Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “buildings efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

De novo protein design of photochemical reaction centers

Abstract Natural photosynthetic protein complexes capture sunlight to power the energetic catalysis that supports life on Earth. Yet these natural protein structures carry an evolutionary legacy of complexity and fragility that encumbers protein reengineering efforts and obfuscates the underlying design rules for light-driven charge separation. De novo development of a simplified photosynthetic reaction center protein can clarify practical engineering principles needed to build new enzymes for efficient solar-to-fuel energy conversion. Here, we report the rational design, X-ray crystal structure, and electron transfer activity of a multi-cofactor protein that incorporates essential elements of photosynthetic reaction centers. This highly stable, modular artificial protein framework can be reconstituted in vitro with interchangeable redox centers for nanometer-scale photochemical charge separation. Transient absorption spectroscopy demonstrates Photosystem II-like tyrosine and metal cluster oxidation, and we measure charge separation lifetimes exceeding 100 ms, ideal for light-activated catalysis. This de novo-designed reaction center builds upon engineering guidelines established for charge separation in earlier synthetic photochemical triads and modified natural proteins, and it shows how synthetic biology may lead to a new generation of genetically encoded, light-powered catalysts for solar fuel production.

59 BASIC BIOLOGICAL SCIENCES↗

ComStock Measure Scenario Documentation: Laboratory-Informed Modeling of Standard Performance Heat Pump Rooftop Units

This measure scenario replaces gas and electric resistance RTUs in the U.S. commercial building stock with standard efficiency commercial off the shelf heat pump rooftop units. This study uses performance data informed by NREL laboratory testing of a standard efficiency 7.5-ton heat pump RTU. This is the key distinction between this measure scenario and a similar ComStock measure scenario - Standard Performance Heat Pump Rooftop Units - that uses published manufacturer data tables to inform performance. These two scenarios are compared in this report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Handling Unit Shutdowns During Scheduled Unoccupied Hours: US Commercial Building Stock Prevalence and Energy Impact

Commercial buildings account for 18% of U.S. energy consumption, with 44% used for heating, ventilation, and air conditioning (HVAC). American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) 90.1 requires HVAC systems to shutdown fans and outdoor air ventilation during unoccupied times, only allowing fans to cycle on, without outdoor air, to maintain thermostat setpoints. However, it is minimally understood how often existing building operations align with energy code requirements and the energy implications of not doing so. This study used building automation system data from 843 buildings containing 5706 air handling units (AHUs) to determine three unoccupied AHU shutdown control schemes ranging in efficiency and then estimated their prevalence in the U.S. commercial building stock, segmented by building type. ComStock was then used to analyze the energy savings potential of implementing the most energy efficient unoccupied shutdown control scheme in non-participating buildings across the U.S commercial building stock. Results show that only 23% of AHUs align completely with the ASHRAE 90.1 requirement. ComStock modeling results show 4% annual stock energy savings by switching all non-participating buildings to the most efficient scheme, with 19% annual energy savings demonstrated for the median building switching from the least efficient scheme to the most efficient. Findings also show 114.5 TBtu electricity and 75.8 TBtu natural gas fuel savings when converting to the most efficient scheme. Furthermore, these findings help stakeholders understand the high prevalence of buildings not aligning with the ASHRAE-90.1 requirements for unoccupied AHU shutdowns and the energy savings potential of utilizing the most efficient unoccupied AHU shutdown scheme.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Implementation of Fault-Correction Algorithms in Fault Detection and Diagnostics Tools

A fault detection and diagnostics (FDD) tool is a type of energy management and information system that continuously identifies the presence of faults and efficiency improvement opportunities through a one-way interface to the building automation system and the application of automated analytics. Building operators on the leading edge of technology adoption use FDD tools to enable median whole-building portfolio savings of 8%. Although FDD tools can inform operators of operational faults, currently an action is always required to correct the faults to generate energy savings. A subset of faults, however, such as biased sensors, can be addressed automatically, eliminating the need for staff intervention. Automating this fault “correction” can significantly increase the savings generated by FDD tools and reduce the reliance on human intervention. Doing so is expected to advance the usability and technical and economic performance of FDD technologies. This paper presents the development of nine innovative fault auto-correction algorithms for Heating, Ventilation, and Air Conditioning pi(HVAC) systems. When the auto-correction routine is triggered, it overwrites control setpoints or other variables to implement the intended changes. It also discusses the implementation of the auto-correction algorithms in commercial FDD software products, the integration of these strategies with building automation systems and their preliminary testing.

field testing↗

Accelerating Optimal Integration of Energy Efficiency Strategies with Industrialized Modular Construction: Preprint

The National Renewable Energy Laboratory's (NREL's) Industrialized Construction Innovation team first introduced the Industrialized Construction Assessment Framework to achieve affordable, net-zero energy (NZE) modular multifamily buildings in the 2020 ACEEE paper "Integrating Energy Efficiency Strategies with Industrialized Construction for our Clean Energy Future." Since then, NREL has continued to drive the ambitious plan to accelerate optimal integration of energy efficiency strategies during industrialized construction with little or no additional cost, labor, and production time. This follow-on paper introduces the Energy in Modular (EMOD) buildings method and presents NREL's research efforts over the last two years in collaboration with industry, including affordable housing partners. NREL has developed an idealized NZE modular multifamily building design that incorporates five energy efficiency strategies well suited for industrialized construction in factories: (1) envelope thermal control, (2) envelope infiltration control, (3) mechanical, electrical, and plumbing systems, (4) smart controls, and (5) solar plus storage. This paper highlights results from leveraging design for manufacturing and assembly principles, testing, and validation pilots with factory partners; demonstrating pod prototypes in test stand at NREL; and performing simulations. Overall, these research efforts address barriers to whole-building system integration, such as poor installation quality of thermal and air barriers; lack of unitized systems for space conditioning, energy recovery and ventilation, and water heating; problematic on-site installation, commissioning, and configuration of controls; and lack of cost-effective integration for grid-friendly design and emerging technologies. Conclusively, the paper delineates next steps for future work with NREL's partners toward developing a transformational pathway for our clean energy future.

affordable housing↗

Perspectives on the FESAC transformative enabling capabilities: Priorities, plans, and Status

In early 2017, the Fusion Energy Sciences Advisory Committee (FESAC), an advisory committee to the United States Department of Energy, was charged with identifying transformative enabling capabilities (TECs) “that could promote efficient advance toward fusion energy, building on burning plasma science and technology.” A subcommittee with broad expertise was formed and sought feedback from scientific experts, including experts from outside the fusion community. Three workshops were conducted, and a report was approved by FESAC in 2018 that identified four of the “most promising” TECs: advanced algorithms, high-critical-temperature superconductors, advanced materials and manufacturing, and novel technologies for tritium fuel cycle control. In addition, one “promising” TEC was identified: fast flowing liquid metal plasma-facing components. This paper will give details on the promising TECs and an overview on considerations of these TECs in the United States since the publication of the report.

Lumsdaine, Arnold↗

NASA's Habitat Demonstration Unit (HDU) Pressurized Excursion Module (PEM) In-Field Demonstration at Desert RATS 2010

This paper describes the construction, assembly, subsystem integration, transportation, and field testing operations associated with the Habitat Demonstration Unit (HDU) Pressurized Excursion Module (PEM) and discusses lessons learned. In a one-year period beginning summer 2009, a tightly scheduled design-develop-build process was utilized by a small NASA "tiger team" to produce the functional HDU-PEM prototype in time to participate in the 2010 Desert Research and Technology Studies (Desert RATS) field campaign. The process required the coordination of multiple teams, subcontractors, facility management and safety staff. It also required a well-choreographed material handling and transportation process to deliver the finished product from the NASA-Johnson Space Center facilities to the remote Arizona desert locations of the field test. Significant findings of this paper include the team s greater understanding of the HDU-PEM s many integration issues and the in-field training the team acquired which will enable the implementation of the next-generation of improvements and development of high-fidelity field operations in a harsh environment. The Desert RATS analog environment is being promoted by NASA as an efficient means to design, build, and integrate multiple technologies in a mission architecture context, with the eventual goal of evolving the technologies into robust flight hardware systems. The HDU-PEM in-field demonstration at Desert RATS 2010 provided a validation process for the integration team, which has already begun to retool for the 2011 field tests that require an adapted architecture.

Tri, Terry O.↗

Scheduling Operations for Massive Heterogeneous Clusters

High-performance computing (HPC) programming has become increasingly difficult with the advent of hybrid supercomputers consisting of multicore CPUs and accelerator boards such as the GPU. Manual tuning of software to achieve high performance on this type of machine has been performed by programmers. This is needlessly difficult and prone to being invalidated by new hardware, new software, or changes in the underlying code. A system was developed for task-based representation of programs, which when coupled with a scheduler and runtime system, allows for many benefits, including higher performance and utilization of computational resources, easier programming and porting, and adaptations of code during runtime. The system consists of a method of representing computer algorithms as a series of data-dependent tasks. The series forms a graph, which can be scheduled for execution on many nodes of a supercomputer efficiently by a computer algorithm. The schedule is executed by a dispatch component, which is tailored to understand all of the hardware types that may be available within the system. The scheduler is informed by a cluster mapping tool, which generates a topology of available resources and their strengths and communication costs. Software is decoupled from its hardware, which aids in porting to future architectures. A computer algorithm schedules all operations, which for systems of high complexity (i.e., most NASA codes), cannot be performed optimally by a human. The system aids in reducing repetitive code, such as communication code, and aids in the reduction of redundant code across projects. It adds new features to code automatically, such as recovering from a lost node or the ability to modify the code while running. In this project, the innovators at the time of this reporting intend to develop two distinct technologies that build upon each other and both of which serve as building blocks for more efficient HPC usage. First is the scheduling and dynamic execution framework, and the second is scalable linear algebra libraries that are built directly on the former.

Humphrey, John↗

AGT100 turbomachinery

High-performance turbomachinery components have been designed and tested for the AGT100 automotive engine. The required wide range of operation coupled with the small component size, compact packaging, and low cost of production provide significant aerodynamic challenges. Aerodynamic design and development testing of the centrifugal compressor and two radial turbines are described. The compressor achieved design flow, pressure ratio, and surge margin on the initial build. Variable inlet guide vanes have proven effective in modulating flow capacity and in improving part-speed efficiency. With optimum use of the variable inlet guide vanes, the initial efficiency goals have been demonstrated in the critical idle-to-70% gasifier speed range. The gasifier turbine exceeded initial performance goals and demonstrated good performance over a wide range. The radial power turbine achieved 'developed' efficiency goals on the first build.

Tipton, D. L.↗

Prefabricated Zero Energy Retrofit Technologies: A Market Assessment

Part of the U.S. Department of Energy's (DOE) Office of Energy Efficiency and Renewable Energy’s (EERE’s) strategic goals is to stimulate the growth of a thriving domestic clean energy manufacturing industry. This report seeks to identify products in the European and U.S. markets that can enable a more integrated and standardized approach to conducting zero energy retrofits, leveraging off-site construction and manufacturing. Greater integration of energy conservation measures into prefabricated building components will further enable efficiency adoption, while reducing project complexity, risks, and costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling and analysis of heat emissions from buildings to ambient air

Heat emissions from buildings is a significant source of anthropogenic heat influencing the urban microclimate; however, they are usually oversimplified in urban climate and microclimate modeling. This study developed a bottom-up physics-based approach to calculate heat emissions from buildings to the ambient air and implemented the approach in EnergyPlus. In this work, a simple result verification was conducted by comparing the EnergyPlus simulated results against the spreadsheet calculations. Simulations covering 16 commercial building types, four climates, and two energy efficiency levels were conducted to understand and evaluate the building heat emissions and their temporal patterns as well as three major components: (1) building envelope (convective heat transfer to ambient air), (2) zones (air exfiltration and exhaust air), and (3) HVAC systems (relief air and heat rejection from condensers or cooling towers). The main findings are: (1) heat emissions are usually higher than the site energy use (about 2.5 times), and their dynamics should be considered; (2) building characteristics and their energy systems lead to differences in heat emission contributions from the three components, and their dynamics, for example, in the warehouse models, the envelope component accounts for 90.4%, while it is 12.7% for the large office models; (3) for most building typologies, the climate has a strong impact on heat emissions, for example, buildings with dominant heat emissions from the zone exhaust air and/or the HVAC reject heat, a general decrease in heat emissions in hotter climates is observed, while envelope-dominated buildings show the opposite; and (4) building technologies that reduce energy use in buildings may perform differently in reducing heat emissions. The developed heat emissions calculation method can be adopted in EnergyPlus and most other building energy modeling programs. It can provide dynamic building heat emissions as an input to urban climate computational fluid dynamics (CFD) models at a higher spatial and temporal resolution than is currently available, to improve the simulation accuracy of the urban microclimate and capture the urban heat island effect and urban overheating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of Electric Space Heating in Multifamily Apartments in Juneau, Alaska [Slides]

The study objective was to understand the change in electrical consumption and cost after the addition of a ductless mini-split air-source heat pump (ASHP) across rental apartments heated by electrical resistance heating systems in multifamily buildings in Juneau, Alaska. Alaska Electric Light and Power Company (AELP), the utility in Juneau, Alaska, funded installation of 19 heat pumps across four buildings. Using electrical meter interval data, including the total apartment consumption and submeter data for each heating appliance (electric resistance baseboard and heat pump), the National Laboratory of the Rockies (NLR) calculated energy use metrics before and after heat pump installation and visualized results. Through this research, NLR compares electrical use (total and specific to heating appliances), adjusted for weather and apartment size, and electrical demand in the year before and after installation of an ASHP across study units. The results will inform the utility and residents of documented energy and cost savings from transitioning building heating systems to a higher-efficiency electricity-based appliance, deliver a basis for building energy modeling across other multifamily housing dwellings, and enable estimates of potential electricity savings to AELP grid under widespread adoption scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulating energy performance of buildings: a study using eQUEST and Energy Star ® portfolio manager

Commercial buildings consume significant energy in the United States and exhibit high potential for energy use reduction through retrofits. Benchmarking and energy simulation are well established tools in the industry to identify potential improvements and measure performance. Analysis to identify most sensitive retrofit parameters to energy performance can optimize investment and available energy savings. Presented study demonstrates methodology using a static model to determine sensitivity of building design and retrofit parameters with respect to energy performance. Calibrated simulation energy models (eQUEST) of two distribution centers (A, B) are presented. A fractional factorial analysis is conducted on retrofit parameters of efficiency measures targeting the highest energy consumers, and the results are benchmarked using Energy Star® Portfolio Manager. A custom Microsoft Excel® based simulation model is created to simulate occupancy levels, lighting, plug loads, and other equipment used in various spaces throughout the day. For Building A, efficient lighting was the most influential parameter for energy savings, carbon savings and benchmarking score; whereas, for Building B, HVAC efficiency was most influential for energy and demand controlled ventilation and economizers was most influential for benchmarking score. While retrofit projects can save energy and carbon emissions, variation in source-site ratios and state grid emissions, benchmarking scores may not always reflect equivalent improvement. State grid emissions factors, natural gas composition are difficult to model and hence not considered in this study. In conclusion, the synergistic analysis presented, emphasizes the importance of benchmarking and efficiency retrofits in promoting sustainable building practices to reduce energy consumption.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

System Retrofits in Efficiency Programs: Track Record and Outlook

Commercial building retrofits are often limited to simple upgrades of individual building components such as equipment or lamp replacements. These equipment- or component-level retrofits have been shown to have less potential for whole building energy savings (50% less in studied cases) compared to comprehensive system-based approaches. System retrofits with their potential for much greater savings are critical to achieving aggressive energy reduction goals in the existing building stock but to date there has been little deep analysis of the track record and trends for systems retrofits in commercial buildings. This paper addresses several questions: 1. To what extent are systems retrofits taking place in the building retrofit marketplace today? 2. Do current systems retrofits in fact save more energy than component retrofits? 3. What kinds of efficiency measures are currently most prevalent in system retrofits? 4. Does systems adoption vary across different retrofit programmatic approaches (e.g. utility incentive programs, federal retrofit programs, ESCOs)? Findings, based on an analysis of retrofit data from 12,000 projects across the U.S. from custom utility incentive programs, federal retrofit programs, and Energy Service Companies (ESCOs), indicate the state of the current market with respect to adoption of systems technologies. A wide range of stakeholders were also interviewed to define the challenges and opportunities for greater deployment. A range of barriers is presented including technical and structural (i.e. programmatic, policy), along with recommendations to accelerate deployment of these strategic approaches.

Regnier, Cynthia↗

GT Flex: A Coordinated Multi-Building Pilot Study

Buildings are a significant and untapped resource for providing utility electric grid services. Recent studies have estimated that buildings could reduce the peak demand on the electric grid in the U.S. by almost 25% through effective combinations of energy efficiency (EE) measures and load flexibility strategies (Langevin et al. 2021). The U.S. Department of Energy (DOE) has established a goal to triple energy efficiency and demand flexibility in both residential and commercial sections by 2030 compared to 2020 levels (Satchwell et al. 2021). Such findings place buildings alongside electric vehicles, photovoltaics, electric batteries, and other distributed energy resources (DERs) as primary technologies needed for supporting high renewable energy generation grids. Coordinating and optimizing multiple buildings and other DERs is more beneficial and valuable when compared with individual buildings and DERs operating as siloed resources, uncoordinated with others (Olgyay et al. 2020). A pilot study at the Georgia Institute of Technology (GIT) was conducted to evaluate value propositions of a multi-building scale project seeking carbon reduction, energy efficiency and grid-interactive capabilities, by demonstrating the means by which stakeholders can determine the technical and financial merits of grid-interactivity and energy efficiency technologies coordinated across multiple assets. The study focused on analyzing technical feasibility of deploying thermal load flexibility strategies at the multi-building scale, coordinated to not exceed existing infrastructure constraints at the pilot site. Results show that campus can provide 3-3.5 MW of potential load shed over a 4-hour event window through coordinated dispatch of thermal cooling load flexibility without exceeding existing infrastructure capacities. Under future high renewable scenarios, this thermal flexibility resource is also valuable when coordinated to reduce curtailment of intermittent renewables. Economic analyses were performed to effectively communicate various value propositions of grid-interactive and efficient building (GEB) thermal flexibility strategies. Load flexibility presents a financial value proposition to the campus today. By conducting rationalized, coordinated dispatch in response to real time price (RTP) fluctuations, the campus can benefit materially from daily price arbitrage. The RTP signal acts as an aggregating mechanism between the utility and customer to call on demand flexibility resources, with a large portion of the benefit deriving from a relatively small number of days. Realizing and maximizing this benefit with thermal load flexibility requires careful attention to the timing of pricing signals and parameterization of dispatch to overcome efficiency penalties. Grid value and signals are expected to evolve over time, and thermal load flexibility shows potential to adapt dispatch logic to support intermittent renewable generation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

All‐Polymer Bulk‐Heterojunction Organic Electrochemical Transistors with Balanced Ionic and Electronic Transport

Abstract The rapid development of organic electrochemical transistor (OECTs)‐based circuits brings new opportunities for next‐generation integrated bioelectronics. The all‐polymer bulk‐heterojunction (BHJ) offers an attractive, inexpensive alternative to achieve efficient ambipolar OECTs, and building blocks of logic circuits constructed from them, but have not been investigated to date. Here, the first all‐polymer BHJ‐based OECTs are reported, consisting of a blend of new p‐type ladder conjugated polymer and a state‐of‐the‐art n‐type ladder polymer. The whole ladder‐type polymer BHJ also proves that side chains are not necessary for good ion transport. Instead, the polymer nanostructures play a critical role in the ion penetration and transportation and thus in the device performance. It also provides a facile strategy and simplifies the fabrication process, forgoing the need to pattern multiple active layers. In addition, the development of complementary metal–oxide–semiconductor (CMOS)‐like OECTs allows the pursuit of advanced functional logic circuitry, including inverters and NAND gates, as well as for amplifying electrophysiology signals. This work opens a new approach to the design of new materials for OECTs and will contribute to the development of organic heterojunctions for ambipolar OECTs toward high‐performing logic circuits.

Chemistry↗

Multi-physics Peridynamic Modeling of Damage Processes in Protective Coatings

Protective coatings can revolutionize the aerospace industry by providing a way to build a fuel-efficient and low-emission gas turbine engine operating at elevated temperature. Currently, significant challenges persist in the multi-physics modeling of damage processes in protective coatings exposed to the hot corrosive environment of gas turbine engine. Examples of such detrimental processes include an interface damage between different material layers forming protective coating, a formation of the through-the-thickness vertical cracks, a diffusion of oxygen and moisture through those cracks, an oxidation, and a delamination. In this paper, a feasibility of a multi-physics peridynamic model to provide insight to these detrimental processes has been demonstrated. 3-Dimensional peridynamic equations which are valid everywhere, including dynamically evolving discontinuities, have been presented. In conclusion, validation and demonstration have been shown for conduction heat transfer, reactive oxidation, and delamination of protective coating with a composition borrowed from the open literature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗