Life and stability testing of packaged low-cost energy storage materials

Thermal cycling and performance tests, performed to verify the package integrity, life, and stability of the chub packaged materials system for storage coolness with application to residential air conditioning, are described. The moisture vapor retention characteristics of the laminate film for long term chub performance was determined. The stability, mechanical integrity, and thermal performance of chubs following mechanical shock, vibration, and temperature extremes is reported.

Frysinger, G. R.↗

Near-term hybrid vehicle program, phase 1. Appendix B: Design trade-off studies report. Volume 2: Supplement to design trade-off studies

Results of studies leading to the preliminary design of a hybrid passenger vehicle which is projected to have the maximum potential for reducing petroleum consumption in the near term are presented. Heat engine/electric hybrid vehicle tradeoffs, assessment of battery power source, and weight and cost analysis of key components are among the topics covered. Performance of auxiliary equipment, such as power steering, power brakes, air conditioning, lighting and electrical accessories, heating and ventilation is discussed along with the selection of preferred passenger compartment heating procedure for the hybrid vehicle. Waste heat from the engine, thermal energy storage, and an auxiliary burner are among the approaches considered.

Source record↗

Fuselage ventilation due to wind flow about a postcrash aircraft

Postcrash aircraft fuselage fire development, dependent on the internal and external fluid dynamics is discussed. The natural ventilation rate, a major factor in the internal flow patterns and fire development is reviewed. The flow about the fuselage as affected by the wind and external fire is studied. An analysis was performend which estimated the rates of ventilation produced by the wind for a limited idealized environmental configuration. The simulation utilizes the empirical pressure coefficient distribution of an infinite circular cylinder near a wall with its boundary later flow to represent the atmospheric boundary layer. The resulting maximum ventilation rate for two door size openings, with varying circumferential location in a common 10 mph wind was an order of magnitude greater than the forced ventilation specified in full scale fire testing. The parameter discussed are: (1) fuselage size and shape, (2) fuselage orientation and proximity to the ground, (3) fuselage-openings size and location, (4) wind speed and direction, and (5) induced flow of the external fire plume is recommended. The fire testing should be conducted to a maximum ventilation rate at least an order of magnitude greater than the inflight air conditioning rates.

Stuart, J. W.↗

Solar-Heated Public Library--Troy, Ohio

Report on installation, operation and performance of a solar-heating system installed at the Troy-Miami County Public Library in Troy, Ohio. Solar retrofit system complements passive solar-energy system and interfaces with existing heat, ventilation and air-conditioning systems.

Source record↗

Study of component technologies for fuel cell on-site integrated energy systems

Heating, ventilation and air conditioning equipment are integrated with three types of fuel cells. System design and computer simulations are developed to utilize the thermal energy discharge of the fuel in the most cost effective manner. The fuel provides all of the electric needs and a loss of load probability analysis is used to ensure adequate power plant reliability. Equipment cost is estimated for each of the systems analyzed. A levelized annual cost reflecting owning and operating costs including the cost of money was used to select the most promising integrated system configurations. Cash flows are presented for the most promising 16 systems. Several systems for the 96 unit apartment complex (a retail store was also studied) were cost competitive with both gas and electric based conventional systems. Thermal storage is shown to be beneficial and the optimum absorption chiller sizing (waste heat recovery) in connection with electric chillers are developed. Battery storage was analyzed since the system is not electric grid connected. Advanced absorption chillers were analyzed as well. Recommendations covering financing, technical development, and policy issues are given to accelerate the commercialization of the fuel cell for on-site power generation in buildings.

Lee, W. D.↗

Ozone contamination in aircraft cabins: Results from GASP data and analyses

The global atmospheric sampling program pertaining to the problem of ozone contamination in commercial airplane cabins is described. Specifically, analyses of GASP data have: confirmed the occurrence of high ozone levels in aircraft cabins and documented the ratio of ozone inside and outside the cabins of two B747 airliners, including the effects of air conditioning modifications on that ratio; defined ambient ozone climatology at commercial airplane cruise altitudes, including tabulation of encounter frequency data which were not available before GASP; and outlined procedures for estimating the frequency of flights encountering high cabin ozone levels using climatological ambient ozone data, and verified these procedures against cabin measurements.

Holdeman, J. D.↗

Ozone contamination in aircraft cabins - Results from GASP data and analyses

The paper reviews results from the NASA Global Atmospheric Sampling Program (GASP) pertaining to the problem of ozone contamination in commercial aircraft cabins. Specifically, analyses of GASP data have (1) confirmed the high ozone levels in aircraft cabins and documented the ratio of ozone inside and outside the cabins of two B747 airliners, including the effects of air conditioning modifications on that ratio; (2) defined ambient ozone climatology at commercial aircraft cruise altitudes, including tabulation of encounter frequency data; and (3) outlined procedures for estimating the frequency of flights encountering high cabin ozone levels using climatological ambient ozone data and verified these procedures against cabin measurements.

Holdeman, J. D.↗

Influence of landing gear flexibility on aircraft performance during ground roll

An analysis is made of the influence of landing gear deflection characteristics on aircraft performance on the ground up to rotation. A quasi-steady dynamic equilibrium state is assumed, including other simplifying assumptions such as calm air conditions and normal aircraft lift and drag. Ground incidence is defined as the angle made by the mean aerodynamic chord of the wing with respect to the ground plane, and equations are given for force and balance which determine the quasi-equilibrium conditions for the aircraft during ground roll. Results indicate that the landing gear deflections lead to a substantial increase in the angle of attack, and the variation in the ground incidence due to landing gear flexibility could be as much as + or - 50%, and the reduction in tail load requirements almost 25%.

Sivaramakrishnan, M. M.↗

Develop and test fuel cell powered on-site integrated total energy systems: Phase 3: Full-scale power plant development

The development of a commercially viable and cost-effective phospheric acid fuel cell powered on-site integrated energy system (OS/IES) is described. The fuel cell offers energy efficients in the range of 35-40% of the higher heating value of available fuels in the form of electrical energy. In addition, by utilizing the thermal energy generated for heating, ventilating and air-conditioning (HVAC), a fuel cell OS/IES could provide total energy efficiencies in the neighborhood of 80%. Also, the Engelhard fuel cell OS/IES offers the important incentive of replacing imported oil with domestically produced methanol, including coal-derived methanol.

Source record↗

Swirl Diffuser

Gas diffuser, based on swirling flow, dissipates incoming gas velocity in relatively short distance. Pinwheel nozzle welded to end of inlet pipe creates swirling flow. Diffuser esentially open pipe with pinwheel nozzle, pressure drop in diffuser almost same as open pipe. Applications include fuel burners in room inlets for heating and air-conditioning, and carburetors for internal-combustion engines.

Simon, W. E.↗

Heat recovery subsystem and overall system integration of fuel cell on-site integrated energy systems

The best HVAC (heating, ventilating and air conditioning) subsystem to interface with the Engelhard fuel cell system for application in commercial buildings was determined. To accomplish this objective, the effects of several system and site specific parameters on the economic feasibility of fuel cell/HVAC systems were investigated. An energy flow diagram of a fuel cell/HVAC system is shown. The fuel cell system provides electricity for an electric water chiller and for domestic electric needs. Supplemental electricity is purchased from the utility if needed. An excess of electricity generated by the fuel cell system can be sold to the utility. The fuel cell system also provides thermal energy which can be used for absorption cooling, space heating and domestic hot water. Thermal storage can be incorporated into the system. Thermal energy is also provided by an auxiliary boiler if needed to supplement the fuel cell system output. Fuel cell/HVAC systems were analyzed with the TRACE computer program.

Mougin, L. J.↗

JESS facility modification and environmental/power plans

Preliminary plans for facility modifications and environmental/power systems for the JESS (Joint Exercise Support System) computer laboratory and Freedom Hall are presented. Blueprints are provided for each of the facilities and an estimate of the air conditioning requirements is given.

Bordeaux, T. A.↗

Vortex wake alleviation studies with a variable twist wing

Vortex wake alleviation studies were conducted in a wind tunnel and a water towing tank using a multisegmented wing model which provided controlled and measured variations in span load. Fourteen model configurations are tested at a Reynolds number of one million and a lift coefficient of 0.6 in the Langley 4- by 7-Meter Tunnel and the Hydronautics Ship Model Basin water tank at Hydronautics, Inc., Laurel, Md. Detailed measurements of span load and wake velocities at one semispan downstream correlate well with each other, with inviscid predictions of span load and wake roll up, and with peak trailing-wing rolling moments measured in the far wake. Average trailing-wing rolling moments are found to be an unreliable indicator of vortex wake intensity because vortex meander does not scale between test facilities and free-air conditions. A tapered-span-load configuration, which exhibits little or no drag penalty, is shown to offer significant downstream wake alleviation to a small trailing wing. The greater downstream wake alleviation achieved with the addition of spoilers to a flapped-wing configuration is shown to result directly from the high incremental drag and turbulence associated with the spoilers and not from the span load alteration they cause.

Holbrook, G. T.↗

HVAC modifications and computerized energy analysis for the Operations Support Building at the Mars Deep Space Station at Goldstone

The key heating, ventilation, and air-conditioning (HVAC) modifications implemented at the Mars Deep Space Station's Operation Support Building at Jet Propulsion Laboratories (JPL) in order to reduce energy consumption and decrease operating costs are described. An energy analysis comparison between the computer simulated model for the building and the actual meter data was presented. The measurement performance data showed that the cumulative energy savings was about 21% for the period 1979 to 1981. The deviation from simulated data to measurement performance data was only about 3%.

Halperin, A.↗

Hovering model helicopter rotor testing

A relatively large test chamber, chosen to minimize room interference effects during helicopter hovering rotor tests, was found in initial operations to exhibit large, random variations of thrust, torque, and blade flapping. The source of these problems, unsteady recirculation of test chamber flow, was addressed by the addition of a 'flow straightener' that reduced these parameter variations to 1.5 percent of mean values. Rotor performance was then measured outside the chamber in calm, free air conditions and compared with chamber results obtained before and after modifications. Attention is given to wake flow visualization conducted in the test chamber, as well as outside.

Piziali, R. A.↗

Applications of adaptive-wall wind tunnels

A novel processing technique for the flowfield data generated by an adaptive wall wind tunnel is presented whose basic premise is the possible undesirability of forcing such a wind tunnel to simulate free-air conditions. The concept of a 'phantom' wind tunnel is introduced for both two- and three-dimensional wind tunnels, yielding a continuous spectrum of flow fields, ranging from the original passive and ventilated configuration to a fully adaptive one. In order to implement these procedures, active control is limited to floor and ceiling surfaces.

Davis, S. S.↗