Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calculation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

SU-F-T-428: An Optimization-Based Commissioning Tool for Finite Size Pencil Beam Dose Calculations

Purpose: Finite size pencil beam (FSPB) algorithms are commonly used to pre-calculate the beamlet dose distribution for IMRT treatment planning. FSPB commissioning, which usually requires fine tuning of the FSPB kernel parameters, is crucial to the dose calculation accuracy and hence the plan quality. Yet due to the large number of beamlets, FSPB commissioning could be very tedious. This abstract reports an optimization-based FSPB commissioning tool we have developed in MatLab to facilitate the commissioning. Methods: A FSPB dose kernel generally contains two types of parameters: the profile parameters determining the dose kernel shape, and a 2D scaling factors accounting for the longitudinal and off-axis corrections. The former were fitted using the penumbra of a reference broad beam’s dose profile with Levenberg-Marquardt algorithm. Since the dose distribution of a broad beam is simply a linear superposition of the dose kernel of each beamlet calculated with the fitted profile parameters and scaled using the scaling factors, these factors could be determined by solving an optimization problem which minimizes the discrepancies between the calculated dose of broad beams and the reference dose. Results: We have commissioned a FSPB algorithm for three linac photon beams (6MV, 15MV and 6MVFFF). Dose of four field sizes (6*6cm2, 10*10cm2, 15*15cm2 and 20*20cm2) were calculated and compared with the reference dose exported from Eclipse TPS system. For depth dose curves, the differences are less than 1% of maximum dose after maximum dose depth for most cases. For lateral dose profiles, the differences are less than 2% of central dose at inner-beam regions. The differences of the output factors are within 1% for all the three beams. Conclusion: We have developed an optimization-based commissioning tool for FSPB algorithms to facilitate the commissioning, providing sufficient accuracy of beamlet dose calculation for IMRT optimization.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-600: Influence of Acuros XB and AAA Dose Calculation Algorithms On Plan Quality Metrics and Normal Lung Doses in Lung SBRT

Purpose: To study the influence of superposition-beam model (AAA) and determinant-photon transport-solver (Acuros XB) dose calculation algorithms on the treatment plan quality metrics and on normal lung dose in Lung SBRT. Methods: Treatment plans of 10 Lung SBRT patients were randomly selected. Patients were prescribed to a total dose of 50-54Gy in 3–5 fractions (10?5 or 18?3). Doses were optimized accomplished with 6-MV using 2-arcs (VMAT). Doses were calculated using AAA algorithm with heterogeneity correction. For each plan, plan quality metrics in the categories- coverage, homogeneity, conformity and gradient were quantified. Repeat dosimetry for these AAA treatment plans was performed using AXB algorithm with heterogeneity correction for same beam and MU parameters. Plan quality metrics were again evaluated and compared with AAA plan metrics. For normal lung dose, V{sub 20} and V{sub 5} to (Total lung- GTV) were evaluated. Results: The results are summarized in Supplemental Table 1. PTV volume was mean 11.4 (±3.3) cm{sup 3}. Comparing RTOG 0813 protocol criteria for conformality, AXB plans yielded on average, similar PITV ratio (individual PITV ratio differences varied from −9 to +15%), reduced target coverage (−1.6%) and increased R50% (+2.6%). Comparing normal lung doses, the lung V{sub 20} (+3.1%) and V{sub 5} (+1.5%) were slightly higher for AXB plans compared to AAA plans. High-dose spillage ((V105%PD - PTV)/ PTV) was slightly lower for AXB plans but the % low dose spillage (D2cm) was similar between the two calculation algorithms. Conclusion: AAA algorithm overestimates lung target dose. Routinely adapting to AXB for dose calculations in Lung SBRT planning may improve dose calculation accuracy, as AXB based calculations have been shown to be closer to Monte Carlo based dose predictions in accuracy and with relatively faster computational time. For clinical practice, revisiting dose-fractionation in Lung SBRT to correct for dose overestimates attributable to algorithm may very well be warranted.

60 APPLIED LIFE SCIENCES↗

SU-F-T-667: Development and Validation of Dose Calculation for An Open-Source KV Treatment Planning System for Small Animal Radiotherapy

Purpose: An open-source, convolution/superposition based kV-treatment planning system(TPS) was developed for small animal radiotherapy from previously existed in-house MV-TPS. It is flexible and applicable to both step and shoot and helical tomotherapy treatment delivery. For initial commissioning process, the dose calculation from kV-TPS was compared with measurements and Monte Carlo(MC) simulations. Methods: High resolution, low energy kernels were simulated using EGSnrc user code EDKnrc, which was used as an input in kV-TPS together with MC-simulated x-ray beam spectrum. The Blue Water™ homogeneous phantom (with film inserts) and heterogeneous phantom (with film and TLD inserts) were fabricated. Phantom was placed at 100cm SSD, and was irradiated with 250 kVp beam for 10mins with 1.1cm × 1.1cm open field (at 100cm) created by newly designed binary micro-MLC assembly positioned at 90cm SSD. Gafchromic™ EBT3 film was calibrated in-phantom following AAPM TG-61 guidelines, and were used for measurement at 5 different depths in phantom. Calibrated TLD-100s were obtained from ADCL. EGS and MNCP5 simulation were used to model experimental irradiation set up calculation of dose in phantom. Results: Using the homogeneous phantom, dose difference between film and kV-TPS was calculated: mean(x)=0.9%; maximum difference(MD)=3.1%; standard deviation(σ)=1.1%. Dose difference between MCNP5 and kV-TPS was: x=1.5%; MD=4.6%; σ=1.9%. Dose difference between EGS and kV-TPS was: x=0.8%; MD=1.9%; σ=0.8%. Using the heterogeneous phantom, dose difference between film and kV-TPS was: x=2.6%; MD=3%; σ=1.1%; and dose difference between TLD and kV-TPS was: x=2.9%; MD=6.4%; σ=2.5%. Conclusion: The inhouse, open-source kV-TPS dose calculation system was comparable within 5% of measurements and MC simulations in both homogeneous and heterogeneous phantoms. The dose calculation system of the kV-TPS is validated as a part of initial commissioning process for small animal radiotherapy. The kV-TPS has the potential for accurate dose calculation for any kV treatment or imaging modalities.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-JeP1-05: Water Equivalent Path Length Calculations Using Scatter-Corrected Head and Neck CBCT Images to Evaluate Patients for Adaptive Proton Therapy

Purpose: To establish a method to evaluate the dosimetric impact of anatomic changes in head and neck patients during proton therapy by using scatter-corrected cone-beam CT (CBCT) images. Methods: The water equivalent path length (WEPL) was calculated to the distal edge of PTV contours by using tomographic images available for six head and neck patients received photon therapy. The proton range variation was measured by calculating the difference between the distal WEPLs calculated with the planning CT and weekly treatment CBCT images. By performing an automatic rigid registration, six degrees-of-freedom (DOF) correction was made to the CBCT images to account for the patient setup uncertainty. For accurate WEPL calculations, an existing CBCT scatter correction algorithm, whose performance was already proven for phantom images, was calibrated for head and neck patient images. Specifically, two different image similarity measures, mutual information (MI) and mean square error (MSE), were tested for the deformable image registration (DIR) in the CBCT scatter correction algorithm. Results: The impact of weight loss was reflected in the distal WEPL differences with the aid of the automatic rigid registration reducing the influence of patient setup uncertainty on the WEPL calculation results. The WEPL difference averaged over distal area was 2.9 ± 2.9 (mm) across all fractions of six patients and its maximum, mostly found at the last available fraction, was 6.2 ± 3.4 (mm). The MSE-based DIR successfully registered each treatment CBCT image to the planning CT image. On the other hand, the MI-based DIR deformed the skin voxels in the planning CT image to the immobilization mask in the treatment CBCT image, most of which was cropped out of the planning CT image. Conclusion: The dosimetric impact of anatomic changes was evaluated by calculating the distal WEPL difference with the existing scatter-correction algorithm appropriately calibrated. Jihun Kim, Yang-Kyun Park, Gregory Sharp, and Brian Winey have received grant support from the NCI Federal Share of program income earned by Massachusetts General Hospital on C06 CA059267, Proton Therapy Research and Treatment Center.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRC-12: Optimized Parallel MonteCarlo Dose Calculations for Secondary MU Checks

Purpose: Secondary MU checks are an important tool used during a physics review of a treatment plan. Commercial software packages offer varying degrees of theoretical dose calculation accuracy, depending on the modality involved. Dose calculations of VMAT plans are especially prone to error due to the large approximations involved. Monte Carlo (MC) methods are not commonly used due to their long run times. We investigated two methods to increase the computational efficiency of MC dose simulations with the BEAMnrc code. Distributed computing resources, along with optimized code compilation, will allow for accurate and efficient VMAT dose calculations. Methods: The BEAMnrc package was installed on a high performance computing cluster accessible to our clinic. MATLAB and PYTHON scripts were developed to convert a clinical VMAT DICOM plan into BEAMnrc input files. The BEAMnrc installation was optimized by running the VMAT simulations through profiling tools which indicated the behavior of the constituent routines in the code, e.g. the bremsstrahlung splitting routine, and the specified random number generator. This information aided in determining the most efficient compiling parallel configuration for the specific CPU’s available on our cluster, resulting in the fastest VMAT simulation times. Our method was evaluated with calculations involving 10{sup 8} – 10{sup 9} particle histories which are sufficient to verify patient dose using VMAT. Results: Parallelization allowed the calculation of patient dose on the order of 10 – 15 hours with 100 parallel jobs. Due to the compiler optimization process, further speed increases of 23% were achieved when compared with the open-source compiler BEAMnrc packages. Conclusion: Analysis of the BEAMnrc code allowed us to optimize the compiler configuration for VMAT dose calculations. In future work, the optimized MC code, in conjunction with the parallel processing capabilities of BEAMnrc, will be applied to provide accurate and efficient secondary MU checks.

60 APPLIED LIFE SCIENCES↗

WE-DE-201-06: Impact of Temporal Image Coregistration Methods On 3D Internal Dose Calculations in Targeted Radionuclide Therapy

Purpose: The calculation of 3D internal dose calculations in targeted radionuclide therapy requires the acquisition and temporal coregistration of a serial PET/CT or SPECT/CT images. This work investigates the dosimetric impact of different temporal coregistration methods commonly used for 3D internal dosimetry. Methods: PET/CT images of four mice were acquired at 1, 24, 48, 72, 96, 144 hrs post-injection of {sup 124}I-CLR1404. The therapeutic {sup 131}I-CLR1404 absorbed dose rate (ADR) was calculated at each time point using a Geant4-based MC dosimetry platform using three temporal image coregistration Methods: (1) no coregistration (NC), whole body sequential CT-CT affine coregistration (WBAC), and individual sequential ROI-ROI affine coregistration (IRAC). For NC, only the ROI mean ADR was integrated to obtain ROI mean doses. For WBAC, the CT at each time point was coregistered to a single reference CT. The CT transformations were applied to the corresponding ADR images and the dose was calculated on a voxel-basis within the whole CT volume. For IRAC, each individual ROI was isolated and sequentially coregistered to a single reference ROI. The ROI transformations were applied to the corresponding ADR images and the dose was calculated on a voxel-basis within the ROI volumes. Results: The percent differences in the ROI mean doses were as large as 109%, 88%, and 32%, comparing the WBAC vs. IRAC, NC vs. IRAC, and NC vs. WBAC methods, respectively. The CoV in the mean dose between the all three methods ranged from 2–36%. The pronounced curvature of the spinal cord was not adequately coregistered using WBAC which resulted in large difference between the WBAC and IRAC. Conclusion: The method used for temporal image coregistration can result in large differences in 3D internal dosimetry calculations. Care must be taken to choose the most appropriate method depending on the imaging conditions, clinical site, and specific application. This work is partially funded by NIH Grant R21 CA198392-01.

60 APPLIED LIFE SCIENCES↗

Electrodynamic Calculation of Effective Electromagnetic Parameters of a Dielectric Medium with Metallic Nanoparticles of a Given Size

The frequency dependence of the effective complex permittivity and effective complex permeability of a heterostructure based on a dielectric medium containing metallic nanoparticles of spherical shape is calculated by an original method. In contrast to the Bruggeman [21] and the Maxwell Garnett [17] approaches, which use the quasi-static approximation in calculations, a nonuniform distribution of electromagnetic fields inside metallic particles is calculated, which allows the analysis of the electromagnetic parameters of the heterostructure not only as a function of frequency but also as a function of the nanoparticle size. It is shown that the plasmon resonant frequency decreases with increasing both the size and the concentration of particles in the heterostructure. It is also shown that a dielectric medium containing nonmagnetic metallic nanoparticles exhibits diamagnetic properties. In this case, the position of the maximum on the frequency dependence of the imaginary part of the magnetic susceptibility coincides with the relaxation frequency of charge carriers. The calculated spectra of the real and imaginary components of the permittivity of the heterostructure with a size of metallic particles less than 10 nm are in good agreement with Bruggeman calculations; however, the agreement with Maxwell Garnett calculations is observed only at nanoparticle concentrations lower than 10{sup –6}.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Fine-grid calculations for stellar electron and positron capture rates on Fe isotopes

The acquisition of precise and reliable nuclear data is a prerequisite to success for stellar evolution and nucleosynthesis studies. Core-collapse simulators find it challenging to generate an explosion from the collapse of the core of massive stars. It is believed that a better understanding of the microphysics of core-collapse can lead to successful results. The weak interaction processes are able to trigger the collapse and control the lepton-to-baryon ratio (Y{sub e}) of the corematerial. It is suggested that the temporal variation of Y{sub e} within the core of a massive star has a pivotal role to play in the stellar evolution and a fine-tuning of this parameter at various stages of presupernova evolution is the key to generate an explosion. During the presupernova evolution of massive stars, isotopes of iron, mainly {sup 54-56}Fe, are considered to be key players in controlling Y{sub e} ratio via electron capture on these nuclides. Recently an improved microscopic calculation of weak-interaction-mediated rates for iron isotopes was introduced using the proton-neutron quasiparticle random-phase-approximation (pn-QRPA) theory. The pn-QRPA theory allows a microscopic state-by-state calculation of stellar capture rates which greatly increases the reliability of calculated rates. The results were suggestive of some fine-tuning of the Y{sub e} ratio during various phases of stellar evolution. Here we present for the first time the fine-grid calculation of the electron and positron capture rates on {sup 54-56}Fe. The sensitivity of the pn-QRPA calculated capture rates to the deformation parameter is also studied in this work. Core-collapse simulators may find this calculation suitable for interpolation purposes and for necessary incorporation in the stellar evolution codes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spectral Efficiency and Tandem Performance Calculators [SWR-24-92]

The Spectral Efficiency and Tandem Performance Calculators allow users to test material types for use in tandem photovoltaic devices to better understand if a given material could work well. The Spectral Efficiency (SE) calculator takes a set of current vs voltage (I-V) and quantum efficiency (QE) data along with a spectrum input and plots the spectral efficiency of the cells represented by the datasets for the spectrum provided. The Tandem Performance calculator uses the calculated spectral efficiency of top and bottom cells and the transmission data of the top cell to calculate performance metrics for a tandem device in either a two or four terminal architecture. The SE and Tandem Performance calculators are based on the following publication: Yu, Z., Leilaeioun, M. & Holman, Z. Selecting tandem partners for silicon solar cells. Nat Energy 1, 16137 (2016).

Warren, Emily↗

Revisiting the Hail Radar Reflectivity–Kinetic Energy Flux Relation by Combining T-Matrix and Discrete Dipole Approximation Calculations to Size Distribution Observations

The retrieval of hail kinetic energy with weather radars or its simulation in numerical models is challenging because of the shape complexity and variable density of hailstones. We combine 3D scans of individual hailstones with measurements of the particle size distributions (PSD) and T-matrix calculations to understand how hail reflectivity Z changes when approximating hailstones as spheroids, as compared to the realistic shapes obtained by 3D scanning technology. Additionally, recent terminal velocity relations are used to compare Z to the hail kinetic energy flux E ˙ . We parameterize the hail backscattering cross sections at L, S, C, and X bands as a function of size between 0.5 and 5.0 cm, matching the range of the observed PSDs. The scattering calculations use the T-matrix method for size parameters below 1.0 and the discrete dipole approximation (DDA) method otherwise. The DDA calculations are done for 48 digital models of realistic hailstones of sizes between 1 and 5 cm. The DDA cross sections are calculated for multiple orientations and averaged assuming a fully random orientation distribution to provide a single value per hailstone. The T-matrix reflectivity assuming solid ice spheres presents negligible differences to DDA results for size parameters below 1.0. Therefore, T matrix was used to fill in the gaps left by the DDA calculations. The results are mapped to the same size bins of the observed PSDs, allowing the calculation of the radar reflectivity. This is then correlated to E ˙ , allowing a potential improvement of past retrieval methods of E ˙ from Z in multiple wavelengths.

54 ENVIRONMENTAL SCIENCES↗

GDB-9-Ex_EOM-CCSD: Dataset containing Equation of Motion Coupled Cluster (EOM-CCSD) calculations for organic molecules of the GDB-9-Ex dataset.

This dataset contains data-intensive quantum chemical electronic structure calculations for 80,593 organic molecules of the GDB-9-Ex dataset. Calculations were performed using the Equation of Motion Coupled Cluster (EOM-CCSD) first principles method using the ORCA software. It provides UV-vis spectra calculations of molecules with a high level of accuracy. The optical spectra behavior was collected based on the optimized molecular geometries in the DFTB method with 3ob parameters. All calculations utilized the def2-TZVP basis sets with the auxiliary def2/J and def2-TZVP/C basis sets. The similarity-transformed EOM-CCSD method that used domain-based local pair natural orbitals (DLPNO) approximation which constitutes the STEOM-DLPNO-CCSD method was used. This method is based on the STEOM approach and was found to make accurate predictions of transition energies for organic molecules. For the excitation energy calculations, the lowest 50 excitation states were calculated.

AI dataset↗

GDB-9-Ex_TD-DFT-PBE0: Dataset containing Time Dependent Density Functional Theory (TDDFT) calculations for organic molecules of the GDB-9-Ex dataset.

This dataset contains data-intensive quantum chemical electronic structure calculations for 96,766 organic molecules of the GDB-9-Ex dataset. Calculations were performed using the Time Dependent Density Functional Theory (TDDFT) first principles method using the ORCA software. It provides UV-vis spectra calculations of molecules with a high level of accuracy. The optical spectra behavior was collected based on the optimized molecular geometries in the DFTB method with 3ob parameters. All calculations utilized the def2-TZVP basis sets with the auxiliary def2/J and def2-TZVP/C basis sets. The time-dependent density-functional theory (TDDFT) approach with the PBE0 exchange-correlation functional and ORCAs default integration grid was employed. For the excitation energy calculations, the lowest 50 excitation states were calculated.

AI dataset↗

Unsaturated and Saturated Hydraulic Parameters of Soils at the East River Watershed, Colorado Calculated using the Pedotransfer Function Method.

The purpose of the data package is to present the results of calculations of the following unsaturated-saturated hydraulic parameters of soils of the East River Watershed, Colorado: fully saturated water content (Qs), residual saturation (Qr), van genuchten parameters alpha and n, field capacity (FC), and saturated hydraulic conductivity (Ks). Calculations were conducted for the following soil texture types: sandy_loam, loam, silty_clay_loam, clay_loam, silt loam; the particle size distribution included the percentage of sand, silt, clay, and the bulk density (BD) of soils. Calculations were conducted for the following areas- Lower_Subalpine (6 samples),- Lower_Montane_lower_hillslope (7 samples),- Floodplain_at_base_of_lower_montane_hillslope, (11 samples),- PLM-0 (10 samples),- PLM-1 (10 samples), and - PLM-3 (13 samples)Calculations were conducted using the Pedotransfer Function Method developed by Tóth et al. (2014) with the application of the code ”euptf” in Rstudio. The data are being summarized in the Excel file ”Unsaturated_Saturated_Hydraulic_Parameters_PTF_calculated_EASt_EIver.xls" including two worksheets:“full_data_EAST_RIVER” which includes (a) the input data used for calculations, the soil texture triangle, and the plots of the water retention curves and unsaturated hydraulic conductivity for several types of soil texture, and (b) the summary table with the averaged parameters for each area. The the texture triangle was plotted using the Rstudio "soiltexture." Microsoft Excel software is required to open the Excel file. The metadata and a list of references to the Rstudio libraries used for calculations and data visualization are giving in the Word Readme file.

54 ENVIRONMENTAL SCIENCES↗

R&D GREET Battery Carbon Footprint Calculator

The Battery Carbon Footprint (CF) Calculator was developed to help U.S. battery manufacturers meet the carbon footprint reporting requirements of the EU Battery Regulation (EU) 2023/1542. The calculator incorporates several major battery carbon footprint frameworks, including the Joint Research Centre's Rules for the Calculation of the Carbon Footprint of Electric Vehicle Batteries (CFB-EV), RECHARGE's Product Environmental Footprint Category Rules for High Specific Energy Rechargeable Batteries for Mobile Applications (PEFCR), the Catena-X Product Carbon Footprint Rulebook (CX-PCF Rules), Battery Pass's Battery Carbon Footprint: Rules for Calculating the Carbon Footprint of the "Distribution" and "End-of-Life and Recycling" Life Cycle Stages, the Global Battery Alliance's Greenhouse Gas Rulebook: Generic Rules, Version 2.1, and the Ministry of Economy, Trade and Industry's draft Carbon Footprint Calculation Method for Automotive Batteries. The tool pairs these frameworks with foreground data from Argonne's R&D GREET models and integrates user-supplied background data covering battery manufacturing and supply chain activities. By bringing multiple international methodologies together in a single platform, the calculator enables manufacturers to evaluate product carbon footprints, improve data consistency, and prepare for evolving regulatory compliance and global market reporting requirements.

Zhang, Jingyi↗

Equilipy: a python package for calculating phase equilibria

The CALPHAD (CALculation of PHAse Diagram) approach (Nigel Saunders & Miodownik, 1998) provides predictions for thermodynamically stable phases in multicomponent-multiphase materials across a wide range of temperatures. Consequently, the CALPHAD calculations became an essential tool in materials and process design (Luo, 2015). Such design tasks frequently require navigating a high-dimensional space due to multiple components involved in the system. This increasing complexity demands high-throughput CALPHAD calculations, especially in the rapidly evolving field of alloy design. In response to the need, we developed Equilipy an open-source Python package designed for calculating phase equilibria of multicomponent-multiphase systems. Equilipy is specifically tailored for high-throughput CALPHAD calculations, offering parallel computations across multiple processors and nodes with the given NPT input conditions namely elemental compositions (N), pressure (P), and temperature (T). Equilipy utilizes the program structure and Gibbs energy functions from the Fortran-based program, Thermochimica (Piro et al., 2013), with incorporating a new Gibbs energy minimization algorithm. This algorithm, originally developed by Capitani and Brown in 1987 (Capitani & Brown, 1987), has been revised and implemented to enhance the stability and performance of calculations. The Fortran codes are precompiled and interfaced with Python via F2PY, ensuring high computation speed. Benchmark tests shown in Figure 1 demonstrate that Equilipy’s computation speed is comparable to those of established commercial software, TC-Python and PanPython. This result highlights its efficiency and potential applications in various scientific and industrial fields.

97 MATHEMATICS AND COMPUTING↗

Graphical User Interface for Simplified Neutron Transport Calculations

A number of codes perform simple photon physics calculations. The nuclear industry is lacking in similar tools to perform simplified neutron physics shielding calculations. With the increased importance of performing neutron calculations for homeland security applications and defense nuclear nonproliferation tasks, having an efficient method for performing simple neutron transport calculations becomes increasingly important. Codes such as Monte Carlo N-particle (MCNP) can perform the transport calculations; however, the technical details in setting up, running, and interpreting the required simulations are quite complex and typically go beyond the abilities of most users who need a simple answer to a neutron transport calculation. The work documented in this report resulted in the development of the NucWiz program, which can create an MCNP input file for a set of simple geometries, source, and detector configurations. The user selects source, shield, and tally configurations from a set of pre-defined lists, and the software creates a complete MCNP input file that can be optionally run and the results viewed inside NucWiz.

61 RADIATION PROTECTION AND DOSIMETRY↗

Microscopic calculation of fission fragment energies for the 239 Pu( n th ,f ) reaction

We calculate the total kinetic and excitation energies of fragments produced in the thermal-induced fission of 239 Pu. This result is a proof-of-principle demonstration for a microscopic approach to the calculation of fission-fragment observables for applied data needs. In addition, the calculations highlight the application of a fully quantum mechanical description of scission, and the importance of exploring scission configurations as a function of the moments of the fragments, rather than through global constraints on the moments of the fissioning nucleus. Using a static microscopic calculation of configurations at and near scission, we have identified fission fragments for the 239 Pu ( n th ,f ) reaction and extracted their total kinetic and excitation energies. Comparison with data shows very good overall agreement between theory and experiment. Beyond their success as a proof of principle, these calculations also highlight the importance of local constraints on the fragments themselves in microscopic calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Calculation of Ambient (H*(10)) and Personal (H p (10)) Dose Equivalent from a 252 Cf Neutron Source

The neutron emission rate from radioisotope neutron sources such as 252 Cf sources can be calibrated by the National Institute of Standards and Technology (NIST) by the manganous sulfite bath method. This calibration method does not compute the dose or dose equivalent rate from the source. Because there is no accepted transfer standard for neutron dose measurements, secondary calibration facilities are responsible for determining their own neutron dose factors. This report describes a neutron source and irradiation apparatus in use at the Pacific Northwest National Laboratory Calibration Facility. The neutron source is a SR-Cf-3000 design 252 Cf neutron source. The neutron source is contained in an aluminum transfer capsule that is used to transport the neutron source between its storage location and it’s irradiation location. During irradiations, the source is located in a transfer tube assembly that consists of two concentric aluminum tubes. When moderated neutrons are desired, the transfer tube assembly is surrounded by a sphere that is filled with D 2 O as a moderating medium. Ambient dose equivalent (H*(10)) and Personal dose equivalent (H p (10)) dose rates and dose conversion factors were calculated for moderated and unmoderated neutron spectra based on the data provided in ICRP Publication 74. The neutron fluence-to-dose-equivalent conversion factors calculated for this report are summarized and compared to published values in Table 47. The calculated coefficients for the unmoderated 252 Cf spectra agree very well with published reference values, within about 2%. The calculated coefficients for the D 2 O moderated 252 Cf spectra, however, differ from published reference values by about 22%. The PNNL coefficients are higher than the published values which could be interpreted to mean that the PNNL D 2 O moderated spectrum is harder, i.e. higher average energy, than the spectrum published by the ISO (2000), which formed the basis for the published coefficients. The D 2 O moderating sphere in use at PNNL contains less D 2 O moderator than did the D 2 O moderating sphere that was used to calculate the ISO spectrum and this is the likely reason for much of the spectral differences. The exact location of the 252 Cf activity in the source encapsulation is unknown. Preliminary measurements, not described in this report, indicate that the activity may be offset from the location that has been assumed in the past. Corrections for the offset are being proposed and will be the subject of another report. This report was written in a calculation package format to help meet various Quality Assurance requirements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗