Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WAVELENGTHS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Overview of the distributed image processing infrastructure to produce the Legacy Survey of Space and Time

The Vera C. Rubin Observatory is preparing to execute the most ambitious astronomical survey ever attempted, the Legacy Survey of Space and Time (LSST). Currently the final phase of construction is under way in the Chilean Andes, with the Observatory’s ten-year science mission scheduled to begin in 2025. Rubin’s 8.4-meter telescope will nightly scan the southern hemisphere collecting imagery in the wavelength range 320–1050 nm covering the entire observable sky every 4 nights using a 3.2 gigapixel camera, the largest imaging device ever built for astronomy. Automated detection and classification of celestial objects will be performed by sophisticated algorithms on high-resolution images to progressively produce an astronomical catalog eventually composed of 20 billion galaxies and 17 billion stars and their associated physical properties. In this article we present an overview of the system currently being constructed to perform data distribution as well as the annual campaigns which reprocess the entire image dataset collected since the beginning of the survey. These processing campaigns will utilize computing and storage resources provided by three Rubin data facilities (one in the US and two in Europe). Each year a Data Release will be produced and disseminated to science collaborations for use in studies comprising four main science pillars: probing dark matter and dark energy, taking inventory of solar system objects, exploring the transient optical sky and mapping the Milky Way. Also presented is the method by which we leverage some of the common tools and best practices used for management of large-scale distributed data processing projects in the high energy physics and astronomy communities. We also demonstrate how these tools and practices are utilized within the Rubin project in order to overcome the specific challenges faced by the Observatory.

79 ASTRONOMY AND ASTROPHYSICS↗

Coherence imaging spectroscopy at Wendelstein 7-X for impurity flow measurements

In the last decade, Coherence Imaging Spectroscopy (CIS) has shown distinctive results in measuring ion flow velocities in the edge of magnetically confined plasma devices. Its 2D spatially resolved measurement capabilities and its high optical throughput are ideal for investigating the impurity behavior in the complex 3D magnetic island topology edge of Wendelstein 7-X (W7-X). However, a highly precise and stable calibration method is required for a reliable diagnostic operation. A new level of precision and stability has been achieved for the two CIS systems installed at W7-X with the use of a new calibration source, a continuous tunable laser commercially available only since 2015. A specific prototype model was successfully adapted to the challenging requirements of W7-X, granting high accuracy (±0.01 pm) and flexibility (spectral range: 450–650 nm) in the wavelength calibration required for measuring low-Z impurity ion flow velocities. These features opened up new investigation possibilities on temperature stability and wavelength response of the CIS components, allowing to fully characterize and validate the W7-X systems. The CIS diagnostic was operational throughout the last W7-X experimental campaign. Measured velocities on the order of ~20–30 km/s were observed, corroborated by comparisons with measurements with Mach probes.

47 OTHER INSTRUMENTATION↗

High sensitivity pump–probe measurements of magnetic, thermal, and acoustic phenomena with a spectrally tunable oscillator

We describe an optical pump/probe system for sensitive measurements of time-resolved optical measurements of material dynamics. The instrument design is optimized for time-resolved magneto-optic Kerr effect (TR-MOKE) measurements of dynamics in magnetic materials. The system also allows for time-domain thermoreflectance (TDTR) measurements of thermal transport properties and picosecond acoustic measurements of film thickness and/or elastic constants. The system has several advantages over the conventional designs for TRMOKE and/or TDTR systems. Measurements of pump-induced changes to the probe beam intensity are shot-noise limited. The system’s design allows for MOKE and/or thermoreflectance measurements of both sides of a sample. Pumping and probing the sample on opposite sides allows nanoscale flash diffusivity measurements of transport properties. The wavelengths of the pump and probe beams are straightforward to tune between 350–525 nm and 690–1050 nm. A tunable wavelength allows for optical resonances in a wide array of materials to be excited and/or probed. Finally, the setup is calibrated to allow for the real and imaginary components of Kerr signals to be separately quantified.

47 OTHER INSTRUMENTATION↗

Imaging plasma formation in isolated nanoparticles with ultrafast resonant scattering

We have recorded the diffraction patterns from individual xenon clusters irradiated with intense extreme ultraviolet pulses to investigate the influence of light-induced electronic changes on the scattering response. The clusters were irradiated with short wavelength pulses in the wavelength regime of different 4d inner-shell resonances of neutral and ionic xenon, resulting in distinctly different optical properties from areas in the clusters with lower or higher charge states. The data show the emergence of a transient structure with a spatial extension of tens of nanometers within the otherwise homogeneous sample. Simulations indicate that ionization and nanoplasma formation result in a light-induced outer shell in the cluster with a strongly altered refractive index. The presented resonant scattering approach enables imaging of ultrafast electron dynamics on their natural timescale.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of cross-beam energy transfer to control drive symmetry in ICF implosions in low gas fill Hohlraums at the National Ignition Facility

Cross beam energy transfer (CBET), invoked by setting a wavelength difference, Δλ, between inner and outer beam cones, can be used to increase the drive on the waist in indirectly driven inertial confinement fusion experiments at the National Ignition Facility (NIF). Historically, hot spot symmetry control in capsule implosions in high (≥0.9 mg/cm 3 4 He) gas fill Hohlraums was enabled by substantial CBET. However, these implosion designs suffered from inflight symmetry swings, high SRS backscatter on the inner cones, and significant hot electron generation posing a threat to DT fuel preheat. Subsequent experiments in larger, low (≤0.6 mg/cm 3 4 He) gas fill Hohlraums demonstrated round implosions by varying the inner cone fraction throughout the laser drive at Δλ = 0 Å while keeping backscatter and hot electron generation very low. To enable driving larger capsules at a given Hohlraum size, additional tools for implosion symmetry control are required. With this goal in mind, here we present a detailed experimental study of using CBET in low gas fill Hohlraums near NIF's current peak power capability. We find a ~2.5× higher sensitivity of the P 2 Legendre mode with respect to Δλ changes compared to that of high gas fill designs. We attribute this observation to the fact that backscatter remains very low and that CBET remains in a linear regime, as suggested by simulations. As a result, a much smaller Δλ of order 1 Å is sufficient for sustaining implosion symmetry while keeping laser-to- Hohlraum coupling high and hot electron generation very low. While this study used plastic ablator capsules, our findings can be generalized to other ablator materials and, hence, show great promise for using wavelength detuning as a strong lever for implosion symmetry control in future low gas fill designs that require smaller case to capsule ratios in order to increase the energy coupled to the capsule.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Super-resolution surface slope metrology of x-ray mirrors

We present experimental, analytical, and numerical methods developed for reconstruction (deconvolution) of one-dimensional (1D) surface slope profiles over the spatial frequency range where the raw data are significantly perturbed due to the limited resolution of the measurement instrument. We characterize the spatial resolution properties of a profiler with the instrument's transfer function (ITF). To precisely measure the ITF, we apply a recently developed method utilizing test surfaces with 1D linear chirped height profiles of constant slope amplitude. Based on the results of the ITF calibration, we determine parameters of an analytical model for the ITF that is used in the original reconstruction software. Here, we treat surface slope metrology data obtained with the Optical Surface Measuring System (OSMS), using as a sensor an electronic autocollimator (AC) ELCOMAT-3000. The spatial resolution of the OSMS is limited by the size of the AC light-beam-collimating aperture. For the purposes of this investigation, the OSMS is equipped with a circular aperture with a diameter of 2.5 mm. This is a typical arrangement of most AC-based slope profilers developed for surface slope metrology of state-of-the-art x-ray mirrors. Using the example of surface slope metrology of two state-of-the-art elliptically shaped x-ray focusing mirrors, we demonstrate that the developed data reconstruction procedure allows us to significantly improve the accuracy of surface slope metrology with the OSMS over the spatial wavelength range from ~1.6 mm to 7 mm. Thus, the amplitude of the quasi-periodic error characteristic of the deterministic polishing process used appears to be higher by a factor of~2 than is apparent from the rough metrology data. Underestimation of the surface slope errors in this spatial wavelength range can lead to serious errors in the expected performance of x-ray mirrors in synchrotron beamlines, especially at modern light sources utilizing coherent x rays, where the perturbations can lead to increased speckle-like intensity variation.

47 OTHER INSTRUMENTATION↗

Magnetic reconnection and kinetic waves generated in the Earth's quasi-parallel bow shock

Magnetic reconnection in quasi-parallel shocks, relevant to the Earth’s bow shock, is studied by means of two-dimensional full particle-in-cell simulations. As the Alfvénic Mach number increases, the propagation direction of the waves excited in the transition region changes, and the shock becomes more turbulent with more reconnection sites. In the higher Mach number shock, abundant electron-only reconnection sites are generated with scales on the order of the ion skin depth or less. Non-reconnecting current sheets can also generate electron jets and energy dissipation can occur there as well. However, non-reconnecting current sheets with the magnetic field reversal typically show a smaller energy dissipation rate than reconnecting current sheets. In the shock transition region, two types of waves are responsible for driving reconnection: one has a wavelength around three ion skin depths (d i ), and the other has a wavelength less than 1 d i . Here, electron and ion distribution functions show that in regions where the former type of waves is excited, there are two ion beams and a single-peaked electron distribution. In contrast, in regions where the latter type of waves is excited, there are multiple electron and ion beams. The waves propagating obliquely to the magnetic field bend the magnetic field lines, and magnetic reconnection occurs where oppositely directed field lines come into contact.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coherent high-power RF wakefield generation by electron bunch trains in a metamaterial structure

In this paper, we present an experimental study of coherent high-power wakefield generation in a metamaterial (MTM) structure at 11.7 GHz by 65 MeV electron bunch trains at the Argonne Wakefield Accelerator (AWA), following a previous experiment, the Stage-I experiment, at the AWA. Both the Stage-II experiment, reported in this paper, and the Stage-I experiment were conducted using MTM structures, which are all-metal periodic structures with the period being much smaller than the wavelength. Differences between the two experiments include (1) structure length (Stage-I 8 cm and Stage-II 20 cm); (2) number of bunches used to excite the structure (Stage-I with two bunches, up to 85 nC of total charge; Stage-II with eight bunches, up to 224 nC of total charge); and (3) highest peak power measured (Stage-I 80 MW in a 2 ns pulse and Stage-II 380 MW in a 10 ns pulse). High-power radio frequency pulses were generated by reversed Cherenkov radiation of the electron beam due to the negative group velocity in the MTM structures. Because the radiation is coherent, a train of bunches with a proper spacing can build up to achieve a high peak power. The observed output power levels are very promising for future applications in direct collinear wakefield acceleration or in transfer to a second accelerator for two-beam acceleration.

36 MATERIALS SCIENCE↗

Two-color scattering for the measurement of neutrals at the edge of fusion devices

Laser two-color scattering (TCS) is proposed to detect the neutral species in the edge of fusion devices, namely, tokamaks. Here, TCS uses two wavelengths to probe both the laser Rayleigh scattering and Thomson scattering of the neutral-electron bath, with emphasis on neutral density measurements such as that of hydrogen and deuterium. Modeling of the Rayleigh scattering of tokamak neutral species under various plasma conditions (electron density and temperature) shows that, with an appropriate filtering of the Thomson signal and by going to ultraviolet-region wavelengths, identification of the Rayleigh signal can be achieved. Photon count and signal fractions are calculated in two test cases, one in the midplane region of the National Spherical Torus Experiment and one in the divertor region of DIII-D. An uncertainty analysis and discussion of the feasibility of the TCS diagnostic is also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Second Generation Readout For Large Format Photon Counting Microwave Kinetic Inductance Detectors

We present the development of a second generation digital readout system for photon counting microwave kinetic inductance detector (MKID) arrays operating in the optical and near-infrared wavelength bands. Our system retains much of the core signal processing architecture from the first generation system but with a significantly higher bandwidth, enabling the readout of kilopixel MKID arrays. Each set of readout boards is capable of reading out 1024 MKID pixels multiplexed over 2 GHz of bandwidth; two such units can be placed in parallel to read out a full 2048 pixel microwave feedline over a 4 GHz–8 GHz band. As in the first generation readout, our system is capable of identifying, analyzing, and recording photon detection events in real time with a time resolution of order a few microseconds. Here, we describe the hardware and firmware, and present an analysis of the noise properties of the system. We also present a novel algorithm for efficiently suppressing IQ mixer sidebands to below −30 dBc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of dynamic surface changes by digital holography for in situ plasma erosion applications

There are currently few viable diagnostic techniques for in situ measurement of plasma facing component erosion. Digital holography is intended to fill this gap. Progress on the development of single and dual CO 2 laser digital holography diagnostics for in situ plasma facing component erosion is discussed. The dual laser mode’s synthetic wavelength allows the measurable range to be expanded by a factor of ~400 compared to single laser digital holography. This allows the diagnostic to measure surface height changes of up to 4.5 μm in single laser mode and up to 2 mm in dual laser mode. Results include ex situ measurements of plasma eroded targets and also dynamic measurements of nm and μm scale motion of a target mounted on a precision translation stage. Dynamic measurements have successfully been made with the system operating in both single and dual laser modes, from ~50 nm to ~4 μm in single laser mode and up to ~400 μm in dual laser mode (limited only by the stage speed and camera acquisition duration). These results demonstrate the feasibility of using digital holography to characterize plasma facing component erosion dynamically, i.e., during plasma exposure. Results of proof-of-principle in situ digital holographic measurements of targets exposed to an electrothermal arc plasma source are presented.

Smith, Cary↗

The fluorescence quantum yield parameter in Förster resonance energy transfer (FRET)—Meaning, misperception, and molecular design

The fluorescence quantum yield parameter in Förster resonance energy transfer (FRET) processes underpins vital phenomena ranging from light harvesting in photosynthesis to design of sensors for monitoring physiological processes. The criteria for choosing a donor for use in FRET processes include chemical features (solubility, bioconjugatability, synthetic accessibility, and stability) as well as photophysical properties pertaining to absorption (wavelength and molar absorption coefficient) and fluorescence (wavelength and fluorescence quantum yield). The value of the donor fluorescence quantum yield (Φf, or emphatically, Φf(D)) alone has sometimes been thought (erroneously) to place a ceiling on the possible quantum yield of energy transfer (Φtrans). A high value of the donor Φf, while attractive, is not at all essential; indeed, many valuable candidates for use as FRET donors have likely been excluded on the basis of this injudiciously applied filter. Such disregard is unwarranted. In this tutorial overview, the equations for FRET are reviewed along with pertinent core concepts in photophysics. An analogy using simple hydraulics provides a pedagogical tool for the non-aficionado to better understand photochemical kinetics. Ten examples are presented of donor–acceptor systems with donors that exhibit a range of Φf values (0.60, 0.59. 0.21, 0.17, 0.12, 0.118, 0.04, 0.018, 0.007, and 0.003; i.e., 60%–0.3%), yet for each corresponding donor–acceptor pair, the value of Φtrans is at least 0.70 and in some cases nearly 1.00 (i.e., 70%–100%). The systems encompass protein, synthetic inorganic, and synthetic organic architectures. The objectives of this illustrative review are to deepen understanding of FRET and to broaden molecular design considerations by enabling selection from among a far richer set of donors for use in FRET processes.

Lindsey, Jonathan S. (ORCID:0000000248722040)↗

Simulations of the shock-driven Kelvin–Helmholtz instability in inclined gas curtains

In this paper, we present simulation results for the two-dimensional, shock-driven Kelvin–Helmholtz instability. Simulations are performed with a Mach 2.0 shock propagating through a finite-thickness curtain of gas inclined at an angle α0=30° with respect to the shock plane. After the passage of the shock, the gas curtain is accelerated along its axis. A perturbation develops due to shock reflection near the lower wall, and a Kelvin–Helmholtz instability forms near the vertical center of the curtain. This is the first known numerical reproduction of these phenomena that have previously been observed in experiments with an inclined cylindrical gas column. The effects of varying Mach number and column width were explored in detail to complement experimental data. Additionally, the dependence of the Kelvin–Helmholtz wavelength on Mach number closely matches the relationship observed in experiments. This supports the notion that the observed instability is effectively two-dimensional and inviscid (like classical Kelvin–Helmholtz). The growth rate of the perturbations in the gas curtain was also found to be similar for different Mach numbers. The perturbation at the curtain foot, previously unreported in experiments, was found to have a similar relationship to Mach number as the Kelvin–Helmholtz instability. Both perturbation wavelengths are found to be proportional to layer width. Simulations were performed with the fast interfaces and transport in the atmosphere, an exascale ready, graphics processing unit-accelerated compressible flow solver developed at the University of New Mexico.

42 ENGINEERING↗

Lower-hybrid drift waves and their interaction with plasmas in a 3D symmetric reconnection simulation with zero guide field

We investigate lower-hybrid drift waves (LHDW) in symmetric magnetic reconnection with zero guide field using three-dimensional particle-in-cell simulations. The long-wavelength mode with kρiρe∼1 develops in the bifurcated electron current layer around the X-line within the width of the electron meandering motion from the mid-plane, where ρi(e) is the ion (electron) gyroradius. The short-wavelength mode with kρe∼1 develops in the separatrix region downstream of the electron outflow jet, producing electron vortices in the background flow frame. Electrons follow the E × B drift with corrections from the diamagnetic drift and are heated inside the vortices with diverging electric fields. In the vortices, ions have comparable E × B and inertia drifts, which together mostly cancel the diamagnetic drift. Toward the center of diverging field vortices, ions are decelerated, leading to a decrease in the perpendicular temperature, while the loss of low-energy ions results in an increase in the parallel temperature. Parallel electric fields exist as a combination of the LHDW wave field projected to the magnetic field direction and the penetration of whistler waves that are mainly outside of the LHDW layer. The magnetic flux tube is twisted in the vortices. The twist may potentially lead to slippage reconnection, as indicated by the non-uniform parallel potential variation across field lines, while the periodic variations of the twisting directions are a limiting factor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Background measurement methods for opacity experiments conducted at the Z facility

Laboratory experiments typically test opacity models by measuring spectrally resolved transmission of a sample using bright backlight radiation. A potential problem is that any unaccounted background signal contaminating the spectrum will artificially reduce the inferred opacity. Methods developed to measure background signals in opacity experiments at the Sandia Z facility are discussed. Preliminary measurements indicate that backgrounds are 9%–11% of the backlight signal at wavelengths less than 10 Å. Background is thus a relatively modest correction for all Z opacity data published to date. Future work will determine how important background is at longer wavelengths.

47 OTHER INSTRUMENTATION↗

Dispersion relation for gauge-free electromagnetic drift kinetics

Recently, a new approach to gyrokinetics, invariant under electromagnetic gauge transformations, was developed. The gyrocenter equations of motion are now expressed in terms of the perturbed fields instead of the potentials, in a form suitable for numerical simulations and analytic studies. In this paper, we verify that the long-wavelength limit, i.e., the drift-kinetic limit of the new gyrokinetic theory, is in line with existing work, providing a solid foundation for simulations. Here, we compute the dispersion relation of the new drift-kinetic theory in slab geometry and find agreement with a long-wavelength limit of the full Vlasov–Maxwell model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generation and detection of 50 GHz surface acoustic waves by extreme ultraviolet pulses

In this work, we use femtosecond extreme ultraviolet pulses derived from a free electron laser to excite and probe surface acoustic waves (SAWs) on the (001) surface of single crystal SrTiO 3 . SAWs are generated by a pair of 39.9 nm pulses crossed at the sample with the crossing angle defining the SAW wavelength at 84 nm. Detection of SAWs is performed via diffraction of a time-delayed 13.3 nm probe pulse by SAW-induced surface ripples. Despite the low reflectivity of the sample in the extreme ultraviolet range, the reflection mode detection is found to be efficient because of an increase in the diffraction efficiency for shorter wavelengths. We describe a methodology for extracting the SAW attenuation in the presence of a thermal grating, which is based on measuring the decay of oscillations at twice the SAW frequency. The proposed approach can be used to study ultrahigh frequency SAWs in a broad range of materials and will bridge the wave vector gap in surface phonon spectroscopy between Brillouin scattering and He atom scattering.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TIA: A forward model and analyzer for Talbot interferometry experiments of dense plasmas

Interferometry is one of the most sensitive and successful diagnostic methods for plasmas. However, owing to the design of most common interferometric systems, the wavelengths of operation and, therefore, the range of densities and temperatures that can be probed are severely limited. Talbot–Lau interferometry offers the possibility of extending interferometry measurements to x-ray wavelengths by means of the Talbot effect. While there have been several proof-of-concept experiments showing the efficacy of this method, it is only recently that experiments to probe High Energy Density (HED) plasmas using Talbot–Lau interferometry are starting to take place. To improve these experimental designs, we present here the Talbot-Interferometry Analyzer (TIA) tool, a forward model for generating and postprocessing synthetic x-ray interferometry images from a Talbot–Lau interferometer. Although TIA can work with any two-dimensional hydrodynamic code to study plasma conditions as close to reality as possible, this software has been designed to work by default with output files from the hydrodynamic code FLASH, making the tool user-friendly and accessible to the general plasma physics community. Here, the model has been built into a standalone app, which can be installed by anyone with access to the MATLAB runtime installer and is available upon request to the authors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗