Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capacity test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Evaluation program for secondary spacecraft cells. Initial evaluation tests of General Electric Company 4.0 ampere-hour nickel-cadmium spacecraft cells for the AMPTE satellite program

Cells found to have electrolyte leakage, internal shorts, low capacity, or inability of any cell to recover its open circuit voltage above 1.150 volts during the internal short test are addressed. The Active Magnetic Particle Tracer Explorer (AMPTE) cell design was characterized and the effects of specific mission parameters on cell life were demonstrated.

Harkness, J. D.↗

Provider of Services for Urban Air Mobility (PSU) Prototype Simulation (X5) Final Report

Urban Air Mobility (UAM) is a new air transportation service concept to carry passengers or cargo in metropolitan areas, leveraged by innovative aircraft and air traffic automation technologies. NASA has conducted a series of simulations, called the X-series simulation, to evaluate the UAM concept of operations and support the development of airspace procedures and services for UAM operations. The simulation called “X5” was conducted in 2023 to test a Provider of Services for UAM (PSU) prototype developed by NASA for UAM flight planning, strategic conflict management support, and data exchange between UAM operators. In this simulation, two strategic conflict management capabilities, Demand-Capacity Balancing and Sequencing and Scheduling, were further investigated. This document describes the UAM system architecture modeled, the X5 simulation environment to be executed (e.g., traffic scenario and UAM airspace construct), and the strategic conflict management processes developed and evaluated in this study. Then, the simulation results are provided using several system performance metrics, such as the number of operations planned and activated, demand-capacity imbalances detected and resolved, and pre-departure delays. Based on these metrics, the test findings and lessons learned from this simulation are discussed. NASA developed a PSU prototype as part of a reference implementation of UAM system architecture and evolved strategic conflict management capabilities for UAM operations from the previous collaborative simulations with industry partners. Below is the summary of the achievements: - Aligned NASA’s UAM reference architecture with the FAA’s UAM ConOps notional architecture - Extended UAM airspace management capabilities to include 1) Demand-Capacity Balancing (DCB) to ensure operators coordinate planned usage of shared vertiports, and 2) Sequencing and Scheduling (S&S) at UAM corridor entry and exit points to help facilitate an orderly flow of traffic - Defined the PSU information exchange APIs and requirements towards informing industry standards - Developed and tested a NASA PSU prototype as reference implementation to validate the requirements and APIs - Developed a prototype service connecting NASA’s PSU and the FAA system for testing future PSU-ATM interface requirements - Tested NASA-developed assumptions for UAM operations such as airspace design, procedures, vehicle performance, and strategic conflict management methods to inform future Cooperative Operating Practices (COPs) development with industry - Evaluated system performance metrics such as number of simultaneous operations and ground delays that can help define system-level requirements. The simulation results showed that the UAM traffic demand could be managed to minimize the needs of tactical separation provision with ground delays assigned by DCB and S&S. These accomplishments and the lessons learned from the PSU Prototype X5 simulation activities will be valuable inputs for the Air Mobility Pathfinders (AMP) project, which is NASA’s new project to create and evaluate a reference architecture for safe, secure, and scalable UAM operations.

Simulation↗

Performance and Safety Testing of Cylindrical Moli Lithium-Ion Cells

The Moli lithium-ion cells were tested under normal and abuse conditions. The cells exhibit only 50% of their original capacity at about -10 C. The optimum charge/discharge rate with the least percentage loss in capacity is C/2 charge and C/4 discharge. The cells did not explode or go into a thermal runaway during venting at very high temperatures. They exhibited good tolerance under the vibration conditions tested and could potentially be used in the build up of large batteries that have high current pulse (up to 3C) applications.

Jeevarajan, Judith A.↗

Dynamic modulus and damping of boron, silicon carbide, and alumina fibers

The dynamic modulus and damping capacity for boron, silicon carbide, and silicon carbide-coated boron fibers were measured from -190 to 800 C. The single fiber vibration test also allowed measurement of transverse thermal conductivity for the silicon carbide fibers. Temperature-dependent damping capacity data for alumina fibers were calculated from axial damping results for alumina-aluminum composites. The dynamic fiber data indicate essentially elastic behavior for both the silicon carbide and alumina fibers. In contrast, the boron-based fibers are strongly anelastic, displaying frequency-dependent moduli and very high microstructural damping. The single fiber damping results were compared with composite damping data in order to investigate the practical and basic effects of employing the four fiber types as reinforcement for aluminum and titanium matrices.

Dicarlo, J. A.↗

Performance and Safety Testing of Varta Li-Ion Polymer Cells

Varta Cell Characteristics: Voltage : 3.7 V Capacity : 1.21 Ah Dimensions : 5mm X 37mm X 38.5 mm MOSFET switches for Overvoltage and Undervoltage. Initial Screening Results 29 Cells delivered: Statistics on Ph ysical Screening: Thickness (mm): Average- 5.08; Weight(g)- 22.8938; OCV (V)- 3.787; CCV (V)- 3.491.

Patel, Pranav↗

UNIX-based operating systems robustness evaluation

Robust operating systems are required for reliable computing. Techniques for robustness evaluation of operating systems not only enhance the understanding of the reliability of computer systems, but also provide valuable feed- back to system designers. This thesis presents results from robustness evaluation experiments on five UNIX-based operating systems, which include Digital Equipment's OSF/l, Hewlett Packard's HP-UX, Sun Microsystems' Solaris and SunOS, and Silicon Graphics' IRIX. Three sets of experiments were performed. The methodology for evaluation tested (1) the exception handling mechanism, (2) system resource management, and (3) system capacity under high workload stress. An exception generator was used to evaluate the exception handling mechanism of the operating systems. Results included exit status of the exception generator and the system state. Resource management techniques used by individual operating systems were tested using programs designed to usurp system resources such as physical memory and process slots. Finally, the workload stress testing evaluated the effect of the workload on system performance by running a synthetic workload and recording the response time of local and remote user requests. Moderate to severe performance degradations were observed on the systems under stress.

Chang, Yu-Ming↗

Hydraulic Testing of the Lost Lake Aquifer Near Recovery Well RWM019

An aquifer pumping test was conducted on the Lost Lake Aquifer Zone (LLAZ) at the recently installed recovery well RWM019 in accordance with the approved test plan (Dixon, 2020). The objective of the testing was to determine baseline well performance parameters and aquifer hydraulic conductivity. This testing consisted of a step-drawdown test to determine well performance properties, a constant pumping rate aquifer test to determine aquifer hydraulic properties, and a post-test aquifer recovery monitoring period also used to estimate aquifer hydraulic properties. Well performance parameters determined included specific capacity, well efficiency, and head loss coefficients. The specific capacity of RWM019 was determined to be approximately 2.6 gpm/ft of drawdown based on the final step of the step-drawdown test. Well efficiency was inversely related to pumping rate and decreased from 87% to 81% over a pumping range of approximately 49 to 79 gpm. The aquifer head loss coefficient was determined to be 2.3 ft/ft 3 /min and the well loss coefficient was determined to be 0.05 min 2 /ft 5 .

42 ENGINEERING↗

The Geology of The Mt. Simon Sandstone Storage Complex at the Wabash #1 Well, Vigo Co., Indiana (Subtask 7.2, Technical Report)

The Wabash CarbonSAFE project drilled the Wabash #1 stratigraphic test well (ID# 168045) at the Wabash Valley Resources (WVR) IGCC facility in Vigo County, Indiana, to characterize and evaluate the basal Cambrian Mt. Simon Sandstone for commercial-scale CO 2 storage near the site. This report presents an extensive geologic characterization of the Mt. Simon storage complex and relevant data collected from the Wabash #1 well, such as lithologic data collected from cuttings and core, geophysical logging, geomechanical analysis of core samples, and well testing and fluid sampling within the Mt. Simon Sandstone. The Mt. Simon storage complex comprises two major sections: the Mt. Simon Sandstone as the potential reservoir and the overlying Eau Claire Formation as its primary seal. Within the report, an extensive depositional, sedimentological, and geochronologic characterization of the Mt. Simon is included with supportive chapters on the regional geology and the geophysical, petrophysical, and petrologic data collected during the project. An overview of 2D seismic reflection data collected from and around the test well is presented. Also presented are chapters on the characterization of the sealing Eau Claire Formation, including a chapter on the capacity of the primary and secondary seals to the Mt. Simon as well as a chapter on geomechanical testing results of the Eau Claire Formation and Mt. Simon Sandstone. Some of the information discussed in this report was used in the development of static and dynamic geologic models of the Mt. Simon Sandstone storage complex. The static and dynamic modeling of CO 2 injection in the Mt. Simon Sandstone are discussed in a separate report (Dessenberger et al., 2022) under the Wabash CarbonSAFE project.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cardiogenic oscillation phase relationships during single-breath tests performed in microgravity

We studied the phase relationships of the cardiogenic oscillations in the phase III portion of single-breath washouts (SBW) in normal gravity (1 G) and in sustained microgravity (microG). The SBW consisted of a vital capacity inspiration of 5% He-1.25% sulfurhexafluoride-balance O2, preceded at residual volume by a 150-ml Ar bolus. Pairs of gas signals, all of which still showed cardiogenic oscillations, were cross-correlated, and their phase difference was expressed as an angle. Phase relationships between inspired gases (e.g., He) and resident gas (n2) showed no change from 1 G (211 +/- 9 degrees) to microG (163 +/- 7 degrees). Ar bolus and He were unaltered between 1 G (173 +/- 15 degrees) and microG (211 +/- 25 degrees), showing that airway closure in microG remains in regions of high specific ventilation and suggesting that airway closure results from lung regions reaching low regional volume near residual volume. In contrast, CO2 reversed phase with He between 1 G (332 +/- 6 degrees) and microG (263 +/- 27 degrees), strongly suggesting that, in microG, areas of high ventilation are associated with high ventilation-perfusion ratio (VA/Q). This widening of the range of VA/Q in microG may explain previous measurements (G.K. Prisk, A.R. Elliott, H.J.B. Guy, J.M. Kosonen, and J.B. West J. Appl. Physiol. 79: 1290-1298, 1995) of an overall unaltered range of VA/Q in microG, despite more homogeneous distributions of both ventilation and perfusion.

Non-NASA Center↗

Pilot Workload Rating Predictions Using Image Data and Recurrent Neural Networks

In this work, we augmented existing methods for estimating pilot workload ratings with deep neural networks trained using data from simulated flight tests in the Vertical Motion Simulator (VMS). We used an existing method, Spare Capacity Operations Estimator (SCOPE), along with a recurrent neural network and conducted comparison studies between the two methods individually, and when used together. We found that using both methods together can improve the result over using either approach alone. In our first test case, we achieved an improved linear correlation coefficient of 0.409 over that of SCOPE alone at 0.352 on the training dataset. Through cross validation, we also found that the results may be dependent on the split of training vs. validation data, and that further investigation should be conducted to understand what additional inputs to the neural network model should be made.

Image Data↗

Variable area radial turbine fabrication and test program

A variable area radial turbine with a moveable nozzle sidewall was experimentally evaluated. The turbine was designed for an advanced variable capacity gas turbine rotorcraft engine. The turbine has a mass flow rate of 2.27 kg/sec (5.0 lbs/sec), and a rotor inlet temperature of 1477K (2200 F). Testing was conducted at a reduced inlet temperature, but the aerodynamic parameters and Reynolds numbers were duplicated. Overall performance was obtained for a range of nozzle areas from 50% to 100% of the maximum area. The test program determined the effect on performance of: (1) Moving the hub or shroud sidewall; (2) Sidewall-vane clearance leakage; (3) Vaneless space geometry change; and (4) Nozzle cooling flows. Data were obtained for a range of pressure ratios and speeds and are presented in a number of performance maps.

Rogo, C.↗

Development of Engineered Metal-Organic Framework (MOF) materials for perfluorooctane sulfonate (PFOS) Remediation

In this project, an engineered form of a Metal-Organic Framework (MOF) based material is developed for the removal of perfluorooctane sulfonate (PFOS) for real-world applications. The powdered MOF material has been demonstrated at the Pacific Northwest National Laboratory (PNNL) to selectively capture PFOS from distilled (DI) water with a large performance advantage over granulated activated carbon (GAC). In this project, the powdered material was transformed into an engineered form (using a polymer) to demonstrate PFOS adsorption capacity in tap water. PNNL developed and processed the MOF material in the engineering form (granules). After thorough characterization and stability testing, these engineered MOF granules were provided to an industrial collaborator, AVANTech, LLC, for testing and demonstration of continuous, long-term PFOS removal from tap water. The preliminary results showed PFOS sorption capacities at parts per billion (ppb) concentrations in tap water under a flow system. Also provided insight into sorbent-based material utilization in a continuous flow system. Further studies are required to optimize and understand sorption in such industrial-scale applications.

36 MATERIALS SCIENCE↗

Review of thermophysical property methods applied to fueled and un-fueled molten salts

Recent investigation into designs of molten salt reactors (MSR) requires accurate data of candidate salts. Review of the literature shows lacking thermophysical (TP) property data for coolants and fuel-bearing salts of Advanced High Temperature Reactors (AHTR). Measurement uncertainties of current data are even more deficient, and this affects ongoing research where MSR modeling and testing are being performed. Melting temperature, viscosity, density, specific heat capacity, and thermal and electrical conductivity measurements are often not arranged together or discussed in great detail, especially for fuel-bearing salts. Raw data from key findings spanning over 70 years for LiF, LiF-BeF 2 , LiF-NaF-KF, KCl-MgCl 2 , KF-ZrF 4 , and NaF-KF-MgF 2 have been organized and presented here. Brief description of methods used to obtain these results, in addition to the TP data of some of these salts as fuel carriers, has also been discussed. Thermal conductivity data are particularly weak due to older, high-error measurement techniques. More recent measurement systems to evaluate salt thermal conductivity show promise for obtaining consistent absolute values. This work concludes that measurement systems such as transient hot-wire method, forced Rayleigh scattering, and laser flash analysis provide the most promise to fill these data gaps and reduce current uncertainty in thermal conductivity measurements of both fueled and un-fueled molten salts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Internal short circuit and failure mechanisms of lithium-ion pouch cells under mechanical indentation abuse conditions: An experimental study

Electromechanical structural integrity and thermal stability dictate the safety performance of lithium-ion batteries. Progressive deformation and failure across microscopic and macroscopic lengths scales that are responsible for internal short circuit (ISC) in lithium-ion cells under mechanical abuse conditions remains elusive. In this study, a series of indentation tests were conducted on lithium-ion cells with different capacities up to the occurrence of ISC. The external response and internal configuration of these cells were investigated. It is discovered that cells with different capacities and state of charges exhibited different behaviors. Maximum temperature, which is often regarded as the most important parameter related to thermal runaway (TR), varied considerably due to the complicated contact configurations. X-ray computed tomography (XCT) showed that ISC was a collective result of shear band or other strain-localization modes in the electrode assembly, shear offsets in the granular coatings of electrodes, and the accompanying ductile fracture in the metal foils. We believe that the irregular strain-localization modes (kinks, cusps, and buckles), radical mismatches in mechanical properties of different layers, and geometric features of the indenter eventually lead to the tearing/puncture of cell separator at various locations. Furthermore, the results could provide useful guidance for the micromechanical modeling of lithium-ion cells.

25 ENERGY STORAGE↗

Impact of Synthetic Parameters on Structure and Electrochemistry of High-Entropy Layered Oxide LiNi 0.2 Co 0.2 Mn 0.2 Al 0.2 Fe 0.2 O 2

Here, this study explored a high-entropy layered oxide (HELO), LiNi 0.2 Co 0.2 Mn 0.2 Al 0.2 Fe 0.2 O 2 , prepared by coprecipitation followed by heat treatment. Coprecipitation yielded a kinetically favored product, and the subsequent heat treatment under various temperatures and times allowed tuning the material toward more thermodynamically favored structures. Refinement of X-ray powder diffraction (XRD) revealed that after 450 °C treatment, ~12% of the Ni 2+ in the structure was located within the lithium cation layer. After heat treatment at 600, 700, and 800 °C, there was a continued decrease of Ni 2+ in the lithium cation layer to 9.3, 6.3, and 3.7%, respectively. Longer heat treatment times at 800 °C decreased the level to 2.5%. Electrochemical behavior was evaluated by cyclic voltammetry, galvanostatic cycling, rate capability testing, and electrochemical impedance spectroscopy, where increased loaded voltage, functional capacity, rate capability, and decreased impedance were observed for samples treated at higher temperatures with lower cation mixing. X-ray absorption near edge spectroscopy (XANES) data indicated that the redox activity of Ni and Co was dominant in the electrochemistry, while the participation of Mn or Fe was minimal. The level of Ni oxidation state change between charge and discharge related to the heat treatment temperature where the samples with high cation mixing showed lower capacity consistent with some Ni 3+ in the transition metal layer inaccessible for electron transfer. Longer heat treatment times at 800 °C did not continue to provide a benefit in electrochemical function even with some additional reduction in cation mixing.

25 ENERGY STORAGE↗

Multi-metallic conduction cooled superconducting radio-frequency cavity with high thermal stability

Superconducting radio-frequency cavities are commonly used in modern particle accelerators for applied and fundamental research. Such cavities are typically made of high-purity, bulk Nb and with cooling by a liquid helium bath at a temperature of ~2 K. The size, cost and complexity of operating a particle accelerator with a liquid helium refrigerator make the current cavity technology not favorable for use in industrial-type accelerators. We have developed a multi-metallic 1.495 GHz elliptical cavity conductively cooled by a cryocooler. The cavity has a ~2 µm thick layer of Nb 3 Sn on the inner surface, exposed to the rf field, deposited on a ~3 mm thick bulk Nb shell and a bulk Cu shell, of thickness $\geqslant\! 5$ mm deposited on the outer surface by electroplating. A bolt-on Cu plate 1.27 cm thick was used to thermally connect the cavity equator to the second stage of a Gifford-McMahon cryocooler with a nominal capacity of 2 W at 4.2 K. The cavity was tested initially in liquid helium at 4.3 K and reached a peak surface magnetic field of ~36 mT with a quality factor of 2 × 10 9 . The cavity cooled by the cryocooler achieved a peak surface magnetic field of ~29 mT, equivalent to an accelerating gradient of 6.5 MV m –1 . The conduction-cooled cavity could be operated in continuous-wave with as high as 5 W dissipation in the cavity for 1 h without any thermal breakdown, because of the Cu outer layer with high thermal conductivity. This result represents a paradigm shift in the technology of superconducting accelerator cavities.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantum chemically calculated Abraham parameters for quantifying and predicting polymer hydrophobicity

The leakage and accumulation of plastic in the environment is a significant and growing problem with numerous detrimental impacts and has led to a push toward the design and development of more environmentally benign materials. To this end, we have developed a quantum chemistry-based model for predicting the mobility of polymer materials from molecular structure. Hydrophobicity is used as a surrogate for mobility given that hydrophobic interactions drive much of the partitioning of contaminants in and out of various environmentally relevant compartments. To model polymer hydrophobicity, we adjusted a previously developed Quantum Chemically Calculated Abraham Parameter model to calculate Abraham parameters of small molecules from molecular structure information. The resulting model predicted the octanol-water partition coefficient (K OW ) of polymer repeating units with a root mean square error (RMSE) of 0.48 (log scale). Additionally, the hydrophobicity of high molecular weight polymer materials was captured through solubility parameters and Nile red staining experiments from the literature and predicted with RMSEs of 1.21 (J/cc) 0.5 and 3.42 nm, respectively. Finally, to test the environmental applicability of the model, the relative adsorption capacity of three polymers was predicted and used to unify sorption isotherms across multiple sorbates and polymer sorbents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Trimer Quinoxalines as Organic Cathode Materials for Lithium-Ion Batteries

Due to synthetic ease, high redox potentials, low solubility in polar electrolytes, and good electric conductivity of their semiconducting crystals, discotic quinoxaline trimers (3Q) have been considered as possible candidates for 4 V organic cathodes in lithium-ion batteries. To assess their feasibility as such materials, several 3Q derivatives have been synthesized and tested in half-cells. In voltage limited cycling tests at 1.2–3.9 V vs Li/Li + , the specific discharge capacities of 40–180 mAh g -1 were obtained at a rate of 1 C, and multiple lithiation of 3Q and its derivatives was observed during discharge. However, the obtained discharge capacity was only a fraction of the theoretical capacity expected for reversible six-electron reduction; there was also rapid capacity fade. Our spectroscopic studies indicate the reversible three-electron lithiation at 2 V vs Li/Li + , but suggest instability of more highly discharged states. Finally, our conclusion is that while the 3Q derivatives combine several traits that are desirable in an organic cathode material (including negligible solubility, capacity for multiple charging, and near-100% coulombic efficiency), these materials are still impractical to use.

25 ENERGY STORAGE↗