Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “arterial”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Exercise cardiac output following Skylab missions - The second manned Skylab mission

Cardiac output was measured during preflight and postflight exercise-stress tests on the Skylab astronauts. In the postflight tests immediately following the 28-, 59-, and 84-d earth orbital missions, the astronauts exhibited an approximate 30% decrease in cardiac output coupled with an approximate 50% decrease in cardiac stroke volume during exercise. These changes were accompanied by elevated heart rates and significant increases in total systemic peripheral vascular resistance. Mean arterial pressure was unchanged. All parameters returned to normal preflight values within 30 d of the end of the orbital period. Duration of the zero-G exposure did not appear to influence either the magnitude of the hemodynamic changes or the time-course of their return to normal. These results are discussed in relation to other cardiovascular findings and possible mechanisms responsible for the observations are outlined.

Buderer, M. C.↗

An objective determination of /+/G-sub z acceleration tolerance

The paper describes a method for objective determination of (+)G-sub z (head-to-foot) acceleration tolerance. Using noninvasive instrumentation based on a transcutaneous Doppler flow system, objective end point criteria have been developed based on measured blood flow to the head. The system consists of miniature 8 MHz Doppler sensors placed on the forehead over both frontal branches of the temporal arteries to detect blood flow velocity from backscattered ultrasound. Over 100 subjects have been studied during more than 2000 centrifuge runs

Sandler, H.↗

Intravascular bubbles associated with intravenous injections and altitude

Ultrasonically detected microbubbles were more abundant in the pulmonary artery of dogs intravenously injected with 10 ml of saline than in the same noninjected control during 10,000 ft (3,048 m), 20,000 ft (6,096 m), and 40,000 ft (12,121 m) exposures. Continuous intravenous (i.v.) drip infusions also introduced many small bubbles. Since they may serve as 'nuclei' for visible intravascular bubble formation, are sometimes associated with decompression sickness, and are additionally considered undesirable, it would appear prudent to minimize i.v. injections immediately before flights. However, a 10-min delay before ascent wil reduce their number and a 60-min delay will insure their almost complete absence. Also, slow ascent, a 1-h denitrogenation time, or use of a degassed solution will help reduce their total number.

Cooke, J. P.↗

Investigation of performance limits in axial groove heat pipes

The entrainment-shear performance limit which occurs in axial groove heat pipes was investigated and explained. In the existing heat pipe literature the entrainment heat flux limit is defined as the condition where the Weber number is greater than or equal to one. In this analysis, the critical value for the entrainment Weber number is found to be 2 pi less than or equal to 3 pi. Perhaps more important to the heat pipe designer than the entrainment performance limit is the prediction of the performance degradation due to vapor-liquid shearing stress which is also described. Preliminary qualitative experiments were conducted to observe the shear. stress wave formation phenomena. The equations presented may be used to predict and minimize the vapor-liquid shear stress performance effects that occur in axial groove and puddle flow artery heat pipes.

Feldman, K. T.↗

Digital image processing of vascular angiograms

A computer image processing technique was developed to estimate the degree of atherosclerosis in the human femoral artery. With an angiographic film of the vessel as input, the computer was programmed to estimate vessel abnormality through a series of measurements, some derived primarily from the vessel edge information and others from optical density variations within the lumen shadow. These measurements were combined into an atherosclerosis index, which was found to correlate well with both visual and chemical estimates of atherosclerotic disease.

Selzer, R. H.↗

Computer storage and retrieval of coronary trees

Coronary cineangiography is a routine procedure for evaluation of the coronary circulation. From the biplane cineangiograms a visual representation of coronary perfusion was obtained. A collection of simple ideas and procedures to aid in the collection is described. The uses to which the tree data will be put include the evaluation of myocardial function and the formation of a library sufficiently large to enable some taxonomic classification of coronary artery patterns to be made.

Starmer, C. F.↗

Computer analysis of femoral angiograms for evaluation of atherosclerosis in post-infarct males-clinical correlates

Femoral artery atheromatous lesions were studied and their changes as a measure of therapeutic effectiveness were assessed. The incidence of coronary risk factors in 100 patients was determined. Abnormal cholesterol was present in 42 percent, abnormal triglycerides in 66 percent, abnormal intravenous glucose tolerance test in 52 percent, judged from a K value of .9 or less by the technique of Wahlbert. A history of high blood pressure was present in 32 percent. Smoking was one of the most common factors.

Sanmarco, M. E.↗

Dynamic radionuclide determination of regional left ventricular wall motion using a new digital imaging device

In 47 men with arteriographically defined coronary artery disease comparative studies of left ventricular ejection fraction and segmental wall motion were made with radionuclide data obtained from the image intensifier camera computer system and with contrast cineventriculography. The radionuclide data was digitized and the images corresponding to left ventricular end-diastole and end-systole were identified from the left ventricular time-activity curve. The left ventricular end-diastolic and end-systolic images were subtracted to form a silhouette difference image which described wall motion of the anterior and inferior left ventricular segments. The image intensifier camera allows manipulation of dynamically acquired radionuclide data because of the high count rate and consequently improved resolution of the left ventricular image.

Steele, P.↗

Hemodynamic Studies of the Legs Under Weightlessness

Significant among the medical findings following prolonged space flight are reduced orthostatic tolerance and ergometric work capacity. Changes in hemodynamics of the legs with increased blood pooling and reduction in cardiac output must be considered one of the most probable causes of these effects. Concern for the above plus the observed marked tissue changes occurring in the legs during flight prompted the addition of several procedures to evaluate hemodynamic changes in the leg; resting arterial blood flow, venous compliance and muscle pumping were investigated. In so far as possible, the initial reaction to pressure in the smallest possible vein segment was examined.

William E Thornton↗

Digital image processing of vascular angiograms

The paper discusses the estimation of the degree of atherosclerosis in the human femoral artery through the use of a digital image processing system for vascular angiograms. The film digitizer uses an electronic image dissector camera to scan the angiogram and convert the recorded optical density information into a numerical format. Another processing step involves locating the vessel edges from the digital image. The computer has been programmed to estimate vessel abnormality through a series of measurements, some derived primarily from the vessel edge information and others from optical density variations within the lumen shadow. These measurements are combined into an atherosclerosis index, which is found in a post-mortem study to correlate well with both visual and chemical estimates of atherosclerotic disease.

Selzer, R. H.↗

Microvascular pressure responses of second-generation rats chronically exposed to 2 g centrifugation

Preliminary results are presented for a study aimed at a quantitative comparison of microvascular dynamics in second-generation rats reared in a 2-g force field produced by centrifugation with similar data from animals reared in a centrifuge that produced only a 1-g force. It is shown that the pressure distribution in the mesenteric microvasculature of the second generation of rats reared in a 2-g environment, as well as the animals' blood pressure response to epinephrine, are significantly different compared to their 1-g counterparts. In particular, 1-g and 2-g chronic centrifugation enhances the arterial blood pressure, and the 2-g force field attenuates the pressor effects of norepinephrine.

Richardson, D. R.↗

Tolerance of females to +Gz centrifugation before and after bedrest

Because women may be included as passengers in the proposed Space Shuttle System, experiments were conducted on 12 female subjects aged 24-35 yr to investigate the +Gz tolerance of women and the possible degradation of this tolerance after a period of weightlessness as simulated by bedrest. Over a 1-week period, each subject was exposed to +Gz levels starting at +2 Gz and increasing by 0.5 Gz increments to a gray-out point. This point was determined by peripheral vision loss with a standard lightbar and by reverse blood flow in the temporal artery. Ultimately, each woman was subjected to three runs at the +3 Gz level for about 55 min long each, separated by 5-min rest periods. Eight subjects with the best tolerance times were selected for 14 days of bedrest in a horizontal position; the other four being ambulatory controls. Tests before bedrest, immediately following, and 5 d later showed that average +Gz tolerance decreased by 67% after bedrest.

Newsom, B. D.↗

Excess liquid in heat-pipe vapor spaces

A mathematical model is developed of excess liquid in heat pipes that is used to calculate the parameters governing the axial flow of liquid in fillets and puddles that form in vapor spaces. In an acceleration field, the hydrostatic pressure variation is taken into account, which results in noncircular meniscus shapes. The two specific vapor-space geometries considered are circular and the 'Dee-shape' that is formed by a slab wick in a circular tube. Also presented are theoretical and experimental results for the conditions under which liquid slugs form at the ends of the vapor spaces. These results also apply to the priming of arteries.

Eninger, J. E.↗

Investigation of counterflow shear effects in heat pipes

The entrainment-shear performance limit in heat pipes is investigated. The entrainment heat flux limit is defined as the condition where the Weber number is greater than or equal to one. In this analysis, the critical value for the entrainment Weber number is between 2pi and 3pi. Performance degradation due to vapor-liquid shearing stress is predicted. Preliminary qualitative experiments were conducted to observe the shear stress wave formation phenomena. The equations presented may be used to predict and minimize the vapor-liquid shear stress performance effects in axial groove and puddle flow artery heat pipes.

Feldman, K. T., Jr.↗

On-orbit performance of the 12 GHz, 200 watt transmitter experiment package for CTS

Performance characteristics from on-orbit tests of the Transmitter Experiment Package (TEP) for the Communications Technology Satellite (CTS) are presented. The TEP consists of a Power Processing System (PPS), an Output Stage Tube (OST), and a Variable Conductance Heat Pipe System (VCHPS), all of which are described. The OST is a coupled-cavity traveling-wave tube with a multistage depressed collector and a stepped velocity-tapered slow-wave structure for efficiency enhancement. It has an RF output power of 240 W and an overall efficiency of 51.5% at a center band frequency of 12.080 GHz. The PPS provides the required operating voltages, regulation, control, and protection for the OST. It has a measured dc-dc conversion efficiency of 86.5% to 88.5%. The VCHPS consists of a fin radiator and three dual-artery stainless steel heat pipes using methanol and a mixture of inert gases. Test results presented include efficiencies, RF output power, frequency response, and performance with single and multiple (two) carriers frequency-modulated by video signals.

Alexovich, R. E.↗

Dip-molded t-shaped cannula

Cannula, fabricated out of polyetherurethane, has been designed for long-term service. Improved cannula is T-shaped to collect blood from both directions, thus replacing two conventional cannulas that are usually required and eliminating need for large surgical wound. It is fabricated by using dip-molding process that can be adapted to other elastomeric objects having complex shapes. Dimensions of cannula were chosen to optimize its blood-flow properties and to reduce danger of excessive clotting, making it suitable for continuous service up to 21 days in vein or artery of patient.

Broyles, H. F.↗

Cardiovascular studies in the rhesus monkey

Criteria are given for selecting the macaca mulatta as the analogue of the human in the study of cerebral circulation, particularly the control of the cerebral vascular bed during normal and stressful conditions. Topics discussed include surgical preparation of subject; responses to changes in arterial pressure, oxygen, and carbon dioxide; innervation of cerebral vessels; cerebral flow response to acceleration; and cerebral blood flow and cerebellar stimulation.

Stone, H. L.↗

Performance of the 12GHz, 200 watt transmitter experiment package for the Hermes satellite

Performance characteristics from on-orbit tests of the Transmitter Experiment Package (TEP) for the Hermes Satellite are presented. The TEP consists of a Power Processing System (PPS), an Output Stage Tube (OST) and a Variable Conductance Heat Pipe System (VCHPS), all of which are described. The OST is a coupled-cavity Traveling Wave Tube (TWT) with a Multistage Depressed Collector (MDC) and a stepped velocity-tapered slow wave structure for efficiency enhancement. It has an RF output power of 233 watts and overall efficiency of 50.75 percent at a center band frequency of 12.080 GHz. The PPS provides the required operating voltages, regulation, control and protection for the OST. The VCHPS consists of a fin radiator and three dual-artery stainless steel heat pipes using methanol and a mixture of inert gases. Test results presented include efficiencies, RF output power and body current. A discussion of thermal anomalies which occurred is presented.

Alexovich, R. E.↗