Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Optimal operation of multi-plant steam district heating systems for enhanced efficiency and sustainability

Despite their crucial role in supplying heat and power to universities, industries, and healthcare facilities, many steam-based district heating systems rely on outdated control methods. Among these, multi-central plant districts are particularly challenging due to the complexities of coordinating multiple plants, optimizing load distributions, and managing system downtime. In response, new operational strategies are developed to enhance the efficiency and sustainability of steam districts while utilizing existing resources. These strategies include reducing plant operational pressure without compromising the reliable supply to buildings and optimizing load allocation across multiple plants. The load allocation considers boiler part-load efficiency, runtime, network losses, and building pressure set points, and is compared with traditional multi-boiler controls. To support this exploration, new dynamic Modelica models are developed. In addition, methods to reduce modeling complexities are incorporated, enhancing their suitability for practical applications. A holistic district-wide analysis using a real university case study demonstrates a 4.7% fuel savings by lowering boiler operational pressure from 900 kPa to 600 kPa, along with a 13.3% reduction in condensation losses across the distribution network. Furthermore, the load allocation approach results in a 13.1% reduction in fuel consumption during peak winter periods and 15.3% during shoulder periods, with corresponding decreases in carbon emissions and fuel costs. This approach can also save maintenance costs by reducing the boiler runtime by 49.6%. In conclusion, this research underscores the benefits of retrofitting aging steam district heating systems, offering immediate operational improvements by enhancing efficiency, meeting regulatory compliance, and extending infrastructure lifespans while delaying costly overhauls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Shepherding Metadata Through the Building Lifecycle

Many different digital representations of a building are produced over the course of its lifecycle. These representations contain the metadata required to support different stages of the building, from initial planning and design, to construction and commissioning, through operations, audits, retrofits and maintenance. However, because of differences in the semantics, structure and syntax of these representations, the metadata they contain is not interoperable. We present a novel method for leveraging these representations to create a unified, authoritative Brick metadata model for a building that can be continually maintained over the course of the building lifecycle. A simple synchronization protocol relays inferred Brick metadata from existing metadata sources such as gbXML, BuildingSync, Project Haystack and Modelica to a central integration server, which merges the metadata into a valid Brick model.

Fierro, Gabe↗

Stochastic scheduling for commercial building cooling systems: considering uncertainty in zone temperature prediction

Here, this paper presents the first attempt to address the uncertainty in zone temperature prediction with stochastic optimization. The uncertain zone temperature is a process uncertainty and has not been considered in the existing stochastic optimization for building control. To fill this gap, we proposed a novel formulation of stochastic optimization to handle process uncertainty in building control. Specifically, we first examined the accuracy of a typical linear model for predicting zone temperature. We then formulated the scheduling of the building cooling system as a stochastic optimization problem over a 24-hour look-ahead period to minimize the electricity cost of the studied building cooling system. After that, we applied the proposed stochastic load scheduling (SLS) to a direct expansion (DX) cooling system that serves a medium office building. Through simulation with a detailed building energy simulation software, EnergyPlus, we evaluated the operational cost and the thermal comfort compared with a deterministic load scheduling. The operation cost of scheduling was found to vary with the level of zone temperature prediction uncertainty. The proposed SLS can mitigate the impacts of uncertain zone temperature predictions on both operational cost and thermal comfort. The evaluation results indicate that the proposed SLS works better when the uncertainty level is more significant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Composing effective prediction at five points

Color-kinematics duality in the adjoint has proven key to the relationship between gauge and gravity theory scattering amplitude predictions. In recent work, we demonstrated that at four-point tree-level, a small number of color-dual EFT building blocks could encode all higher-derivative single-trace massless corrections to gauge and gravity theories compatible with adjoint double-copy. One critical aspect was the trivialization of building higher-derivative color-weights — indeed, it is the mixing of kinematics with non-adjoint-type color-weights (like the permutation-invariant d 4 ) which permits description via adjoint double-copy. Here we find that such ideas clarify the predictions of local five-point higher-dimensional operators as well. We demonstrate how a single scalar building block can be combined with color structures to build higher-derivative color factors that generate, through double copy, the amplitudes associated with higher-derivative gauge-theory operators. These may then be suitably mapped, through another double-copy, to higher-derivative corrections in gravity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TQEA: Temporal Quantum Error Analysis

For the last few years quantum computers have captured researchers’ interest in solving complicated problems in finance, chemistry, machine learning, and many other NP problems. Quantum computing benefits from parallel computation, entanglement, and calculation speedup compared to classical computing. Even though the operations and number of qubits in quantum computers are limited, previous research showed that using quantum computers can be beneficial. These benefits gained researchers’ interest to work on the improvement of quantum computers and overcome the limitations by building more advanced quantum computers with fault tolerance capability, more physical qubits, and better operational gates. In practice, Quantum applications would be translated into Quantum Circuits and each circuit can contain one or many entanglements (s), single qubits operations, and readouts. The importance of running Quantum applications with controlled errors or without errors is critical to the desired result from Quantum readout. In this paper, we study the characteristics of superconducting quantum machines along with the previously proposed methods of Quantum error detection/correction and in order to build a better error model we propose a temporal method for analyzing the the behavior of qubits errors (T1 and T2), frequency of operation, entanglement errors, and readout errors. In order to detect and predict the behavior of each machine, we use simple exponential smoothing analysis on heuristic calibration data. Finally, based on observation, we show that based on frequency, qubits, readout and single operation errors we can build a temporal based model to study and predict the outcome of runs on each Quantum machine.

Baheri, Betis↗

Application of reference-free natural background–oriented schlieren photography for visualizing leakage sites in building walls

Air leakage in buildings can cause health and comfort concerns for occupants and can contribute to mold growth on building materials, or in extreme conditions, rot of building materials. Unwanted air leakage through the building envelope also contributes to approximately 4 quadrillion Btu (1172 TWh) of energy consumption per year in the building sector in the United States. Locating and sealing leakage sites can improve the energy efficiency, comfort, air quality, and moisture durability of the building stock. Typical methods of finding leakage sites, such as infrared imaging and smoke tracing, rely on concurrent blower door operation, which can also measure the total leakage rate of the building. Smoke tracing can be disruptive to occupants, and infrared imaging and smoke tracing cannot measure the contribution of individual leaks to prioritize sealing efforts. Here, an optical fluid flow imaging technique, reference-free natural background–oriented schlieren imaging, was adapted to visualize air exfiltration. This is the first step in developing a method to noninvasively locate and measure exfiltration or infiltration sites so that sealing efforts can be prioritized. Experimental results of this technique are presented, demonstrating the method's applicability to visualizing exfiltration through three common building claddings in an outdoor environment. Key variables impacting the performance of this technique when applied to building leakage are also discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cost and Performance Analysis for Five Existing Geothermal Heat Pump-Based District Energy Systems in the United States

District energy systems supplied by geothermal heat pumps (GHPs) have been deployed across the United States for both heating and cooling end uses. To better understand their performance and potential, the geothermal research team at the National Renewable Energy Laboratory analyzed cost and performance of five existing GHP-based district energy systems in the United States. The five systems selected are Ball State University in Indiana, Colorado Mesa University in Colorado, Miami University in Ohio, West Union in Iowa, and Whisper Valley in Texas. The necessary information, including district size, operation period, GHP performance, and costs, was collected through literature review and interviews. The survey results indicated the five systems studied consist of geothermal borehole field(s) and ground loop(s) connected to central loop. While the GHPs were in central plants at Ball State University and Miami University, the central loops at Colorado Mesa University, West Wood, and Whisper Valley were connected through service lines to individual heat pumps in each building. Our analysis indicates the systems have been operating reliably and cost-effectively and contributed to a reduction in carbon emissions.

15 GEOTHERMAL ENERGY↗

How Can Floor Covering Influence Buildings’ Demand Flexibility?

Although the thermal mass of floors in buildings has been demonstrated to help shift cooling load, there is still a lack of information about how floor covering can influence the floor’s load shifting capability and buildings’ demand flexibility. To fill this gap, we estimated demand flexibility based on the daily peak cooling load reduction for different floor configurations and regions, using EnergyPlus simulations. As a demand response strategy, we used precooling and global temperature adjustment. The result demonstrated an adverse impact of floor covering on the building’s demand flexibility. Specifically, under the same demand response strategy, the daily peak cooling load reductions were up to 20–34% for a concrete floor whereas they were only 17–29% for a carpet-covered concrete floor. This is because floor covering hinders convective coupling between the concrete floor surface and the zone air and reduces radiative heat transfer between the concrete floor surface and the surrounding environment. In hot climates such as Phoenix, floor covering almost negated the concrete floor’s load shifting capability and yielded low demand flexibility as a wood floor, representing low thermal mass. Sensitivity analyses showed that floor covering’s effects can be more profound with a larger carpet-covered area, a greater temperature adjustment depth, or a higher radiant heat gain. With this effect ignored for a given building, its demand flexibility would be overestimated, which could prevent grid operators from obtaining sufficient demand flexibility to maintain a grid. Our findings also imply that for more efficient grid-interactive buildings, a traditional standard for floor design could be modified with increasing renewable penetration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rancor Integrated Procedure System (RIPS): A Computer-Based Procedure Platform for Advanced Reactor Research

The Rancor Microworld Simulator is a simplified, pressurized water, small modular reactor simulator that includes a multi-unit plant model server, an advanced digital human-machine control interface, and the Rancor Integrated Procedure System (RIPS). Rancor provides a research and development tool that can be used for collecting operator performance data and for prototyping concepts of operations (ConOps) for advanced reactor development. RIPS is meant as a research tool and includes many unique features: (1) RIPS has a robust procedure authoring system. (2) RIPS has the capability to run any of the three IEEE-Std-1786 computer-based procedure types. (3) RIPS can be configured to take on the look and feel of different vendors’ computer-based procedure systems for the purpose of developing and evaluating different ConOps for plant upgrades or new builds. (4) RIPS includes the capability for logging operator procedure use, including integrating procedure logs with Rancor simulator logs, thereby allowing automated data collection of operator scenario runs. (5) RIPS integrates with the Human Unimodel for Nuclear Technology to Enhance Reliability (HUNTER), a dynamic human reliability analysis environment that creates a digital human twin or virtual operator to mimic reactor operator performance. (6) RIPS includes support for automation of plant monitoring and control functions. While RIPS is explicitly built into Rancor, it may also be used with full-scope training simulators. This functionality allows RIPS to be used for existing plants and advanced reactors under development.

99 - GENERAL AND MISCELLANEOUS↗

Projected Operational Energy Life Cycle Data 2025

These excel files contain the environmental emission projections for key building energy sources: electricity, natural gas, propane (LPG), and fuel oil. The sources and methods are provided in the report "Projected Operational Energy Life Cycle Data Development: 2025 Update." The report and data are an update to the data previously posted here: https://netl.doe.gov/energy-analysis/details?id=f8890fac-be55-44ac-aaa9-e2888bfabe93

annual energy outlook↗

Energy Management Information Systems Cybersecurity Best Practices

Energy management information systems (EMIS) are a broad and rapidly evolving family of tools that monitor, analyze, and control building energy use and system performance. Critical systems are often integrated with or operate on the same networks as EMIS scope systems, necessitating stable, continuous, and secure communication. When connecting EMIS to building automation and utility control systems, there are also many physical assets that could cause harm to the building and its occupants if a malicious act or human error were introduced. It is imperative to ensure all EMIS scope systems are connected securely to the EMIS and do not open vulnerable pathways to other facility networks and operations. The Federal Energy Management Program (FEMP) promotes best practices for impactful utilization of EMIS at federal facilities. This best practice document is part of a series of fact sheets created to help accelerate the market adoption and use of EMIS in the federal sector. It provides an overview of required EMIS cybersecurity standards for compliance and authority to operate along with additional recommendations.

cybersecurity↗

Energy Management Information Systems Cybersecurity Best Practices

Energy management information systems (EMIS) are a broad and rapidly evolving family of tools that monitor, analyze, and control building energy use and system performance. Critical systems are often integrated with or operate on the same networks as EMIS scope systems, necessitating stable, continuous, and secure communication. When connecting EMIS to building automation and utility control systems, there are also many physical assets that could cause harm to the building and its occupants if a malicious act or human error were introduced. It is imperative to ensure all EMIS scope systems are connected securely to the EMIS and do not open vulnerable pathways to other facility networks and operations. The Federal Energy Management Program (FEMP) promotes best practices for impactful utilization of EMIS at federal facilities. This best practice document is part of a series of fact sheets created to help accelerate the market adoption and use of EMIS in the federal sector. It provides an overview of required EMIS cybersecurity standards for compliance and authority to operate along with additional recommendations.

Cybersecurity↗

An Architectural Survey of the Pluto Test Bunker Facility, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), in conjunction with the National Nuclear Security Administration Nevada Field Office (NNSA/NFO), proposes to reactivate Building 26-2205 as part of a project to detect foundry-type operations with remote sensing. The project is known as the Signals Exploration Testbed, or SET for short. Building 26-2205 (State Historic Preservation Office [SHPO] Resource No. B11558) is the former Compressor Building for the Pluto Program in Area 26 of the Nevada National Security Site (NNSS). Proposed actions at Building 26-2205 include removal of exterior building and site features, such as fencing, concrete pads, a large steel tank, and visible utilities, as well as interior changes to the building’s floor plan. These activities constitute an undertaking subject to review under Section 106 of the National Historic Preservation Act (NHPA) (54 United States Code [USC] § 306101) and its implementing regulations, 36 Code of Federal Regulations (CFR) Part 800.

54 ENVIRONMENTAL SCIENCES↗

Energy and power quality measurement for electrical distribution in AC and DC microgrid buildings

Today's selection of DC microgrid buildings features a diverse set of electrical topologies and turnkey solutions, each with specific design trade-offs and optimizations. Designers desperately need standardized metrics and procedures for measurement and verification (M&V) to analyze and compare the advantages of each DC solution to traditional AC building networks. This work develops M&V procedures for quantifying and comparing the energy efficiency and power quality in buildings. To calculate full-building efficiency, this work introduces the measurement-informed modeling method, a procedure that develops and refines a building's energy model with metered data. To quantify power quality, this work defines a new voltage quality index that applies to both AC and DC buildings. This article describes the equipment, instrumentation, and operation necessary to calculate the efficiency and power quality. It then demonstrates these methods with a set of field tests. We report these M&V procedures can ultimately be used to compare and improve the efficiency and power quality of various DC topologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building fault detection data to aid diagnostic algorithm creation and performance testing

It is estimated that approximately 4-5% of national energy consumption can be saved through corrections to existing commercial building controls infrastructure and resulting improvements to efficiency. Correspondingly, automated fault detection and diagnostics (FDD) algorithms are designed to identify the presence of operational faults and their root causes. A diversity of techniques is used for FDD spanning physical models, black box, and rule-based approaches. A persistent challenge has been the lack of common datasets and test methods to benchmark their performance accuracy. This article presents a first of its kind public dataset with ground-truth data on the presence and absence of building faults. This dataset spans a range of seasons and operational conditions and encompasses multiple building system types. It contains information on fault severity, as well as data points reflective of the measurements in building control systems that FDD algorithms typically have access to. The data were created using simulation models as well as experimental test facilities, and will be expanded over time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of smart charging for electric vehicle-to-building integration: A case study

Higher electric vehicle (EV) adoption will stress the importance of demand flexibility to achieve more economic, efficient, and reliable grid operation. Charging technologies will be paramount in shifting temporally to better fit the variable generation of wind and solar. As such, analysis is warranted on the benefits of EV charge scheduling with respect to installation cost, operation cost, difficulty of implementation, and grid flexibility. We tackle this by analyzing the cost savings of implementing an EV charge scheduling infrastructure to reduce demand charges and installation costs. In this paper, we analyze a case study for operation of 16 level 2 chargers and 1 fast charger for two different building types. We then evaluate various test phases for controlling building and charging loads using an adaptive charging network (ACN) algorithm to characterize the ACN’s potential to reduce overall project cost.

30 DIRECT ENERGY CONVERSION↗

Build Orientation Dependent Microstructure in Polymer Laser Sintering: Relationship to Part Performance and Evolution with Aging

Laser sintering (LS) is widely used to produce functional polymeric parts; however, the resulting parts are often limited by their porous structure, and performance of the part may be strongly anisotropic. Relating the structural features of parts to build process conditions or powder feedstock has been explored previously. In contrast, little is known regarding how the unique internal structures of LS parts evolve and relate to their performance later in their life cycle, for example, after use in a real-world operating environment. In this study, a tightly controlled LS build process and measurement campaign by standard X-ray computed tomography (XCT), supported by high-resolution synchrotron XCT, was used to benchmark the internal microstructure (e.g. porosity) as a function of four different build orientations in printed polyamide-12 (PA-12) parts. The initial performance of the parts after printing was characterized by tensile testing and dynamic mechanical analysis (DMA). Arrays of PA-12 parts in different build orientations were exposed to steam (under pressure) and air across multiple temperature and time points for the purposes of accelerated aging through oxidative and hydrolytic breakdown. Exposing parts to steam dramatically altered the internal microstructure and functional properties such as the glass transition temperature, tensile properties, and damping behavior. Notably, post-aging XCT revealed large microstructural changes after only 40 h of steam treatment relative to the as-printed specimens. Furthermore, pore reorganization and changes in crystallinity occurred regardless of whether the steam temperature was aggressive enough to induce a significant loss in mechanical properties. The build orientation dependence on the aging rate was minimal with the relative trend in performance persisting across most metrics among the different orientations even after aging.

36 MATERIALS SCIENCE↗