Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Radiation Testing for High-Resolution Radiation-Hardened Camera System (Final CRADA Report)

The nuclear energy industry needs higher-image quality and higher rad-hard vision systems for refueling and inspection operations that are required every 12-18 months for all operating commercial reactors. During refueling operations, the serial numbers of fuel assemblies need to be visually verified in a challenging high radiation environment with dose rates on the order of 1kGy/hr. at the top of the core (approximately 10 days after shutdown). Vega Wave Systems has developed and built a radiation hard vision system that: 1. has high radiation hardness, 2. demonstrated best in the industry image quality, 3. has small size and weight, and 4. does not suffer from radiation-induced noise. ANL-1060 (02/13/2023) The proprietary Enduray vision system from Vega Wave Systems, Inc. is designed to withstand more than 400x the radiation level of the Vidicon-based systems, currently the highest radiation tolerant system in use today. The Van De Graaff (VDG) electron accelerator at Argonne National Laboratory is ideally suited for testing of Enduray vision system. VDG provides a broad band (up to 3 MeV) x-ray source that reasonably approximates the energy and spectrum of the gamma radiation expected at the top of a nuclear core 10 days after shutdown (~1kGy/hr.), is easily controlled for variable tests, and will not activate the parts under radiation for ease of timely and close inspection and characterization of the system in case of operational issues.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Compensation of heat load deformations using adaptive optics for the ALS upgrade: a wave optics study

In this paper, a realistic wave optics simulation method has been developed to study how wavefront distortions originating from heat load deformations can be corrected using adaptive X-ray optics. Several planned soft X-ray and tender X-ray insertion-device beamlines in the Advanced Light Source upgrade rely on a common design principle. A flat, first mirror intercepts the white beam; vertical focusing is provided by a variable-line-space monochromator; and horizontal focusing comes from a single, pre-figured, adaptive mirror. A variety of scenarios to cope with thermal distortion in the first mirror are studied by finite-element analysis. The degradation of the intensity distribution at the focal plane is analyzed and the adaptive optics that correct it is modeled. The range of correctable wavefront errors across the operating range of the beamlines is reported in terms of mirror curvature and spatial frequencies. The software developed is a one-dimensional wavefront propagation package made available in the OASYS suite, an adaptable, customizable and efficient beamline modeling platform.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A field programmable gate array-based timing and control system for the dynamic compression sector

A field programmable gate array (FPGA)-based timing and trigger control system has been developed for the Dynamic Compression Sector (DCS) user facility located at the Advanced Photon Source (APS) at Argonne National Laboratory. The DCS is a first-of-its-kind capability dedicated to dynamic compression science. All components of the DCS laser shock station—x-ray choppers, single-shot shutter, internal laser triggers, and shot diagnostics—must be synchronized with respect to the arrival of x rays in the hutch. An FPGA synchronized to the APS storage ring radio frequency clock (352 MHz) generates trigger signals for each stage of the laser and x-ray shutter system with low jitter. The developed FPGA-based control system was the first system used to control the laser and the shutter system since its commissioning, and it has been developing since then to improve the timing jitter. The system is composed of a Zynq FPGA, a debug card, line drivers, and a power supply. The delay and offsets of the trigger signals can be adjusted by using a user-friendly graphical user interface with high precision. Here, the details of the system architecture, timing requirements, firmware, and software implementation along with the performance evaluation are presented in this paper. The system offers low timing jitter (15.5 ps rms) with respect to the APS 352 MHz clock, suitable for the 100 ps (FWHM) x-ray bunch duration at the APS.

47 OTHER INSTRUMENTATION↗

Impact of high-dose gamma-ray irradiation on electrical characteristics of N-polar and Ga-polar GaN p–n diodes

We investigate the impact of high-dose gamma-ray irradiation on the electrical performance of Ga-polar and N-polar GaN-based p-n diodes grown by metalorganic chemical vapor deposition. We compare the current density-voltage (J-V), capacitance-voltage (C-V), and circular transfer length method (CTLM) characteristics of the p-n diodes fabricated on Ga-polar and N-polar orientations before and after irradiation. The relative turn-on voltage increases for the Ga-polar diodes with increasing irradiation dose, while it increases initially and then starts to decrease for the N-polar diodes. The p-contact total resistance increases for Ga-polar and decreases for N-polar samples, which we attribute to the formation of point defects and additional Mg activation after irradiation. The J-V characteristics of most of the tested diodes recovered over time, suggesting the changes in the J-V characteristics are temporary and potentially due to metastable occupancy of traps after irradiation. X-ray photoelectron spectroscopy (XPS) and photoluminescence (PL) measurements reveal the existence of different types of initial defects and surface electronic states on Ga-polar and N-polar samples. Gallium vacancies (V Ga ) are dominant defects in Ga-polar samples, while nitrogen vacancies (V N ) are dominant in N-polar samples. The presence of a higher concentration of surface states on Ga-polar surfaces compared to N-polar was confirmed by calculating the band bending and the corresponding screening effect due to opposite polarization bound charge and ionized acceptors at the surface. The difference in surface stoichiometry in these two orientations is responsible for the different behavior in electrical characteristics after gamma-ray interactions.

36 MATERIALS SCIENCE↗

Laser-Produced Coherent X-ray Sources. Final report

This is the final report for the DOE-AMO DE-FG02-05ER15663 grant. Using a high-peak-power laser system at the Extreme Light Laboratory of the University of Nebraska-Lincoln, we develop novel femtosecond radiation sources and use them to investigate ultrafast photo-induced processes. Pulses of high energy electrons and x-rays are generated when an optical pulse is focused to ultra-high intensity. The radiation is used to probe the evolution of matter under highly non-equilibrium conditions with atomic-scale temporal and spatial resolution. Moreover, the facility is small enough to fit in a university laboratory and is operated by graduate students and postdocs.

74 ATOMIC AND MOLECULAR PHYSICS↗

Lipids status and copper in a single astrocyte of the rat model for amyotrophic lateral sclerosis: Correlative synchrotron-based X-ray and infrared imaging

Amyotrophic lateral sclerosis (ALS) is a fatal neurodegenerative disease, causing death of motor neurons controlling voluntary muscles. The pathological mechanisms of the disease are only partially understood. The hSOD1-G93A ALS rat model is characterized by an overexpression of human mutated SOD1, causing increased vulnerability by forming intracellular protein aggregates, inducing excitotoxicity, affecting oxidative balance and disturbing axonal transport. In this study we followed the bio-macromolecular organic composition and compartmentalization together with trace metal distribution in situ in single astrocytes from the ALS rat model and compared them to the control astrocytes from nontransgenic littermates by simultaneous use of two synchrotron radiation-based methods: Fourier transform infrared microspectroscopy (SRFTIR) and hard X-ray fluorescence microscopy (XRF). Here we show that ALS cells contained more Cu, which colocalized with total lipids, increased carbonyl groups and oxidized lipids, thus implying direct involvement of Cu in oxidative stress of lipidic components without direct connection to protein aggregation in situ.

59 BASIC BIOLOGICAL SCIENCES↗

Three-dimensional reconstruction of inertial confinement fusion hot-spot plasma from x-ray and nuclear diagnostics on OMEGA

Multidimensional effects degrade the neutron yield and the compressed areal density of laser-direct-drive inertial confinement fusion implosions of layered deuterium–tritium cryogenic targets on the OMEGA Laser System with respect to 1D radiation-hydrodynamic simulation predictions. A comprehensive physics-informed 3D reconstruction effort is under way to infer hot-spot and shell conditions at stagnation from four x-ray and seven neutron detectors distributed around the OMEGA target chamber. Neutron diagnostics, providing measurements of the neutron yield, hot-spot flow velocity, and apparent ion-temperature distribution, are used to infer the mode-1 perturbation at stagnation. The x-ray imagers record the shape of the hot-spot plasma to diagnose mode-1 and mode-2 perturbations. A deep-learning convolutional neural network trained on an extensive set of 3D radiation-hydrodynamic simulations is used to interpret the x-ray and nuclear measurements to infer the 3D profiles of the hot-spot plasma conditions and the amount of laser energy coupled to the hot-spot plasma. A 3D simulation database shows that larger mode-1 asymmetries are correlated with higher hot-spot flow velocities and reduced laser-energy coupling and neutron yield. Three-dimensional hot-spot reconstructions from x-ray measurements indicate that higher amounts of residual kinetic energy are correlated with higher measured hot-spot flow velocities, consistent with 3D simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Identification of uranium oxidation states using oxygen K-edge scanning transmission X-ray microscopy

The field of nuclear forensics is growing in importance, and the increasing capabilities at synchrotron radiation light sources enable non-destructive characterization of oxide particles with better spatial, compositional, and oxidation state speciation resolution than ever before. Here, uranium oxide particles derived from multiple wet chemical processing methods were examined using a scanning transmission X-ray microscope (STXM), and a weakly-supervised method was developed to automatically analyze the collected data. Multiple uranium oxidation states were observed and quantified within and between samples, yielding information about differences between particles produced via the various processing routes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

VERITAS : A density-functional theory-based multiband kinetic model for understanding x-ray spectroscopy of dense plasmas

X-ray spectroscopy has long been a powerful diagnostic tool for hot, dilute plasmas, providing insights into plasma conditions by measuring line shifts and broadenings of atomic transitions. The technique critically depends on the accuracy of atomic physics models used to interpret spectroscopic measurements for inferring plasma properties such as free-electron density and temperature. Over the past decades, the atomic and plasma physics communities have developed robust atomic physics models to account for various processes in hot, dilute classical plasmas. While these models have been successful in that regime, their applicability becomes uncertain when interpreting x-ray spectroscopy experiments of above-solid-density plasmas. Given that finite-temperature density-functional theory (DFT) offers a more accurate description of dense plasma environments, we present the development of a DFT-based multi-band kinetic model, VERITAS, designed to improve the interpretation of x-ray spectroscopic measurements in high-density plasmas produced by laser-driven spherical implosions. This work details the VERITAS model and its application to both time-integrated and time-resolved x-ray spectra from implosion experiments on OMEGA. The advantages and limitations of the VERITAS model will also be discussed, along with potential directions for advancing x-ray spectroscopy of dense and superdense plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of silicon and indium gallium arsenide photodiodes as direct timing detectors for pulsed x-ray systems

Benchtop pulsed x-ray systems are commonly used to record dynamic material data on the order of nanoseconds, but pulse timing is often difficult to accurately determine. This study demonstrates that commercially available photodiodes can be used effectively for direct x-ray pulse detection without the need for visible light scintillators. X-ray pulses from four commercially available flash x-ray systems were quantified using one silicon and two indium gallium arsenide (InGaAs) photodiodes. The measured InGaAs pulse durations were strongly dependent on radiation dose in the non-linear operating regime, so the photodiodes were shielded to operate below the 2.5 V non-linear regime threshold. The average pulse duration and pulse arrival time jitter of the photodiodes for each x-ray source were within several nanoseconds with the exception of two sets of measurements that were affected by low instrument sensitivity and electrical noise. These results show that InGaAs photodiodes can be used as effective and repeatable stand-alone timing diagnostics for x-ray pulses as short as 20 ns or less.

47 OTHER INSTRUMENTATION↗

Neural network methods for radiation detectors and imaging

Recent advances in image data proccesing through deep learning allow for new optimization and performance-enhancement schemes for radiation detectors and imaging hardware. This enables radiation experiments, which includes photon sciences in synchrotron and X-ray free electron lasers as a subclass, through data-endowed artificial intelligence. We give an overview of data generation at photon sources, deep learning-based methods for image processing tasks, and hardware solutions for deep learning acceleration. Most existing deep learning approaches are trained offline, typically using large amounts of computational resources. However, once trained, DNNs can achieve fast inference speeds and can be deployed to edge devices. A new trend is edge computing with less energy consumption (hundreds of watts or less) and real-time analysis potential. While popularly used for edge computing, electronic-based hardware accelerators ranging from general purpose processors such as central processing units (CPUs) to application-specific integrated circuits (ASICs) are constantly reaching performance limits in latency, energy consumption, and other physical constraints. These limits give rise to next-generation analog neuromorhpic hardware platforms, such as optical neural networks (ONNs), for high parallel, low latency, and low energy computing to boost deep learning acceleration (LA-UR-23-32395).

edge computing↗

Radiation hardness of the low gain avalanche diodes developed by NDL and IHEP in China

This paper presents a study on the radiation hardness of low gain avalanche detector (LGAD) developed by the Novel Device Laboratory (NDL) in Beijing and the Institute of High Energy Physics (IHEP) of Chinese Academy of Sciences, in the context of an upgrade project of the ATLAS detector for the high luminosity phase of LHC. NDL LGAD sensors with different layouts, epitaxial resistivity and doping profile were irradiated up to 1.02 × 10 15 n eq /cm 2 by 70 MeV protons at Cyclotron and Radioisotope Center (CYRIC). The timing resolution of NDL LGAD sensors reached 50 ps and the collected charge reached 3 - 4 fC after irradiation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nano-laminography with a transmission X-ray microscope

Nano-laminography combines the penetrating power of hard X-rays with a tilted rotational geometry to deliver high-resolution, three-dimensional images of laterally extended, flat specimens that are otherwise incompatible with, or difficult to image using, conventional nano-tomography. In this work, we demonstrate a full-field, X-ray nano-laminography system implemented with the transmission X-ray microscope at beamline 32-ID of the upgraded Advanced Photon Source at Argonne National Laboratory, USA. By rotating the sample around an axis inclined by 20° to the incident beam, the technique minimizes the long optical path lengths that would otherwise generate excessive artifacts when planar samples are imaged edge-on. The efficiency of the technique is demonstrated with 50 nm spatial resolution and minute-scale temporal resolution 3D imaging of a planar integrated circuit sample and targeted imaging of an individual particle within a powder sample, where mounting procedures are typically challenging in regular nano-tomography. The sample mounting strategy, data acquisition, and reconstruction method will also be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultrafast time-resolved x-ray absorption spectroscopy of ionized urea and its dimer through ab initio nonadiabatic dynamics

Investigating the early dynamics of chemical systems following ionization is essential for our understanding of radiation damage. However, experimental as well as theoretical investigations are very challenging due to the complex nature of these processes. Time-resolved x-ray absorption spectroscopy on a femtosecond timescale, in combination with appropriate simulations, is able to provide crucial insights into the ultrafast processes that occur upon ionization due to its element-specific probing nature. In this theoretical study, we investigate the ultrafast dynamics of valence-ionized states of urea and its dimer employing Tully's fewest switches surface hopping approach using Koopmans' theorem to describe the ionized system. We demonstrate that following valence ionization through a pump pulse, the time-resolved x-ray absorption spectra at the carbon, nitrogen, and oxygen K-edges reveal rich insights into the dynamics. Excited states of the ionized system give rise to time-delayed blueshifts in the x-ray absorption spectra as a result of electronic relaxation dynamics through nonadiabatic transitions. Moreover, our statistical analysis reveals specific structural dynamics in the molecule that induce time-dependent changes in the spectra. For the urea monomer, we elucidate the possibility to trace effects of specific molecular vibrations in the time-resolved x-ray absorption spectra. For the urea dimer, where ionization triggers a proton transfer reaction, we show how the x-ray absorption spectra can reveal specific details on the progress of proton transfer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Versatile multi-energy hard x-ray camera to study confined and unconfined fast electron dynamics and anisotropies (Invited)

A powerful and flexible hard x-ray (HXR) camera has been recently installed and tested on the WEST tokamak (CEA, France) in collaboration with the Princeton Plasma Physics Laboratory. The diagnostic is a pinhole camera fielded with a 2D pixel detector equipped with a 1 mm thick CdTe sensor. The novelty of this diagnostic technique is the detector’s capability of adjusting the threshold energy at the pixel level. This innovation provides great flexibility in the energy configuration, allowing simultaneous space, energy, and time resolved x-ray measurements. The novel camera has been used to measure the core radiation from non-Maxwellian (fast) electrons accelerated by Lower Hybrid (LH) waves and also the beam–target emission of tungsten in the divertor region produced by fast electron losses interacting with the target. In addition, anisotropic hard x-ray emission has been detected for the first time at the WEST core and edge plasma, with opposite toroidal intensity trends. Finally, experimental vertical and toroidal HXR profiles have been successfully reproduced with the LH code LUKE.

47 OTHER INSTRUMENTATION↗