Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Modular Engine Instrumentation System

System that provides information and measurements never obtained before in real time has been developed. System shows not only real-time measurements but also results of computations of key combustion parameters in meaningful and easily understood display. Standard commercially-available shaft encoder plus data from pressure transducer act as principal drivers to device. Eventually, modular system could be developed into onboard controller for automobile engines.

Rice, W. J.↗

Half-life and magnetic moment of the first excited state in {sup 132}I

The half-life and the magnetic moment were measured for the first excited state in {sup 132}I, of which the inconsistent results on the half-life have been reported by several other groups. This time, measurements were performed on {sup 132}I obtained as a decay product of a {sup 132}Te radioactive beam from the ion guide at Tohoku University. The half-life of this level was determined to be T{sub 1/2}=1.120{+-}0.015 ns using a conventional coincidence technique with a pair of BaF{sub 2} detectors. The time-differential perturbed angular correlation technique was successfully applied to the first excited state in {sup 132}I implanted into nickel foils. The magnetic moment of this state was determined to be {mu}=+(2.06{+-}0.18){mu}{sub N}. The present results are consistent with values reported by Gorodetzky et al. and Singh et al.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cerium-doped barium halide scintillators for x-ray and {gamma}-ray detections

Single crystals of Ce-activated BaCl{sub 2}, BaBr{sub 2}, and BaI{sub 2} were investigated under x-ray and {gamma}-ray excitation. The Ce{sup 3+}-related x-ray excited luminescence in BaBr{sub 2} shifts significantly to longer wavelengths upon increasing the doping level from 0.1% to 1%. In Ce-activated BaCl{sub 2} only a slight shift can be observed. BaI{sub 2} does not show any Ce{sup 3+}-related emission. Scintillation decay time measurements show that the decay in BaBr{sub 2} is delayed due to migration processes. Additional K doping has a large influence on the scintillation decay time properties but not on the overall efficiency.

36 MATERIALS SCIENCE↗

Organic light emitting diodes (OLEDS) and OLED-based structurally integrated optical sensors

General introduction to OLED basics and OLED-based structurally integrated sensors was provided in chapter 1 and chapter 2. As discussed in chapter 3, OLEDs were developed or improved using novel engineering methods for better charge injection (increased by over 1 order of magnitude) and efficiency. As the excitation sources, these OLEDs have preferred characteristics for sensor applications, including narrowed emission, emission at desired wavelength, and enhanced output for reduced EL background, higher absorption and improved device lifetime. In addition to OLEDs with desired performance, sensor integration requires oxidase immobilization with the sensor film for O 2 -based biological and chemical sensing. Nanoparticles such as ZnO have large surface area and high isoelectric point (~9.5), which favors enzyme immobilization via physical adsorption as well as Coulombic bonding. In chapter 4, it was demonstrated that ZnO could be used for this purpose, although future work is needed to further bond the ZnO to the sensor film. In chapter 5, single unit sensor was extended to multianalyte parallel sensing based on an OLED platform, which is compact and integrated with silicon photodiodes and electronics. Lactate and glucose were simultaneously monitored with a low limit of detection 0.02 mM, fast response time (~1 minute) and dynamic range from 0-8.6 ppm of dissolved oxygen. As discovered in previous work, the dynamic range covers 0-100% gas phase O 2 or 0-40 ppm dissolved oxygen at room temperature. PL decay curve, which is used to extract the decay time, is usually not a simple exponential at high O 2 concentration, which indicates that O 2 is not equally accessible for different luminescent sites. This creates a challenge for data analysis, which however was successfully processed by stretched exponential as shown in chapter 6. This also provides an insight about the distribution of O 2 :dye collisional quenching rate due to microheterogeneity. Effect of TiO 2 doping was also discussed. Stretched exponential analysis also generates calibration curves with higher sensitivity, which is preferred from the operational point of view. The work of enhanced integration was shown in chapter 7 with a polymer photodetector, which enables the preferred operation mode, decay time measurement, due to fast reponse (<20 μs). Device thickness was enlarged for maximum absorption of the PL, which was realized by slow spincoating rate and shorter spincoating time. Film prepared this way shows more crystalline order by Raman spectra, probably due to slow evaporation. This also ensures charge transport is not affected even with a thick film as indicated in the response time. Combination of OLEDs and polymer photodetectors present opportunities for solution processed all-organic sensors, which enables cheap processing at large scale. Future development can focus on monolithically integration of OLEDs and organic photodetectors (OPD) on the same substrate at a small scale, which could be enabled by inkjet printing. As OLED and OPD technologies continue to advance, small-sized, flexible and all-organic structurally integrated sensor platforms will become true in the near future.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

{sup 1}H nuclear magnetic resonance study of hydrated water dynamics in perfluorosulfonic acid ionomer Nafion

We have studied the dynamics of hydrated water molecules in the proton exchange membrane of Nafion by means of high-resolution {sup 1}H nuclear magnetic resonance (NMR) measurements. “Bound” and “free” states of hydrated water clusters as well as the exchange protons were identified from the NMR chemical shift measurements, and their activation energies were obtained from the temperature-dependent laboratory- and rotating-frame spin-lattice relaxation measurements. Besides, a peculiar motional transition in the ultralow frequency region was observed at 373 K for the “free” hydrated water from the rotating-frame NMR spin-lattice relaxation time measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Aerosol Measurements by the Globally Distributed Micro Pulse Lidar Network

Full time measurements of the vertical distribution of aerosol are now being acquired at a number of globally distributed MP (micro pulse) lidar sites. The MP lidar systems provide full time profiling of all significant cloud and aerosol to the limit of signal attenuation from compact, eye safe instruments. There are currently eight sites in operation and over a dozen planned. At all sited there are also passive aerosol and radiation measurements supporting the lidar data. Four of the installations are at Atmospheric Radiation Measurement program sites. The network operation includes instrument operation and calibration and the processing of aerosol measurements with standard retrievals and data products from the network sites. Data products include optical thickness and extinction cross section profiles. Application of data is to supplement satellite aerosol measurements and to provide a climatology of the height distribution of aerosol. The height distribution of aerosol is important for aerosol transport and the direct scattering and absorption of shortwave radiation in the atmosphere. Current satellite and other data already provide a great amount of information on aerosol distribution, but no passive technique can adequately resolve the height profile of aerosol. The Geoscience Laser Altimeter System (GLAS) is an orbital lidar to be launched in early 2002. GLAS will provide global measurements of the height distribution of aerosol. The MP lidar network will provide ground truth and analysis support for GLAS and other NASA Earth Observing System data. The instruments, sites, calibration procedures and standard data product algorithms for the MPL network will be described.

Spinhirne, James↗

Propulsion Velocity and ETT on Biomagnetic Assessment of the Human Esophagus

Esophagus transit time measurement is a common clinical practical. Biomagnetic techniques and modern instrumentation can perform non invasive and functional assessments of the gastrointestinal tract. This study presents the evaluation of the esophagus transit time and propulsion velocity of a magnetic marker from the mouth to stomach using water vs. a swallow easy substance recently patented. A group of ten healthy subjects from 45 to 55 years, were evaluated in identical conditions for two times, they ingested randomly a magnetic marker in an anatomical body position of 45 deg., one times with water and the other one with a patented substance developed in order to help the subjects to swallow pills. The esophagus transit time was shorter when the subjects ingested the magnetic marker with the swallow easy substance than they ingested the magnetic marker with same quantity of water.

60 APPLIED LIFE SCIENCES↗

Interpreting the Strongly Lensed Supernova iPTF16geu: Time Delay Predictions, Microlensing, and Lensing Rates

We present predictions for time delays between multiple images of the gravitationally lensed supernova, iPTF16geu, which was recently discovered from the intermediate Palomar Transient Factory (iPTF). As the supernova is of Type Ia where the intrinsic luminosity is usually well known, accurately measured time delays of the multiple images could provide tight constraints on the Hubble constant. According to our lens mass models constrained by the Hubble Space Telescope F814W image, we expect the maximum relative time delay to be less than a day, which is consistent with the maximum of 100 hr reported by Goobar et al. but places a stringent upper limit. Furthermore, the fluxes of most of the supernova images depart from expected values suggesting that they are affected by microlensing. The microlensing timescales are small enough that they may pose significant problems to measure the time delays reliably. Our lensing rate calculation indicates that the occurrence of a lensed SN in iPTF is likely. However, the observed total magnification of iPTF16geu is larger than expected, given its redshift. This may be a further indication of ongoing microlensing in this system.

79 ASTRONOMY AND ASTROPHYSICS↗

SHAPES - Spatial, high-accuracy, position-encoding sensor

Future space systems will require control sensors capable of real-time measurements of position coordinates of many structural locations. Applications for such a sensor include figure and vibration control, rendezvous and docking, and structure assembly verification. The paper discusses an experimental study of SHAPES (spatial, high-accuracy, position-encoding sensor), a 3D position sensor that provides range and two angular positions of laser-illuminated retroreflector targets that mark the locations to be measured. Simultaneous range measurements to multiple targets by a time-of-flight corelation of short laser pulses are made with a CCD-equipped streak tube. Angular positions are measured with a CCD camera. Position measurements of 24 targets with sub-millimeter range accuracy at a 10 Hz update rate have been demonstrated.

Nerheim, Noble M.↗

Time operators in stroboscopic wave-packet basis and the time scales in tunneling

We demonstrate that the time operator that measures the time of arrival of a quantum particle into a chosen state can be defined as a self-adjoint quantum-mechanical operator using periodic boundary conditions and applied to wave functions in energy representation. The time becomes quantized into discrete eigenvalues; and the eigenstates of the time operator, i.e., the stroboscopic wave packets introduced recently [Phys. Rev. Lett. 101, 046402 (2008)], form an orthogonal system of states. The formalism provides simple physical interpretation of the time-measurement process and direct construction of normalized, positive definite probability distribution for the quantized values of the arrival time. The average value of the time is equal to the phase time but in general depends on the choice of zero time eigenstate, whereas the uncertainty of the average is related to the traversal time and is independent of this choice. The general formalism is applied to a particle tunneling through a resonant tunneling barrier in one dimension.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The wavefront of the radio signal emitted by cosmic ray air showers

Analyzing measurements of the LOPES antenna array together with corresponding CoREAS simulations for more than 300 measured events with energy above 10{sup 17} eV and zenith angles smaller than 45{sup o}, we find that the radio wavefront of cosmic-ray air showers is of approximately hyperbolic shape. The simulations predict a slightly steeper wavefront towards East than towards West, but this asymmetry is negligible against the measurement uncertainties of LOPES. At axis distances ∼> 50 m, the wavefront can be approximated by a simple cone. According to the simulations, the cone angle is clearly correlated with the shower maximum. Thus, we confirm earlier predictions that arrival time measurements can be used to study the longitudinal shower development, but now using a realistic wavefront. Moreover, we show that the hyperbolic wavefront is compatible with our measurement, and we present several experimental indications that the cone angle is indeed sensitive to the shower development. Consequently, the wavefront can be used to statistically study the primary composition of ultra-high energy cosmic rays. At LOPES, the experimentally achieved precision for the shower maximum is limited by measurement uncertainties to approximately 140 g/c {sup 2}. But the simulations indicate that under better conditions this method might yield an accuracy for the atmospheric depth of the shower maximum, X{sub max}, better than 30 g/c {sup 2}. This would be competitive with the established air-fluorescence and air-Cherenkov techniques, where the radio technique offers the advantage of a significantly higher duty-cycle. Finally, the hyperbolic wavefront can be used to reconstruct the shower geometry more accurately, which potentially allows a better reconstruction of all other shower parameters, too.

79 ASTRONOMY AND ASTROPHYSICS↗

National Ignition Facility (NIF) Neutron time-of-flight (nTOF) Measurements

The first three of eighteen neutron time-of-flight (nTOF) channels have been installed at the National Ignition Facility (NIF). The role of these detectors includes yield, temperature, and bang time measurements. This article focuses on nTOF data analysis and quality of results obtained for the first set of experiments to use all 192 NIF beams. Targets produced up to 2 x 10{sup 10} 2.45-MeV neutrons for initial testing of the nTOF detectors. Differences in neutron scattering at the OMEGA laser facility where the detectors were calibrated and at NIF result in different response functions at the two facilities. Monte Carlo modeling shows this difference. The nTOF performance on these early experiments indicates the nTOF system with its full complement of detectors should perform well in future measurements of yield, temperature, and bang time.

36 MATERIALS SCIENCE↗

Neutron Rodeo Phase II Final Report

The ability to perform nondestructive assay (NDA) of fresh fuel assemblies with high precision in reasonable measurement times is significant for nuclear nonproliferation and safeguards. The current methodology used by the International Atomic Energy Agency (IAEA) for NDA of fresh fuel assemblies involves a He-3 based Uranium Neutron Collar (UNCL) system, which is an active coincidence counting system designed to measure time-correlated neutron doubles from induced fissions within the assembly. The UNCL system provides an easily implementable process of quantifying the 235 U linear density of the fresh fuel assemblies; however, operational limitations of the UNCL include long assay times and adverse sensitivity to poisoned assemblies. This has engendered investigation in alternative detector materials for fast-neutron counting to rectify some of these current limitations in the UNCL. The potential improvements of using fast-neutron organic scintillators (e.g. liquid scintillators, stilbene, PSDcapable plastics, etc.) was compared directly to the original Uranium Neutron Collar (UNCL) in-detail during the initial Advanced Neutron Detection Technology Rodeo. The simulation results showed that these alternative detector materials can provide an improvement in the assay time required to reach a suitable precision due to both their lower sensitivity to the interrogation source neutrons (i.e. AmLi neutrons) and their inherently shorter coincidence gate widths. The IAEA has developed a liquid scintillator-based Fast-Neutron Collar (FNCL) as a potential replacement system for the UNCL.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fast frequency acquisition via adaptive least squares algorithm

A new least squares algorithm is proposed and investigated for fast frequency and phase acquisition of sinusoids in the presence of noise. This algorithm is a special case of more general, adaptive parameter-estimation techniques. The advantages of the algorithms are their conceptual simplicity, flexibility and applicability to general situations. For example, the frequency to be acquired can be time varying, and the noise can be nonGaussian, nonstationary and colored. As the proposed algorithm can be made recursive in the number of observations, it is not necessary to have a priori knowledge of the received signal-to-noise ratio or to specify the measurement time. This would be required for batch processing techniques, such as the fast Fourier transform (FFT). The proposed algorithm improves the frequency estimate on a recursive basis as more and more observations are obtained. When the algorithm is applied in real time, it has the extra advantage that the observations need not be stored. The algorithm also yields a real time confidence measure as to the accuracy of the estimator.

Kumar, R.↗