Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “and testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Test and Analysis Correlation of Standard and Hybrid Standard/Thin-ply Composite Notched Test Specimens

Hybrid composite laminates, a combination of standard-and thin-ply layers, are structurally efficient and can offer opportunities for weight savings over composite laminates composed of only standard-thickness plies. Three hybrid laminates and three standard laminates were tested and analyzed to provide a baseline comparison for not only weight savings and strength benefits of the hybrid stacking sequences, but also to provide fidelity for progressive failure modeling techniques using the two different laminate designs. The standard and hybrid composite specimens were designed to have the same thickness and in-plane stiffness properties, as closely as possible, and were loaded with axial tension and axial compression. Small notched specimens were tested under compression and tension loading, and larger intermediate specimens were tested under tension loading, only. The finite element modeling represented the as-designed panel dimensions as well as the real-life testing conditions through various boundary conditions. The progressive failure modeling and analysis technique described, exhibited very good correlation with the hybrid test specimens, and therefore is appropriate for use in future investigations into more appealing stacking sequences. The progressive failure modeling can also be used to determine the proper usage of thin-ply materials in order to determine the most ideal strength benefits over their standard-ply counterparts.

Alana Zahn↗

Evaluation of CFD as a Surrogate for Wind-Tunnel Testing: Experimental Uncertainty Quantification for the UPWT Flow Survey Test

A series of wind tunnel tests are being performed at the Unitary Plan Wind Tunnel (UPWT)at NASA Langley Research Center to assess the validity of using computational fluid dynamics(CFD) as a surrogate for wind tunnel testing. In order to make proper comparisons, uncertainties in CFD results and experimental data must be well understood. The material presented highlights the methods, assumptions, and inputs used to achieve experimental uncertainty estimates. Results for a small subset of tunnel conditions and variables of interest from the first test in the series, the Flow Survey Test, are highlighted and sample CFD comparisons are shown. The bulk of the results from this work are used for comparisons in other AIAA conference papers related to this test series.

Erin P Hubbard↗

Managing Spacecraft Risk With Space Environments Testing Via Process Safety Management At The NASA Neil A. Armstrong Test Facility

The NASA Glenn Research Center’s Neil A. Armstrong Test Facility (GRC-ATF) is home to several unique, world class aerospace test facilities, including the In-Space Propulsion (ISP) Facility. The ISP Facility is NASA’s largest chamber designed to store and transfer large quantities of liquid hydrogen and liquid oxygen; and is designed to support developmental testing of upper stage chemical propulsion systems as well as fully integrated stages. The facility is also capable of providing thermal-vacuum simulation services to support testing of aerospace hardware, Cryogenic Fluid Management (CFM) systems and other In-Space propulsion programs. The U.S. Occupational Safety and Health Administration’s (OSHA) Process Safety Management (PSM) of Highly Hazardous Chemicals Standard (29 CFR 1910.119) is an analytical tool focused on preventing the release of chemicals and other energy sources. In a short timeframe, GRC-ATF was required to restore a PSM Program at the Facility. Although the summarized work is specific to the ground testing of rockets and space vehicles, the ISP Facility is used to verify system level requirements, some of these are safety requirements, and thus key to managing risks in space.

Safety↗

Managing Spacecraft Risk with Space Environments Testing via Process Safety Management at the NASA Neil A. Armstrong Test Facility (GRC-ATF)

The NASA Glenn Research Center’s Neil A. Armstrong Test Facility (GRC-ATF) is home to several unique, world class aerospace test facilities, including the In-Space Propulsion (ISP) Facility. The ISP Facility is NASA’s largest chamber designed to store and transfer large quantities of liquid hydrogen and liquid oxygen; and is designed to support developmental testing of upper stage chemical propulsion systems as well as fully integrated stages. The facility is also capable of providing thermal-vacuum simulation services to support testing of aerospace hardware, Cryogenic Fluid Management (CFM) systems and other In-Space propulsion programs. The U.S. Occupational Safety and Health Administration’s (OSHA) Process Safety Management (PSM) of Highly Hazardous Chemicals Standard (29 CFR 1910.119) is an analytical tool focused on preventing the release of chemicals and other energy sources. In a short timeframe, GRC-ATF was required to restore a PSM Program at the Facility. Although the summarized work is specific to the ground testing of rockets and space vehicles, the ISP Facility is used to verify system level requirements, some of these are safety requirements, and thus key to managing risks in space.

Safety↗

Aluminum Stabilized NbTi Conductor Test Coil Design, Fabrication, and Test Results

A new generation of precision muon conversion experiments is planned at both Fermilab and KEK. These experiments will depend upon a complex set of solenoid magnets for the production, momentum selection and transport of a muon beam to a stopping target, and for tracking detector momentum analysis of candidate conversion electrons from the target. Baseline designs for the production and detector solenoids use NbTi cable that is heavily stabilized by an extruded high RRR aluminum jacket. A U.S.-Japan research collaboration has begun whose goal is to advance the development of optimized Al-NbTi conductors, gain experience with the technology of winding coils from this material, and test the conductor performance as modest length samples become available. For this purpose, a 'conductor test' solenoid with three coils was designed and built at Fermilab. A sample of the RIKEN Al-NbTi conductor from KEK was wound into a 'test' coil; this was sandwiched between two 'field' coils wound from doubled SSC cable, to increase the peak field on the RIKEN test coil. All three solenoid coils were epoxy impregnated, and utilized aluminum outer bandage rings to apply preload to the coils when cold. The design and fabrication details, and results of the magnet quench performance tests are presented and discussed.

43 PARTICLE ACCELERATORS↗

Integrated circuit test-port architecture and method and apparatus of test-port generation

A method and apparatus are provided for generating RTL code for a test-port interface of an integrated circuit. In an embodiment, a test-port table is provided as input data. A computer automatically parses the test-port table into data structures and analyzes it to determine input, output, local, and output-enable port names. The computer generates address-detect and test-enable logic constructed from combinational functions. The computer generates one-hot multiplexer logic for at least some of the output ports. The one-hot multiplexer logic for each port is generated so as to enable the port to toggle between data signals and test signals. The computer then completes the generation of the RTL code.

97 MATHEMATICS AND COMPUTING↗

OSU High Temperature Test Facility Test Acceptance Report, PG-29 Low Power (<350kW) Double Ended Inlet-Outlet Crossover Duct Break, Hybrid Heater

Test Acceptance Report for Test PG-29 at the Oregon State University High Temperature Test Facility. The purpose of this test is to examine the progression of the Double Ended Inlet-Outlet Crossover Duct Break transient in an integral test facility scaled to General Atomics’ Modular High Temperature Gas Reactor (MHTGR) design.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

State-of-the-art of non-destructive testing methods and technologies for application to nuclear power plant safety-related concrete structures

The inspection of nuclear power plant concrete structures presents challenges different from conventional civil engineering structures. Wall thicknesses can be in excess of one meter and the structures often have increased steel reinforcement density with more complex detailing. The accessibility for any testing method may be limited due to the presence of liners and other components and there can be a number of penetrations or cast-in-place items present. The objective of the report is to present the state-of-the art of non-destructive testing methods and technologies for the inspection of thick, heavily-reinforced nuclear power plant concrete cross-sections with particular respect to: •locating steel reinforcement and identification of its cover depth •locating tendon ducts and identification of the condition of the grout materials •detection of cracking, voids, delamination, and honeycombing in concrete structures •detection of inclusions of different materials or voids adjacent to the concrete side of the containment liner •methods capable of identification of corrosion occurrence on the concrete side of the containment liner.

42 ENGINEERING↗

Field-Aging Test Bed for Behind-the-Meter PV + Energy Storage

Small DC-coupled battery test systems are deployed at the National Renewable Energy Laboratory to evaluate capacity fade models and report on performance parameters such as round-trip efficiency under indoor and outdoor deployment scenarios. Initial commercial battery products include LG Chem RESU lithium-ion (Li-ion) and Avalon vanadium redox flow batteries. Adapting indoor lab-scale test methods to outdoor systems has challenges, including maintaining constant temperature and fully controlling batteries through standard discharge curves. Initial measurements show the Li-ion battery systems performing within expectations, near 85% round-trip efficiency. Initial lifetime modeling and measurements indicate that battery capacity could degrade by 20%-35% over 10 years at current rates.

14 SOLAR ENERGY↗

High-throughput cancer hypothesis testing with an integrated PhysiCell-EMEWS workflow

BackgroundCancer is a complex, multiscale dynamical system, with interactions between tumor cells and non-cancerous host systems. Therapies act on this combined cancer-host system, sometimes with unexpected results. Systematic investigation of mechanistic computational models can augment traditional laboratory and clinical studies, helping identify the factors driving a treatment's success or failure. However, given the uncertainties regarding the underlying biology, these multiscale computational models can take many potential forms, in addition to encompassing high-dimensional parameter spaces. Therefore, the exploration of these models is computationally challenging. We propose that integrating two existing technologiesone to aid the construction of multiscale agent-based models, the other developed to enhance model exploration and optimizationcan provide a computational means for high-throughput hypothesis testing, and eventually, optimization.ResultsIn this paper, we introduce a high throughput computing (HTC) framework that integrates a mechanistic 3-D multicellular simulator (PhysiCell) with an extreme-scale model exploration platform (EMEWS) to investigate high-dimensional parameter spaces. We show early results in applying PhysiCell-EMEWS to 3-D cancer immunotherapy and show insights on therapeutic failure. We describe a generalized PhysiCell-EMEWS workflow for high-throughput cancer hypothesis testing, where hundreds or thousands of mechanistic simulations are compared against data-driven error metrics to perform hypothesis optimization.ConclusionsWhile key notational and computational challenges remain, mechanistic agent-based models and high-throughput model exploration environments can be combined to systematically and rapidly explore key problems in cancer. These high-throughput computational experiments can improve our understanding of the underlying biology, drive future experiments, and ultimately inform clinical practice.

Agent-based model↗

Fracture Sustainability Test, Pre- and Post-Test Photomicrographs

The primary objective of this research is to understand how different rock types, mineral and fluid compositions, and fracture surface textures determine the longevity of fracture apertures, so that selection of reservoir rock can be economically optimized to reduce future refracturing. We are performing laboratory tests to study this in a custom apparatus at conditions relevant to EGS, with temperatures up to 250 degrees C (design maximum 300 degrees C). Our approach is to perform a number of long term (up to several months) laboratory experiments using relevant rock samples with different mineralogies to explore fracture sustainability under EGS conditions. We use an apparatus that allows direct application of a normal force on the fracture faces of a single fracture in a sample having a sheared, tensile fracture. We flow brine of a specified composition through the aperture, and simultaneously measure the fracture permeability and closure. We collect the effluent water for chemical and isotopic analysis. We are numerically modeling our tests and comparing experimental and numerical results. This submission includes photomicrographs of pre-test (unreacted) and post-test (reacted) samples from Brady well BCH-03 at various depths, Desert Peak well DP 35-13, and samples of Stripa granite. The photomicrographs are provided using uncrossed and crossed polarized light (xpl). UN is uncrossed nicols, CN and xpl are crossed nicols (crossed polars). The magnification listed is just referring to the objective lens that was used, not the total magnification of the images. With a 5x objective, the bottom dimension of an image is 1.75 mm. With 10x the bottom dimension of an image is 0.875 mm, and with 2x the bottom dimension of an image is 4.375 mm.

15 GEOTHERMAL ENERGY↗

Formal Functional Test Designs with a Test Representation Language

This article discusses the application of the Category-Partition Method to the test design phase. The method provides a formal framework for reducing the total number of possible test cases to a minimum logical subset for effective testing. An automatic tool and a formal language have been developed to implement the method and produce the specification of test cases

software↗

Application-level regression testing framework using Jenkins

Monitoring and testing for regression of large-scale systems such as the NCSA's Blue Waters supercomputer are challenging tasks. In this paper, we describe the solution we came up with to perform those tasks. The goal was to find an automated solution for running user-level regression tests to evaluate system usability and performance. Jenkins, an automation server software, was chosen for its versatility, large user base, and multitude of plugins including collecting data and plotting test results over time. We also describe our Jenkins deployment to launch and monitor jobs on remote HPC system, perform authentication with one-time password, and integrate with our LDAP server for its authorization. We show some use cases and describe our best practices for successfully using Jenkins as a user-level system-wide regression testing and monitoring framework for large supercomputer systems.

97 MATHEMATICS AND COMPUTING↗

Increased prevalence of essential hypertension in areas previously exposed to fallout due to nuclear weapons testing at the Semipalatinsk Test Site, Kazakhstan

Highlights: • Large territories of Kazakhstan were exposed to radiation due to nuclear tests. • Nuclear tests lead to long-term exposure of the population in the low dose range. • There is an association between environmental radiation exposure and hypertension. • Screening allows us to diagnose CVD in the irradiated people in the early stages. • Radiation health effects should be considered in health services planning. This study examines the association between environmental radiation exposure and essential hypertension in a series of investigated geographical districts adjacent to the Semipalatinsk nuclear test site in Kazakhstan. The sample consists of 2000 volunteers participants in screening examinations in three administrative districts close to the nuclear test site, which was carried out as part of the Government Programs on Environmental Health Hazard. The cross-sectional study compares prevalence ratios in a population sample with long-term exposure in the low and intermediate dose range. Age-adjusted odds ratios for hypertension were found significantly increased with higher exposure groups. After accounting for main cardiovascular risk factors into the model and stratifying by gender, the prevalence odds ratios for radiation remained significantly increased, with a significant dose-response effect observed for some but not all subgroups. The results support existing evidence of cardiovascular health effects of radiation exposure and of persisting environmental health issues that require attention in both epidemiological surveys and healthcare provision.

54 ENVIRONMENTAL SCIENCES↗

Development and implementation of a portable grating interferometer system as a standard tool for testing optics at the Advanced Photon Source beamline 1-BM

We developed a portable X-ray grating interferometer setup as a standard tool for testing optics at the Advanced Photon Source (APS) beamline 1-BM. The interferometer can be operated in phase-stepping, Moiré, or single-grating harmonic imaging mode with 1-D or 2-D gratings. All of the interferometer motions are motorized; hence, it is much easier and quicker to switch between the different modes of operation. A novel aspect of this new instrument is its designed portability. While the setup is designed to be primarily used as a standard tool for testing optics at 1-BM, it could be potentially deployed at other APS beamlines for beam coherence and wavefront characterization or imaging. Herein, the design of the interferometer system is described in detail and coherence measurements obtained at the APS 34-ID-E beamline are presented. The coherence was probed in two directions using a 2-D checkerboard, a linear, and a circular grating at X-ray energies of 8 keV, 11 keV, and 18 keV.

47 OTHER INSTRUMENTATION↗