Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Total”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

LM193 Dual Differential Comparator Total Ionizing Dose Test Report

The purpose of this test was to characterize the flight lot of Texas Instruments' LM193 (flight part number is 5962-9452601Q2A) for total dose response. This test served as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) was determined.

enhanced low dose rate sensitivity (ELDRS↗

ISSI IS46DR16640B-25DBA25 DDR2 SDRAM Total Ionizing Dose Characterization Test Report

The purpose of this testing is to characterize the ISSI IS46DR16640B-25DBA25 parameter degradation for total dose response. This test’s purpose is to evaluate and compare lot date codes for sensitivity. In the test, the device is exposed to both low dose and high dose rate (HDR) irradiations using gamma radiation. Device parameters such as leakage currents, quantity of upset bits or addresses, and overall chip and die health are investigated to determine which lot is more robust. These parameters directly affect the functionality of the memory within a system and may determine thresholds necessary to mitigate failure.

Total Ionizing Dose (TID)↗

Room Temperature Total-Ionizing Dose Testing of Glenn Research Center (GRC) 500 °C Durable 4H-SiC JFET IC Technology

The purpose of this testing was to obtain total ionizing dose (TID) information about custom-built research prototype silicon carbide (SiC) junction field effect transistor (JFET) integrated circuits (ICs) capable of prolonged operation in extremely high-temperature (500 degrees Centigrade) environments. The circuits included ring oscillators and operational amplifiers as well as individual n-channel JFETs. This technology is being considered for use in high temperature, high pressure applications such as Long-Lives Surface System Explorer (LLISSE). These devices were developed at NASA Glenn Research Center (GRC). Testing occurred from July 9th-July 13th, 2018.

Radiation↗

Avalanche ASV016204 (Pre-Production Samples) 40nm MRAM Total Ionizing Dose Test Report

The purpose of this test was to characterize the Avalanche Technology ASV016204’s total dose response. In the test, the device was exposed to high dose rate (HDR) irradiations using gamma radiation. Device functionality (in terms of memory cell upsets and read/write ability) as well as power supply currents during various modes of operations were recorded.

Total Ionizing Dose (TID)↗

Robust Algorithm for Estimating Total Suspended Solids (TSS) in Inland and Nearshore Coastal Waters

One of the challenging tasks in modern aquatic remote sensing is the retrieval of near-surface concentrations of Total Suspended Solids (TSS). This study aims to present a Statistical, inherent Optical property (IOP) -based, and muLti-conditional Inversion proceDure (SOLID) for enhanced retrievals of satellite-derived TSS under a wide range of in-water bio-optical conditions in rivers, lakes, estuaries, and coastal waters. In this study, using a large in situ database (N > 3500), the SOLID model is devised using a three-step procedure: (a) water-type classification of the input remote sensing reflectance (R(sub rs)), (b) retrieval of particulate backscattering (b(sub bp)) in the red or near-infrared (NIR) regions using semi-analytical, machine-learning, and empirical models, and (c) estimation of TSS from b(sub bp) via water-type-specific empirical models. Using an independent subset of our in situ data (N = 2729) with TSS ranging from 0.1 to 2626.8 [g/m (exp 3)], the SOLID model is thoroughly examined and compared against several state-of-the-art algorithms (Miller and McKee, 2004; Nechad et al., 2010; Novoa et al., 2017; Ondrusek et al., 2012; Petus et al., 2010). We show that SOLID outperforms all the other models to varying degrees, i.e., from 10 to > 100%, depending on the statistical attributes (e.g., global versus water-type-specific metrics). For demonstration purposes, the model is implemented for images acquired by the MultiSpectral Imager aboard Sentinel-2A/B over the Chesapeake Bay, San-Francisco-Bay-Delta Estuary, Lake Okeechobee, and Lake Taihu. To enable generating consistent, multimission TSS products, its performance is further extended to, and evaluated for, other missions, such as the Ocean and Land Color Instrument (OLCI), Moderate Resolution Imaging Spectroradiometer (MODIS), Visible Infrared Imaging Radiometer Suite (VIIRS), and Operational Land Imager (OLI). Sensitivity analyses on uncertainties induced by the atmospheric correction indicate that 10% uncertainty in Rrs leads to < 20% uncertainty in TSS retrievals from SOLID. While this study suggests that SOLID has a potential for producing TSS products in global coastal and inland waters, our statistical analysis certainly verifies that there is still a need for improving retrievals across a wide spectrum of particle loads.

Total suspended solids↗

Goddard Modular SmallSat Architecture (GMSA) Adapter Board H-Bridge MOSEFT ICs Total Ionizing Dose Characterization Report

The purpose of this testing was to obtain total ionizing dose (TID) information about commercial off-the-shelf (COTS) n-channel and p-channel MOFETs that are being considered for use on the Goddard Modular SmallSat Architecture (GMSA) Adapter board in an H-Bridge circuit to drive magnetorquers. Testing took place at NASA Goddard Space Flight Center’s (GSFC) Radiation Effects Facility using the gamma source. Testing occurred from July 31st – August 1st, 2018.

total ionizing dose (TID)↗

Analog Devices ADXL354 Low Noise, Low Drift, Low Power, 3-Axis MEMS Accelerometer Total Ionizing Dose Characterization Test Report

The purpose of this test was to characterize the Analog Devices ADXL354 parameter degradation for total dose response. In the test, the device was exposed to a dose rate of 50 rad(Si)/s or 0.5 Gy(Si)/s using a gamma radiation source in accordance with MIL-STD-883K Paragraph 3.6.1 (Condition A). Device parameters such as supply current, self-test voltage response, and LDO regulator output voltages were monitored.

Total Ionizing Dose (TID)↗

Total Ionizing Dose (TID) Testing of the PA10 Power Operational Amplifier

This study was undertaken to determine the total ionizing dose (TID) sensitivity of the PA10 Power Op Amp Manufactured by APEX (figure 1), which is a candidate for use on the LDCM TIRS instrument. The test was conducted with interest in both parametric degradation and functional failure in the configuration like that of the TIRS application. (See figure 2). The DUT was irradiated in a stepwise fashion, with parametric and functional degradation measured between steps. The parts were irradiated with gamma rays at a low dose rate (~0.01 rads(Si)/sec.).

total ionizing dose (TID)↗

Remotely Estimating Total Suspended Solids Concentration in Clear to Extremely Turbid Waters Using a Novel Semi-Analytical Method

Total suspended solids (TSS) concentration is an important biogeochemical parameter for water quality management and sediment-transport studies. In this study, we propose a novel semi-analytical method for estimating TSS in clear to extremely turbid waters from remote-sensing reflectance (Rrs). The proposed method includes three sub-algorithms used sequentially. First, the remotely sensed waters are classified into clear (Type I), moderately turbid (Type II), highly turbid (Type III), and extremely turbid (Type IV) water types by comparing the values of Rrs at 490, 560, 620, and 754 nm. Second, semi-analytical models specific to each water type are used to determine the particulate backscattering coefficients (bbp) at a corresponding single wavelength (i.e., 560 nm for Type I, 665 nm for Type II, 754 nm for Type III, and 865 nm for Type IV). Third, a specific relationship between TSS and bbp at the corresponding wavelength is used in each water type. Unlike other existing approaches, this method is strictly semi-analytical and its sub-algorithms were developed using synthetic datasets only. The performance of the proposed method was compared to that of three other state-of-the-art methods using simulated (N = 1000, TSS ranging from 0.01 to 1100 g/m3) and in situ measured (N = 3421, TSS ranging from 0.09 to 2627 g/m3) pairs of Rrs and TSS. Results showed a significant improvement with a Median Absolute Percentage Error (MAPE) of 16.0% versus 30.2–90.3% for simulated data and 39.7% versus 45.9–58.1% for in situ data, respectively. The new method was subsequently applied to 175 MEdium Resolution Imaging Spectrometer (MERIS) and 498 Ocean and Land Colour Instrument (OLCI) images acquired in the 2003–2020 timeframe to produce long-term TSS time-series for Lake Suwa and Lake Kasumigaura, Japan. Performance assessments using MERIS and OLCI matchups showed good agreements with in situ TSS measurements.

Mulit-Wavelength↗

Si5345, SY88422L, LT3482, and MSK130 components Total Ionizing Dose Test Report

The purpose of this test was to characterize the SI-5345, SY88422L, LT3482 and MSK130 parameter degradation for total dose response. The components are associated with REAG ID #21-024. In the test, each device was exposed to high dose rate (HDR) irradiation using gamma radiation. Device parameters such as leakage currents, timing, and overall chip health were investigated. These devices were tested for an interstellar mission on a trajectory between 0.9 AU and 5.3 AU with a 2.5-year mission, yielding an expected overall dose of 29 krad(Si)behind 1 mm of aluminum shielding (at 95% confidence; environment and dose determined through SPENVIS). This test report gives an initial look at candidate parts. Extremely small sample sizes (only 1 or 2 devices tested) do not allow consideration of part-to-part variability. High dose rates were used despite LT3482 and MSK130 having potential enhanced low dose rate sensitivity (ELDRS). Care should be taken in interpreting results given these limitations.

Total Ionizing Dose (TID)↗

A Regional Classification of Time Spectral Amplitudes in Total Electron Content: Southeastern United States During Solar Cycle 24

To investigate the meso-scale structure (100 s of km) of the ionosphere at mid-latitudes, the spectral properties in calculated total electron content (TEC) at a cluster of GPS receivers in and around Florida are analyzed. The ionosphere does not respond exactly the same to periodic solar driving at different locations around the planet, due to the complex electrodynamic interactions of the coupled magnetosphere-ionosphere system. Therefore, at each GPS receiver in the cluster we compare spatio-temporal variations of the spectral amplitudes for diurnal, solar rotation, and seasonal oscillations. The amplitudes for these dominant oscillations are organized with respect to magnetic latitude of the receiver. A low-latitude and high-latitude station are also included to put the mid-latitude ionospheric response into a global context. The amplitudes of diurnal, seasonal, and solar rotation signals are well ordered by magnetic latitude, superposed with meso-scale deviations between stations separated by ~100s of km. The results suggest that spatio-temporal variations of spectral amplitudes in the mid-latitude ionosphere are not dominated by a single process. This conclusion is based on our finding that at high latitude, the shape of the diurnal signal varies significantly less with solar activity compared to low- and mid-latitudes, and additionally, that the ratio of annual to semi-annual amplitudes fluctuates around 1 with time and from station-to-station only at mid-latitudes.

ionosphere↗

Integration of Total-Sky Imager Data with a Physics-Based Smart Persistence Model for Intra-Hour Forecasting of Solar Radiation

Short-term solar forecasting models based solely on global horizontal irradiance (GHI) measurements are often unable to discriminate the forecasting of the factors affecting GHI from those that can be precisely computed by atmospheric models. Our previous study introduced a Physics-based Smart Persistence model for Intra-hour forecasting of solar radiation (PSPI) that decomposed the forecasting of GHI into the computation of extraterrestrial solar radiation and solar zenith angle and the forecasting of cloud albedo and cloud fraction. The extraterrestrial solar radiation and solar zenith angle were accurately computed by the Solar Position Algorithm (SPA) developed at the National Renewable Energy Laboratory (NREL). A cloud retrieval technique was used to estimate cloud albedo and cloud fraction from surface-based observations of GHI. With the assumption of persistent cloud structures, the cloud albedo and cloud fraction were predicted for future time steps using a two-stream approximation and a 5-minute exponential weighted moving average, respectively. The model evaluation indicated the estimation and forecast of cloud fraction mostly contributed to the uncertainty of the PSPI though it overcame the persistence and smart persistence models in all forecast time horizons between 5 and 60 minutes. This study aims to enhance the PSPI by ingesting surface-based observations of cloud fraction from a total sky imager (TSI). The estimation and forecast of cloud albedo is correspondingly improved by utilizing the cloud fraction observations and thus leads to more accurate GHI forecast. Various time-series analysis methods are also investigated on the forecasting of cloud fraction and cloud albedo for further improving the GHI forecast. These improvements are valuable for many applications, such as forecasting energy use for buildings, grid operations, and ultimately bringing down the cost of solar energy.

14 SOLAR ENERGY↗