Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Washington”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AP Tank Farm Exhauster Slipstream (Volume 1)

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the Hanford AP tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing on a slipstream from the Hanford AP tank exhauster was conducted on March 23-24, 2018. This testing focused on both APR and PAPR cartridges. Previous testing of APR cartridges was conducted on the AP exhauster in June of 2016. However, an AP exhauster upgrade was completed in September 2016. In the most recent testing, slipstream vapors from the new AP exhauster were fed to two respirator cartridge test stands, one for the PAPR respirator cartridges and the other for the APR respirator cartridges. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—were also tested consecutively over the same two days as the APR cartridge tests, using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sources of Propane Consumed in California

Project Scope: The objective of this study is to specify the sources of propane consumed in California. It answers the questions, where does the propane used in California come from and how was it produced? The results of this study provide comprehensive, transparent, and verifiable estimates, based on the 2018 market. The information provided in this report is suitable for use to assess the life cycle carbon intensity of propane used as a transportation fuel in California. As the 2009 Low Carbon Fuel Standard (LCFS) aims to reduce California’s greenhouse gas (GHG) emissions and other smog-forming and toxic air pollutants, the appropriate designation of carbon intensity for propane as a transportation fuel is important for evaluating propane’s potential to contribute to GHG goals and understandings in the context of various actions. This study focuses on estimating the shares of total propane consumed in the state of California produced from petroleum refineries, natural gas plants, and bituminous sands sources inside California and elsewhere. Results: An estimated 590 million gallons of propane were consumed in California in 2018, of which, 59.5% originated from refinery production and 40.5% originated from natural gas plants. The majority of this was sourced from refinery production in California, 334 million gallons. Most of the propane imported to California for consumption was sourced from natural gas plants, 113 million gallons, with over half of the imported volume sourced from Canada. The volume sourced from bituminous sand upgrader and fractionator operations was negligible. Details from this analysis are presented in the table below which provides an overview of the propane flows estimated in this study by region and production method. The shares and volumes presented here represent a snapshot for 2018. A significant increase in propane demand, such as could be caused by increased use of propane as a transportation fuel in the state, would affect California’s propane production, imports, and exports. The method and data sources used for the estimates provided in this report also provide the framework which could be used for future updates. Key Method Considerations: The values presented here are based on a two-step approach where the first step was to determine the flows of propane into and out of California from different regions and the second step was to estimate the propane production methods in each region. A volume balance approach is used as the primary method for tracking the volume of propane in and out of California as propane production and import volumes are available by Petroleum Administration of Defense District (PADD) from EIA and neither inter-PADD propane transfers nor state-specific non-prime supplier consumption are available from a public data source. The volume balance performed for this study covered PADD 5 (the West Coast), which includes Arizona, California, Nevada, Oregon, and Washington. The volume balance used all available public datasets to determine propane production, imports, exports, and consumption. Volumes unaccounted for by these datasets were estimated using the resulting volume balance by assuming market equilibrium. Consumption within each state in PADD 5 was estimated based on known import, export, and production volumes and this amount was used to develop the volume balance. EIA only tracks consumption at the state level by prime supplier sales. The volume balance approach provides the basis to correct for additional propane consumed in-states where propane is transferred to California. To determine the California propane sources and trade in 2018. volume of propane consumed in California, the volume balance approach is again used where it was estimated all imported volumes not specifically flagged for re-export were consumed, and the remaining consumption was produced in-state. The California Energy Commission (CEC) provided the total volume of propane imported and exported from California in 2018; this volume data set along with commodity tracking from the Canada Energy Regulator (CER) and the International Trade Commission (ITC) which tracks port of entry and final destination was used to determine where propane originated from and where it was ultimately consumed. For example, the CER tracks propane leaving Canada and entering each state within the U.S. Imported propane from Canada to California – marked for California – is assumed to be consumed in California. When no further data were available, import volumes were assumed to be consumed in California without pass-through (i.e., no propane imported to California was directly sold and exported). In most cases, the production method for each propane source region was applied to the volume of propane transferred to California. In other words, the shares of propane sourced from natural gas and refineries for each production region was assigned to California imports based on their contribution to the total volume flows into California to determine the production method for propane consumed in-state. For volumes imported into California from PADD 4, Washington State, Canada, and the rest of the world (Argentina, Chile, Norway, Peru, South Korea, and Trinidad and Tobago), the volumes sourced from petroleum refineries and natural gas plants reflect the either production ratio for the region or, in cases where the sources specific to the amounts exported to California could be determined, the sources specific to the volumes transferred to California.

03 NATURAL GAS↗

Analysis of Respirator Cartridge Performance Testing on Hanford Tank A-101

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors emanating from the headspace of tank A-101 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules.[3] Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted over a period from July 22-24, 2016, using headspace vapors from Hanford tank A-101 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days with A-101 headspace vapors. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. Key conclusions from the assessment of the 59 COPCs in this study are described below: • Based on d measured cartridge inlet vapor concentrations from tank A-101 headspace, both ammonia and N-Nitrosodimethylamine (NDMA) exceeded their Occupational Exposure Limits (OEL).3 These measurements were generally consistent with maximum A-101 headspace measurements previously obtained for these two compounds. • Ammonia had respirator cartridge outlet concentrations that exceeded 10% of the OEL for both cartridges tested, indicating breakthrough for each. For the SCOTT 7422-SD1 cartridge, ammonia appeared to breakthrough above 10% of its OEL after 2 hours. For the SCOTT 7422-SC1 cartridge, ammonia breakthrough appeared to occur after 8 hours. 1 “Adequate performance” refers to the breakthrough criteria used in this analysis—that is, sustained cartridge outlet concentrations above 10% of the OEL. For some COPCs, an alternate threshold has been applied when necessary due to higher detection limit (DL)/reporting limit (RL) values for specific compounds. Ultimately, Industrial Hygiene professionals will use these results along with specific hazard assessments to determine service life and cartridge use that provides the necessary performance. 2 These tests were conducted under static conditions absent waste-disturbing activities in the subject tank or tank farm. 3 Occupational Exposure Limits accepted for Hanford Tank Farm use are based on OELs established by a U.S. governmental agency or national professional organization (e.g., OSHA, National Institute for Occupational Safety and Health, American Conference of Governmental Industrial Hygienists), or if no U.S. OEL exists, standard toxicological practices are applied to develop OELs using non-U.S. exposure limits, other established OELs for chemical surrogates when available, or other standard procedures. The OEL for NDMA was established in 2005 based on the MAK (Maximale Arbeitsplatzkonzentration) Commission standard adopted in Europe. iv • Despite respirator inlet measurements for NDMA that were in excess of its OEL, all corresponding outlet measurements, from both respirator cartridges, were below analytical DL 1 for the

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AP Tank Farm Exhauster Slipstream: Volume 2 Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used at Hanford Tank Farms to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. The Occupational Safety and Health Administration (OSHA) Standard promulgated in Title 29 of the Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life.[2-5] The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. Volume 1 of this report summarizes data analysis of APR and PAPR cartridge testing on vapors from the AP tank farm exhauster. Previous testing of APR cartridges was conducted on the AP exhauster in June 2016. However, an AP exhauster upgrade was completed in September 2016. Two different APR cartridges from SCOTT Safety (Monroe, North Carolina) were assessed for the new AP exhauster source, along with two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota). Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Air-Purifying Respirator (APR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104 (Vol.1)

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford tanks SX-101 and SX-104. The Occupational Safety and Health Administration (OSHA) considers cartridge testing a valid approach for establishing cartridge change schedules.2 Testing is commonly applied in situations where mixtures of COPCs exist and where other approaches such as manufacturer recommendations and modeling are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 16-17, 2017, and June 23-24, 2017, using headspace vapors from Hanford tank SX-104 and Hanford tank SX-101, respectively. Headspace vapors under static conditions were fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and subsequently were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Bridge Seismic Screening Tool (BSST), Version 2.0

The Regional Resiliency Assessment Program (RRAP) is a cooperative assessment of specific critical infrastructure within a designated geographic area and a regional analysis of the surrounding infrastructure that addresses a range of infrastructure resilience issues that could have regionally and nationally significant consequences. In 2018, DHS’s Cybersecurity and Infrastructure Security Agency (CISA) sponsored the Oregon Transportation Systems RRAP project in coordination with the Office of the Governor (under the oversight of the state resilience officer), the Oregon Office of Emergency Management (OEM), the Oregon Department of Transportation (ODOT), and other regional stakeholders (CISA 2021). This project focuses on assessing the impacts of a Cascadia Subduction Zone (CSZ) earthquake on state transportation systems and, in particular, how those impacts may affect the ability of emergency response efforts to move supplies into the region. The intended outcome of this analysis is the prioritization of transportation routes and modes for additional planning, investment, hardening, or other activities to enhance their resilience—and therefore, to enhance their ability to support response and recovery efforts following a CSZ earthquake. An important part of this transportation system-level assessment has been to assess the seismic vulnerability of the state highway system. In doing so, the RRAP project team used the Bridge Seismic Screening Tool (BSST) to assess, at a system-level, the potential impacts that a CSZ earthquake could have on state highway bridges (Bergerson et al. 2019).1 Argonne National Laboratory (Argonne), in collaboration with the Washington State Department of Transportation (WSDOT), originally developed the BSST as part of the 2017 Washington State Transportation Systems RRAP project, a sister project to the 2018 Oregon Transportation Systems RRAP project. Argonne updated the BSST during this more recent project in Oregon based on feedback from stakeholders and subject matter experts (SMEs) on the original version of the tool. The first step in the BSST is to assess the seismic vulnerability of roadway bridges following a CSZ earthquake to determine a projected or potential damage state. Damage states then help determine approximate reopening times for bridge crossings.2 This document provides details on the BSST methodology, the implementation of that tool to analyze the projected damage incurred in a CSZ earthquake scenario, and the determination of corresponding reopening times of interstate, state highway, and local bridges following such an event.

58 GEOSCIENCES↗

American Nuclear Society Panel: Working in Nuclear Abroad

This brief 10-15 minute presentation will introduce the ........... 2021 ANS Winter Meeting and Technology Expo - November 30–December 3, 2021 - Now all sessions will be available virtually! - Washington, DC| Washington Hilton - https://www.ans.org/meetings/wm2021/

99 GENERAL AND MISCELLANEOUS↗

FY2021 ILAW Glass Ion-Exchange Rate Testing

Approximately 54 to 56 million gallons of radioactive mixed waste is currently stored in underground tanks at The United States Department of Energy’s (DOE’s) Hanford site in the State of Washington. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) will provide DOE’s Office of River Protection (ORP) with a means of treating this waste by vitrification for subsequent disposal. The tank waste will be separated into low- and high-activity waste fractions, which will then be vitrified respectively into Immobilized Low Activity Waste (ILAW) and Immobilized High-Level Waste (IHLW) products. The ILAW product will be disposed of in an engineered facility – the Integrated Disposal Facility (IDF) – on the Hanford site, while the IHLW product will be directed to the national deep geological disposal facility for high-level nuclear waste. The ILAW and IHLW products must meet a variety of requirements with respect to protection of the environment before they can be accepted for disposal. To capitalize on the success of the FY19 and FY20 Atkins/VSL test results on six glasses, Washington River Protection Solutions, LLC (WRPS) has contracted with Atkins/VSL to collect IEX data on four more ILAW glasses using PFT, the results of which are the subject of the present report. The work described herein was performed according to a Test Plan that is responsive to the corresponding WRPS scope of work.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In-situ Photophysical Monitors and Corrective Algorithms for Photovoltaic Film Deposition and Rapid Thermal Processing in Scalable Roll-to-Roll Manufacturing

This project evaluated three photophysics-based approaches for in situ process monitoring of the scalable deposition of perovskite photovoltaic films. Based on stakeholder input and the results of laboratory trials and literature analysis, two techniques, angle resolved elastic light scattering (ARLS) and time-resolved photoluminescence (TRPL) were prototyped and demonstrated with a mixture of simulation, offline and online tests. Also, a hybrid gas flow and humidity control enclosure was constructed and demonstrated to stabilize the ambient conditions around the slot die deposition process and were demonstrated to meet the target humidity control in situ. Due in part to a delayed start and COVID-related lab restrictions and personnel changes, some of the milestones were not met. In spite of these challenges, however, both techniques were prototyped through several iterations and demonstrated significant promise for rapid in line perovskite characterization within the targeted characterization time windows and these techniques are under further development for use in DE-FOA000235:2357-1586. The TRPL system was fully mounted and demonstrated on the scaled slot die roll to roll and sheet coating systems at the Washington Clean Energy Testbeds (WCET). Motivated by significant internal and stakeholder interest, the successful prototyping achieved here, the ongoing need for in-situ characterization for the scale-up of perovskite manufacturing, and the benefits of in situ photophysical characterization for future funded process development research, we are continuing with the principle aims of the project to develop effect in situ photophysical probes for fast analysis of the optoelectronic and structural quality of sheet based and roll to roll process perovskites. TRPLS and ARLS probes proposed in the project are to be completed with external support from the Washington Research Foundation at the WCET. We are currently actively engaged in the acquisition of components and plan to complete and test the probes within three months. It is our intention that these probes will then be used in ongoing perovskite development with our research and commercialization partners including First Solar and other member of the US MAP consortium in future funded development work.

14 SOLAR ENERGY↗

Avista’s Shared Energy Economy Model Pilot: A Techno-economic Assessment

As part of the second round of the Washington Clean Energy Fund, Avista Corp received a $3.5 million matching grant in support of a shared energy economy project to test the integration of energy assets–from rooftop solar and battery storage to building energy management systems–that can be shared and used for multiple purposes. The goal of this project is to demonstrate how both the customer and the utility can benefit from this shared energy economy model and demonstrate that the electric grid can become more reliable, efficient, resilient, and flexible. Pacific Northwest National Laboratory was engaged by the U.S. Department of Energy and the Washington State Department of Commerce to work with Avista in assessing the benefits of the shared energy economy model. This report documents the techno-economic assessment of the shared energy economy model, including the definition of use cases and applications, collection and preparation of data and input parameters, development of modeling and optimization methods, and case studies and analysis results.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integrated Renewable Energy Systems

Pacific Northwest National Laboratory (PNNL) operates the Department of Energy’s (DOE) only dedicated marine laboratory at the PNNL-Sequim campus. PNNL is leading research in the blue economy and marine energy applications and building collaboration between DOE and multiple partners in the state of Washington and beyond. With Washington State support, the Integrated Renewable Energy System (IRES) demonstration testbed proposed here will advance research by developing and testing renewable energy production, management, and use for multiple marine applications (e.g., ocean observations, underwater vehicles, aquaculture). It will also advance energy resiliency for coastal communities by developing an integrated renewable energy test platform that will model how multiple renewable energy resources could power shoreline businesses or communities (Figure 1). The test bed will demonstrate how different renewable systems can be integrated to reduce carbon emissions and contribute to a net zero emissions site and provide lessons, controls, and protocols that will help to expand energy options for shoreline and maritime businesses. The integrated system is expected to serve as a test bed for shoreline power and ocean energy technologies for years to come.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Air-Purifying Respirator (APR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104: Volume 2 - Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. To protect workers at Hanford Tank Farms, WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used at the tank farms. The tests were conducted to determine the period of time the cartridges would provide adequate performance for APRs and PAPRs when workers are exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. Occupational Safety and Health Administration (OSHA) Standard 29 Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life. The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. This report summarizes data analysis of APR cartridge testing on headspace vapors from Hanford SX-101 and SX-104 single-shell tanks. Volume 1 of this report documents the testing, data analysis, results, conclusions, and recommendations resulting from the APR testing on SX-101 and SX-104 headspace vapors. Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks BY-108 and BY-110 Volume 1

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford BY-108 and BY-110 waste storage tanks. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge tests were conducted over two days from February 23-25, 2018, using headspace vapors from Hanford tanks BY-108 and BY-110. Headspace vapors from the BY-108 tank were fed to the PAPR respirator cartridge test stand, while vapors from the BY-110 headspace were fed to the APR respirator cartridge test stand. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Two different cartridges were assessed on each tank. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed for vapors from BY-110 using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—also were assessed for vapors from BY-108 over the same two days using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks BY-108 and BY-110 Volume 2: Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used by workers at Hanford Tank Farms to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. The Occupational Safety and Health Administration (OSHA) Standard promulgated in Title 29 of the Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life. The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. This report summarizes data analysis of APR and PAPR cartridge testing on BY-110 and BY-108 headspace vapors, respectively. Two different APR cartridges from SCOTT Safety (Monroe, North Carolina) were assessed for the BY-110 headspace vapors, and two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota)—were assessed for the BY-108 headspace vapors. Volume 1 of this report documents the testing, data analysis, results, conclusions, and recommendations resulting from the cartridge testing of vapors from the BY-110 and BY-108 headspaces. Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AX Tank Farm Exhauster Slipstream Volume 1

Washington River Protection Solutions (WRPS) conducted tests of four types of chemical cartridges for air-purifying respirators (APR) and powered air-purifying respirators (PAPR) to determine the period of time the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the Hanford AX tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing a cartridge service life. Testing is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing using vapors from a Hanford AX tank farm exhauster slipstream was conducted from August 25–27, 2017. Vapors from the exhauster slipstream were fed to two respirator cartridge test stands developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Four different cartridges were assessed. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using an APR cartridge test stand. Multipurpose PAPR cartridges—MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR57 (TL2) (3M Company, Maplewood, Minnesota)—also were tested over the same two days using a separate PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AX Tank Farm Exhauster Slipstream Volume 2: Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. To protect workers at Hanford Tank Farms, WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used at the tank farms. The tests were conducted to determine the period of time the cartridges would provide adequate performance for APRs and PAPRs when workers are exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. Occupational Safety and Health Administration (OSHA) Standard 29 Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life. The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. This report summarizes data analysis of APR and PAPR cartridge testing on a vapor slipstream from the Hanford AX tank farm exhauster. Volume 1 of this report documents the testing, data analysis, results, conclusions, and recommendations resulting from the cartridge testing on AX exhauster slipstream vapors. Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104 Volume 1

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in powered air-purifying respirators (PAPR) to determine the period of time that the cartridges would provide adequate performance for PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the headspaces of Hanford tanks SX-101 and SX-104. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 16-17, 2017, from headspace vapors from Hanford tank SX-101 and from June 23-24, 2017, from Hanford tank SX-104. Headspace vapors were fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose high-efficiency PAPR cartridges, MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (TL2) (3M Company, Maplewood, Minnesota) were assessed on separate days. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104: Volume 2 Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests of cartridges used in air-purifying respirators (APR) and powered air-purifying respirators (PAPR) commonly used at Hanford Tank Farms. The tests are conducted to determine the period of time the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. Occupational Safety and Health Administration (OSHA) Standard 29 Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life. The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. This report summarizes data analysis of PAPR cartridge testing on headspace vapors from Hanford SX-101 and SX-104 single-shell tanks. Two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota)—were assessed on each tank headspace source on separate days. These data represent the first PAPR cartridge testing under the recent WRPS program, as testing to date had been focused on APR cartridges. Volume 1 of this report documents the testing, data analysis, results, conclusions, and recommendations resulting from the PAPR testing on SX-101 and SX-104 headspace vapors. Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗