Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Contamination Measurements During Ius Thermal Vacuum Tests in A Large Space Chamber

The levels of contamination that originate from inside the IUS equipment support section (ESS) due to outgassing from electronics components and wiring operating at elevated temperatures (80-160 F) were investigated. Pressure was measured inside and outside the ESS. Mass deposition measurements were made with quartz crystal microbalances (QCM) facing into and away from ESS vents. The OCM's were operated at -50 C and -180 C using thermoelectrically and cryogenically cooled QCM's. Gaseous nitrogen flow inside the ESS was used to obtain the effective molecular flow vent area of the ESS, which was evaluated to be 359 sq cm (56 sq in) compared to the 978 sq cm (150 sq in) estimated by an earlier atmosphere pressure billowing test. The total outgassing rate of the ESS materials at a temperature of 60 C (140 F) decays with a time constant of 11.5 hours based on pressure measurements during the hot cycle. A time constant of 22 hours was estimated for the fraction of the outgassing which will condense on a -50 C surface. In contrast, the time constant is only 10.1 hours for the outgassing material which condenses on a surface at -180 C. A surface at -180 C collects approximately one half of the material vented from the ESS which impinges on it. Pressure measurements show very good correlation with the mass deposition measurements.

C R Mullen↗

Thermal stability tests of CFRP sandwich panels for far infrared astronomy

An account is given of fabrication methods and low temperature figure tests for CFRP sandwich panels, in order to ascertain their applicability to ultralightweight 3-m aperture primary mirrors for balloon-borne sub-mm and far-IF telescopes that must maintain a 1-2 micron rms surface figure accuracy at -40 to -50 C. Optical figure measurements on the first two of a series of four 0.5-m test panels, replicated to a spherical surface, show a radius-of-curvature change and astigmatism down to -60 C; this approximately follows the composite's theoretical predictions and implies that material and process control is excellent, so that the large scale changes observed can be compensated for.

Hoffmann, W. F.↗

Analysis of the thermal environment and thermal response associated with thermal-acoustic testing

A method is developed for predicting the radiant heat flux distribution produced by a bank of quartz radiant heaters which accounts for the specular and diffuse effects of a flat reflector or the diffuse effects of individual parabolic reflectors. This analysis is experimentally verified for a single unreflected lamp and a single lamp with a flat reflector. Observations on the further development of this analysis and experimental validation are discussed.

Turner, T. L.↗

Field testing of thermal canopy models in a spruce-fir forest

Recent advances in remote sensing technology allow the use of the thermal infrared region to gain information about vegetative surfaces. Extending existing models to account for thermal radiance transfers within rough forest canopies is of paramount importance. This is so since all processes of interest in the physical climate system and biogeochemical cycles are thermally mediated. Model validation experiments were conducted at a well established boreal forest; northern hardwood forest ecotone research site located in central Maine. Data was collected to allow spatial and temporal validation of thermal models. Emphasis was placed primarily upon enhancing submodels of stomatal behavior, and secondarily upon enhancing boundary layer resistance submodels and accounting for thermal storage in soil and vegetation.

Source record↗

Characterizing and testing a thermally isolating superconducting link for SAFIRE-like missions

The recent discovery of high temperature ceramic superconductors with transition temperatures above 90 K has opened the possibilities for new space applications. One application is the fabrication of an electrically conducting and thermally isolating electronic link to connect IR detectors to data acquisition electronics on remote sensing platforms. The Spectroscopy of the Atmosphere using Far Infra-Red Emission (SAFIRE) mission is an example of a platform which employs hybrid dewars and combines both mechanical and cryogenic liquid cooling. This new technology is limited by the heat conducted through sensor array leads that connect the electronics (at approximately 80 K) to the sensors (at approximately 4 K). This link must be made of material that has high electrical conductivity and high thermal resistance. The YBa2Cu3O(x) superconductor with a transition temperature, T(sub c), of 93 K can achieve these conflicting requirements. A link with these characteristics will improve the thermal isolation of IR detectors and will increase the lifetime of the cryogen. A reduction of the thermal load due to the link by a factor of four will increase the lifetime of a seven year mission by about one year.

Selim, Raouf L.↗

Cryogenic surface distortion and hysteresis of a 50 cm diameter fused silica mirror cooled to 77 K

A 50 cm diameter, lightweight, Amersil TO8E, fused-natural-quartz mirror with a single arch cross section was tested at the NASA/Ames Research Center Cryogenic Optics Test Facility to measure cryogenic distortion and hysteresis. The mirror was cooled to 77 K in four serial tests and the mirror figure was measured with a phase-measuring interferometer. On the basis of the repeatability of room temperature and cryogenic optical measurements, it was determined that the Single Arch Mirror had no measurable hysteresis and displayed repeatable cryogenic distortion. The Cryogenic Optics Test Facility, optical and thermal test methods, test results, and measurement accuracy are described.

Young, Jeffrey A.↗

Thermostructural responses of carbon phenolics in a restrained thermal growth test

The thermostructural response of carbon phenolic components in a solid rocket motor (SRM) is a complex process. It involves simultaneous heat and mass transfer along with chemical reactions in a multiphase system with time-dependent material properties and boundary conditions. In contrast to metals, the fracture of fiber-reinforced composites is characterized by the initiation and progression of multiple failures of different modes such as matrix cracks, interfacial debonding, fiber breaks, and delamination. The investigation of thermostructural responses of SRM carbon phenolics is further complicated by different failure modes under static and dynamic load applications. Historically, there have been several types of post-firing anomalies found in the carbon phenolic composites of the Space Shuttle SRM nozzle. Three major failure modes which have been observed on SRM nozzles are pocketing (spallation), ply-lift, and wedge-out. In order to efficiently control these anomalous phenomena, an investigation of fracture mechanisms under NASA/MSFC RSRM (Redesigned Solid Rocket Motor) and SPIP (Solid Propulsion Integrity Program) programs have been conducted following each anomaly. This report reviews the current progress in understanding the effects of the thermostructural behavior of carbon phenolics on the failure mechanisms of the SRM nozzle. A literature search was conducted and a technical bibliography was developed to support consolidation and assimilation of learning from the RSRM and SPIP investigation efforts. Another important objective of this report is to present a knowledge-based design basis for carbon phenolics that combines the analyses of thermochemical decomposition, pore pressure stresses, and thermostructural properties. Possible areas of application of the knowledge-based design include critical material properties development, nozzle component design, and SRM materials control.

Wang, C. Jeff↗

Damage Assessment of Creep Tested and Thermally Aged Udimet 520 Using Acousto-Ultrasonics

Due to elevated temperatures and excessive stresses, turbine components may experience creep behavior. As a result, it is desirable to monitor and assess the current condition of such components. This study employed the Acousto-Ultrasonics (AU) method in an effort to monitor the state of the material at various percentages of used up creep life in the nickel base alloy, Udimet 520. A stepped specimen (i.e., varying cross sectional area) was employed which allowed for a postmortem nondestructive evaluation (NDE) analysis of the various levels of used up life. The overall objectives here were two fold: First, a user friendly, graphical interface AU system was developed, and second the new AU system was applied as an NDE tool to assess distributed damage resulting from creep. The experimental results demonstrated that the AU method shows promise as an NDE tool capable of detecting material changes as a function of used up creep life. Furthermore, the changes in the AU parameters were mainly attributed to the case of combined load and elevated temperature (i.e., creep) and not simply because of a timed exposure at elevated temperature (i.e., heat treatment or thermal aging).

Gyekenyesi, Andrew L.↗

Comparison of Ultrasound with Tensile Testing of Thermally Damaged Polyimide Insulated Wiring (MIL-W-81381)

Ultrasonic measurements were performed on MIL-W-81381/7, /12, and /21 wire, a polyimide (Kapton) insulated wire. The phase velocity for the 20-gauge MIL-W-81381/7 wire had a baseline value of 3023 plus or minus 78 m/s. After exposure to high temperatures, the wire's phase velocity rapidly increased, and reached an asymptotic value of 3598 plus or minus 20 m/s after 100 hours exposure. Similar responses were measured in other gauges. The baseline measurements of Young's moduli resulted in values of 5636 plus or minus 486, 7714 plus or minus 505, and 8767 plus or minus 292 KSI for the 20 ga, 16 ga, and 12 ga. wires respectively.

Madaras, Eric I.↗

The Design of a Remotely Operated Shutter (ROS) for Thermal Vacuum Testing

Space-flight hardware is required to meet specific outgassing criteria under vacuum conditions in order to reduce the risk of contaminating sensitive optics and spacecraft components. Under certain circumstances, it is desirable to measure the contamination levels that are being released from all surfaces of the test payload. This certification is often accomplished with a Total Outgassing Measurement (TOM) box. The TOM box has one 103.2 square centimeter (16 square inch) opening and one 4.84 square centimeter (0.75 square inches) opening. The larger opening allows contaminants to easily escape the box during the hardware bakeout phase. The smaller opening provides a limited conductance path for outgassed contaminants during the certification phase. A Thermoelectric Quartz Crystal Microbalance (TQCM) monitors the contamination levels inside the box to provide the total outgassing measurement. During transition from the bakeout phase to the certification phase, the TOM box is reconfigured to close the larger opening. For previous certifications, the vacuum chamber was returned to ambient conditions and the larger conductance port was closed manually. The ROS system eliminates the need to enter the chamber by remotely closing the large TOM box opening. Substantial schedule and cost savings are achieved through the use of this system. The ROS system consists of three main components; a shutter, a motion actuator, and an actuator controller. Each of these components was selected or designed to operate in an extreme-temperature and vacuum environment while providing a high level of reliability. Different types of motion actuators were considered for driving the shutter. Design parameters for the actuator included material properties, force capability, reliability, and cost.

Hale, Kathleen L.↗

Apparatus and Method for Thermal Performance Testing of Pipelines and Piping Systems

A test apparatus and method of its use for evaluating various performance aspects of a piping segment locates a piping segment between two cold boxes. A first cold box conditions test fluid before providing the fluid into the piping segment- The first and second cold boxes both significantly reduce, if not eliminate, any heat transfer from the ends of the piping so that accurate measurements of heat leak rates from the sides of the piping segment may be determined.

Fesmire, James E.↗

A Passive Earth-Entry Capsule for Mars Sample Return

A combination of aerodynamic analysis and testing, aerothermodynamic analysis, structural analysis and testing, impact analysis and testing, thermal analysis, ground characterization tests, configuration packaging, and trajectory simulation are employed to determine the feasibility of an entirely passive Earth entry capsule for the Mars Sample Return mission. The design circumvents the potential failure modes of a parachute terminal descent system by replacing that system with passive energy absorbing material to cushion the Mars samples during ground impact. The suggested design utilizes a spherically blunted 45-degree half-angle cone forebody with an ablative heat shield. The primary structure is a hemispherical, composite sandwich enclosing carbon foam energy absorbing material. Though no demonstration test of the entire system is included, results of the tests and analysis presented indicate that the design is a viable option for the Mars Sample Return Mission.

Mitcheltree, Robert A.↗

A Passive Earth-Entry Capsule for Mars Sample Return

A combination of aerodynamic analysis and testing, aerothermodynamic analysis, structural analysis and testing, impact analysis and testing, thermal analysis, ground characterization tests, configuration packaging, and trajectory simulation are employed to determine the feasibility of an entirely passive Earth entry capsule for the Mars Sample Return mission. The design circumvents the potential failure modes of a parachute terminal descent system by replacing that system with passive energy absorbing material to cushion the Mars samples during ground impact. The suggested design utilizes a spherically blunted 45 degree half-angle forebody with an ablative heatshield. The primary structure is a spherical composite sandwich enclosing carbon foam energy absorbing material. Though no demonstration test of the entire system is included, results of the testing and analysis presented indicate that the design is a viable option for the Mars Sample Return Mission.

Mitcheltree, R. A.↗