Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Switched systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Plasmon mediated coherent population oscillations in molecular aggregates

The strong coherent coupling of quantum emitters to vacuum fluctuations of the light field offers opportunities for manipulating the optical and transport properties of nanomaterials, with potential applications ranging from ultrasensitive all-optical switching to creating polariton condensates. Often, ubiquitous decoherence processes at ambient conditions limit these couplings to such short time scales that the quantum dynamics of the interacting system remains elusive. Prominent examples are strongly coupled exciton-plasmon systems, which, so far, have mostly been investigated by linear optical spectroscopy. Here, we use ultrafast two-dimensional electronic spectroscopy to probe the quantum dynamics of J-aggregate excitons collectively coupled to the spatially structured plasmonic fields of a gold nanoslit array. We observe rich coherent Rabi oscillation dynamics reflecting a plasmon-driven coherent exciton population transfer over mesoscopic distances at room temperature. This opens up new opportunities to manipulate the coherent transport of matter excitations by coupling to vacuum fields.

74 ATOMIC AND MOLECULAR PHYSICS↗

KOH vs Deionized Water Operation in Anion Exchange Membrane Electrolyzers

Anion exchange membrane water electrolyzers (AEMELs) have recently received significant attention due to their potential advantages over proton exchange membrane electrolyzers (PEMELs). However, some AEMELs feed an aqueous salt solution to the cell where PEMELs typically feed deionized (DI) water. DI water is preferred to keep the system and maintenance costs low. Because of this, many AEMEL researchers report performance both in the salt solution (typically KOH) and DI water. However, the methodology for switching between KOH and DI water is often poorly defined, and it is unclear what impact the residual salt has on cell performance after switching from salt to DI water. Having a fully deionized environment is important because the presence of salts in the water feed increase the effective electrochemical surface area of the catalyst in the three-dimensional electrode and residual salt remaining after switching to DI water feed can have a misleading transient effect on cell performance. This paper focuses on understanding the transition from KOH to DI water testing in AEMELs. It is shown that when switching from salt to DI water feed, a large volume of DI water must be fed over several hours to achieve true DI-water performance. It is also shown that starting AEMELs from the beginning with DI water feed (without any KOH ever being fed to the cell) results in better cell durability. Lastly, a cell is demonstrated having operated exclusively on DI water at 1.0 A cm −2 for 500 h at an operating voltage of ca. 2 V and a low degradation rate.

08 HYDROGEN↗

Machine-learning-aided cognitive reconfiguration for flexible-bandwidth HPC and data center networks [Invited]

This paper proposes a machine-learning (ML)-aided cognitive approach for effective bandwidth reconfiguration in optically interconnected datacenter/high-performance computing (HPC) systems. The proposed approach relies on a Hyper-X-like architecture augmented with flexible-bandwidth photonic interconnections at large scales using a hierarchical intra/inter-POD photonic switching layout. We first formulate the problem of the connectivity graph and routing scheme optimization as a mixed-integer linear programming model. A two-phase heuristic algorithm and a joint optimization approach are devised to solve the problem with low time complexity. Then, we propose an ML-based end-to-end performance estimator design to assist the network control plane with intelligent decision making for bandwidth reconfiguration. Numerical simulations using traffic distribution profiles extracted from HPC applications traces as well as random traffic matrices verify the accuracy performance of the ML design estimator ( < <#comment/> 9 % <#comment/> error) and demonstrate up to 5 × <#comment/> throughput gain from the proposed approach compared with the baseline Hyper-X network using fixed all-to-all intra/inter-portable data center interconnects.

Chen, Xiaoliang (ORCID:0000000278056237)↗

Olympus System Backplane Definition

The purpose of this document is to define the backplane of the Olympus firing system, a modular system based on SpaceWire communication between modules. The backplane provides the connection between the modules, controller (embedded in the front module), the SpaceWire router, and an alternative switch. Those connections include SpaceWire links, interlocks, a key, a dead-man switch (DMS)/charge, timing lines, power distribution, geographical addresses, and communication to the human-machine interface (HMI). This backplane is based on the VMEBus International Trade Association (VITA) 46 Specification (VPX) and OpenVPX standards for a 3U backplane. Unless otherwise specified, those standards apply for signal definitions and mechanical specifications.

42 ENGINEERING↗

Solar-battery integrated DC system

A DC bus is connected to a PV array, a battery or both, to power a grid connected inverter load on the bus. A system and method is described for controlling current flow on a DC bus regardless of the type of inverter. A converter receives a DC battery voltage. A switching module controls current flow through the converter. A current generator generates a reference current in response to a reference voltage. A comparator connected at the output of the current generator compares the reference current with a battery current and outputs a signal to a controller. The controller generates a reference value. A PWM generator modulates the switch module to control current flow and energy flow between the DC bus and the battery. The current from the DC bus to the inverter is controlled to allow proper grid-connected operation regardless of inverter type.

Atcitty, Stanley↗

A Review on Protection Challenges on Transmission Lines Connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses. Utilities, university researchers, research institutes, and relay manufacturers have performed studies to investigate different aspects of high IBR penetration. Almost all studies support 1) creating international and national standards to regulate the IBRs, 2) revising engineering tools to address shortcomings, and 3) adjusting the protective relay settings to resolve protection problems. This paper summarizes the studies and research conducted in recent years to quantify the impact of IBR penetration on transmission line protection and to identify potential solutions to improve the dependability and reliability of grid protection systems.

14 SOLAR ENERGY↗

A review on protection challenges of Transmission Lines connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses.

14 SOLAR ENERGY↗

A Review on Protection Challenges of Transmission Lines Connected to Inverter-Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses

14 SOLAR ENERGY↗

Spin-orbit–driven ferromagnetism at half moiré filling in magic-angle twisted bilayer graphene

Strong electron correlation and spin-orbit coupling (SOC) can have a profound influence on the electronic properties of materials. We examined their combined influence on a two-dimensional electronic system at the atomic interface between magic-angle twisted bilayer graphene and a tungsten diselenide crystal. We found that strong electron correlation within the moiré flatband stabilizes correlated insulating states at both quarter and half filling, and that SOC transforms these Mott-like insulators into ferromagnets, as evidenced by a robust anomalous Hall effect with hysteretic switching behavior. The coupling between spin and valley degrees of freedom could be demonstrated through control of the magnetic order with an in-plane magnetic field or a perpendicular electric field. Our findings establish an experimental knob to engineer topological properties of moiré bands in twisted bilayer graphene and related systems.

36 MATERIALS SCIENCE↗

Grid Optimization Competition on Synthetic and Industrial Power Systems

This paper summarizes a grid optimization (GO) competition effort in the United States to find the best solution strategies for up to interconnect-scale power system networks with around 32,000 buses. The optimization problem is a mixedinteger, non-convex non-linear problem, (MINLP) and includes discrete variables such as unit commitment and line switching, control settings (transformer taps and phase shifters with impedance correction tables), and bus shunts. The case study includes six actual industry grids as well as 16 realistic synthetic grids created by three different dataset teams. The winners are selected and ranked based on scoring criteria, which consider the solution quality (such as objective functions) within time limits. Nine winner teams are selected from 26 competitor teams. The results achieved by different teams are described and the performance of different algorithms on synthetic grids and actual industry grids are compared and analyzed.

mixed-integer non-linear programming↗

eCounter: Inline Per-IP Network Monitoring at Millisecond Resolution via eBPF

Scientific data acquisition (SciDAQ) systems are shifting from archive-based workflows to streaming paradigms, where real-time, fine-grained network monitoring becomes essential. While P4-enabled devices offer per-packet in-band observability, they require specialized switches and routers. Host-side tools like Prometheus exporters lack sufficient temporal granularity. To bridge this gap, we present eCounter, a lightweight, hardware-agnostic, inline telemetry agent built on extended Berkeley Packet Filter (eBPF). eCounter captures per-interface ingress and egress traffic, categorized by IP address and protocol, at millisecond to sub-millisecond resolution. In a 100 Gbps environment, it continuously exports up to 3,257 time-series bins per second with only 4% CPU utilization at a 35¿KiB/s data rate. We evaluate eCounter across diverse NIC MTU settings, hook types, CPU architectures and operating systems, and observed negligible impact on concurrent high-throughput streaming applications. Complexity analysis confirms that it can be readily scaled to distributed SciDAQ deployments.

Mei, Xinxin [Computational Sciences and Technology↗

Structural origin of size effect on piezoelectric performance of Pb(Zr,Ti)O 3

Grain size effect plays a vital role in piezoelectric performance from both scientific and technological view. However, the underlying structural mechanism related to grain size is still unclear. In the present study, the structural mechanism of grain size effect on piezoelectric performance has been revealed in the prototype Pb(Zr, Ti)O 3 system by using in-situ synchrotron X-ray diffraction. The miniaturization of grain size tends to favor the appearance of higher symmetric tetragonal phase, while a single monoclinic phase is determined in the coarse-grained ceramics. The direct structural evidence reveals that both tetragonal and monoclinic phases in the fine-grained ceramics are less sensitive to the electric field, corresponding to the inferior piezoelectric performance, while the single monoclinic phase in the coarse-grained ceramics is more active to be driven by the electric field, generating good piezoelectric behavior. Both domain switching ability and lattice strain are suppressed with decreasing grain size, which directly leads to the deterioration in piezoelectric performance. In conclusion, the current results will benefit the structural understanding of the size effect of piezoelectric and other related systems.

36 MATERIALS SCIENCE↗

Generation of out-of-plane ferroelectric behavior in a one-atom-thick monolayer

Ferroelectricity with out-of-plane polarization has so far been found in several two-dimensional (2D) materials, including monolayers comprising three to five planes of atoms, e.g. α-In 2 Se 3 and MoTe 2 . Here, we explore the generation of out-of-plane polarization within a one-atom-thick monolayer material, namely hexagonal boron nitride. We performed density-functional-theory calculations to explore inducing ferroelectric-like distortions through incorporation of isovalent substitutional impurities that are larger than the host atoms. This disparity in bond lengths causes a buckling of the h-BN, either up or down, which amounts to a dipole with two equivalent energies and opposing orientations. We tested several impurities to explore the magnitude of the induced dipole and the switching energy barrier for dipole inversion. The effects of strain, dipole–dipole interactions, and vertical heterostructures with graphene are further explored. Our results suggest a highly-tunable system with ground state antiferroelectricity and metastable ferroelectricity. Finally, we expect that this work will help foster new ways to include functionality in layered 2D-material-based applications.

36 MATERIALS SCIENCE↗

Pulse charging system

A system, method, and apparatus for pulsed charging applications comprises a bulk capacitor operably connected to a power source, an inductor connected to the bulk capacitor with a charge switch, a pulse capacitor connected to the inductor, a freewheeling diode connecting a point between the charge switch and the inductor to a point after the pulse capacitor, a second diode connecting the inductor to the pulse capacitor, and a pulse switch connecting the pulse capacitor to a load.

42 ENGINEERING↗

All‐Liquid Reconfigurable Electronics Using Jammed MXene Interfaces

Abstract Rigid, solid‐state components represent the current paradigm for electronic systems, but they lack post‐production reconfigurability and pose ever‐increasing challenges to efficient end‐of‐life recycling. Liquid electronics may overcome these limitations by offering flexible in‐the‐field redesign and separation at end‐of‐life via simple liquid phase chemistries. Up to now, preliminary work on liquid electronics has focused on liquid metal components, but these devices still require an encapsulating polymer and typically use alloys of rare elements like indium. Here, using the self‐assembly of jammed 2D titanium carbide (Ti 3 C 2 T x ) MXene nanoparticles at liquid–liquid interfaces, “all‐liquid” electrically conductive sheets, wires, and simple functional devices are described including electromechanical switches and photodetectors. These assemblies combine the high conductivity of MXene nanosheets with the controllable form and reconfigurability of structured liquids. Such configurations can have applications not only in electronics, but also in catalysis and microfluidics, especially in systems where the product and substrate have affinity for solvents of differing polarity.

36 MATERIALS SCIENCE↗

Inverter Intensive Hybrid Power Plant Modeling with Small-Signal Stability Augmentation through Flexible Operation Mode Transition

Hybrid power plants (HPPs) prompt the penetration of inverter-based renewable energy sources (RES) in transmission systems; however, given their low-inertia nature, HPPs are dominated by power electronic inverters, so there are inevitable challenges in system stability when increasing numbers of HPPs are integrated into the modern power grids. To boost the penetration level of HPPs without jeopardizing system stability, it is desirable to equip them with operational characteristics (i.e., grid-forming capabilities) that are comparable to those of conventional power plants dominated by synchronous generators (SGs). In this paper, a holistic model of inverter intensive HPP is derived and a bi-level hierarchical control is developed to allow HPPs to flexibly switch among the designed operation modes (i.e., P-Q, P-V, and isochronous modes). Compared to SGs, which have limited controllability, the operation mode of each HPP could vary as requested. Such flexible mode transitions could be integrated into the secondary plant-level control and be leveraged as an additional control degree to further augment system stability. Further, the system small-signal stability margin is quantified with varying HPP operation modes. More importantly, modal analysis is thereby conducted to quantify the impacts of mode transition on the system oscillatory modes. The effectiveness of the proposed HPP bi-level hierarchical control is verified using extensive case studies based on the simplified real-world island power grid, and the results validate that the system small-signal stability margin can be enhanced with the additional degree of control flexibility enabled by HPP operation mode transition. The real-time hardware-in-the-loop (HIL) results are also provided to verify the proposed method.

grid-forming control↗

Demand response of loads having thermal reserves

Systems and methods are described herein that improve grid performance by smoothing demand using thermal reserves. The smoothed demand can reduce peak loads as well as the ramp rate of demand that will otherwise require the use of inefficient, expensive generation sources. These improvements are tied to the selective switching on or off electrical loads that are coupled to thermal reserves, effectively using the thermal reserves as an energy storage mechanism. Historical data of past usage can be used to create load model and ensure that effects on customer comfort are minimized while still accomplishing the beneficial effects for the overall grid, which enables grid owners to both reduce their operational cost by avoiding expensive generation and improve system reliability by achieving more predictable power demand.

Ren, Wei↗

Swinging Hydrogen Evolution to Nitrate Reduction Activity in Molybdenum Carbide by Ruthenium Doping

A common challenge for electrochemical ammonia synthesis in an aqueous phase is the consumption of Faradaic charge by the competing hydrogen evolution reaction (HER), which reduces the Faradaic efficiency for the desired conversion, i.e., the nitrate reduction reaction (NO 3 RR) to ammonium. This problem is particularly severe when a single-phase catalyst is operated at high current limits, thus a cocatalyst system that works synergistically for hydrogen acquisition and deoxygenation is needed to promote NO 3 RR over HER. For this study, we select a well-known HER catalyst Mo 2 C and investigate how metal doping can switch its kinetics from HER-dominated to NO 3 RR-dominated pathways. At 3.8 wt % Ru doping of Mo 2 C, a 75% single pass conversion of nitrate (0.1 M) to ammonium in a 16 cm 2 flow electrolyzer was achieved, corresponding to an ammonium yield rate of 9.07 mmol h –1 at a full cell voltage of 2 V. As confirmed by DFT calculations and kinetic isotope experiments, ruthenium dopants in the matrix serve as the sink point for adsorbed hydrogen during NO 3 RR to promote the cooperative deoxygenation of *NO 3 and *NO 2 on the Ru–Mo cocatalytic site. Our study suggests that optimizing hydrogen acquisition and deoxygenation reactions in cocatalytic systems is an effective strategy for electrochemical synthesis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗