Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Simulation methods.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

SU-F-J-123: CT-Based Determination of DIBH Variability and Its Dosimetric Impact On Post-Mastectomy Plus Regional Nodal Radiation Therapy

Purpose: Breast cancer radiotherapy delivered using voluntary deep inspiration breath-hold (DIBH) requires reproducible breath holds, particularly when matching supraclavicular fields to tangential fields. We studied the impact of variation in DIBHs on CTV and OAR dose metrics by comparing the dose distribution computed on two DIBH CT scans taken at the time of simulation. Methods: Ten patients receiving 50Gy in 25 fractions to the left chestwall and regional lymph nodes were studied. Two simulation CT scans were taken during separate DIBHs along with a free-breathing (FB) scan. The treatment was planned using one DIBH CT. The dose was recomputed on the other two scans using adaptive planning (Pinnacle 9.10) in which the scans are registered using a cross-correlation algorithm. The chestwall, lymph nodes and OARs were contoured on the scans following the RTOG consensus guidelines. The overall translational and rotational variation between the DIBH scans was used to estimate positional variation between breath-holds. Dose metrics between plans were compared using paired t-tests (p < 0.05) and means and standard deviations were reported. Results: The registration parameters were sub-millimeter and sub-degree. Although DIBH significantly reduced mean heart dose by 2.4Gy compared to FB (p < 0.01), no significant changes in dose were observed for targets or OARs between the two DIBH scans. Nodal coverage as assessed by V90% was 90%±8% and 89%±8% for supraclavicular and 99%±2% and 97%±22% for IM nodes. Though a significant decrease (10.5%±12.4%) in lung volume in the second DIBH CT was observed, the lung V20Gy was unchanged (14±2% and 14±3%) between the two DIBH scans. Conclusion: While the lung volume often varied between DIBHs, the CTV and OAR dose metrics were largely unchanged. This indicates that manual DIBH has the potential to provide consistent dose delivery to the chestwall and regional nodes targets when using matched fields.

60 APPLIED LIFE SCIENCES↗

A high-order, localized-artificial-diffusivity method for Eulerian simulation of multi-material elastic-plastic deformation with strain hardening

A high-order method for Eulerian simulation of material undergoing large elastic–plastic deformation is developed. Thermodynamically consistent hyperelastic constitutive relations are assumed, facilitating the treatment of solids, liquids, and gases in a unified manner. Here, the method enables the simulation of multi-material interactions using a diffuse interface approach. Numerical capturing of material interfaces, shock waves, contact surfaces, and elastic-plastic strain discontinuities using high-order compact-difference schemes is assisted by Localized Artificial Diffusivity (LAD). In the new setting involving elastic–plastic deformation, the previously established terms for the artificial properties are verified to effectively regularize normal shocks. Additional LAD terms are introduced to the elastic and plastic kinematic equations to regularize shear shocks and other strain discontinuities, improving solution stability. Other important features of the method that improve robustness include the numerical treatment of compatibility terms in the kinematic equations, and the treatment of rotation. Particular emphasis is focused toward new advancements of the methods for plastic-deformation integration and the associated strain hardening of the material, including rate-dependent plasticity. The method is demonstrated on a variety of test problems, including 1-D impacts, a variant of the Shu-Osher problem, a Taylor impact, and a Richtmyer-Meshkov instability between two elastic–plastic solids with strain hardening.

42 ENGINEERING↗

Spin dynamics simulation of electron spin relaxation in Ni{sup 2+}(aq)

The ability to quantitatively predict and analyze the rate of electron spin relaxation of open-shell systems is important for electron paramagnetic resonance and paramagnetic nuclear magnetic resonance spectroscopies. We present a combined molecular dynamics (MD), quantum chemistry (QC), and spin dynamics simulation method for calculating such spin relaxation rates. The method is based on the sampling of a MD trajectory by QC calculations, to produce instantaneous parameters of the spin Hamiltonian used, in turn, to numerically solve the Liouville-von Neumann equation for the time evolution of the spin density matrix. We demonstrate the approach by simulating the relaxation of electron spin in an aqueous solution of Ni{sup 2+} ion. The spin-lattice (T{sub 1}) and spin-spin (T{sub 2}) relaxation rates are extracted directly from the simulations of the time dependence of the longitudinal and transverse magnetization, respectively. Good agreement with the available, indirectly obtained experimental data is obtained by our method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-G-201-13: Investigation of Dose Variation Induced by HDR Ir-192 Source Global Shift Within the Varian Ring Applicator Using Monte Carlo Methods

Purpose: The Varian tandem and ring applicators are used to deliver HDR Ir-192 brachytherapy for cervical cancer. The source path within the ring is hard to predict due to the larger interior ring lumen. Some studies showed the source could be several millimeters different from planned positions, while other studies demonstrated minimal dosimetric impact. A global shift can be applied to limit the effect of positioning offsets. The purpose of this study was to assess the necessities of implementing a global source shift using Monte Carlo (MC) simulations. Methods: The MCNP5 radiation transport code was used for all MC simulations. To accommodate TG-186 guidelines and eliminate inter-source attenuation, a BrachyVision plan with 10 dwell positions (0.5cm step sizes) was simulated as the summation of 10 individual sources with equal dwell times for simplification. To simplify the study, the tandem was also excluded from the MC model. Global shifts of ±0.1, ±0.3, ±0.5 cm were then simulated as distal and proximal from the reference positions. Dose was scored in water for all MC simulations and was normalized to 100% at the normalization point 0.5 cm from the cap in the ring plane. For dose comparison, Point A was 2 cm caudal from the buildup cap and 2 cm lateral on either side of the ring axis. With seventy simulations, 108 photon histories gave a statistical uncertainties (k=1) <2% for (0.1 cm)3 voxels. Results: Compared to no global shift, average Point A doses were 0.0%, 0.4%, and 2.2% higher for distal global shifts, and 0.4%, 2.8%, and 5.1% higher for proximal global shifts, respectively. The MC Point A doses differed by < 1% when compared to BrachyVision. Conclusion: Dose variations were not substantial for ±0.3 cm global shifts, which is common in clinical practice.

60 APPLIED LIFE SCIENCES↗

Spatiotemporal pattern detection, generation, and computation with circuits

Abstract Implementations of neurons, delays, and synapse circuits are presented with simulations. These neural elements are used to create two small spiking neural networks, the Rate-Window and Order-Biased clusters, which are capable of detecting simple two-spike spatiotemporal patterns. A simple pattern detecting network (SPDN) is created by combining the Rate-Window and Order-Biased clusters, where clusters are small spiking neural networks, and its simple pattern detection ability is demonstrated in simulation. The SPDN is used to implement a complex pattern detecting network (CPDN) and its complex pattern detection ability is demonstrated in simulation. Methods for generating arbitrary spatiotemporal patterns are presented. The CPDN and spatiotemporal pattern generation methods are then used to implement a novel spatiotemporal computing paradigm based on detecting and responding to spatiotemporal symbols. A simulation of a spatiotemporal half adder is presented to demonstrate the computing paradigm.

97 - MATHEMATICS AND COMPUTING↗

Modeling of Hydrogen Line Shapes for the Diagnostic of ITER

The state of art of the line shape modeling techniques involved in tokamak edge plasma spectroscopy is reported, in the context of the preparation for ITER. Hydrogen spectra are calculated assuming a line-of-sight crossing a 2D-plasma background obtained from numerical simulations. The Doppler, Zeeman and Stark effects are retained. Ion dynamics effects are accounted for by using the numerical simulation method. The possibility for a line shape-based diagnostic of the ITER divertor plasma is examined through fittings of simulated spectra and comparison with the input plasma fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Performance First-Principles Molecular Dynamics for Predictive Theory and Modeling

This project focused on developing high-performance software tools for First-Principles Molecular Dynamics (FPMD) simulations, and applying them in investigations of materials relevant to energy conversion processes. FPMD is an atomistic simulation method that combines a quantum-mechanical description of electronic structure with the statistical description provided by molecular dynamics (MD) simulations. This reliance on fundamental principles allows FPMD simulations to provide a consistent description of structural, dynamical and electronic properties of a material. This is particularly useful in systems for which reliable empirical models are lacking. FPMD simulations are increasingly used as a predictive tool for applications such as batteries, solar energy conversion, light-emitting devices, electro-chemical energy conversion devices and other materials. During the course of the project, several new features were developed and added to the open-source Qbox FPMD code. The code was further optimized for scalable operation of large-scale, Leadership-Class DOE computers. When combined with Many-Body Perturbation Theory (MBPT) calculations, this infrastructure was used to investigate structural and electronic properties of liquid water, ice, aqueous solutions, nanoparticles and solid-liquid interfaces. Computing both ionic trajectories and electronic structure in a consistent manner enabled the simulation of several spectroscopic properties, such as Raman spectra, infrared spectra, and sum-frequency generation spectra. The accuracy of the approximations used allowed for direct comparisons of results with experimental data such as optical spectra, X-ray and neutron diffraction spectra. The software infrastructure developed in this project, as applied to various investigations of solids, liquids and interfaces, demonstrates that FPMD simulations can provide a detailed, atomic-scale picture of structural, vibrational and electronic properties of complex systems relevant to energy conversion devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-F-T-656: Monte Carlo Study On Air Activation Around a Medical Electron Linac

Purpose: In high energy photon therapy, several radiation protection issues result from photonuclear reactions. The activation of air - directly by photonuclear reactions as well as indirectly by capture of photoneutrons generated inside the linac head - is a major point of concern for the medical staff. The purpose of this study was to estimate the annual effective dose to medical workers due to activated air around a medical high energy electron linac by means of Monte Carlo simulations. Methods: The treatment head of a Varian Clinac in 18 MV-X mode as well as the surrounding concrete bunker were modeled and the radiation transport was simulated using the Monte Carlo code FLUKA, starting from the primary electron striking the bremsstrahlung target. The activation yields in air from photo-disintegration of O-16 and N-14 nuclei as well as from neutron capture on Ar-40 nuclei were obtained from the simulations. The activation build-up, radioactive decay and air ventilation were studied using a mathematical model. The annual effective dose to workers was estimated by using published isotope specific conversion factors. Results: The oxygen and nitrogen activation yields were in contrast to the argon activation yield found to be field size dependent. The impact of the treatment room ventilation on the different air activation products was investigated and quantified. An estimate with very conservative assumptions gave an annual effective dose to workers of < 1 mSv/a. Conclusion: From the results of this study it can be concluded that the contribution of air activation to the radiation exposure to medical workers should be negligible in modern photon therapy, especially when it is compared to the dose due to prompt neutrons and the activation of heavy solid materials such as the jaws and the collimators inside the linac head.

60 APPLIED LIFE SCIENCES↗

Transmission and Propagation of an Accelerating Mode in a Photonic Bandgap Fiber

A hollow core photonic bandgap (PBG) lattice in a dielectric fiber can provide high gradient acceleration in the optical regime, where the accelerating mode resulting from a defect in the PBG fiber can be excited by high-power lasers. Efficient methods of coupling laser power into the PBG fiber are an area of active research. In this paper, we develop a simulation method using the parallel finite-element electromagnetic suite ACE3P to study the propagation of the accelerating mode in the PBG fiber and determine the radiation pattern into free space at the end of the PBG fiber. The far-field radiation will be calculated and the mechanism of coupling power from an experimental laser setup will be discussed.

36 MATERIALS SCIENCE↗

Brownian aggregation rate of colloid particles with several active sites

We theoretically analyze the aggregation kinetics of colloid particles with several active sites. Such particles (so-called “patchy particles”) are well known as chemically anisotropic reactants, but the corresponding rate constant of their aggregation has not yet been established in a convenient analytical form. Using kinematic approximation for the diffusion problem, we derived an analytical formula for the diffusion-controlled reaction rate constant between two colloid particles (or clusters) with several small active sites under the following assumptions: the relative translational motion is Brownian diffusion, and the isotropic stochastic reorientation of each particle is Markovian and arbitrarily correlated. This formula was shown to produce accurate results in comparison with more sophisticated approaches. Also, to account for the case of a low number of active sites per particle we used Monte Carlo stochastic algorithm based on Gillespie method. Simulations showed that such discrete model is required when this number is less than 10. Finally, we applied the developed approach to the simulation of immunoagglutination, assuming that the formed clusters have fractal structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-D-BRD-06: Automated Population-Based Planning for Whole Brain Radiation Therapy

Purpose: Treatment planning for whole brain radiation treatment is technically a simple process but in practice it takes valuable clinical time of repetitive and tedious tasks. This report presents a method that automatically segments the relevant target and normal tissues and creates a treatment plan in only a few minutes after patient simulation. Methods: Segmentation is performed automatically through morphological operations on the soft tissue. The treatment plan is generated by searching a database of previous cases for patients with similar anatomy. In this search, each database case is ranked in terms of similarity using a customized metric designed for sensitivity by including only geometrical changes that affect the dose distribution. The database case with the best match is automatically modified to replace relevant patient info and isocenter position while maintaining original beam and MLC settings. Results: Fifteen patients were used to validate the method. In each of these cases the anatomy was accurately segmented to mean Dice coefficients of 0.970 ± 0.008 for the brain, 0.846 ± 0.009 for the eyes and 0.672 ± 0.111 for the lens as compared to clinical segmentations. Each case was then subsequently matched against a database of 70 validated treatment plans and the best matching plan (termed auto-planned), was compared retrospectively with the clinical plans in terms of brain coverage and maximum doses to critical structures. Maximum doses were reduced by a maximum of 20.809 Gy for the left eye (mean 3.533), by 13.352 (1.311) for the right eye, and by 27.471 (4.856), 25.218 (6.315) for the left and right lens. Time from simulation to auto-plan was 3-4 minutes. Conclusion: Automated database- based matching is an alternative to classical treatment planning that improves quality while providing a cost—effective solution to planning through modifying previous validated plans to match a current patient's anatomy.

60 APPLIED LIFE SCIENCES↗

Pore-Scale Simulation of Intragranular Diffusion: Effects of Incomplete Mixing on Macroscopic Manifestations

Diffusive mass transfer into and out of intragranular micropores ("intragranular diffusion") plays an important role in the large-scale transport of some groundwater contaminants. We are interested in understanding the combined effect of pore-scale advection and intragranular diffusion on solute transport at the effective porous medium scale. To study this problem, we have developed a three-dimensional pore-scale model of fluid flow and solute transport that incorporates diffusion into and out of intragranular pore spaces. Our model is based on the Smoothed Particle Hydrodynamics (SPH) simulation method, which represents fluid and solid phases by a mesh-free particle discretization. In the pore spaces, fluid flow is simulated by discretizing the Navier-Stokes equations using the SPH approach. Solute transport is represented by advection, diffusion within the fluid phase, and diffusion between the fluid and solid phases. Our model is implemented on large-scale parallel computing hardware, allowing us to simulate millions of computational particles and represent fully three-dimensional systems of pores and grains with arbitrarily complex physical geometry. We have used this model system to perform numerical experiments using various model porous media systems, which allows us to draw comparisons between macroscopic measures computed from the pore-scale simulations (such as breakthrough curves) and those predicted by macroscopic formulations that assume complete mixing over the representative volume. In this paper we present results of 3D simulations of pore-scale flow and transport, including cases with and without intragranular diffusion, in two model porous media, one with randomly-packed uniform spherical grains and a second with randomly-packed spheres drawn from a binary grain size distribution. Breakthrough curves were computed from the 3D simulations at various transport distances. Comparable breakthrough curves were computed using 1D macroscopic models with parameters determined independently to the degree possible. Based on comparisons of the pore-scale and macroscopic model results, we draw two primary conclusions. First, non-Fickian behavior is persistent and ubiquitous at the scales considered, and most cases are better represented by a multi-rate mass transfer model even when there is no distinct secondary porosity (i.e., no intragranular diffusion). This suggests that diffusive mass transfer processes between preferential flow paths and relatively immobile zones within the primary porosity may have significant impact on transport, particular in low-concentration tails. Second, the application of mass transfer rate parameters based on an assumption of well-mixed concentrations at the pore-scale tend to overestimate the amount of mass transfer that occurs in heterogeneous pore geometries in which preferential flow leads to incomplete pore-scale lateral mixing.

Environmental Molecular Sciences Laboratory↗

Multi-scale diffuse interface modeling of multi-component two-phase flow with partial miscibility

In this paper, we introduce a diffuse interface model to simulate multi-component two-phase flow with partial miscibility based on a realistic equation of state (e.g. Peng–Robinson equation of state). Because of partial miscibility, thermodynamic relations are used to model not only interfacial properties but also bulk properties, including density, composition, pressure, and realistic viscosity. As far as we know, this effort is the first time to use diffuse interface modeling based on equation of state for modeling of multi-component two-phase flow with partial miscibility. In numerical simulation, the key issue is to resolve the high contrast of scales from the microscopic interface composition to macroscale bulk fluid motion since the interface has a nanoscale thickness only. To efficiently solve this challenging problem, we develop a multi-scale simulation method. At the microscopic scale, we deduce a reduced interfacial equation under reasonable assumptions, and then we propose a formulation of capillary pressure, which is consistent with macroscale flow equations. Moreover, we show that Young–Laplace equation is an approximation of this capillarity formulation, and this formulation is also consistent with the concept of Tolman length, which is a correction of Young–Laplace equation. At the macroscopical scale, the interfaces are treated as discontinuous surfaces separating two phases of fluids. Our approach differs from conventional sharp-interface two-phase flow model in that we use the capillary pressure directly instead of a combination of surface tension and Young–Laplace equation because capillarity can be calculated from our proposed capillarity formulation. A compatible condition is also derived for the pressure in flow equations. Furthermore, based on the proposed capillarity formulation, we design an efficient numerical method for directly computing the capillary pressure between two fluids composed of multiple components. Finally, numerical tests are carried out to verify the effectiveness of the proposed multi-scale method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive resolution simulation of polarizable supramolecular coarse-grained water models

Multiscale simulations methods, such as adaptive resolution scheme, are becoming increasingly popular due to their significant computational advantages with respect to conventional atomistic simulations. For these kind of simulations, it is essential to develop accurate multiscale water models that can be used to solvate biophysical systems of interest. Recently, a 4-to-1 mapping was used to couple the bundled-simple point charge water with the MARTINI model. Here, we extend the supramolecular mapping to coarse-grained models with explicit charges. In particular, the two tested models are the polarizable water and big multiple water models associated with the MARTINI force field. As corresponding coarse-grained representations consist of several interaction sites, we couple orientational degrees of freedom of the atomistic and coarse-grained representations via a harmonic energy penalty term. This additional energy term aligns the dipole moments of both representations. We test this coupling by studying the system under applied static external electric field. We show that our approach leads to the correct reproduction of the relevant structural and dynamical properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A numerically exact description of ultrafast vibrational decoherence in vibration-coupled electron transfer

Broadband pump–probe spectroscopy has been widely used to measure vibrational decoherence associated with the reaction coordinate in photoinduced ultrafast vibration-coupled electron transfer (VCET) reactions. These experiments provide insight into the interplay of intramolecular coordinates along the reaction coordinate. However, a general theoretical foundation for analyzing, and even for explaining rigorously, these data is lacking. In this work, we study vibrational decoherence in a model VCET reaction using the nearly exact time-dependent density matrix renormalization group simulation method. We explore how analyzing the density matrix with quantum information measures can help elucidate the evolution of vibrational coherence in simulations of dynamics. We examine how vibrational coherence is affected by electron transfer on the timescale of approximately 100 femtoseconds. Our results suggest that electron transfer, in the nonadiabatic model, changes the vibrational equilibrium position abruptly—an example of a “quantum quench” event. This explains the concomitant vibrational decoherence. We find that abrupt vibrational decoherence can be mitigated by wavepacket motion occurring on the timescale of the electron transfer.

Science & Technology - Other Topics↗

Scattering Processes from Quantum Simulation Algorithms for Scalar Field Theories

We provide practical simulation methods for scalar field theories on a quantum computer that yield improved asymptotics as well as concrete gate estimates for the simulation and physical qubit estimates using the surface code. We achieve these improvements through two optimizations. First, we consider a finite volume approach for estimating the elements of the S-matrix. This approach is appropriate in general for 1+1D and for certain low-energy elastic collisions in higher dimensions. Second, we implement our approach using a series of different fault-tolerant simulation algorithms for Hamiltonians formulated both in the field occupation basis and field amplitude basis. Our algorithms are based on either second-order Trotterization or qubitization. The cost of Trotterization in occupation basis scales as O ( λ N 7 | Ω | 3 / ( M 5 / 2 ϵ 3 / 2 ) ) where λ is the coupling strength, N is the occupation cutoff, | Ω | is the volume of the spatial lattice, M is the mass of the particles and ϵ is the uncertainty in the energy calculation used for the S -matrix determination. Qubitization in the field basis scales as O ( | Ω | 2 ( k 2 Λ + k M 2 ) / ϵ ) , where k is the cutoff in the field and Λ is a scaled coupling constant. We find in both cases that the bounds suggest physically meaningful simulations can be performed using on the order of 4 × 10 6 physical qubits and 10 12 T -gates which corresponds to roughly one day on a superconducting quantum computer with surface code and a cycle time of 100 ns. This places the simulation of scalar field theory within striking distance of the gate counts for the best available chemistry simulation results.

Hardy, Andrew [Toronto U.] (ORCID:0000000235817382↗

Hydroforming of elliptical cavities

Activities of the past several years in developing the technique of forming seamless (weldless) cavity cells by hydroforming are summarized. An overview of the technique developed at DESY for the fabrication of single cells and multicells of the TESLA cavity shape is given and the major rf results are presented. The forming is performed by expanding a seamless tube with internal water pressure while simultaneously swaging it axially. Prior to the expansion the tube is necked at the iris area and at the ends. Tube radii and axial displacements are computer controlled during the forming process in accordance with results of finite element method simulations for necking and expansion using the experimentally obtained strain-stress relationship of tube material. In cooperation with industry different methods of niobium seamless tube production have been explored. The most appropriate and successful method is a combination of spinning or deep drawing with flow forming. Several single-cell niobium cavities of the 1.3 GHz TESLA shape were produced by hydroforming. They reached accelerating gradients E acc up to 35 MV/m after buffered chemical polishing (BCP) and up to 42 MV/m after electropolishing (EP). More recent work concentrated on fabrication and testing of multicell and nine-cell cavities. Several seamless two- and three-cell units were explored. Accelerating gradients E acc of 30–35 MV/m were measured after BCP and E acc up to 40 MV/m were reached after EP. Nine-cell niobium cavities combining three three-cell units were completed at the company E. Zanon. These cavities reached accelerating gradients of E acc = 30–35 MV/m. One cavity is successfully integrated in an XFEL cryomodule and is used in the operation of the FLASH linear accelerator at DESY. Additionally the fabrication of bimetallic single-cell and multicell NbCu cavities by hydroforming was successfully developed. Several NbCu clad single-cell and double-cell cavities of the TESLA shape have been fabricated. The clad seamless tubes were produced using hot bonding or explosive bonding and subsequent flow forming. The thicknesses of Nb and Cu layers in the tube wall are about 1 and 3 mm respectively. The rf performance of the best NbCu clad cavities is similar to that of bulk Nb cavities. The highest accelerating gradient achieved was 40 MV/m. The advantages and disadvantages of hydroformed cavities are discussed in this paper.

36 MATERIALS SCIENCE↗

SU-E-T-577: Commissioning of a Deterministic Algorithm for External Photon Beams

Purpose: We report commissioning results for a deterministic algorithm for external photon beam treatment planning. A deterministic algorithm solves the radiation transport equations directly using a finite difference method, thus improve the accuracy of dose calculation, particularly under heterogeneous conditions with results similar to that of Monte Carlo (MC) simulation. Methods: Commissioning data for photon energies 6 – 15 MV includes the percentage depth dose (PDD) measured at SSD = 90 cm and output ratio in water (Spc), both normalized to 10 cm depth, for field sizes between 2 and 40 cm and depths between 0 and 40 cm. Off-axis ratio (OAR) for the same set of field sizes was used at 5 depths (dmax, 5, 10, 20, 30 cm). The final model was compared with the commissioning data as well as additional benchmark data. The benchmark data includes dose per MU determined for 17 points for SSD between 80 and 110 cm, depth between 5 and 20 cm, and lateral offset of up to 16.5 cm. Relative comparisons were made in a heterogeneous phantom made of cork and solid water. Results: Compared to the commissioning beam data, the agreement are generally better than 2% with large errors (up to 13%) observed in the buildup regions of the FDD and penumbra regions of the OAR profiles. The overall mean standard deviation is 0.04% when all data are taken into account. Compared to the benchmark data, the agreements are generally better than 2%. Relative comparison in heterogeneous phantom is in general better than 4%. Conclusion: A commercial deterministic algorithm was commissioned for megavoltage photon beams. In a homogeneous medium, the agreement between the algorithm and measurement at the benchmark points is generally better than 2%. The dose accuracy for a deterministic algorithm is better than a convolution algorithm in heterogeneous medium.

07 ISOTOPE AND RADIATION SOURCES↗