Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thomson”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Characterizing counter-streaming interpenetrating plasmas relevant to astrophysical collisionless shocks

A series of Omega experiments have produced and characterized high velocity counter-streaming plasma flows relevant for the creation of collisionless shocks. Single and double CH{sub 2} foils have been irradiated with a laser intensity of {approx} 10{sup 16} W/cm{sup 2}. The laser ablated plasma was characterized 4 mm from the foil surface using Thomson scattering. A peak plasma flow velocity of 2000 km/s, an electron temperature of {approx} 110 eV, an ion temperature of {approx} 30 eV, and a density of {approx} 10{sup 18} cm{sup -3} were measured in the single foil configuration. Significant increases in electron and ion temperatures were seen in the double foil geometry. The measured single foil plasma conditions were used to calculate the ion skin depth, c/{omega}{sub pi}{approx}0.16 mm, the interaction length, Script-Small-L {sub int}, of {approx} 8 mm, and the Coulomb mean free path, {lambda}{sub mfp}{approx}27mm. With c/{omega}{sub pi} Much-Less-Than Script-Small-L {sub int} Much-Less-Than {lambda}{sub mfp}, we are in a regime where collisionless shock formation is possible.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Central electron temperature estimations of TJ-II neutral beam injection heated plasmas based on the soft x ray multi-foil technique

The core electron temperature (T{sub e0}) of neutral beam heated plasmas is determined in TJ-II stellarator by using soft x ray detectors with beryllium filters of different thickness, based on the method known as the foil absorption technique. T{sub e0} estimations are done with the impurity code IONEQ, making use of complementary information from the TJ-II soft x ray tomography and the VUV survey diagnostics. When considering the actual electron density and temperature profile shapes, an acceptable agreement is found with Thomson scattering measurements for 8 different magnetic configurations. The impact of the use of both neutral beam injectors on the T{sub e0} measurements is addressed. Also, the behaviour of T{sub e0} during spontaneous profile transitions is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generation of high power sub-terahertz radiation from a gyrotron with second harmonic oscillation

New power records of second harmonic gyrotron oscillation have been demonstrated in the sub-THz band. The first step gyrotron of demountable type had succeeded in oscillation with power more than 50 kW at 350 GHz and nearly 40 kW at 390 GHz [T. Notake et al., Phys. Rev. Lett. 103, 225002 (2009)]. Then, the second step gyrotron of sealed-off type was manufactured. A cavity mode was carefully selected to avoid mode competition with a neighboring fundamental harmonic mode. Matching of the selected mode with the electron gun was also circumspectly considered. The second step gyrotron has attained higher power radiation than the first gyrotron. The maximum single mode power was 62 kW at 388 GHz. Then, the electron gun was modified for use of a different cavity mode with a higher coupling coefficient than that for the 62 kW mode. The new mode proved single mode oscillation power of 83 kW at about 389 GHz. These results are new second-harmonic-oscillation power records for sub-THz gyrotrons. The present study constitutes foundations of development of high power second harmonic sub-THz gyrotron for application to collective Thomson scattering measurement on fusion plasmas, especially on high-density plasmas such as those produced in LHD [N. Ohyabu et al., Phys. Rev. Lett. 97, 055002 (2006)]. This paper reports the design consideration to realize high power single mode gyrotron oscillation at second harmonic and the examination of oscillation characteristics of the gyrotron.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interaction of 0.53 {mu}m laser pulse with millimeter-scale plasmas generated by gasbag target

Detailed research on the interaction of a 0.53 {mu}m laser pulse with millimeter-scale plasmas produced by a gasbag target on the Shengguang-II facility is presented. The x-ray pinhole images confirm that millimeter-scale plasmas are generated and the x-ray framing images show a temporal window of 0.6-1.1 ns during which the millimeter-scale plasmas exist. The electron temperature is measured with a collective Thomson scattering system, providing 0.64 keV for C{sub 5}H{sub 12} and 1.8 keV for Xe plasmas. The electron density is inferred from the stimulated Raman scattering spectra. The experimental spectra show large differences for C{sub 5}H{sub 12}- and Xe-filled gasbags. A one-dimensional code based upon steady-state, kinetic linear theory is applied to calculate the stimulated Raman scattering spectra. Excellent agreement between the calculated and experimental results shows that the plasma parameters, especially the electron density and the temperature, dominate the disruption behavior of stimulated Raman scattering. The results also indicate that stimulated Raman scattering is probably located within specific region of the gasbag. The time-integrated reflectivity of both the stimulated Raman and Brillouin scattering is at a low level, even in the conditions of high laser intensity (1.5 Multiplication-Sign 10{sup 15} W/cm{sup 2}) and no beam-smoothing. The experimental results are promising for future ignition experiments with a 0.53 {mu}m laser as the driver.

2-METHYLBUTANE↗

Implementation of a multichannel soft x-ray diagnostic for electron temperature measurements in TJ-II high-density plasmas

Based on the multi-foil technique, a multichannel soft x-ray diagnostic for electron temperature measurements has been recently implemented in the TJ-II stellarator. The diagnostic system is composed by four photodiodes arrays with beryllium filters of different thickness. An in-vacuum amplifier board is coupled to each array, aiming at preventing induced noise currents. The Thomson scattering and the vacuum ultraviolet survey diagnostics are used for assessing plasma profiles and composition, being the analysis carried out with the radiation code IONEQ. The electron temperature is determined through the different signal-pair ratios with temporal and spatial resolution. The design and preliminary results from the diagnostic are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact 'diode-based' multi-energy soft x-ray diagnostic for NSTX

A novel and compact, diode-based, multi-energy soft x-ray (ME-SXR) diagnostic has been developed for the National Spherical Tokamak Experiment. The new edge ME-SXR system tested on NSTX consists of a set of vertically stacked diode arrays, each viewing the plasma tangentially through independent pinholes and filters providing an overlapping view of the plasma midplane which allows simultaneous SXR measurements with coarse sub-sampling of the x-ray spectrum. Using computed x-ray spectral emission data, combinations of filters can provide fast (>10 kHz) measurements of changes in the electron temperature and density profiles providing a method to 'fill-in' the gaps of the multi-point Thomson scattering system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A field programmable gate array unit for the diagnosis and control of neoclassical tearing modes on MAST

A real-time system has been developed to trigger both the MAST Thomson scattering (TS) system and the plasma control system on the phase and amplitude of neoclassical tearing modes (NTMs), extending the capabilities of the original system. This triggering system determines the phase and amplitude of a given NTM using magnetic coils at different toroidal locations. Real-time processing of the raw magnetic data occurs on a low cost field programmable gate array (FPGA) based unit which permits triggering of the TS lasers on specific amplitudes and phases of NTM evolution. The MAST plasma control system can receive a separate trigger from the FPGA unit that initiates a vertical shift of the MAST magnetic axis. Such shifts have fully removed m/n= 2/1 NTMs instabilities on a number of MAST discharges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radial profile measurement of electron temperature in edge stochastic magnetic field layer of LHD using intensity ratio of extreme ultraviolet line emissions

Vertical profile of neon line emissions in 30-650 A wavelength range has been observed in horizontally elongated plasma cross section of Large Helical Device (LHD). Intensity ratio between the neon line emissions is studied to measure the radial profile of electron temperature in the edge stochastic magnetic field layer of LHD. The edge temperature profile successfully obtained from the line ratio of NeVIII 2s-3p to 2p-3s transitions is compared with the simulation based on three-dimensional edge transport code. The result shows a reasonably good agreement with the edge temperature profile analyzed from atomic data and analysis structure code. The electron temperature at last closed flux surface measured from the intensity ratio is also in good agreement with that measured from Thomson scattering.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First results from EBW emission diagnostics on COMPASS

COMPASS tokamak shots at low magnetic field feature overdense plasmas during the extended current flat-top phase. The first harmonic of the electron cyclotron emission is completely cutoff for O and X modes and so the emission caused by electron Bernstein waves (EBWs) propagating obliquely with respect to the magnetic field and undergoing so called EBW-X-O conversion process can be observed. We perform an angular scan of the EBW emission during a set of comparable shots in order to determine the optimum antenna direction. A weak dependence of the radiative temperature on the antenna angles indicates an influence of multiple reflections from the vessel wall. The low temperature at the mode conversion region is responsible for the collisional damping of EBW, which can explain several times lower measured radiative temperature than the electron temperature measured by the Thomson scattering system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HELIOS: A helium line-ratio spectral-monitoring diagnostic used to generate high resolution profiles near the ion cyclotron resonant heating antenna on TEXTOR

Radial profiles of electron temperature and density are measured at high spatial ({approx}1 mm) and temporal ( Greater-Than-Or-Slanted-Equal-To 10 {mu}s) resolution using a thermal supersonic helium jet. A highly accurate detection system is applied to well-developed collisional-radiative model codes to produce the profiles. Agreement between this measurement and an edge Thomson scattering measurement is found to be within the error bars ( Less-Than-Or-Equivalent-To 20%). The diagnostic is being used to give profiles near the ion cyclotron resonant heating antenna on TEXTOR to better understand RF coupling to the core.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron density and temperature profile diagnostics for C-2 field reversed configuration plasmas

The 9-point Thomson scattering diagnostic system for the C-2 field reversed configuration plasmas is improved and the measured electron temperature profiles are consistent with theoretical expectations. Rayleigh scattering revealed a finite line width of the ruby laser emission, which complicates density calibration. Taking advantage of the plasma wobble motion, density profile reconstruction accuracy from the 6-chord two-color CO{sub 2}/HeNe interferometer data is improved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-performance double-filter soft x-ray diagnostic for measurement of electron temperature structure and dynamics

A new soft x-ray (SXR) T{sub e} and tomography diagnostic has been developed for MST that can be used for simultaneous SXR spectrum measurement, tomographically reconstructed emissivity, and reconstructed and line-of-sight electron temperature. The diagnostic utilizes high-performance differential transimpedance amplifiers (gain 10{sup 5}-10{sup 9}) to provide fast time response (up to 125 kHz), allowing for the study of plasma structure dynamics. SXR double-foil T{sub e} measurements are consistent with Thomson scattering. SXR brightness through a variety of filter thicknesses has been combined with charge exchange recombination spectroscopy (CHERS) impurity density measurements to determine the plasma energy spectrum. Magnetic pickup from the fluctuating magnetic fields in the plasma (B(tilde sign){approx}20 gauss at 10-20 kHz) has been dramatically reduced by improving the detector and housing design, so that nanoampere diode currents are now measured without interference from the substantial fluctuating magnetic field incident on the plasma facing surface of the probe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of neutral density profiles using a deuterium Balmer-alpha diagnostic in the C-2 FRC plasma

In C-2 field-reversed configuration (FRC) device, low neutral density outside the FRC separatrix is required to minimize the charge exchange loss of fast particles. Titanium gettering is used in C-2 to reduce the wall recycling and keep the neutral density low in plasma edge. The measurements of neutral density radial profile are desirable to understand the plasma recycling and the effects of titanium gettering. These measurements are also needed to study the interaction of neutral beams with FRC plasma and confinement of fast ions. Diagnostic based on absolute deuterium Balmer-alpha (D-alpha) radiation measurements is developed and deployed on C-2 device to measure the radial profile of neutral density. Simultaneous measurements of electron density and temperature are done using CO{sub 2} interferometer, Thomson scattering, and triple probes diagnostics along with absolute D-alpha radiation. Abel inversion was performed to get the time dependent radial profile of the local D-alpha emission density. Neutral density profiles are obtained under different machine conditions of titanium deposition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Layout and results from the initial operation of the high-resolution x-ray imaging crystal spectrometer on the Large Helical Device

First results of ion and electron temperature profile measurements from the x-ray imaging crystal spectrometer (XICS) diagnostic on the Large Helical Device (LHD) are presented. This diagnostic system has been operational since the beginning of the 2011 LHD experimental campaign and is the first application of the XICS diagnostic technique to helical plasma geometry. The XICS diagnostic provides measurements of ion and electron temperature profiles in LHD with a spatial resolution of 2 cm and a maximum time resolution of 5 ms (typically 20 ms). Ion temperature profiles from the XICS diagnostic are possible under conditions where charge exchange recombination spectroscopy (CXRS) is not possible (high density) or is perturbative to the plasma (low density or radio frequency heated plasmas). Measurements are made by using a spherically bent crystal to provide a spectrally resolved 1D image of the plasma from line integrated emission of helium-like Ar{sup 16+}. The final hardware design and configuration are detailed along with the calibration procedures. Line-integrated ion and electron temperature measurements are presented, and the measurement accuracy is discussed. Finally central temperature measurements from the XICS system are compared to measurements from the Thomson scattering and CXRS systems, showing excellent agreement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stationary density profiles in the Alcator C-mod tokamak

In the absence of an internal particle source, plasma turbulence will impose an intrinsic relationship between an inwards pinch and an outwards diffusion resulting in a stationary density profile. The Alcator C-mod tokamak utilizes RF heating and current drive so that fueling only occurs in the vicinity of the separatrix. Discharges that transition from L-mode to I-mode are seen to maintain a self-similar stationary density profile as measured by Thomson scattering. For discharges with negative magnetic shear, an observed rise of the safety factor in the vicinity of the magnetic axis appears to be accompanied by a decrease of electron density, qualitatively consistent with the theoretical expectations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Oblique shock structures formed during the ablation phase of aluminium wire array z-pinches

A series of experiments has been conducted in order to investigate the azimuthal structures formed by the interactions of cylindrically converging plasma flows during the ablation phase of aluminium wire array Z pinch implosions. These experiments were carried out using the 1.4 MA, 240 ns MAGPIE generator at Imperial College London. The main diagnostic used in this study was a two-colour, end-on, Mach-Zehnder imaging interferometer, sensitive to the axially integrated electron density of the plasma. The data collected in these experiments reveal the strongly collisional dynamics of the aluminium ablation streams. The structure of the flows is dominated by a dense network of oblique shock fronts, formed by supersonic collisions between adjacent ablation streams. An estimate for the range of the flow Mach number (M = 6.2-9.2) has been made based on an analysis of the observed shock geometry. Combining this measurement with previously published Thomson Scattering measurements of the plasma flow velocity by Harvey-Thompson et al.[Physics of Plasmas 19, 056303 (2012)] allowed us to place limits on the range of the ZT{sub e} of the plasma. The detailed and quantitative nature of the dataset lends itself well as a source for model validation and code verification exercises, as the exact shock geometry is sensitive to many of the plasma parameters. Comparison of electron density data produced through numerical modelling with the Gorgon 3D MHD code demonstrates that the code is able to reproduce the collisional dynamics observed in aluminium arrays reasonably well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Density of atoms in Ar*(3p{sup 5}4s) states and gas temperatures in an argon surfatron plasma measured by tunable laser spectroscopy

This study presents the absolute argon 1 s (in Paschens's notation) densities and the gas temperature, T{sub g}, obtained in a surfatron plasma in the pressure range 0.65 10 mbar, for which the pressure broadening can no more be neglected. T{sub g} is in the range of 480-750 K, increasing with pressure and decreasing with the distance from the microwave launcher. Taking into account the line of sight effects of the absorption measurements, a good agreement is found with our previous measurements by Rayleigh scattering of T{sub g} at the tube center. In the studied pressure range, the Ar(4 s) atom densities are in the order of 10{sup 16}-10{sup 18} m{sup -3}, increasing towards the end of the plasma column, decreasing with the pressure. In the low pressure side, a broad minimum is found around 10<p<20 mbar and hence the Ar(4 s) atom densities increase slightly with rising pressure. For the studied pressure range and all axial positions, the density ratio: 1s{sub 5}/1s{sub 4}/1s{sub 3} is very close to a Boltzmann equilibrium by electron impact mixing at the local T{sub e}, which was previously measured by Thomson scattering. The Ar(4 s) densities are successfully compared to a detailed Collisional Radiative Model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗