Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Storage requirement definition study

A dish Stirling solar receiver (DSSR) and a heat pipe solar receiver with TES (HPSR) for a 25 kWe dish Stirling solar power system are described. The thermal performance and cost effectiveness of each are analyzed minute by minute over the equivalent of one year of solar insolation. Existing designs of these two systems were used as a basis for the study; TES concepts for the DSSR and alternative TES concepts for the HPSR are presented. Parametric performance and cost studies were performed to determine the operating and cost characteristics of these systems. Data are reported for systems (1) without TES and with varying amounts of TES, (2) with and without a fossil fuel combustor, (3) with varying solar to fossil power input, and (4) with different system control assumptions. The principal effects of TES duration, collector area, engine efficiency, and fuel cost sensitivity are indicated. Development needs for each of the systems are discussed and the need and nature of possible future TES solar modular experiments are presented and discussed.

Stacy, L. E.↗

Evaluation of a method for heat transfer measurements and thermal visualization using a composite of a heater element and liquid crystals

Commercially available elements of a composite consisting of a plastic sheet coated with liquid crystal, another sheet with a thin layer of a conducting material (gold or carbon), and copper bus bar strips were evaluated and found to provide a simple, convenient, accurate, and low-cost measuring device for use in heat transfer research. The particular feature of the composite is its ability to obtain local heat transfer coefficients and isotherm patterns that provide visual evaluation of the thermal performances of turbine blade cooling configurations. Examples of the use of the composite are presented.

Hippensteele, S. A.↗

Evaluation of a method for heat transfer measurements and thermal visualization using a composite of a heater element and liquid crystals

Commercially available elements of a composite consisting of a plastic sheet coated with liquid crystal, another sheet with a thin layer of a conducting material (gold or carbon), and copper bus bar strips were evaluated and found to provide a simple, convenient, accurate, and low-cost measuring device for use in heat transfer research. The particular feature of the composite is its ability to obtain local heat transfer coefficients and isotherm patterns that provide visual evaluation of the thermal performances of turbine blade cooling configurations. Examples of the use of the composite are presented.

Hippensteele, S. A.↗

Feasibility study for long lifetime helium dewar

A feasible concept for a launchable three year lifetime helium dewar was investigted. Current helium dewar designs were examined to see where the largest potential reductions in parasitic heat loads can be made. The study was also devoted to examining support concepts. The support concept chosen, a passive orbital disconnect strut (PODS), has an orbital support conductance that is lower by more than an order of magnitude over current tension band supports. This lower support conductance cuts the total dewar weight in half for the same three year life time requirements. Effort was also concentrated on efficient wire feed through designs and vapor cooling of the multilayer insulation, supports, wire feed throughs and plumbing penetrations. A single stage helium dewar vs. dual stage dewars with a guard cryogen of nitrogen or neon was examined. The single stage dewar concept was selected. Different support concepts were analyzed from which the PODS support concepts was chosen. A preliminary design of the dewar was thermally and structurally analyzed and laid out including system weights, thermal performance and performance sensitivities.

Parmley, R. T.↗

Dish-mounted latent heat buffer storage

Dish-mounted latent heat storage subsystems for Rankine, Brayton, and Stirling engines operating at 427 C, 816 C, and 816 C respectively are discussed. Storage requirements definition, conceptual design, media stability and compatibility tests, and thermal performance analyses are considered.

Manvi, R.↗

NECAP 4.1: NASA's Energy-Cost Analysis Program input manual

The computer program NECAP (NASA's Energy Cost Analysis Program) is described. The program is a versatile building design and energy analysis tool which has embodied within it state of the art techniques for performing thermal load calculations and energy use predictions. With the program, comparisons of building designs and operational alternatives for new or existing buildings can be made. The major feature of the program is the response factor technique for calculating the heat transfer through the building surfaces which accounts for the building's mass. The program expands the response factor technique into a space response factor to account for internal building temperature swings; this is extremely important in determining true building loads and energy consumption when internal temperatures are allowed to swing.

Jensen, R. N.↗

Thermal management of instruments on space platforms using a high capacity two-phase heat transport system

A system utilizing a pumped, two-phase single component working fluid for heat exchange and transport services necessary to meet the temperature control requirements of typical orbiting instrument payloads on space platforms is described. The design characteristics of the system is presented, together with a presentation of a laboratory apparatus for demonstration of proof of concept. Results indicate that the pumped two-phase design concept can meet a wide range of thermal performance requirements with the only penalty being the requirement for a small liquid pump.

Ollendorf, S.↗

A high temperature ceramic heat exchanger element for a solar thermal receiver

The development of a high-temperature ceramic heat exchanger element to be integrated into a solar receiver producing heated air was studied. A number of conceptual designs were developed for heat exchanger elements of differing configuration. These were evaluated with respect to thermal performance, pressure drop, structural integrity, and fabricability. The final design selection identified a finned ceramic shell as the most favorable concept. The shell is surrounded by a larger metallic shell. The flanges of the two shells are sealed to provide a leak-tight pressure vessel. The ceramic shell is to be fabricated by a innovative combination of slip casting the receiver walls and precision casting the heat transfer finned plates. The fins are bonded to the shell during firing. The unit is sized to produce 2150 F air at 2.7 atm pressure, with a pressure drop of about 2 percent of the inlet pressure. This size is compatible with a solar collector providing a receiver input of 85 kw(th). Fabrication of a one-half scale demonstrator ceramic receiver was completed.

Strumpf, H. J.↗

The 15-meter diameter mechanically scanned deployable antenna

A preliminary design with structural model data and thermal-performance estimates of a 15-meter mechanically scanned deployable antenna (MSDA) that could be launched onboard a Shuttle Orbiter to provide radiometric brightness temperature maps of the Earth and oceans in selected bands over a frequency range from 1.4 to 11 GHz is provided. The study objectives were met through the design of a unique, integrated, offset feed mast and reflector design that uses the deployable box-truss structure as a building block. The performance of this system is summarized. The all graphite-epoxy, 4.57-meter prototype cube that was completed in 1981 and is proposed for this reflector and feed mast design is presented.

Coyner, J. V.↗

High-temperature ceramic heat exchanger element for a solar thermal receiver

A study has been completed on the development of a high-temperature ceramic heat exchanger element to be integrated into a solar reciver producing heated air. A number of conceptual designs were developed for heat exchanger elements of differing configuration. These were evaluated with respect to thermal performance, pressure drop, structural integrity, and fabricability. The final design selection identified a finned ceramic shell as the most favorable concept. The ceramic shell is surrounded by a larger metallic shell. The flanges of the two shells are sealed to provide a leak-tight pressure vessel. The ceramic shell is fabricated by an innovative combination of slip casting the receiver walls and precision casting the heat transfer finned plates. The fins are bonded to the shell during firing. Fabrication of a one-half scale demonstrator ceramic receiver has been completed.

Strumpf, H. J.↗

Heat transfer and pressure drop in blade cooling channels with turbulence promoters

Repeated rib roughness elements have been used in advanced turbine cooling designs to enhance the internal heat transfer. Often the ribs are perpendicular to the main flow direction so that they have an angle-of-attack of 90 deg. The objective of the project was to investigate the effect of rib angle-of-attack on the pressure drop and the average heat transfer coefficients in a square duct with two opposite rib-roughned walls for Reynolds number varied from 8000 to 80,000. The rib height-to-equivalent diameter ratio (e/D) was kept at a constant value of 0.063, the rib pitch-to-height ratio (P/e) was varied from 10 to 20, and the rib angle-of-attack (alpha) was varied from 90 deg to 60 deg to 45 deg to 30 deg respectively. Two types of entrance conditions were examined, namely, long duct and sudden contraction. The heat transfer coefficient distribution on the smooth side wall and the rough side wall at the entrance and the fully developed regions were measured. Thermal performance comparison indicated that the pumping power requirement for the rib with an oblique angle to the flow (alpha = 45 deg to 30 deg) was about 20 to 50 percent lower than the rib with a 90 deg angle to the flow for a given heat transfer duty.

Han, J. C.↗

Solar Pond Overview

The term solar pond is used to refer specifically to a salt-gradient solar pond. A technology assessment was done consisting of thermal performance; maintenance; applications; and economics. Research needs and recommendations were also included.

French, R. L.↗

Review of SERI Solar Pond Work

Development of models of pond thermal performance; analysis of solar pond use for building space heat and hot water production; use of low-temperature pond-produced heat for industrial processes, desalination, and electricity production; development of direct-contact heat exchanger to reduce conversion equipment cost; determination of effects of extracted heat and mass from the storage layer on pond performance; and investigation of factors which determine gradient layer stability and the stability of this interface between this level and the upper and lower convecting layers were described.

Zangrando, F.↗

Results of tests of K5NA and a revised formulation of EPDM/cork patch material in MSFC Hot Gas Facility

During prelaunch procedures at Kennedy Space Center some of the EPDM Thermal Protection System material was damaged on the Solid Rocket Booster stiffener stubs. The preferred solution was to patch the damaged areas with a cork-filled epoxy patching compound. Before this was done, however, it was requested that this patching technique be checked out by testing it in the MSFC Hot Gas Facility. Two tests were run in the HFG in 1980. The results showed the patch material to be adequate. Since that time, the formulation of the cork-filled epoxy material has been changed. It became necessary to retest this concept to be sure that the new material is as good as or better than the original material. In addition to the revised formulation material, tests were also made using K5NA as the patch material. The objectives of the tests reported herein were to: (1) compare the thermal performance of the original and the new cork-filled epoxy formulations, and (2) compare the K5NA closeout material to these epoxy materials. Material specifications are also discussed.

Dean, W. G.↗

STS 41-D Solar Array Flight Experiment

The Solar Array Flight Experiment (SAFE) developed under the direction of the Marshall Space Flight Center, scheduled for launch on STS 41-D, will demonstrate a lightweight solar array technology which offers a factor of 3 improvement in weight and a factor of 10 improvement in specific volume over solar array systems currently in use in the space program. The experiment, which will include multiple deployment and retraction demonstration, verification of electrical and thermal performance, and verification of structural dynamic math models is 15 feet by 105 feet in size and, if completely covered with solar cells, would produce approximately 12.5 kW of electrical power. The unit has now been developed, tested, and is at Kennedy Space Center (KSC) being prepared for launch.

Turner, G. F.↗

Composite material technology requirements for large precision space structures

The development of dimensionally stable, precision composite structures has been recognized as a high risk technology driver in NASA's continuing large space structures research. Attempts are being made to understand the influences controlling thermal performance in such composites, and specifically in composite sandwich panels. The necessary tools for such composite panels' deployment, the experimental verification of analytical predictions, and the demonstration of technology in small scale hardware, are presently addressed.

Mcelroy, P. M.↗

Heat transfer enhancement in channels with turbulence promoters

Repeated rib-roughness elements have been used in advanced turbine cooling designs to enhance the internal heat transfer. Often the ribs are perpendicular to the main flow direction so that they have an angle-of-attack of 90 degrees. The objective of this investigation was to determine the effect of rib angle-of-attack on the pressure drop and the average heat-transfer coefficients in the fully developed turbulent air flow in a square duct with two opposite rib-roughened walls for Reynolds numbers varied from 7,000 to 90,000. The rib height-to-equivalent diameter ratio was kept at a constant value of 0.063, the rib pitch-to-height ratio was varied from 10 to 20, and the rib angle-of-attack (alpha) was varied from 90 to 60 deg to 45 to 30 deg, respectively. The thermal-performance comparison indicated that the increased heat conductance for the rib with an oblique angle to the flow (alpha = 45 deg - 30 deg) was about 10-20 percent higher than the rib with a 90 deg angle to the flow, and the pumping power requirement for the angled rib was about 20-50 percent lower than the transverse rib. Semi-empirical correlations for friction factor and heat-transfer coefficients were developed to account for rib spacing and rib angle. The correlations can be used in the design of turbine-blade cooling passages.

Han, J. C.↗

Results of apparent atomic oxygen reactions with spacecraft materials during shuttle flight STS-41G

The effect of atomic oxygen interaction experienced by polymeric-based spacecraft materials is described. An experimental package (ACOMEX) flown on shuttle mission STS-41G carried out the investigation of advanced composite specimens such as carbon-epoxy and Kevlar-epoxy both with and without protective coatings added to thermal protective paints and films. Information on the exposure environment of the specimens was provided by a carbon coated atomic oxygen fluence monitor together with a photographic record. Mass loss measurements and photomicrographs made possible the analysis of the effect of interaction. After a total of about 38 hours of equivalent normal exposure at 225 km altitude the results showed that unprotected exposed surfaces exhibited severe erosion and mass loss with the possibility of seriously degrading structural and thermal performance. However, the specimens with a thin fluorocarbon overcoat showed promise of providing a protective barrier to the attack without altering the base properties of the material.

Zimcik, D. G.↗