To secure competitive financing for a solar energy generation project, the economic risk associated with interannual solar resource variability must be quantified. One way to quantify this risk is to calculate exceedance probabilities representing the amount of energy expected to be produced by a plant. Many years of solar radiation and metereological data are required to determine these values,often called P50 or P90 values for the level of certainty they represent. This paper describes the two methods implemented in the National Renewable Energy Laboratory's System Advisor Model (SAM) to calculate P50 and P90 exceedance probabilities for solar energy projects. The methodology and supporting data sets are applicable to photovoltaic, solar water heating, and concentrating solar power(CSP) systems.
A power plant includes a solar receiver heating solid particles, a standpipe receiving solid particles from the solar receiver, a pressurized heat exchanger heating working fluid by heat transfer through direct contact with heated solid particles flowing out of the bottom of the standpipe, and a flow path for solid particles from the bottom of the standpipe into the pressurized heat exchanger that is sealed by a pressure P produced at the bottom of the standpipe by a column of heated solid particles of height H. The flow path may include a silo or surge tank comprising a pressure vessel connected to the bottom of the standpipe, and a non-mechanical valve. The power plant may further include a turbine driven by heated working fluid discharged from the pressurized heat exchanger, and a compressor driven by the turbine.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
One strategy for helping the solar industry to grow faster is to use very high efficiency cells under concentrating optics. By using lenses or mirrors to concentrate the light, very small solar cells can be used, reducing the amount of semiconductor material and allowing use of higher efficiency cells, which are now >40% efficient.
Residential electric vehicle (EV) chargers, as single phase loads, contribute to unbalanced voltage drops across phases, while rooftop solar systems, as single phase generators, can exacerbate voltage imbalance by causing unbalanced voltage increases. This paper investigates combined effects of residential EV charging and rooftop solar generation on voltage imbalance in residential distribution grids. The study examines these simultaneous impacts using the IEEE 8500-node test system, enhanced with a secondary network to realistically model the EV chargers and rooftop solar integration. To account for the variability and uncertainty in the EV charging loads and solar generation, a Monte Carlo approach is employed to capture and quantify the simultaneous impact of the EV charging and rooftop solar integration. In this approach, multiple influencing factors are considered, including state-of-charge (SOC), maximum charging power levels, and geographic distribution of chargers. The results provide practical insights for utilities and stakeholders, offering expectations for planning and operating strategies that effectively manage the increasing adoption of EVs and solar power while maintaining grid reliability.
In designing generating solar-engineering devices, the first priority is the predesign study of the potential of local resources of solar energy at the places where they may be located. Currently, actinometric information is obtained in several ways. They include direct measurement of solar-radiation characteristics at meteorological stations or from satellites and analytical methods for calculating intensity of solar radiation. Despite the significant number of sources of actinometric information, it seems impossible to evaluate the potential of incoming solar energy in the region, to substantiate the composition and parameters of solar-power-plant equipment, and to predict its operation at the initial stage. Using the example of the town of Kamyshin in Volgograd oblast, the sufficiency of required actinometric information is analyzed for further solar-engineering calculations and the data accuracy and limits of their applicability are estimated.
With an increasing penetration level of solar power in the southern Nevada system, the impact of solar on system operations needs to be carefully studied from various perspectives. Qualitatively, it is expected that the balancing requirements to compensate for solar power variability will be larger in magnitude; meanwhile, generators providing load following and regulation services will be moved up or down more frequently. One of the most important tasks is to quantitatively evaluate the cycling and movements of conventional generators with solar power at different penetration levels. This study is focused on developing effective methodologies for this goal and providing a basis for evaluating the wear and tear of the conventional generators
Final report for Folsom Labs’ Solar Permit Generator project, which has successfully completed, resulting in the development and commercialization of a software toolkit within the cloud-based HelioScope software environment that enables solar engineers to automatically generate and manage draft documents for permit submission.
Nuclear power plants operate most efficiently and economically when they are operating at some constant power output. However, with the current dynamics of the grid, including the introduction and growth of renewable energy sources such as wind and solar, nuclear generation facilities across the U.S. are finding it difficult to keep their power supply constant and provide for baseload generation capacities. As a result, most nuclear plants are finding it hard to compete with other generation fuel sources, most notably, natural gas. Finding a solution to this intermittent power supply dynamic could help U.S. nuclear power plants economically compete with other generation fuel sources such as natural gas, wind, and solar. The Thermal Energy Delivery System (TEDS) at the INL aims to investigate alternative solutions to this dilemma. The TEDS design focuses on the delivery of thermal energy to different systems throughout the Dynamic Energy Transport and Integration laboratory (DETAIL). Its strategy revolves around allowing the system to operate at full generation output while storing any surplus energy for later use and/or additional function.
For solar electricity generating technologies to be cost competitive at a large scale with conventionally generated electricity, cost reductions are needed for both concentrating solar power (CSP) and solar photovoltaic (PV) systems. In 2011, the U.S. Department of Energy (DOE) established solar cost targets that corresponded to reducing CSP and PV prices by approximately 75% in order to achieve a levelized cost of electricity (LCOE) of $0.06 per kilowatt-hour (kWh) for both utility-scale PV and high-capacity factor CSP-TES systems in 2020. Utility-scale PV achieved its 2020 cost target in 2017, and recent estimates for the LCOE of CSP-TES with a molten-salt power tower system are approximately $0.10/kWh for projects that are expected to come online in 2020, which represents a substantial reduction since 2010 - when the LCOE for CSP-TES was around $0.21/kWh. To continue the momentum for cost reductions in solar technologies, DOE recently established cost targets for 2030 that would make solar one of the lowest-cost sources of new electricity in the United States. For CSP-based systems, the new targets correspond to an LCOE in 2030 of $0.05/kWh for a dispatchable, high-capacity factor CSP-TES plant configuration. This aggressive target would have been unimaginable a decade ago. However, building on the previously described reduction in CSP-TES costs over the past decade, recent announcements suggest the next phase of projects will continue this downward trend through lower installation costs, attractive financing, longer-duration PPAs, and the ability to capitalize on the value that the flexibility of storage brings CSP. This presentation summarizes a recent report that evaluates the potential impacts of simultaneously achieving the 2030 cost targets for PV and CSP-TES, and it includes a detailed evaluation of the role that CSP-TES could play in realizing those impacts. The scenarios in this analysis are designed to isolate and assess the potential impacts of achieving DOE's 2030 cost targets for CSP-TES and PV, and they do not reflect the potential benefits or system impacts associated with success in other DOE research programs. The low-cost solar scenarios include DOE's 2030 solar cost targets--which are represented via a roughly 50% reduction in LCOE by 2030 (from current levels) with additional cost reductions thereafter representing technology learning and/or improvements that could result from innovation - coupled with a variety of market, technology, and demand assumptions. With these assumptions, the evolution of the contiguous U.S. electricity system is evaluated with NREL's Renewable Energy Deployment System (ReEDS) model, which was specifically designed to represent the temporal and locational value of renewable generation technologies in the U.S. power system. ReEDS relies on system-wide least-cost optimization to estimate the type and location of future generation and transmission capacity. In addition, it accounts for the locational and temporal variations in variable renewable technologies, including the need for new transmission, curtailment, dynamic capacity value, and the need to hold operating reserves to account for the uncertainty and variability of these technologies. This presentation summarizes the key findings that arise from a detailed evaluation of the impacts of achieving DOE's 2030 cost targets for CSP-TES and PV systems, noting again the inherent challenges associated with modeling future scenarios of the large, complex system electricity system in the contiguous United States within the context of various market features.
Our oceans are vast, mostly unexplored and difficult to monitor. Large-scale implementation of a fully autonomous 'Internet of Underwater Things' would transform how we collect and share data from this domain; however, deployment is prohibited by the lack of persistent power sources. In principle, underwater solar-energy generation can complement the use of batteries and provide a solution, although dedicated research is needed since traditional silicon solar cells do not perform well underwater due to water's strong absorption of near-infrared light. In this Perspective we present examples of solar-powered underwater applications and discuss which types of solar-harvesting materials could be appropriate, including GaInP variants, CdTe, organic semiconductors, and perovskite semiconductors. We also discuss challenges that need to be addressed, such as the development of effective antifouling coatings and new certification standards given that underwater conditions are starkly different from those in terrestrial environments.
At present, the Babcock–Leighton flux transport solar dynamo models appear to be the most promising models for explaining diverse observational aspects of the sunspot cycle. The success of these flux transport dynamo models is largely dependent upon a single-cell meridional circulation with a deep equatorward component at the base of the Sun’s convection zone. However, recent observations suggest that the meridional flow may in fact be very shallow (confined to the top 10% of the Sun) and more complex than previously thought. Taken together, these observations raise serious concerns on the validity of the flux transport paradigm. By accounting for the turbulent pumping of magnetic flux, as evidenced in magnetohydrodynamic simulations of solar convection, we demonstrate that flux transport dynamo models can generate solar-like magnetic cycles even if the meridional flow is shallow. Solar-like periodic reversals are recovered even when meridional circulation is altogether absent. However, in this case, the solar surface magnetic field dynamics does not extend all the way to the polar regions. Very importantly, our results demonstrate that the Parker–Yoshimura sign rule for dynamo wave propagation can be circumvented in Babcock–Leighton dynamo models by the latitudinal component of turbulent pumping, which can generate equatorward propagating sunspot belts in the absence of a deep, equatorward meridional flow. We also show that variations in turbulent pumping coefficients can modulate the solar cycle amplitude and periodicity. Our results suggest the viability of an alternate magnetic flux transport paradigm—mediated via turbulent pumping—for sustaining solar-stellar dynamo action.
The long-term stability in acidic or alkaline aqueous electrolytes of p-Ga 0.52 In 0.48 P photocathodes, with a band gap of ~1.8 eV, for the solar-driven hydrogen-evolution reaction (HER) has been evaluated from a thermodynamic, kinetic, and mechanistic perspective. At either pH 0 or pH 14, etched p-GaInP electrodes corroded cathodically under illumination and formed metallic In 0 on the photoelectrode surface. In contrast, under the same conditions, electrodeposition of Pt facilitated the HER kinetics and stabilized p-GaInP/Pt photoelectrodes against such cathodic decomposition. When held at 0 V versus the reversible hydrogen electrode, p-GaInP/Pt electrodes in either pH = 0 or pH = 14 exhibited stable current densities (J) of ~-9 mA cm -2 for hundreds of hours under simulated 1 sun illumination. During the stability tests, the current density-potential (J-E) characteristics of the p-GaInP/Pt photoelectrodes degraded due to pH-dependent changes in the surface chemistry of the photocathode. This work provides a fundamental understanding of the stability and corrosion mechanisms of p-GaInP photocathodes that constitute a promising top light absorber for tandem solar-fuel generators.