At least 649 records · Page 36

Demonstration of a diamond anvil cell platform at the Linac Coherent Light Source: capabilities and outlook

A novel X-ray free electron laser (XFEL) diffraction setup for use with diamond anvil cells (DACs) at the Linac Coherent Light Source (LCLS) is described. The new diamond window at the Matter at Extreme Conditions (MEC) instrument allows hard X-ray experiments on DACs to be performed in air. The platform is described along with alignment and calibration procedures, and details of the X-ray beam and diagnostics. Example data are presented, including a reversible XFEL-induced phase transition in CsPbI 3 . The DAC setup was commissioned at MEC, but is applicable to most LCLS instruments where the unique pulse structures available at LCLS offer access to new ultrafast experimental techniques at high pressure.

Linac Coherent Light Source (LCLS)↗

Vector processing enhancements for real-time image analysis.

A real-time image analysis system was developed for beam imaging diagnostics. An Apple Power Mac G5 with an Active Silicon LFG frame grabber was used to capture video images that were processed and analyzed. Software routines were created to utilize vector-processing hardware to reduce the time to process images as compared to conventional methods. These improvements allow for more advanced image processing diagnostics to be performed in real time.

43 PARTICLE ACCELERATORS↗

Experimental Study of High-Z Gas Buffers in Gas-Filled ICF Engines

ICF power plants, such as the LIFE scheme at LLNL, may employ a high-Z, target-chamber gas-fill to moderate the first-wall heat-pulse due to x-rays and energetic ions released during target detonation. To reduce the uncertainties of cooling and beam/target propagation through such gas-filled chambers, we present a pulsed plasma source producing 2-5 eV plasma comprised of high-Z gases. We use a 5-kJ, 100-ns theta discharge for high peak plasma-heating-power, an electrode-less discharge for minimizing impurities, and unobstructed axial access for diagnostics and beam (and/or target) propagation studies. We will report on the plasma source requirements, design process, and the system design.

42 ENGINEERING↗

Non-circular electron beam spot welds in stainless steel alloys

Circularly symmetric-shaped spot welds are desirable for welding applications as they relate to heat and fluid flow conditions in the melt pool with predictable weld penetrations and repeatable results. Non-circular spot welds on the other hand result in undesirable and unpredictable weld penetrations or non-bridging of the liquid melt pool across the joint. Two known causes for non-circular melt pools occur when welding dissimilar metals, or when welding with skewed electron or laser beams that are not perpendicular to the surface. A largely unexplored additional factor, shown here, is an asymmetric power density distribution within the beam that can create non-circular melt pools even though the beam dimensions are much smaller than the melt pool itself.

36 MATERIALS SCIENCE↗

Muon Beam Dynamics and Spin Dynamics in the g-2 Storage Ring

The goal of the new g-2 experiment at fermilab is a measurement of the anomalous magnetic moment of the muon, with uncertainty of less than 140 ppb. The experimental method is to store a beam of polarized muons in a storage ring with pure vertical dipole field and electrostatic focusing, and to measure the precession frequency. Control of the systematics depends on unprecedented knowledge of the details of the phase space of the muon distribution. That knowledge is derived from direct measurements with scintillating fiber detectors that are inserted into the muon beam for diagnostic measurements, traceback straw tube tracking chambers, as well as the calorimeters that measure energy, time and position of the decay positrons. The interpretation of the measurements depends on a detailed model of the storage ring guide field. This invited talk presents results of studies of the distribution from the commissioning run of the experiment.

43 PARTICLE ACCELERATORS↗

Selecting 1D projections for 2D tomography reconstruction

Previous works on reconstructing the 4D phase space using tomography require optimal selection of projection views to achieve accurate reconstruction. In 2D reconstruction, the process is straightforward, as an object can be evenly sampled by dividing the angles evenly. However, extending this concept from 2D to 4D is not intuitive. This work demonstrates that quaternions can be used to more effectively describe views in 4D and introduces the Fibonacci Flower algorithm and repulsive force algorithm to evenly space views in 4D space in order to achieve higher reconstruction accuracy.

Accelerator Physics↗

A Client/Server Architecture for Supporting Science Data Using EPICS Version 4

The Phase 1 grant that serves as a precursor to this proposal, prototyped complex storage techniques for high speed structured data that is being produced in accelerator diagnostics and beam line experiments. It demonstrates the technologies that can be used to archive and retrieve complex data structures and provide the performance required by our new accelerators, instrumentations, and detectors. Phase 2 is proposed to develop a high-performance platform for data acquisition and analysis to provide physicists and operators a better understanding of the beam dynamics. This proposal includes developing a platform for reading 109 MHz data at 10 KHz rates through a multicore front end processor, archiving the data to an archive repository that is then indexed for fast retrieval. The data is then retrieved from this data archive, integrated with the scalar data, to provide data sets to client applications for analysis, use in feedback, and to aid in identifying problem with the instrumentation, plant, beam steering, or model. This development is built on EPICS version 4 , which is being successfully deployed to implement physics applications. Through prior SBIR grants, EPICS version 4 has a solid communication protocol for middle layer services (PVAccess), structured data representation and methods for efficient transportation and access (PVData), an operational hierarchical record environment (JAVA IOC), and prototypes for standard structured data (Normative Types). This work was further developed through project funding to successfully deploy the first service based physics application environment with demonstrated services that provide arbitrary object views, save sets, model, lattice, and unit conversion. Thin client physics applications have been developed in Python that implement quad centering, orbit display, bump control, and slow orbit feedback. This service based architecture has provided a very modular and robust environment that enables commissioning teams to rapidly develop and deploy small scripts that build on powerful services. These services are all built on relational database data stores and scalar data. The work proposed herein, builds on these previous successes to provide data acquisition of high speed data for online analysis clients.

43 PARTICLE ACCELERATORS↗

Sensitivity Analysis and Requirements for Temporally and Spatially Resolved Thermometry Using Neutron Resonance Spectroscopy

This report is intended to examine the use of neutron resonance spectroscopy (NRS) to make time- dependent and spatially-resolved temperature measurements of materials in extreme conditions. Specifically, the sensitivities of the temperature estimate on neutron-beam and diagnostic parameters is examined. Based on that examination, requirements are set on a pulsed neutron-source and diagnostics to make a meaningful measurement.

36 MATERIALS SCIENCE↗

Applying Matlab LOCO to the NSLSII Storage Ring Commissioning

Linear Optics from Closed Orbits (LOCO) has been a powerful beam-based diagnostics and optics control method for storage rings and synchrotrons worldwide ever since it was established at NSLS by J. Safranek. This method measures the orbit response matrix and optionally the dispersion function of the machine. The data are then fitted to a lattice model by adjusting parameters such as quadrupole and skew quadrupole strengths in the model, BPM gains and rolls, corrector gains and rolls of the measurement system. Any abnormality of the machine that affects the machine optics can then be identified. The resulting lattice model is equivalent to the real machine lattice as seen by the BPMs. Since there are usually two or more BPMs per betatron period in modern circular accelerators, the model is often a very accurate representation of the real machine. According to the fitting result, one can correct the machine lattice to the design lattice by changing the quadrupole and skew quadrupole strengths. LOCO is so important that it is routinely performed at many electron storage rings to guarantee machine performance, especially after the Matlab-based LOCO code became available. The Matlab version includes a user-friendly interface, with many useful fitting and analysis options.

36 MATERIALS SCIENCE↗

Innovations in optimization and control of accelerators using methods of differential geometry and genetic algorithms (Final Report)

Online tuning of particle accelerators is necessary in order to achieve optimal machine performance. However, it is also a major challenge due to the large parameter space which must be searched and the fact that many of the desir- able objectives compete with one another, and so will not reach their optimal values simultaneously. In order to mitigate these issues, we have explored using dimension-reduction techniques to reduce the size of the parameter space which must be searched and multi-objective genetic algorithms to obtain the sets of tuning parameters which provide pareto-optimal values for the objectives. These methods have enabled us to obtain improved values of the vertical emittance at the Cornell Electron Storage Ring (CESR), and to do so with greater control of orbit errors. Algorithmic tuning is a multidisciplinary endeavour, requiring expertise in beam dynamics, diagnostics, control systems and computer science, and thus a key practical problem is to formulate a common language in which experts with different specialties can communicate. We developed a solution to this problem in the form of a generic accelerator software interface that allows for rapid prototyping of optimization and control algorithms. Our interface is built on the Experimental Physics and Industrial Control Systems (EPICS) and makes possible testing control code in simulation before deployment on real accelerators, as well as deployment of third-party optimization code.

43 PARTICLE ACCELERATORS↗

Magnetic-Field Diffusion Effects in Beam Position Monitors I: Theory

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic-Field Diffusion Effects in Beam Position Monitors II: Application to Calibration Single-Pulse Data

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. From first principles, we have derived the perturbation to BPM measurements due to this effect. The theoretical framework was used to design an algorithm for signal correction that does not require knowledge of the time history of the magnetic flux being measured. Corrected signals based on that process compared favorably with the know reference signals in a laboratory calibration test sequence.

43 PARTICLE ACCELERATORS↗

Correcting Magnetic-Field Diffusion Effects in Beam Position Monitors

Beam position monitors (BPMs) provide timeresolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). The data from some types of BPMs can be influenced by magnetic field diffusion into the surrounding metal. We derive an estimate of the correction factor from first principles, and show how it is applied in practice to nearly eliminate the effect from the data.

43 PARTICLE ACCELERATORS↗

Time-Resolved Beam Position Measurements for the Scorpius Multipulse Linear Induction Accelerator

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements. Although accurate BPM measurements of beam current require correction of magnetic field diffusion, accurate measurement of beam position requires no correction. In this note, we present a theoretical derivation and the experimental validation of this result.

43 PARTICLE ACCELERATORS↗

Magnetic-Field Diffusion Effects in Beam Position Monitors III: Application to DARHT-II Beam Data

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements. Although accurate BPM measurements of beam current require correction of magnetic field diffusion, accurate measurement of beam position requires no correction. In this note, we present experimental validation of current and position results from a prototype detector employing finite conductivity sensing areas, based on experiments on the DARHT-II LIA.

43 PARTICLE ACCELERATORS↗