Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capacity test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Performance of Low Temperature Electrolytes in Experimental and Prototype Li-Ion Cells

Due to their attractive properties and proven success, Li-ion batteries have become identified as the battery chemistry of choice for a number of future NASA missions. A number of these applications would be greatly benefited by improved performance of Li-ion technology over a wider operating temperature range, especially at low temperatures, such as future ESMD missions. In many cases, these technology improvements may be mission enabling, and at the very least mission enhancing. In addition to aerospace applications, the DoE has interest in developing advanced Li-ion batteries that can operate over a wide temperature range to enable terrestrial HEV applications. Thus, our focus at JPL in recent years has been to extend the operating temperature range of Li-ion batteries, especially at low temperatures. To accomplish this, the main focus of the research has been devoted to developing improved lithium-ion conducting electrolytes. In the present paper, we would like to present some of the results we have obtained with ethylene carbonate-based electrolytes optimized for low temperature in experimental MCMB-LiNixCo1_x0 2 cells. In addition to obtaining discharge and charge rate performance data at various temperatures, electrochemical measurements were performed on individual electrodes (made possible by the incorporation of Li reference electrodes), including EIS, linear polarization and Tafel polarization measurements. The combination of techniques enables the elucidation of various trends associated with electrolyte composition. In addition to investigating the behavior in experimental cells, the performance of many promising low temperature electrolytes was demonstrated in large capacity, aerospace quality Li-ion prototype cells. These cells were subjected to a number of performance tests, including discharge rate characterization, charge rate characterization, cycle life performance at various temperatures, and power characterization tests.

Li-ion batteries↗

Performance Testing of Yardney Li-Ion Cells and Batteries in Support of JPL's 2009 Mars Science Laboratory Mission

In 2009, JPL is planning to launch an unmanned rover mission to the planet Mars. This mission, referred to as the Mars Science Laboratory (MSL), will involve the use of a rover that is much larger than the previously developed Spirit and Opportunity Rovers for the 2003 Mars Exploration Rover (MER) mission, that are currently still in operation on the surface of the planet after more than three years. Part of the reason that the MER rovers have operated so successfully, far exceeding the required mission duration of 90 sols, is that they possess robust Li-ion batteries, manufactured by Yardney Technical Products, which have demonstrated excellent life characteristics. Given the excellent performance characteristics displayed, similar lithium-ion batteries have been projected to successfully meet the mission requirements of the up-coming MSL mission. Although comparable in many facets, such as being required to operate over a wide temperature range (-20 to 40 C), the MSL mission has more demanding performance requirements compared to the MER mission, including much longer mission duration (approx. 687 sols vs. 90 sols), higher power capability, and the need to withstand higher temperature excursions. In addition, due to the larger rover size, the MSL mission necessitates the use of a much larger battery to meet the energy, life, and power requirements. In order to determine the viability of meeting these requirements, a number of performance verification tests were performed on 10 Ah Yardney lithium-ion cells (MER design) under MSL-relevant conditions, including mission surface operation simulation testing. In addition, the performance of on-going ground life testing of 10 Ah MER cells and 8-cell batteries will be discussed in the context of capacity loss and impedance growth predictions.

MSL Rover↗

Analysis of Performance Degradation of Silica Gels After Extended Use Onboard the ISS

The teardown of two flight desiccant beds from the Carbon Dioxide Removal Assembly (CDRA) revealed significant discoloration of the silica gel near the bed inlet as well as a coincidental performance loss. This material was analyzed for the presence of chemical contaminants, physical porosity changes, and adsorption performance. The material characteristics are compared against the location in the bed from which they were sampled in order to develop profiles through the bed. Additional testing of the beds prior to teardown provided more data points. Possible mechanisms for the loss of capacity are provided though no root cause has been found. Extrapolation of the performance loss is used to estimate the required oversizing of the silica gel layer for long-term operation.

Cmarik, Gregory E.↗

Analysis of Performance Degradation of Silica Gels After Extended Use Onboard the ISS

The disassembly of two flight desiccant beds from the Carbon Dioxide Removal Assembly (CDRA) revealed significant discoloration of the silica gel near the bed inlet as well as a coincidental performance loss. This material was analyzed for the presence of chemical contaminants, physical porosity changes, and adsorption performance. The material characteristics are compared against the location in the bed from which they were sampled in order to develop profiles through the bed. Additional testing of the beds prior to disassembly provided more data points. Possible mechanisms for the loss of capacity are provided though no root cause has been confirmed. Extrapolation of the performance loss is used to estimate the required oversizing of the silica gel layer for long-term operation.

Cmarik, Gregory E.↗

Techno-Economic Analysis of Green Hydrogen Energy Storage in A Cryogenic Flux Capacitor

The Cryogenic Flux Capacitor (CFC) is a cold, dense energy storage core that is being studied in the cryo-compressed, about 300 bar and 80K, region of gaseous hydrogen (GH 2 ) storage and liquid hydrogen (LH 2 ) region near the normal boiling point. Hydrogen storage is improved by physically bonding the molecules within the nanoscale pores of the aerogel composite blanket material. The process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (~1,000 m 2 /g) allows its storage performance to easily exceed capacities of high-pressure GH 2 storage for an equivalent volume. With the integrated aerogel, subscale tests have shown that storage is increased by about 36% over a simple tank filled with GH 2 at the same operating temperature and pressure. For LH 2 conditions, the CFC is shown to operate at improved densities, but testing is ongoing. For the techno-economic analysis (TEA), the source of hydrogen is compared between onsite steam methane reforming (SMR) and onsite solar photovoltaic (PV) panels providing power to electrolyzers to produce green GH 2 . The TEA compares pure hydrogen produced at a small scale for a 25 MW power system and at a large scale in a 500 MW power system. The system allowed for hydrogen imports and exports at a set price with a tank sized for 10 hours of power production. The two power producing technologies are a combined cycle gas turbine (CCGT) and hydrogen fuel cells. The SMR system uses natural gas as an input and includes a carbon capture and storage (CCS) system. The levelized cost of electricity (LCOE), levelized cost of hydrogen (LCOH), and levelized cost of storage (LCOS) are developed based on the capital cost and operating cost of the systems. The results are shown for current costs using a 2021 benchmark and DOE projections for cost improvements by 2030. The TEA showed that onsite hydrogen generation from SMR has an LCOH of about 1.4 to 2 USD per kg over the life of the plant and the PV hydrogen production LCOH is about 5.2 to 5.5 USD per kg. The LCOS of conventional GH 2 systems is estimated to be $210/MWh and cost of storage for LH 2 systems is $205/MWh for fuel cell systems and $249/MWh for CCGT systems. CFC improved the LCOS of all these systems to $198/MWh, $191/MWh and $233/MWh respectively. The LCOE also improved with conventional systems between $171/MWh and $228/MWh improved by CFC to between $167/MWh and $212/MWh. Using projections for improvement in costs following DOE’s goals by 2030, green hydrogen improved to as low as $78/MWh LCOS and LCOE for conventional cases. CFC improved over conventional storage with the lowest LCOS being $62/MWh and the lowest LCOE being $73/MWh. These results correspond to an LCOH of $2/kg. Finally, the TEA shows how LCOE is improved for hydrogen conditioning and storage over conventional systems and caverns in the 10 to 50 hour range.

Joshua Schmitt↗

Development of a low temperature phase change material package

Test data obtained for a low temperature phase change material (PCM) canisters are presented. The canister was designed to provide up to 30 w-hrs of storage capacity at approximately -90 C with an overall thermal conductance which is greater than 8 w/deg C. N-heptane which is an n-paraffin and has a -90.6 C freezing point was used as the working fluid. The canister was fabricated from aluminum and has an aluminum honeycomb core. Its void volume permits service temperatures up to 70 C. Results obtained from component and system's tests indicate well defined melting and freezing points which are repeatable and within 1 C of each other. Subcooling effects are less than 0.5 C and are essentially negligible. Measured storage capacities are within 94 to 88% the theoretical.

Brennan, P. J.↗

Static Torsion Testing and Modeling of a Variable Thickness Hybrid Composite Bull Gear

Torsional strength of a variable thickness hybrid gear web was measured by performing static testing on the part in a large torsion test frame. The outer rim of the hybrid gear web was fixed to the bottom of the test frame and loading was applied to the web through a shaft. The test setup included the installation of digital image correlation (DIC) systems to obtain deformation and strain measurements from the surfaces of the hybrid gear web and the mechanical test equipment to ensure reliability of the test. The results indicated that the variable thickness hybrid gear web achieved approximately twice the torsional strength compared to that of previous hybrid gear designs. The DIC analysis showed significantly more straining of the loading shaft than the actual test article. Additionally, the results demonstrated the importance and affect that the metallic, lobed interlock features had on the principal strain and out-of-plane displacement fields. The analysis revealed that the fixed outer rim was in fact rotating and a rigid body motion compensation (RBMC) function was computed to determine the actual rotation of the hub and composite web relative to the outer rim. Modeling simulations were performed for the variable thickness hybrid gear web and correlated well with the RBMC rotational deformation seen in the DIC analysis. In addition to benchmarking the load capacity of the hybrid gear web, measuring its strength is useful information to define the parameters needed for dynamic, endurance, and other testing of the part.

Johnston, Joel P.↗

Results of Skylab medical experiment M171: Metabolic activity

The experiment was conducted to establish whether man's ability to perform mechanical work would be progressively altered as a result of exposure to the weightless environment of space flight. The Skylab crewmen exercised on a bicycle ergometer at workloads approximating 25, 50, and 75 percent of their maximum aerobic capacity. The physiological parameters monitored were respiratory gas exchange, blood pressure, and vectorcardiogram/heart rate. The results of these tests indicate that the crewmen had no significant decrement in their responses to exercise during their exposure to zero gravity. The results of the third manned Skylab mission (Skylab 4) are presented and a comparison is made of the overall results obtained from the three successively longer Skylab manned missions. The Skylab 4 crewmembers' 84-day in-flight responses to exercise were no worse and were probably better than the responses of the crewmen on the first two Skylab missions. Indications that exercise was an important contributing factor in maintaining this response are discussed.

Michel, E. L.↗

Preprototype vapor compression distillation subsystem

A three-person capacity preprototype vapor compression distillation subsystem for recovering potable water from wastewater aboard spacecraft was designed, assembled, and tested. The major components of the subsystem are: (1) a distillation unit which includes a compressor, centrifuge, central shaft, and outer shell; (2) a purge pump; (3) a liquids pump; (4) a post-treat cartridge; (5) a recycle/filter tank; (6) an evaporator high liquid level sensor; and (7) the product water conductivity monitor. A computer based control monitor instrumentation carries out operating mode change sequences, monitors and displays subsystem parameters, maintains intramode controls, and stores and displays fault detection information. The mechanical hardware occupies 0.467 m3, requires 171 W of electrical power, and has a dry weight of 143 kg. The subsystem recovers potable water at a rate of 1.59 kg/hr, which is equivalent to a duty cycle of approximately 30% for a crew of three. The product water has no foul taste or odor. Continued development of the subsystem is recommended for reclaiming water for human consumption as well as for flash evaporator heat rejection, urinal flushing, washing, and other on-board water requirements.

Ellis, G. S.↗

Phase-locked telemetry system for rotary instrumentation of turbomachinery, phase 1

A telemetry system for use in making strain and temperature measurements on the rotating components of high speed turbomachines employs phase locked transmitters, which offer greater measurement channel capacity and reliability than existing systems which employ L-C carrier oscillators. A prototype transmitter module was tested at 175 C combined with 40,000 g's acceleration.

Adler, A.↗

Electromagnetic measurement of lightning strikes to aircraft

Recent in-flight direct-strike lightning research, using an NASA F-1068 aircraft, is reviewed. The instrumentation system which records the rates of change of electric and magnetic flow density at several locations on the aircraft and rate of change of strike current to the boom is described. The measurement parameters are: rate of change of electric flux density over a range of 50 amperes per square meter, rate of change of magnetic flux density over a range of 20,000 tesla per second, and rate of change of strike current over a range of 100 kilo-amperes per microsecond. The isolated and shielded instrumentation system employs high-sample-rate digital transient recorders with augmented memory capacity and a wideband analog recorder for data acquisition and recording. The data obtained during the 1980 flight test program are presented and the data significance is discussed.

Pitts, F. L.↗

Dynamic characteristics of the 40- by 80-/80- by 120-foot wind tunnel drive fan blades

The existing 40- by 80-Foot Wind Tunnel at Ames Research Center is being modified to upgrade and expand the research capabilty of the facility. The modification project includes an enhancement of the wind-tunnel drive power capability by installing large capacity electric motors and new drive fans to attain higher airspeeds in the existing 40- by 80-ft test section. It also involves the constructin of a new tunnel leg which includes a larger 80-- by 120-ft test section. The 40-by 80-ft test section will have a maximum airspeed approaching 300 knots. It was previously limited to about 200 knots. The maximum airspeed of the 80- by 120-ft test section will be about 100 knots. Becaue of the critical nature of the drive fans in the operation of the facility, an extensive effort was undertaken to verify, for each blade-retention system, its structural integrity and its dynamic characteristics.

Warmbrodt, W.↗

Large capacity cryopropellant orbital storage facility

A comprehensive study was performed to develop the major features of a large capacity orbital propellant storage facility for the space-based cryogenic orbital transfer vehicle. Projected propellant usage and delivery schedules can be accommodated by two orbital tank sets of 100,000 lb storage capacity, with advanced missions expected to require increased capacity. Information is given on tank pressurization schemes, propellant transfer configurations, pump specifications, the refrigeration system, and flight tests.

Schuster, J. R.↗

The lambda point experiment in microgravity

The motivation and potential for performing very high resolution measurements of the heat capacity singularity at the lambda point of helium in microgravity conditions was briefly discussed. It is clear that tests extending deep into the asymptotic region can be performed, where the theoretical predictions take on their simplest form. This advantageous situation should lead to a major improvement in the understanding of the range of applicability of current theoretical ideas in this field. The lambda transition holds out the prospect of giving the maximum advance of any system, and with the application of cryogenic techniques, the potential of this system can be realized. The technology for the initial experiments is already developed, and results could be obtained in 1990.

Lipa, J. A.↗

KOH concentration effect on the cycle life of nickel-hydrogen cells. Part 4: Results of failure analyses

KOH concentration effects on cycle life of a Ni/H2 cell have been studied by carrying out a cycle life test of ten Ni/H2 boiler plate cells which contain electrolytes of various KOH concentrations. Failure analyses of these cells were carried out after completion of the life test which accumulated up to 40,000 cycles at an 80 percent depth of discharge over a period of 3.7 years. These failure analyses included studies on changes of electrical characteristics of test cells and component analyses after disassembly of the cell. The component analyses included visual inspections, dimensional changes, capacity measurements of nickel electrodes, scanning electron microscopy, BET surface area measurements, and chemical analyses. Results have indicated that failure mode and change in the nickel electrode varied as the concentration was varied, especially, when the concentration was changed from 31 percent or higher to 26 percent or lower.

Lim, H. S.↗

KOH concentration effect on the cycle life of nickel-hydrogen cells. IV - Results of failure analysis

Potassium hydroxide concentration effects on the cycle life of a Ni/H2 cell have been studied by carrying out a cycle life test on ten Ni/H2 boiler plate cells which contain electrolytes of various KOH concentrations. Failure analyses of these cells were carried out after completion of the life test, which accumulated up to 40,000 cycles at an 80-percent depth of discharge over a period of 3.7 years. These failure analyses included studies on changes of electrical characteristics of test cells, and component analyses after disassembly of the cell. The component analyses included visual inspections, dimensional changes, capacity measurements of nickel electrodes, scanning electron microscopy, surface area measurements, and chemical analyses. Results have indicated that failure mode and change in the nickel electrode varied as the concentration was varied, especially when the concentration was changed from 31 percent or higher to 26 percent or lower.

Lim, H. S.↗

Liquid oxygen/metal gelled monopropellants

The objectives of this program were to establish the feasibility of metallized/liquid oxygen monopropellants and select the best monopropellant formulation for continued study. The metal powders mixed with the liquid oxygen were aluminum/magnesium (80/20), silicon and iron (Iron was only tested for burning properties). The formulations were first evaluated on whether they detonated when ignited or burned. The formulations only burned when ignited. The viscosity for the formulations ranged from 900 cps to 100 cps at shear rates up to 300 seconds(sup -1). Two percent (by weight) of Cab-O-Sil was added to the aluminum and aluminum/magnesium formulations for gelling while the silicon formulation used three percent. Within a seven hour period, settling was suggested only in the 29 percent aluminum and 29 percent aluminum/magnesium formulations. The monopropellants were burned in a cylinder submerged in a liquid nitrogen bath. Experimental data at ambient pressure indicated that the monopropellants were extinguished when the flame front reached regions submerged under the liquid nitrogen. The burn rate increased dramatically when burned in a cylinder enclosure with less heat sink available to the monopropellant. The test results were inconclusive as to whether the increased burn rate was due to the lower heat sink capacity or the small amount of pressure (2 psi) generated during the burning of the monopropellant. The burning of the aluminum and aluminum/magnesium resulted in a brilliant white flame similar to that of an arc welder. These monopropellants burned in a pulsating manner with the aluminum/magnesium appearing to have less pulsating combustion. The silicon monopropellant burned with an orange glow. No sparks or energetic burning was apparent as with the aluminum or aluminum/magnesium.

Wickman, John H.↗

Evaluation of Navy 9 cst Oil in Bell Helicopter M412 HP Gearboxes

Tests were conducted with 5 and 9 centistoke lubricants in three different helicopter gearboxes, a main transmission, a 42' gearbox and a tailrotor gearbox. The objective of the tests was to observe and measure the difference in the performance of the lubrication systems due to the viscosity difference between the two test lubricants. The 9 centistoke oil has been developed to provide higher component film thickness, increased load carrying capacity and improved corrosion resistance which will provide increased life for drive system gears and bearings.

TRANSMISSION FLUIDS↗