Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Systems Performance Lab”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Advancing Cyber-Attack Detection in Power Systems: A Comparative Study of Machine Learning and Graph Neural Network Approaches

This paper explores the detection and localization of cyber-attacks on power systems, focusing on comparing conventional machine learning (ML) and deep learning methods, and graph neural network (GNN)-based techniques. We assess the detection accuracy of these approaches and their potential to pinpoint the locations of specific buses under attack. Given the demonstrated success of GNNs in other time series anomaly detection applications, we aim to evaluate their performance within the context of power systems cyber-attack. Utilizing the IEEE 68-bus system, we simulated four types of attacks to test the selected approaches. Our results indicate that GNN-based methods outperform conventional machine learning and deep learning models in detection. Additionally, GNNs show promise in accurately localizing attacks for simple scenarios, although they still face challenges in more complex cases.

artificial intelligence↗

Guidance for Grid Resilience Decisions in Rural Minnesota

This report assesses the hazard landscape of the state of Minnesota, identifies weather hazards that are most impactful to the distribution system, includes a statewide assessment of household access to services dependent on reliable power, reviews resilience planning activities of electric utilities in Minnesota, and presents analysis of distribution grid performance in the face of extreme weather events with data from seven electric cooperatives dispersed throughout outstate Minnesota. This information is synthesized to provide considerations for resilience investment prioritization.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Experimental Setup of Apodization Techniques for Beam Diagnostics Performed at ELBE

The ELBE (Electron Linac for beams with high Brilliance and low Emittance) facility in Dresden, Germany is a multipurpose user facility, which is also used for accelerator R&D purposes. The beam line was set up for transverse beam profile measurements, where the imaging system includes a series of three apodizers and five circular apertures. During beam operations both of these were changed remotely through automated LabView routines. The bunch structure and charge were varied to collect a series of images that were acquired automatically, and then stored for later analysis. Over 12,000 images were captured and then analyzed using software written at Jefferson Lab that runs ImageJ as it's main image processing library.

Freeman, B.↗

Meson Spectroscopy at JLab@12 GeV

Meson, being the simplest hadronic bound system, is the ideal "laboratory" to study the interaction between quarks, to understand the role of the gluons inside hadrons and to investigate the origin of color confinement. To perform such studies it is important to measure the meson spectrum, with precise determination of resonance masses and properties, looking for rare qbar q states and for unconventional mesons with exotic quantum numbers (i.e. mesons with quantum numbers that are not compatible with a qbar q structure). With the imminent advent of the 12 GeV upgrade of Jefferson Lab a new generation of meson spectroscopy experiments will start: "Meson-Ex" in Hall B and "GLUEX" in Hall D. Both will use photo-production to explore the spectrum of mesons in the light-quark sector, in the energy range of few GeVs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Commissioning and operational results of the 12 GeV helium compression system at Jlab

The new compressor system at Jefferson Lab (JLab) for the 12 GeV upgrade was commissioned in the spring of 2013 and incorporates many design changes, discussed in previous publications, to improve the operational range, efficiency, reliability and maintainability as compared to previous compressor skids used for this application. The 12 GeV helium compression system has five compressors configured with four pressure levels supporting three pressure levels in the new cold box. During compressor commissioning the compressors were operated independent of the cold box over a wide range of process conditions to verify proper performance including adequate cooling and oil removal. Isothermal and volumetric efficiencies over these process conditions for several built-involume ratios were obtained. This paper will discuss the operational envelope results and the modifications/improvements incorporated into the skids.

Knudsen, Peter N.↗

Post mortem results of laser-optical system packaged for use in harsh environments

In this study, the design and packaging of laser-optical system was tested to harsh environments outside lab conditions and post mortem activities will be discussed. Previously, custom mounts and bonded optical assemblies were environmentally tested to ensure their survivability. The results verified the sub-assemblies would enable the design of a laser-optical initiation system that could be fielded for use in extreme conditions. The design package, which utilized the proven opto-mechanical sub-assemblies, was then tested to the same levels as the sub-assemblies. The test regiment encompassed the harshest environments currently utilized. Temperature tests were performed ranging from a maximum of +75 degrees C to a minimum of -55 degrees C, allowing for two hour soak at each temperature set point. Vibration tests were performed to a maximum level of 15.5 grms for forty seconds in each of three critical axes. Shock tests were performed to a maximum impulse level of 5700 G's for the sub-assemblies with a 1.1 millisecond long pulse; whereas the packaged laser system maximum level reached was 3700 G's at 1.1 millisecond long pulse. The laser-optical assembly was visually inspected and functionally tested before and after each test to verify survival. As designed, the system covers were laser welded shut for hermetic seal. The only open port was the laser output for testing and verification of laser performance. No optical cables were utilized. Therefore the visual inspection of the interior was performed post mortem. Finally, the post mortem results will be discussed as will the potential of redesigns on future packaging strategies.

42 ENGINEERING↗

AI Data Quality Monitoring with Hydra

Hydra is an extensible framework for training and managing AI for near real time monitoring that aims to replace the tedious and repetitive data quality monitoring activities the shift crew and online monitoring coordinator typically perform. It continuously scans incoming data in the form of monitoring plots for signs of problems, flagging them for human review. A web app was developed such that experts can efficiently label images for training. Labels are stored in a database for use in training and model validation. Backed up by a comprehensive database, it utilizes an additional web based front-end for viewing the current monitoring status from anywhere in the world. The system has been in production use for the GlueX experiment at Jefferson Lab for more than 2 years with new features still under active development.

Britton, Thomas↗

Next generation retrofit wall panels with integrated vacuum insulation panels

Approximately two-thirds of residential buildings in the United States were constructed before the Department of Energy established energy conservation measures. These buildings present major opportunities for improving energy efficiency, though retrofitting them remains technically and economically challenging. This study presents the development and the durability evaluation of an innovative retrofit panel system that integrates vacuum insulation panels (VIP) with a nail-base panel (called a retrofit insulated panel) to enhance thermal performance with minimal disruption to occupants and without altering standard nail-based panel installation practices. Hygrothermal simulations were conducted to assess the moisture behavior of wall assemblies before and after retrofit installation under varying water vapor control strategies and climate conditions. Results indicate that, with appropriate moisture control strategy, the retrofit system effectively prevents moisture accumulation, keeping mold index values and relative humidity levels below critical thresholds. Additionally, Guarded Hot Box testing was performed to compute the effective R-value of the panel under different coverage areas that demonstrates its effectiveness in enhancing both thermal and moisture performance in existing residential buildings.

Iffa, Emishaw [ORNL]↗

System Advisor Model (SAM) Improvements for Emerging Solar Thermal Applications

The System Advisor Model (SAM) is an open-source tool developed by NREL to simulate the techno-economic performance of technologies like photovoltaics, solar thermal, wind, and geothermal. NREL has recently completed, active, and planned projects to improve the solar thermal models in SAM and its underlying code base to represent emerging component technologies, systems, and applications. This poster describes new capabilities in the SolarPILOT optical modeling tool, supercritical carbon dioxide (sCO2) power cycles, and solar industrial process heat.

14 SOLAR ENERGY↗

Biomass Research Program

INL's mission is to achieve DOE's vision of supplying high-quality raw biomass; preprocessing biomass into advanced bioenergy feedstocks; and delivering bioenergy commodities to biorefineries. You can learn more about research like this at the lab's facebook site http://www.facebook.com/idahonationallaboratory.

09 BIOMASS FUELS↗

Performance of the Pair Spectrometer in Hall D at Jefferson Lab

This article describes the performance of the pair spectrometer installed in experimental Hall D at Jefferson Lab and its successfully operation in multiple experiments with the GlueX detector. The primary purpose of the pair spectrometer is the precise determination of the flux of beam photons incident on the GlueX target, a critical input for physics analyses such as absolute cross-section measurements. The photon energy spectrum is determined by reconstructing electron–positron pairs produced in a thin converter inserted into the photon beam. The spectrometer is integrated into the GlueX trigger system, whose electronics enable continuous real-time monitoring of the photon flux and the recording of e+e- pair candidates for offline analysis. In addition, the pair spectrometer provides a versatile test facility for evaluating calorimeter prototypes using leptons with well-defined energies produced via electromagnetic pair production.

Somov, Alexander [Jefferson Lab]↗

11.424 Ghz Stripline Transversal Filter for Sub-Picosecond Bunch Timing Measurements

Measurement of time-of-arrival or instantaneous longitudinal position is a fundamental beam diagnostic. We present results from a stripline transversal periodic coupler structure which forms the heart of a sub-ps beam timing detector. This filter structure approximates a sinx/x response in the frequency domain which corresponds to a limited pulse length response in the time domain. These techniques have been used extensively in beam feedback systems at 3 GHz center frequencies with operational single-shot resolutions of 200 fs [1]. We present a new design, based on a 11.424 GHz center frequency, which is intended to offer a factor of four improvement in time resolution. Two-dimensional electromagnetic simulation results are shown, and the design optimization approach leading to the final circuit implementation is illustrated. The prototype circuit has been fabricated on 64mil Rogers 4003 and lab frequency domain and time domain data are compared to the 2-D simulation results. Performance of the prototype circuit is shown with applicability to sub-ps beam measurements in LINAC and FEL applications.

43 PARTICLE ACCELERATORS↗

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION↗

Elastic scattering in the 12 N + 197 Au system at 𝐸 lab = 70 MeV

Halo structure is an interesting exotic configuration developed in some light weakly bound nuclei, where a valence particle orbits a nuclear core. Signatures of halo structure can be observed in the angular distributions of the elastic scattering induced by these nuclei at energies around the Coulomb barrier. There are some well-studied reactions with neutron-rich halo nuclei, such as 6 He and 11 Li . However, the information is scarce on the proton-rich side. Recent works confirm the halo structure in the 8B nuclei but still lack more experimental studies for other proton-halo candidates, such as 12 N and 17 F. In this work, we report experimental data for the elastic scattering of 12 N on 197 Au target at 𝐸 lab = 70 MeV. The 12 N is a proton-rich nucleus with proton separation energy 𝑆 𝑝 = 600 keV, which is higher than the 8 B (𝑆 𝑝 = 137 keV) and almost the same as the 17 F (𝑆 𝑝 = 601 keV). Data were obtained at the Cyclotron Institute of Texas A&M University where the 12 N radioactive beam was produced by the momentum achromatic recoil spectrometer. The calculation of the optical model was used to fit the measured angular distribution for the elastic scattering and to obtain the reaction cross section 𝜎 𝑅 . We also performed continuum discretized coupled-channel calculations to compare with the experimental data. The angular distribution of the elastic cross sections exhibits a suppression of the Fresnel peak. From the fitting of the optical model, we obtain the total reaction cross section, 𝜎 𝑅 = 1269 ± 41 mb. The agreement between the CDCC calculation and the experimental elastic scattering data is limited and the breakdown does not exhaust the measured 𝜎 𝑅 . The resulting reduced reaction cross section 𝜎 Red for 12 N + 197 Au is large and comparable to the one obtained for the 8 B + 208 Pb system. This suggests a strong decoupling of the valence proton from the core because of the low binding energy and a dynamic polarization effect. Here, more research is required to estimate the contribution of core excitation.

Elastic scattering reactions↗

Self-powered Through-wall communication for dry cask storage monitoring

Many nuclear facilities, such as spent fuel storage dry casks and nuclear reactor pressure vessels, are entirely sealed by metal layers to prevent harmful radiation. For safety and security operations, the temperature, pressure, radiation, and humidity inside the vessel needs to be closely monitored. However, no practical technology is currently available to realize the through-wall data communication and monitoring for these vessels due to the inside harsh environment of high temperature and nuclear radiation. In this paper, an innovative self-powered wireless through-wall data communication system for the nuclear environment is presented, which demonstrates a successful solution to such challenges. The presented system is composed of four modules, i.e., energy harvester with power management circuits, ultrasound wireless communication using high-temperature piezoelectric transducers, electronic circuits for sensing and data transmission, and radiation shielding for electronics. Here, constitutive functions of each module were firstly designed and followed by the system integration. Experiments were conducted subsequently to validate the designed functions and evaluate the performance of the integrated system. Results showed that the average power of over 40 mW was harvested from the thermal flow inside the nuclear spent fuel canisters which could provide enough energy to operate the sensing and data communication systems. The gamma radiation test results showed that the thermoelectric energy harvester and ultrasound transceivers can withstand radiation dosing over 100 Mrad. Furthermore, temperature shock tests demonstrated that the entire system including the shielded electronics can survive and maintain their functionalities at temperatures as high as 195°C. Under the in-lab mocked-up high temperature conditions and radiation shielding, the proposed system is foreseen to survive and operate stably for fifty years inside a nuclear spent fuel canister, and send the frequency modulated data out of the canister for 3 s in every 10 min.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment Report 76376 Assess the Quality of Center 00600 Completed Assessments for FY2018

Department 00635, Performance Assurance, assessments reveal risks and opportunities for improvement Labs-wide. This assessment was conducted to identify opportunities for improving the Department 00635 Assessment Program. This evaluation was conducted to identify opportunities for improving the Center 00600 assessment process by reviewing the quality of assessments completed by Environment Safety and Health (ES&H) personnel in fiscal year (FY) 2018. Approximately 20 percent of the Center 00600 assessments completed in FY18 were reviewed. One assessment was selected from each Center 00600 department contingent on availability in the Assurance Information System (AIS).

42 ENGINEERING↗

High Temperature Ceramic Heat Exchangers for the Gen3 Concentrated Solar Power Systems

As part of the Department of Energy’s Solar Energy Technology Office (SETO), the Concentrated Solar Power (CSP) Gen3 Demonstration Roadmap outlined the various technology pathways, goals, and technology needs/gaps to integrate CSP to a supercritical CO 2 (sCO 2 ) power cycle that operates at temperatures >700 °C. It is envisioned that the higher temperature power cycle will enhance the overall system efficiencies and reduce the levelized cost of electricity (LCOE) to meet a 2030 cost target of $0.05/kWhe for baseload CSP plants with ≥12 hours of storage. In this regard, there is a need for heat exchangers (HXs) that can operate at high sCO 2 pressures and temperatures >700 °C. Since current high-temperature alloys degrade at high temperatures, as part of this project, advanced ceramic materials, HX designs, and low-cost additive manufacturing approaches were developed to fabricate and evaluate the performance of the lab-scale ceramic HX prototypes.

14 SOLAR ENERGY↗

From Theory to Practice: Feasibility Study of a Thermal Microgrid at a DoD Installation

Advanced district thermal energy systems, also known as thermal microgrids, can meet the energy needs of urban districts in a highly efficient way, but adoption of such systems, especially in the United States, has been slow. Thermal microgrids use a network circulating water at near-ambient (60-80 degrees F; 15-25 degrees C) temperatures, and water-source heat pumps at connected buildings are used to boost or lower the temperature for space conditioning and service hot water. Addressing challenges related to retrofits of existing buildings for integration with such systems, as well as quantifying the benefits of different configurations, will be key to accelerating their adoption. This paper aims to contribute to that by reporting preliminary results from a feasibility study of a thermal microgrid at a U.S. Department of Defense installation and illustrating the process of conceptual design to seek the best possible performance within the many constraints of existing buildings. The cluster of buildings under consideration in this study has much in common with commercial buildings in the United States. The process of and results from this feasibility study can inform assessment of the potential for thermal microgrids in other locations and help unlock the benefits of such systems for resilience and energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗