Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TANK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Transuranic Waste Processing Center (TWPC) Legacy Tank RH-TRU Sludge Processing and Compliance Strategy - 13255

The U.S. Department of Energy (DOE) needs to safely and efficiently treat its 'legacy' transuranic (TRU) waste and mixed low-level waste (LLW) from past research and defense activities at the Oak Ridge National Laboratory (ORNL) so that the waste is prepared for safe and secure disposal. The TWPC operates an Environmental Management (EM) waste processing facility on the Oak Ridge Reservation (ORR). The TWPC is classified as a Hazard Category 2, non-reactor nuclear facility. This facility receives, treats, and packages low-level waste and TRU waste stored at various facilities on the ORR for eventual off-site disposal at various DOE sites and commercial facilities. The Remote Handled TRU Waste Sludge held in the Melton Valley Storage Tanks (MVSTs) was produced as a result of the collection, treatment, and storage of liquid radioactive waste originating from the ORNL radiochemical processing and radioisotope production programs. The MVSTs contain most of the associated waste from the Gunite and Associated Tanks (GAAT) in the ORNL's Tank Farms in Bethel Valley and the sludge (SL) and associated waste from the Old Hydro-fracture Facility tanks and other Federal Facility Agreement (FFA) tanks. The SL Processing Facility Build-outs (SL-PFB) Project is integral to the EM cleanup mission at ORNL and is being accelerated by DOE to meet updated regulatory commitments in the Site Treatment Plan. To meet these commitments a Baseline (BL) Change Proposal (BCP) is being submitted to provide continued spending authority as the project re-initiation extends across fiscal year 2012 (FY2012) into fiscal year 2013. Future waste from the ORNL Building 3019 U-233 Disposition project, in the form of U-233 dissolved in nitric acid and water, down-blended with depleted uranyl nitrate solution is also expected to be transferred to the 7856 MVST Annex Facility (formally the Capacity Increase Project (CIP) Tanks) for co-processing with the SL. The SL-PFB project will construct and install the necessary integrated systems to process the accumulated MVST Facilities SL inventory at the TWPC thus enabling safe and effective disposal of the waste. This BCP does not include work to support current MVST Facility Surveillance and Maintenance programs or the ORNL Building 3019 U-233 Disposition project, since they are not currently part of the TWPC prime contract. The purpose of the environmental compliance strategy is to identify the environmental permits and other required regulatory documents necessary for the construction and operation of the SL- PFB at the TWPC, Oak Ridge, TN. The permits and other regulatory documents identified are necessary to comply with the environmental laws and regulations of DOE Orders, and other requirements documented in the SL-PFB, Safety Design Strategy (SDS), SL-A-AD-002, R0 draft, and the Systems, Function and Requirements Document (SFRD), SL-X-AD-002, R1 draft. This compliance strategy is considered a 'living strategy' and it is anticipated that it will be revised as design progresses and more detail is known. The design basis on which this environmental permitting and compliance strategy is based is the Wastren Advantage, Inc., (WAI), TWPC, SL-PFB (WAI-BL-B.01.06) baseline. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Grout testing to support tank closure at the Savannah River Site - 15370

Final operational closure of the Savannah River Site (SRS) waste tanks is performed by filling the voids inside the tanks with a series of tailored grout formulas thereby stabilizing the remaining residuals. These tailored grout formulas were each developed to meet the demands of the closure process. The needs identified for the closure process include (1) a flowable, self-consolidating, reducing grout for tank fill, (2) a highly flowable grout capable of filling the 7-1/4 kilometers (4-1/2 miles) of 5-centimeter (2-inch) diameter cooling coils inside the tank, and (3) a highly flowable grout capable of filling equipment remaining in the tank. The specific characteristics of each of the grout formulations were tested to ensure they would function as required during implementation. Performance testing was also done on some of the grout formulations to confirm mix effectiveness and improve worker handling proficiency and conducted additional testing on the bulk fill grout to expand the placement capabilities of the grout. This paper focuses on the evolution of the closure process' identified needs, formulation development, and the subsequent testing of the tailored grout formulations utilized in the past tank closure processes at SRS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

3D Sonar for tank waste quantification - 15430

An innovative remote 3D Sonar technology adapted from the oil and gas industry has been successfully applied to the mapping of radioactive sludge deposits during tank, fuel pool and silo remediation operations at the Sellafield site in the UK. The technology can: -Measure the disposition and calculate the volume of settled solids in a waste tank thereby supporting tank closure objectives - Produce accurate 3-D images of solids disposition, structure and tank internals to help identify where sludge deposits and debris are located -Capture real time 'Sonar video' of movement of solids in the tank in real time to aid retrieval - Detect and monitor gas release and bubble generation Aside from direct safety, cost and schedule benefits, improved accuracy and confidence in residual waste volume determinations can lead to increased level of regulator confidence in meeting closure objectives. This technology has potential to bring such benefits to challenges in the DOE estate, such as Savannah River Site (SRS) and Hanford Tank Farms remediation, and operations at the Hanford Waste Treatment Plant. This paper describes the 3D Sonar technology and its applications, and reviews a 3D Sonar demonstration project specifically aimed at enhancing retrieval and closure operations at SRS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford single-shell tank sidewall coring Project - 15548

As part of an enhanced Single-Shell Tank (SST) integrity project, Washington River Protection Solutions, the US DOE Hanford site Tank Operations Contractor, established an expert panel to provide recommendations for implementation of the project. In one of the main areas of interest, structural integrity, the panel recommended obtaining and testing a vertical core from the entire depth of the sidewall for SSTs that have leaked and have been operated at high temperatures for extended periods. Due to concerns over handling contaminated samples, the panel later recommended that the evaluation focus only on thermal degradation. SST 241-A-106 was selected as the best choice for sidewall coring based on heat exposure and other factors. During site preparation activities, nondestructive testing and evaluation of the exposed tank dome and sidewall was performed using impact echo, spectral analysis of surface waves, and sonic echo/impulse response acoustic wave test methods. Good results were observed in the tests performed on the dome, but results were inconclusive for the full wall height due to signal damping. Results indicated that no cracking was predicted in the upper wall. Sidewall coring of tank A-106 was completed over two weeks in May 2014. Over 38 feet of concrete core was successfully removed, to a depth approximately halfway through the tank footing. Nondestructive and destructive physical testing of the concrete core specimens was successfully performed and included visual examination and determination of transverse and longitudinal resonant frequency and dynamic modulus of elasticity; pulse velocity; static modulus of elasticity; Poisson's ratio; and compressive strength. The testing indicated favorable results with values generally greater, and in many cases significantly greater, than expected in comparison with the values originally specified and those used in the current structural analysis of record. Petrographic analysis was performed to assess the quality and condition of the concrete and the extent of any deterioration or deleterious reactions occurring within the concrete, and determined that the concrete within the examined core segments is in overall good condition, with a minor amount of microcracking and minor evidence of deleterious mechanisms that do not appear to have significantly affected the overall quality and integrity of the concrete. The results of the testing performed on the concrete core removed from the sidewall of SST 241-A-106 do not reveal any deficiencies with the structural integrity of the tank. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PHOENIX - Web-Based Application for Accessing Hanford Tank Monitoring Data - 16157

Data volume, complexity, and access issues pose severe challenges for analysts, regulators, and stakeholders interested in evaluating scientific data to support decision making at the Department of Energy's (DOE) Hanford Site. Pacific Northwest National Laboratory (PNNL) has developed a suite of web applications known collectively as PHOENIX (PNNL-Hanford Online Environmental Information exchange) to address data access, transparency, and integration challenges through intuitive query, visualization, and analysis tools that are accessible via desktop computer or mobile device by simply accessing the application web page (http://phoenix.pnnl.gov). Beginning in 2013, DOE's Office of River Protection (ORP) has worked with PNNL to develop a PHOENIX Tank Farm application to provide access to, and visualization of, in-tank monitoring data that had only been available to the public as text downloads for almost two decades. The Tank Farm application's user-friendly web-interface allows the public, stakeholders, regulators, and program managers to quickly and easily visualize in-tank and ex-tank data, facilitating data transparency and high-level decisions related to tank operations and management. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Remote Geophysical Logging at the Hanford Single-Shell Tank Farms: Maintaining Efficiency and Reducing Personnel Hazards - 16190

Vadose zone characterization around groups of underground waste storage tanks (known as tank farms) at the US DOE Hanford Site in Washington State is conducted to assess the presence and extent of manmade gamma-ray emitting radionuclides. Boreholes around the tanks are characterized using a high-resolution spectral gamma logging system (SGLS). In the past, logging operations required workers to remain inside the tank farm boundary during data acquisition. This approach was effective; however, personnel were at risk of exposure to potential radiological hazards, chemical hazards, and/or vapor releases that can be associated with the tank farm environment. Limitations associated with this work environment necessitated a new approach in order to decrease the amount of time personnel spent in the farm without affecting work productivity and efficiency. In order to accomplish this, a new remote logging cable support (RLCS) was developed and implemented which effectively removed workers from the hazards associated with the tank farm environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Engineering Scale Testing of Robotic Inspection Tools for Double Shell Tanks at Hanford - 18349

Waste found in the annulus of the AY-102 double-shell tank (DST) at Hanford has prompted the need for the development of inspection tools that are able to access confined spaces around and underneath the tanks. During the last year, Florida International University (FIU) has been developing inspection tools that are capable of accessing the tank floors through the air supply line, the air refractory channels and the drain lines. This effort has led to the development of a pneumatic pipe crawler and a miniature rover. In this paper, updates to the inspection tool designs and the full scale testing of both systems are presented. The tools provide visual feedback for the operator, carrying with them onboard cameras and light sources. The images are streamed back live via a tether, which also provides power to the devices. To increase the sensing capabilities of both tools, temperature, humidity and radiation sensor modules are being integrated onto the developed systems, and can be interchanged depending on the inspection objectives. The miniature rover measures 7 cm in length and 3.8 cm in width, and travels upside down on the bottom of the tank to avoid debris accumulated in the channels. The video is also being processed real-time to provide control of the unit semi-autonomously. The pipe crawler measures approximately 76 cm in length and 6.4 cm in diameter, and travels using pneumatic actuators that emulate the peristaltic movement contractions typical of worm type robots. A full-scale sectional mock-up of the DST foundation, refractory system and annulus is currently being developed as a test-bed for the testing of the inspection tools. The intention of the test-bed is to demonstrate the viability of using both inspection tools in configurations similar to the actual tank. The test-bed includes a 2.43 m wide section of both tank liners, refractory channels and concrete foundation with drain slots. The test-bed is designed to be modular so that various plate thicknesses can be easily utilized and different refractory configurations can be incorporated. Currently, the refractory channels are of the tree type structure with turns that are approximately 30 degrees. Both inspection tools were demonstrated in the mock-up facility. The miniature rover ran successfully through the drain slots from the annulus to central plenum and had no issues making the 90-degree turns. The peristaltic crawler was able to navigate through the 7.62 cm air supply line from the annulus to the central plenum. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laboratory-Scale Melter Systems for Simulated and Real AP-105 Tank Waste - 19301

The Hanford Tank Waste Treatment and Immobilization Plant is being constructed to vitrify the nuclear waste stored in underground tanks on the Hanford Site. Through this conversion process, waste components become partitioned into one of two product streams: glass and off-gas, including condensate. A small-scale melter system is appropriate for analyzing the waste-to-glass process because it does not require the high volumes of input waste or resource commitment of a large-scale melter system while providing dynamic information that can be difficult to determine from batch reactions in a crucible system. A continuous laboratory-scale melter (CLSM) was sized to collect the relevant process and chemical information from obtainable volumes of Hanford tank waste and designed to operate with a continuous feeding process while periodically pouring glass product and collecting off-gas. Two CLSMs were constructed: one in a non-radioactive environment for processing waste simulants and another in a fume hood capable of handling radioactive material for processing actual Hanford tank waste. Multiple waste simulants were first tested in the non-radioactive CLSM to determine the processability and desired operating window for actual tank waste. About 12 liters of real waste from Hanford tank 241-AP-105 were received, filtered, and ion exchanged for removal of Cs-137. This quantity of waste was vitrified into 9.5 kg of glass product over the course of ∼15 hours of feeding to the CLSM. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Panel Session 61: Challenges in the US DOE HLW Tank Management Program

Approximately 50 people attended this panel session which focused on the successes and challenges in DOE high-level radioactive tank waste management with special emphasis on tank waste processing and waste disposition. Panelists discussed approaches, results, and lessons learned in addressing challenges in construction, start-up, and processing of tank waste and its ultimate disposition that is critical to tank waste management at Hanford, Savannah River, and Idaho sites. Presentations proposed include: 1 - Liquid Waste Program at the Savannah River Site (James Folk, US DOE (USA)); 2 - Progress on Hanford's Tank Waste Treatment Mission (Tom Fletcher, US DOE (USA)); 3 - Idaho Tank Waste Program (Joel Case, US DOE (USA))

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank Closure Cesium Removal at Savannah River Site - 19604

Savannah River Remediation (SRR) has developed a supplemental at-tank ion exchange capability for the removal of cesium from liquid salt waste. Building on the development of previous ion exchange initiatives and the experience of commercial nuclear plant decontamination services, and following the disaster response associated with Fukushima, the technology has matured to deploy a modular at-tank treatment system for the selective removal of cesium from bulk salt waste. If feasible, this Tank Closure Cesium Removal (TCCR) initiative would provide a supplemental treatment capability to existing and future salt processing and improve confidence in supporting the desired acceleration of waste retrieval and tank closure efforts. In addition to accelerating waste retrieval and tank closure activities, demonstration of this capability has several other benefits. Deployment of commercially available technologies with minor modification can expand Department of Energy (DOE) utilization of commercially supplied treatment processes. This 'at-tank' treatment system could be modified to evaluate and demonstrate removal of other radioactive constituents (strontium, technetium, iodine, etc.) of bulk waste. The modular aspect of this capability can allow for additional units to be delivered and deployed at SRS, as well as, provide supplemental treatment capabilities for waste treatment at other DOE sites. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Savannah River Site High Level Radioactive Waste Tank Sample Thermolytic Hydrogen Generation - 20346

To support the revision of flammability calculations and controls for the Savannah River Site (SRS) High-Level Radioactive Waste (HLW) tanks, Savannah River National Laboratory (SRNL) conducted laboratory measurements with the goal of quantifying hydrogen produced in HLW by non-radiolytic chemical reactions (i.e., thermolysis). Testing was performed with HLW tank supernate samples that represented a cross section of types of waste at SRS, including tanks that store typical evaporator concentrate, dissolved salt-cake, dilute recycle stream from the Defense Waste Processing Facility (DWPF), evaporator concentrate of the recycle stream from DWPF, fresh waste from the canyon separations facility, and waste that has been through salt processing cesium removal. Non-radioactive simulant testing included the classes of organic compounds historically introduced into the HLW tanks that were recently shown to be the most active toward the thermolytic generation of hydrogen. The reaction rate equations developed for thermolytic hydrogen generation from each class of organic compound showed direct proportionality to organic compound concentration and hydroxide concentration. Simulant testing identified that highly concentrated waste with high hydroxide concentration had the highest rates of thermolytic hydrogen generation. Using the radioactive tank sample thermolysis measurements at high temperatures and the mechanistic salt dependence of the simulant models, a global model was developed for tank waste thermolytic hydrogen generation as a function of total organic carbon content of SRS HLW. Through the primary functionality of the global model (organic carbon and free hydroxide concentration), the relative reactivity of the organic carbon in the waste was quantified. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of Cold Spraying Mild-Steel Powder onto Mild-Steel Substrate for Development of Waste Tank Repair System - 20515

Infrastructure for nuclear waste storage and processing (e.g., waste tanks, transfer pipelines, evaporators) at the U.S. Department of Energy (DOE) Hanford Site has been in service well beyond its original design life. Past corrosion control methods at Hanford for waste tanks have not been fully successful, as evidenced by leaks forming in tank AY-102, the first double-shell tank (DST) constructed, and significant degradation detected in the primary tanks of AP-102 and AY-101. Failure of infrastructure components can pose a significant risk to the environment, worker safety, and project schedules. Therefore, remotely deployable methods for repairing and extending the service life of the existing tank waste infrastructure are needed. Cold spray has been identified as a potential technique for performing in situ repairs and material buildup for life extension of waste storage and processing infrastructure. Cold-spray repair methods and technology are well-established and are used extensively by industry and the military for making repairs using dissimilar materials. Pacific Northwest National Laboratory is evaluating the process of making repairs using mild-steel powder applied to a mild-steel substrate to minimize the galvanic corrosion potential. This paper presents the initial results for a feasibility ('go/no-go') assessment as to whether low-density deposits with sound metallurgic bonds, to build-back steel plate material, can be achieved using existing commercial cold-spray equipment. An assessment of steel-on-steel deposit is necessary to determine if cold spray is a viable candidate for DST carbon steel plate restoration/repair and thus DST service life extension. Powder properties and preparation requirements have been investigated and operating conditions and parameters for depositing a cold-spray buildup of mild steel on a mild-steel substrate have been determined. Soundness of metallurgic bonding as a function of the operating parameters exercised and results from applying cold spray to lay a deposit over simulated small-diameter flaws in 1/2-inch mild-steel plate are presented. Application of in situ cold-spray repair to the DOE complex has the potential to reduce cost and schedule impacts associated with component failures and the need to procure and construct replacement infrastructure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RECENT PROGRESS IN DOE WASTE TANK CLOSURE

The USDOE complex currently has over 330 underground storage tanks that have been used to process and store radioactive waste generated from the production of weapons materials. These tanks contain over 380 million liters of high-level and low-level radioactive waste. The waste consists of radioactively contaminated sludge, supernate, salt cake or calcine. Most of the waste exists at four USDOE locations, the Hanford Site, the Savannah River Site, the Idaho Nuclear Technology and Engineering Center and the West Valley Demonstration Project. A summary of the DOE tank closure activities was first issued in 2001. Since then, regulatory changes have taken place that affect some of the sites and considerable progress has been made in closing tanks. This paper presents an overview of the current regulatory changes and drivers and a summary of the progress in tank closures at the various sites over the intervening six years. A number of areas are addressed including closure strategies, characterization of bulk waste and residual heel material, waste removal technologies for bulk waste, heel residuals and annuli, tank fill materials, closure system modeling and performance assessment programs, lessons learned, and external reviews.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sorption of Uranium, Plutonium and Neptunium onto Solids Present in High Caustic Nuclear Waste Storage Tanks

Solids such as granular activated carbon, hematite and sodium phosphates, if present as sludge components in nuclear waste storage tanks, have been found to be capable of precipitating/sorbing actinides like plutonium, neptunium and uranium from nuclear waste storage tank supernatant liqueur. Thus, the potential may exists for the accumulation of fissile materials in such nuclear waste storage tanks during lengthy nuclear waste storage and processing. To evaluate the nuclear criticality safety in a typical nuclear waste storage tank, a study was initiated to measure the affinity of granular activated carbon, hematite and anhydrous sodium phosphate to sorb plutonium, neptunium and uranium from alkaline salt solutions. Tests with simulated and actual nuclear waste solutions established the affinity of the solids for plutonium, neptunium and uranium upon contact of the solutions with each of the solids. The removal of plutonium and neptunium from the synthetic salt solution by nuclear waste storage tank solids may be due largely to the presence of the granular activated carbon and transition metal oxides in these storage tank solids or sludge. Granular activated carbon and hematite also showed measurable affinity for both plutonium and neptunium. Sodium phosphate, used here as a reference sorbent for uranium, as expected, exhibited high affinity for uranium and neptunium, but did not show any measurable affinity for plutonium.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Enhanced Chemical Cleaning: A New Process for Chemically Cleaning Savannah River Waste Tanks

At the Savannah River Site (SRS) there are 49 High Level Waste (HLW) tanks that eventually must be emptied, cleaned, and closed. The current method of chemically cleaning SRS HLW tanks, commonly referred to as Bulk Oxalic Acid Cleaning (BOAC), requires about a half million liters (130,000 gallons) of 8 weight percent (wt%) oxalic acid to clean a single tank. During the cleaning, the oxalic acid acts as the solvent to digest sludge solids and insoluble salt solids, such that they can be suspended and pumped out of the tank. Because of the volume and concentration of acid used, a significant quantity of oxalate is added to the HLW process. This added oxalate significantly impacts downstream processing. In addition to the oxalate, the volume of liquid added competes for the limited available tank space. A search, therefore, was initiated for a new cleaning process. Using TRIZ (Teoriya Resheniya Izobretatelskikh Zadatch or roughly translated as the Theory of Inventive Problem Solving), Chemical Oxidation Reduction Decontamination with Ultraviolet Light (CORD-UV{reg_sign}), a mature technology used in the commercial nuclear power industry was identified as an alternate technology. Similar to BOAC, CORD-UV{reg_sign} also uses oxalic acid as the solvent to dissolve the metal (hydr)oxide solids. CORD-UV{reg_sign} is different, however, since it uses photo-oxidation (via peroxide/UV or ozone/UV to form hydroxyl radicals) to decompose the spent oxalate into carbon dioxide and water. Since the oxalate is decomposed and off-gassed, CORD-UV{reg_sign} would not have the negative downstream oxalate process impacts of BOAC. With the oxalate destruction occurring physically outside the HLW tank, re-precipitation and transfer of the solids, as well as regeneration of the cleaning solution can be performed without adding additional solids, or a significant volume of liquid to the process. With a draft of the pre-conceptual Enhanced Chemical Cleaning (ECC) flowsheet, taking full advantage of the many CORD-UV{reg_sign} benefits, performance demonstration testing was initiated using available SRS sludge simulant. The demonstration testing confirmed that ECC is a viable technology, as it can dissolve greater than 90% of the sludge simulant and destroy greater than 90% of the oxalates. Additional simulant and real waste testing are planned.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Statistical Analysis of Tank 5 Floor Sample Results (U)

Sampling has been completed for the characterization of the residual material on the floor of Tank 5 in the F-Area Tank Farm at the Savannah River Site (SRS), near Aiken, SC. The sampling was performed by Savannah River Remediation (SRR) LLC using a stratified random sampling plan with volume-proportional compositing. The plan consisted of partitioning the residual material on the floor of Tank 5 into three non-overlapping strata: two strata enclosed accumulations, and a third stratum consisted of a thin layer of material outside the regions of the two accumulations. Each of three composite samples was constructed from five primary sample locations of residual material on the floor of Tank 5. Three of the primary samples were obtained from the stratum containing the thin layer of material, and one primary sample was obtained from each of the two strata containing an accumulation. This report documents the statistical analyses of the analytical results for the composite samples. The objective of the analysis is to determine the mean concentrations and upper 95% confidence (UCL95) bounds for the mean concentrations for a set of analytes in the tank residuals. The statistical procedures employed in the analyses were consistent with the Environmental Protection Agency (EPA) technical guidance by Singh and others [2010]. Savannah River National Laboratory (SRNL) measured the sample bulk density, nonvolatile beta, gross alpha, and the radionuclide1, elemental, and chemical concentrations three times for each of the composite samples. The analyte concentration data were partitioned into three separate groups for further analysis: analytes with every measurement above their minimum detectable concentrations (MDCs), analytes with no measurements above their MDCs, and analytes with a mixture of some measurement results above and below their MDCs. The means, standard deviations, and UCL95s were computed for the analytes in the two groups that had at least some measurements above their MDCs. The identification of distributions and the selection of UCL95 procedures generally followed the protocol in Singh, Armbya, and Singh [2010]. When all of an analyte's measurements lie below their MDCs, only a summary of the MDCs can be provided. The measurement results reported by SRNL are listed, and the results of this analysis are reported. The data were generally found to follow a normal distribution, and to be homogenous across composite samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Developing Science-based fueling protocols for 250-bar hydrogen tanks onboard hydrogen ferries: Experiments and modeling

Combined modeling and experimental studies are reported of the fueling of a large (28 kg capacity) 250-bar Type IV hydrogen tank of the type being deployed on early hydrogen ferries, such as the MV Sea Change. The primary goal was to determine how such tanks can be successfully fueled with hydrogen (state of charge greater than 97%) within 45 minutes without exceeding the 82 °C temperature limit for such tanks. The modeling studies show that a gas injector is needed to avoid thermal stratification during hydrogen fueling which can result in potential hot spots. Empirically, precooling of the hydrogen to 0 °C was found to be needed in some of the cases examined, as ambient conditions greatly affected the need for a precooling to achieve the 45-minute fill time desired by end users. The experimental results afforded a calibration of the engineering model SOFIL for these large 250-bar tanks, which now enables using SOFIL to predict volume-averaged hydrogen fueling temperatures to an accuracy of ±2.7°C for these tanks. The model can therefore be used to evaluate potential scenarios for development of a standardized fueling methodology for ferries utilizing large Type-IV tanks.

08 HYDROGEN↗

Thermal Insulation for a High Temperature Molten Salt Storage Tank in a CSP Plant

A ternary molten chloride has been suggested as a high temperature (550-720 °C) sensible heat storage medium for a two-tank system. An effective thermal insulation is proposed to provide an opportunity for the fabrication of both the hot and cold storage tanks from lower cost metals, e.g. A240-347H, by maintaining the tank wall below 500 °C. To achieve this, the hot storage tank mainly comprises of inner shell (11.4 cm of a refractory brick as liner (KX-99®), 30 cm of insulation brick) and outer metal shell, where 5 cm of frozen layer of PCM800 (NaCl), and 5 cm of ceramic wool fill the annular space between the shells. Another layer of ceramic wool was introduced at the outer side of the metal shell to keep the temperature lower than 60 °C. ANSYS Fluent was used for the numerical study of the cool down behavior of the system during idle period when tank is quarter-filled. The heat transfer modes were considered as radiation and natural convection heat transfer from the hot molten salt at 720 °C, conduction through the solid layers and convection heat transfer from the outer shell to the environment at 15 °C. The results showed that the proposed insulation system including a frozen layer of PCM800 maintains the temperature at the metal wall lower than 500 °C, and lower than 60°C at the outer side of the tank. Apart from the insulation property of the frozen layer of PCM800, it absorbs any leak of hot molten salt, acting as a barrier between salt and the metal shell. The thermal performance analysis provide an insight into the benefits of the multilayer insulation.

41 EE - Solar Energy Technologies Office (EE-4S)↗