Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Screening design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Experimental clean combustor program, phase 1

Full annular versions of advanced combustor designs, sized to fit within the CF6-50 engine, were defined, manufactured, and tested at high pressure conditions. Configurations were screened, and significant reductions in CO, HC, and NOx emissions levels were achieved with two of these advanced combustor design concepts. Emissions and performance data at a typical AST cruise condition were also obtained along with combustor noise data as a part of an addendum to the basic program. The two promising combustor design approaches evolved in these efforts were the Double Annular Combustor and the Radial/Axial Combustor. With versions of these two basic combustor designs, CO and HC emissions levels at or near the target levels were obtained. Although the low target NOx emissions level was not obtained with these two advanced combustor designs, significant reductions were relative to the NOx levels of current technology combustors. Smoke emission levels below the target value were obtained.

Bahr, D. W.↗

Experimental and CFD Investigation of the Titled Jet Behavior in the Zero Boil-Off Tank (ZBOT) Experiment

Screens are used in cryogenic storage tanks to diffuse the incoming gas or liquid injection/flow into the tank. Meshed screens were also used in the jet mixing pressure control tests of the Zero Boil-Off Tank (ZBOT) Experiment which was recently performed aboard the International Space Station (ISS). The ZBOT pressure control studies used a liquid jet that was intended to be aligned with the longitudinal axis of the tank. A cartridge consisting of a honeycomb flow straightener and two screen diffusers, one upstream of the honeycomb, and one downstream, were designed to obtain the desired velocity profile in a manner that would be consistent in all the tests and could also be used as an input to the CFD simulations. Unfortunately, during the flight operations, the Digital Particle Image Velocimetry (DPIV) measurements indicated that the jet actually exited the nozzle at an angle to the main axis. This unexpected tilt affected the motion and deformation of the ullage during the pressure control tests, influencing the initial pressure drops. Upon disassembling the experiment hardware, it was discovered that the screen diffuser upstream of the honeycomb was clogged with debris. Since this behavior is important, not only to the follow-on ZBOT-NC experiment, but also to the operation of cryogenics storage tanks in general, a series of ground-based experiments and parametric CFD model simulations were performed to understand and characterize the tilted flow in terms of the clogged area of the upstream screen and the jet velocity. The experimental and CFD results surprisingly and non-intuitively showed that although the modification of the flow originated from the clogging of the upstream screen, the presence of the downstream unclogged screen was also necessary to produce the tilted jet. Two different CFD models were used for the numerical simulations, and only the one using a porous media formulation to capture the screen pressure drop was able to produce the correct tilting behavior. Parametric runs with the porous media CFD model were used to characterize the jet tilt in terms of the blockage area and jet velocity for both the future ZBOT-NC Experiment and other propellant tank applications. Supported by NASA Biological & Physical Sciences (BPS) Division, Physical Sciences Research Program, NASA HQ, USA.

Cryogenic Fluid Management↗

Performance of a 1.57 pressure-ratio transonic fan stage with a screen-induced 90 deg circumferential inlet flow distortion

A transonic fan stage having a design pressure ratio of 1.57 was tested with a 90 degree circumferential distortion imposed on the inlet flow. The rotor diameter was approximately 50.8 cm, and the design pressure ratio was 1.60 at a tip speed of 425 m/sec. Overall performance at 70 and 100 percent of design speed showed a loss of stall pressure ratio and flow range at design speed and no significant loss in stall pressure ratio at 70 percent of design speed. Detailed flow measurements are presented to show the rotor-upstream flow interactions and the attenuation and amplification properties through the stage.

Sanger, N. L.↗

Screen Channel Liquid Acquisition Device Outflow Tests in Liquid Hydrogen

This paper presents experimental design and test results of the recently concluded 1-g inverted vertical outflow testing of two 325x2300 full scale liquid acquisition device (LAD) channels in liquid hydrogen (LH2). One of the channels had a perforated plate and internal cooling from a thermodynamic vent system (TVS) to enhance performance. The LADs were mounted in a tank to simulate 1-g outflow over a wide range of LH2 temperatures (20.3 - 24.2 K), pressures (100 - 350 kPa), and flow rates (0.010 - 0.055 kg/s). Results indicate that the breakdown point is dominated by liquid temperature, with a second order dependence on mass flow rate through the LAD. The best performance is always achieved in the coldest liquid states for both channels, consistent with bubble point theory. Higher flow rates cause the standard channel to break down relatively earlier than the TVS cooled channel. Both the internal TVS heat exchanger and subcooling the liquid in the propellant tank are shown to significantly improve LAD performance.

Liquid Acquisition Device↗

Alginate based 3D hydrogels as an in vitro co-culture model platform for the toxicity screening of new chemical entities

Prediction of human response to potential therapeutic drugs is through conventional methods of in vitro cell culture assays and expensive in vivo animal testing. Alternatives to animal testing require sophisticated in vitro model systems that must replicate in vivo like function for reliable testing applications. Advancements in biomaterials have enabled the development of three-dimensional (3D) cell encapsulated hydrogels as in vitro drug screening tissue model systems. In this study, we have developed an in vitro platform to enable high density 3D culture of liver cells combined with a monolayer growth of target breast cancer cell line (MCF-7) in a static environment as a representative example of screening drug compounds for hepatotoxicity and drug efficacy. Alginate hydrogels encapsulated with serial cell densities of HepG2 cells (10{sup 5}-10{sup 8} cells/ml) are supported by a porous poly-carbonate disc platform and co-cultured with MCF-7 cells within standard cell culture plates during a 3 day study period. The clearance rates of drug transformation by HepG2 cells are measured using a coumarin based pro-drug. The platform was used to test for HepG2 cytotoxicity 50% (CT{sub 50}) using commercially available drugs which further correlated well with published in vivo LD{sub 50} values. The developed test platform allowed us to evaluate drug dose concentrations to predict hepatotoxicity and its effect on the target cells. The in vitro 3D co-culture platform provides a scalable and flexible approach to test multiple-cell types in a hybrid setting within standard cell culture plates which may open up novel 3D in vitro culture techniques to screen new chemical entity compounds. - Graphical abstract: Display Omitted Highlights: > A porous support disc design to support the culture of desired cells in 3D hydrogels. > Demonstrated the co-culture of two cell types within standard cell-culture plates. > A scalable, low cost approach to toxicity screening involving multiple cell types.

60 APPLIED LIFE SCIENCES↗

Mechanical component screening for scanner

The critical mechanical components of the scan mirror mechanism are described and their evaluation and screening procedures are discussed. A bumper/damper unit is used in the design to reverse motion of the mirror and effect scan and retrace cycles. A wear evaluation was conducted on the bumper impact surfaces that established nylon 6-10 as an acceptable material. The elastomeric dampers were subjected to thermal vacuum tests for condensables and outgassing as well as parametric life tests. The flexure pivots that support the mirror were tested to establish a curve of stress plotted as a function of cycles to failure for rotational operation. The pivots met the life requirement of 150,000,000 cycles at a + or - 2.9 deg amplitude during fatigue testing. Screening procedures were established for dampers and flexure pivots to obtain flight quality components.

Olson, J. L.↗

Design, Fabrication, and Testing of a Composite Rack Prototype in Support of the Deep Space Habitat Program

In support of the Deep Space Habitat project a number of composite rack prototypes were developed, designed, fabricated and tested to various extents ( with the International Standard Payload Rack configuration, or crew quarters, as a baseline). This paper focuses specifically on a composite rack prototype with a direct tie in to Space Station hardware. The outlined prototype is an all composite construction, excluding metallic fasteners, washers, and their associated inserts. The rack utilizes braided carbon composite tubing for the frame with the sidewalls, backwall and flooring sections utilizing aircraft grade composite honeycomb sandwich panels. Novel additively manufactured thermoplastic joints and tube inserts were also developed in support of this effort. Joint and tube insert screening tests were conducted at a preliminary level. The screening tests allowed for modification, and enhancement, of the fabrication and design approaches, which will be outlined. The initial joint tests did not include mechanical fasteners. Adhesives were utilized at the joint to composite tube interfaces, along with mechanical fasteners during final fabrication (thus creating a stronger joint than the adhesive only variant). In general the prototype was focused on a potential in-space assembly approach, or kit-of-parts construction concept, which would not necessarily require the inclusion of an adhesive in the joint regions. However, given the tie in to legacy Station hardware (and potential flight loads with imbedded hardware mass loadings), the rack was built as stiff and strong as possible. Preliminary torque down tests were also conducted to determine the feasibility of mounting the composite honeycomb panels to the composite tubing sections via the additively manufactured tube inserts. Additional fastener torque down tests were also conducted with inserts (helicoils) imbedded within the joints. Lessons learned are also included and discussed.

Smith, Russ↗

Versatile allelic replacement and self-excising integrative vectors for plasmid genome mutation and complementation

ABSTRACT The ability to better understand the function of proteins expressed by bacteria has typically relied upon the development of genetic mutant strains. This approach has been especially challenging for plasmid-encoded genes, as most of the previously described allelic replacement vectors are inefficient for plasmid genome mutation as they either rely on plasmid-derived counterselection toxins or depend on other strategies suchsacB,tetA, andrpsLwhich have been proven to be less efficient for mutant selection. Integrative vectors lack chromophore indicators, thus requiring laborious screening or excision of the vector’s backbone relies on the introduction of a flippase (FLP)-expressing plasmid. The allelic replacement vector, designated here as pDG1, expresses an X-Gal hydrolyzing enzyme (BgaB) that can be used for blue/white screening allowing identification of colonies that integrated and successfully removed the mutagenesis plasmid without a bias for those still carrying it. pDG1 was further improved by including the rhamnose-inducible Tse2 toxin as a potent counterselection system. The efficacy of pDG1 was validated by deleting portions of the plasmid-encoded VirB4/D4 type IV secretion system and aerobactin-synthesizing operons inSalmonella enterica. The integrative vectors, which contain an ΦC31attPsite and genes encoding ΦC31 integrase (int), can seamlessly integrate to target ΦC31attBonSalmonellaplasmids or chromosome. These vectors were improved by insertingbgaBand FLP-encoding genes so that, following integration, most of the vector’s backbone encompassingint,bgaB, and FLP genes can be excised by FLP, without the need for another FLP-expressing vector, creating white colonies carrying a stably integrated target gene. As such, we were able to integrate a 9.3-kb DNA fragment toSalmonellachromosome and flipped out most of the integrated vector in one step, leaving the target fragment in the chromosome. IMPORTANCE In spite of the dissemination of multidrug-resistant plasmids among Gram-negative pathogens, including those carrying virulence genes, vector tools for studying plasmid-born genes are lacking. The allelic replacement vectors can be used to generate plasmid or chromosomal mutations including markless point mutations. This is the first report describing a self-excising integrative vector that can be used as a stable single-copy complementing tool to study medically important pathogens includingin vivostudies without the need for antibiotic selection. Overall, our newly developed vectors can be applied for the assessment of the function of plasmid-encoded genes by specifically creating mutations, moving large operons between plasmids and to/from the chromosome, and complementing phenotypes associated with gene mutation. Furthermore, the vectors express chromophores for the detection of target gene modification or colony isolation, avoiding time-consuming screening procedures.

Microbiology↗

Counterweight for Long Reach Robotic Arm

Maintenance for vital systems proves challenging due to their location: tucked up and behind components. Pinpointing the precise location of errors presents difficulty when relying solely on the human eye. The solution to this issue arises in the form of a Long Reach Robotic Arm. An adequately balanced robot with several individually controlled links contains the capability to maneuver around obstructing components to locate the points of failure with accuracy. The design process for such a robot begins with the writing of a program. The program intends to visualize how the Long Reach Robotic Arm will move in 2D space by printing a select number of lines representing each arm link to the screen and controlling each link through the keyboard. This code substantially simplifies the design process for the multi-linked arm. The next step in the Long Reach Robotic Arm design process is the development of the arm and its counterweight system. The clear division of this work allows two interns to work on this project: one assumes responsibility for the arm, and the other for the counterweight. I undertook the design for the counterbalance. My half of the project is essential for maintaining safety as an extended multi-linked robot arm presents the challenge of preserving stability. The best method to supply a balance to the robot, even in extension, is a mobile counterweight with a compact design.

43 PARTICLE ACCELERATORS↗

Compliant Tactile Sensors

Tactile sensors are currently being designed to sense interactions with human hands or pen-like interfaces. They are generally embedded in screens, keyboards, mousepads, and pushbuttons. However, they are not well fitted to sense interactions with all kinds of objects. A novel sensor was originally designed to investigate robotics manipulation where not only the contact with an object needs to be detected, but also where the object needs to be held and manipulated. This tactile sensor has been designed with features that allow it to sense a large variety of objects in human environments. The sensor is capable of detecting forces coming from any direction. As a result, this sensor delivers a force vector with three components. In contrast to most of the tactile sensors that are flat, this one sticks out from the surface so that it is likely to come in contact with objects. The sensor conforms to the object with which it interacts. This augments the contact's surface, consequently reducing the stress applied to the object. This feature makes the sensor ideal for grabbing objects and other applications that require compliance with objects. The operational range of the sensor allows it to operate well with objects found in peoples' daily life. The fabrication of this sensor is simple and inexpensive because of its compact mechanical configuration and reduced electronics. These features are convenient for mass production of individual sensors as well as dense arrays. The biologically inspired tactile sensor is sensitive to both normal and lateral forces, providing better feedback to the host robot about the object to be grabbed. It has a high sensitivity, enabling its use in manipulation fingers, which typically have low mechanical impedance in order to be very compliant. The construction of the sensor is simple, using inexpensive technologies like silicon rubber molding and standard stock electronics.

Torres-Jara, Eduardo R.↗

Synthesis and SAR of novel tricyclic quinoxalinone inhibitors of poly(ADP-ribose)polymerase-1 (PARP-1)

Based on screening hit 1, a series of tricyclic quinoxalinones have been designed and evaluated for inhibition of PARP-1. Substitutions at the 7- and 8-positions of the quinoxalinone ring led to a number of compounds with good enzymatic and cellular potency. The tricyclic quinoxalinone class is sensitive to modifications of both the amine substituent and the tricyclic core. The synthesis and structure-activity relationship studies are presented.

59 BASIC BIOLOGICAL SCIENCES↗

Identification of quinazoline based inhibitors of IRAK4 for the treatment of inflammation

Interleukin-1 receptor associated kinase 4 (IRAK4) has been implicated in IL-1R and TLR based signaling. Therefore selective inhibition of the kinase activity of this protein represents an attractive target for the treatment of inflammatory diseases. Medicinal chemistry optimization of high throughput screening (HTS) hits with the help of structure based drug design led to the identification of orally-bioavailable quinazoline based IRAK4 inhibitors with excellent pharmacokinetic profile and kinase selectivity. These highly selective IRAK4 compounds show activity in vivo via oral dosing in a TLR7 driven model of inflammation.

59 BASIC BIOLOGICAL SCIENCES↗

Computational methods in solution-based plastics purification

Plastic waste can be recycled into resins with near-virgin properties by solution-based purification processes that selectively dissolve polymers, remove contaminants, or detach printing residues. Here, in this review, we examine computational methods for predicting the behavior governing solution-based plastic purification, motivated by the vast polymer–solvent–contaminant compositional space. We discuss thermodynamic and machine learning methods for predicting polymer–solvent and polymer–contaminant interaction and review physics-based molecular dynamics simulations that resolve molecular-scale phenomena within polymer matrices inaccessible to screening methods. We highlight how these methods have informed experimental design for dissolution-based recycling and solvent-based contaminant removal. Finally, we discuss the prospective role of agentic AI in integrating these computational tools with real-time sorting data to adapt purification conditions to the compositional variability of real post-consumer feedstocks. This review charts a path toward computationally guided solution-based purification workflows that can respond to the complexity inherent in plastic waste streams.

Altamimi, Ali [Univ. of Wisconsin, Madison, WI (Un↗

Hydrogen-Bond-Driven Chemical Separations: Elucidating the Interfacial Steps of Self-Assembly in Solvent Extraction

Chemical separations, particularly liquid extractions, are pervasive in academic and industrial laboratories, yet a mechanistic understanding of the events governing their function are obscured by interfacial phenomena that are notoriously difficult to measure. In this work, we investigate the fundamental steps of ligand self-assembly as driven by changes in the interfacial H-bonding network using vibrational sum frequency generation. Our results show how the bulk pH modulates the interfacial structure of extractants at the buried oil/aqueous interface via the formation of unique H-bonding networks that order and bridge ligands to produce self-assembled aggregates. These extended H-bonded structures are key to the subsequent extraction of Co2+ from the aqueous phase in promoting micelle formation and subsequent ejection of the said micelle into the oil phase. The combination of static and time-resolved measurements reveals the events underlying complexities of liquid extractions at high [Co2+]:[ligand] ratios by showing an evolution of interfacially assembled structures that are readily tuned on a chemical basis by altering the compositions of the aqueous phase. The results of this work point to new principles to design-applied separations through the manipulation of surface charge, electrostatic screening, and the associated H-bonding networks that arise at the interface to facilitate organization and subsequent extraction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Discovery of first-in-class inhibitors of ASH1L histone methyltransferase with anti-leukemic activity

ASH1L histone methyltransferase plays a crucial role in the pathogenesis of different diseases, including acute leukemia. While ASH1L represents an attractive drug target, developing ASH1L inhibitors is challenging, as the catalytic SET domain adapts an inactive conformation with autoinhibitory loop blocking the access to the active site. Here, by applying fragment-based screening followed by medicinal chemistry and a structure-based design, we developed first-in-class small molecule inhibitors of the ASH1L SET domain. The crystal structures of ASH1L-inhibitor complexes reveal compound binding to the autoinhibitory loop region in the SET domain. When tested in MLL leukemia models, our lead compound, AS-99, blocks cell proliferation, induces apoptosis and differentiation, downregulates MLL fusion target genes, and reduces the leukemia burden in vivo. This work validates the ASH1L SET domain as a druggable target and provides a chemical probe to further study the biological functions of ASH1L as well as to develop therapeutic agents.

60 APPLIED LIFE SCIENCES↗

Crystal structure of the human PRPK–TPRKB complex

Mutations of the p53-related protein kinase (PRPK) and TP53RK-binding protein (TPRKB) cause Galloway-Mowat syndrome (GAMOS) and are found in various human cancers. We have previously shown that small compounds targeting PRPK showed anti-cancer activity against colon and skin cancer. Here we present the 2.53 Å crystal structure of the human PRPK-TPRKB-AMPPNP (adenylyl-imidodiphosphate) complex. The structure reveals details in PRPK-AMPPNP coordination and PRPK-TPRKB interaction. PRPK appears in an active conformation, albeit lacking the conventional kinase activation loop. We constructed a structural model of the human EKC/KEOPS complex, composed of PRPK, TPRKB, OSGEP, LAGE3, and GON7. Disease mutations in PRPK and TPRKB are mapped into the structure, and we show that one mutation, PRPK K238Nfs*2, lost the binding to OSGEP. Our structure also makes the virtual screening possible and paves the way for more rational drug design.

59 BASIC BIOLOGICAL SCIENCES↗