sequence information may be generated, but it is impossible to assign any given sequence to a specific cell. We seek non-destructive, culture-independent means of gathering sequence information from selected individual cells from mixed populations. As a first step, we have developed a microfluidic device for concentrating and specifically labeling bacteria from a mixed population. Bacteria are electrophoretically concentrated against a photopolymerized membrane element, and then incubated with a specific fluorescent label, which can include antibodies as well as specific or non-specific nucleic acid stains. Unbound stain is washed away, and the labeled bacteria are released from the membrane. The stained cells can then be observed via epifluorescence microscopy, or counted via flow cytometry. We have tested our device with three representative bacteria from the human microbiome: E. coli (gut, Gram-negative), Lactobacillus acidophilus (mouth, Gram-positive), and Streptococcus mutans (mouth, Gram-positive), with results comparable to off-chip labeling techniques.

59 BASIC BIOLOGICAL SCIENCES↗

Chip scale mechanical spectrum analyzers based on high quality factor overmoded bulk acouslic wave resonators

The goal of this project was to develop high frequency quality factor (fQ) product acoustic resonators matched to a standard RF impedance of 50 {Omega} using overmoded bulk acoustic wave (BAW) resonators. These resonators are intended to serve as filters in a chip scale mechanical RF spectrum analyzer. Under this program different BAW resonator designs and materials were studied theoretically and experimentally. The effort resulted in a 3 GHz, 50 {Omega}, sapphire overmoded BAW with a fQ product of 8 x 10{sup 13}, among the highest values ever reported for an acoustic resonator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On-chip Optical Filters with Designable Characteristics Based on an Interferometer with Embedded Silicon Photonic Structures

We demonstrate chip-scale flat-top filters at near-IR wavelengths using negative index photonic crystal based Mach-Zehnder interferometers. Supported by full three-dimensional numerical simulations, we experimentally demonstrate a new approach for engineering high-pass, low-pass, bandpass, and band-reject filters, based on designing the photonic band diagram both within the bandgap frequency region and away from it. We further show that our approach can be used to design filters that have tunable multilevel response for different sections of the spectrum and for different polarizations. This configuration enables deterministic control of the bandwidth and the rejection ratio of filters for integrated photonic circuits.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The FE-I4 Pixel Readout Chip and the IBL Module

FE-I4 is the new ATLAS pixel readout chip for the upgraded ATLAS pixel detector. Designed in a CMOS 130 nm feature size process, the IC is able to withstand higher radiation levels compared to the present generation of ATLAS pixel Front-End FE-I3, and can also cope with higher hit rate. It is thus suitable for intermediate radii pixel detector layers in the High Luminosity LHC environment, but also for the inserted layer at 3.3 cm known as the 'Insertable B-Layer' project (IBL), at a shorter timescale. In this paper, an introduction to the FE-I4 will be given, focusing on test results from the first full size FE-I4A prototype which has been available since fall 2010. The IBL project will be introduced, with particular emphasis on the FE-I4-based module concept.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗