Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Safety Case”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

A Chemistry Based Criticality Safety Evaluation of the HM-Process Mixer Settlers

The criticality safety of Savannah River Site's H Canyon two cycle uranium extraction and purification process, called the HM process, is examined. Explicit Monte Carlo models of the multi-stage mixer-settlers are generated for the first time using the KENO-VI module of the SCALE 6.1 code package and spanning normal operating conditions and a wide range of potential upset conditions with stagewise compositions based directly on SEPHIS Mod-4 chemistry models of the same conditions. To achieve industrial scale processing, mixer-settlers are often not geometrically favorable to prevent criticality so other means must be used for criticality safety, namely control of fissile concentration and mass. Historically, the worst case upset is a reflux condition resulting from a stream flow rate, temperature, or composition that is off from the normal operating conditions. A reflux is considered to be the state in which the fissile material is not proceeding in the desired direction, i.e. is stripping rather than extracting or vice versa. The criticality safety analyses which set the current operational limits were conducted many years ago with less sophisticated codes and only loosely tied criticality to chemistry. Those analyses conservatively assumed that a reflux changed the behavior of the mixer-settler such that the fissile content collected continuously in only three stages of the mixer-settler, at a rate based on the SEPHIS modeling, until criticality occurred. This implies that under some condition the distribution coefficient of the fissile material either goes to infinity or zero, which is not physically achievable. In such a scenario, the operator would have some amount of time to react and correct the problem before sufficient fissile material built up in the mixer-settler and caused a criticality. In reality, an upset in a stream would cause the process to transition to a new, though undesired, equilibrium state of operation. The distribution coefficients would change, but would not diverge. In this work, aqueous and organic streams are modeled for both the mixer and the settler region of each stage of each bank using chemical distribution data from SEPHIS and solving the chemical equations for a wide range of operational parameters spanning normal and upset conditions. Conservative assumptions are made regarding enrichment and reflection and the whole bank multiplication factor is evaluated using discrete stage-wise compositions. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ultrasound-guided percutaneous catheter drainage of various types of ruptured amebic liver abscess: a report of 117 cases from a highly endemic zone of India

Objective: To determine the efficacy and safety ultrasound-guided percutaneous catheter drainage (US-PCD) in management of various types of ruptured amebic liver abscess including free rupture (FR) with diffuse intraperitoneal fluid collections (DIFC). Methods: This study analyzed 117 patients with ruptured ALA who underwent US-PCD. The indication for US-PCD was failure to respond to conservative treatment and/or percutaneous needle aspiration. Results: Majority of patients were locally fermented alcohol abusers (95%), and malnourished (75%). Ninety-eight patients had intraperitoneal rupture including 66 contained rupture (CR) with localized intraperitoneal fluid collection (LIFC) and 32 FR with DIFC. Pleuropulmonary complication was found in 19 patients including 13 pleural and 6 pulmonary. A total of 333 catheters were used to drain 202 abscess cavities and associated fluid collections. US-PCD was technically and clinically successful in all cases. Multiple sessions (median 2; range 2–5) of PCD required with upsizing the catheter (median 14 F; range 14–20 F) and placement of additional catheter in 26 (22%) patients. The patients with FR with DIFC required more number of catheters (p = 0.01) and had longer hospital stay (p = 0.01). No major procedure related complication was observed. Six patients developed secondary bacterial infection; two of them presented with cavito-cutaneous fistula at catheter insertion site, and one with cholangitis due to biliary stricture formation necessitating subsequent endoscopic treatment. Post-procedural death occurred from sepsis in a patient with FR. Conclusion: US-PCD is a safe and effective mode of treatment for ruptured ALA including FR with DIFCs. We recommend PCD as a first-line therapy for ruptured ALA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Aerospace Safety Advisory Panel

This report covers the activities of the Aerospace Safety Advisory Panel (ASAP) for calendar year 1998-a year of sharp contrasts and significant successes at NASA. The year opened with the announcement of large workforce cutbacks. The slip in the schedule for launching the International Space Station (ISS) created a 5-month hiatus in Space Shuttle launches. This slack period ended with the successful and highly publicized launch of the STS-95 mission. As the year closed, ISS assembly began with the successful orbiting and joining of the Functional Cargo Block (FGB), Zarya, from Russia and the Unity Node from the United States. Throughout the year, the Panel maintained its scrutiny of NASAs safety processes. Of particular interest were the potential effects on safety of workforce reductions and the continued transition of functions to the Space Flight Operations Contractor. Attention was also given to the risk management plans of the Aero-Space Technology programs, including the X-33, X-34, and X-38. Overall, the Panel concluded that safety is well served for the present. The picture is not as clear for the future. Cutbacks have limited the depth of talent available. In many cases, technical specialties are "one deep." The extended hiring freeze has resulted in an older workforce that will inevitably suffer significant departures from retirements in the near future. The resulting "brain drain" could represent a future safety risk unless appropriate succession planning is started expeditiously. This and other topics are covered in the section addressing workforce. In the case of the Space Shuttle, beneficial and mandatory safety and operational upgrades are being delayed because of a lack of sufficient present funding. Likewise, the ISS has little flexibility to begin long lead-time items for upgrades or contingency planning.

Source record↗

Safety status of space radioisotope and reactor power sources

The current overall safety criterion for both radioisotope and reactor power sources is containment or immobilization in the case of a reentry accident. In addition, reactors are designed to remain subcritical under conditions of land impact or water immersion. A very extensive safety test and analysis program was completed on the radioisotope thermoelectric generators (RTGs) in use on the Galileo spacecraft and planned for use on the Ulysses spacecraft. The results of this work show that the RTGs will pose little or no risk for any credible accident. The SP-100 space nuclear reactor program has begun addressing its safety criteria, and the design is planned to be such as to ensure meeting the various safety criteria. Preliminary mission risk analyses on SP-100 show the expected value population dose from postulated accidents on the reference mission to be very small. It is concluded that the current US nuclear power sources are the safest flown.

Bennett, Gary L.↗

A Statistical Approach to Safety Margin Evaluation of Irradiation Experiments in the ATR

The current safety basis of the INL Advanced Test Reactor requires that irradiation experiments meet minimum safety margins to critical heat flux and flow instability during anticipated reactor fault conditions. Compliance to these requirements may be demonstrated by calculating safety margins using safety factors that account for uncertainties, or using a statistical approach to quantify the uncertainty in the safety margins. Safety margins obtained from the first approach are conservative since the individual events leading to the cumulative safety factor are assumed to occur simultaneously at their maximum uncertainty. The statistical approach is less conservative in the case where the uncertainties are not too large, and may reduce the conservatism resulting from an overabundance of safety factors. This report describes the procedure for safety margin evaluation using a statistical approach and identifies the important thermal-hydraulic variables to consider in an uncertainty analysis. In particular, safety margins to critical heat flux and flow instability are evaluated for three recent high power fueled experiments (MP-1, FSP-1 and AFIP-6) using RELAP5 coupled to RAVEN to perform statistical analysis and uncertainty quantification. The results demonstrate adequate safety margins to critical heat flux and flow instability during an anticipated loss of commercial power to the reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Endovascular Embolization of Post-tonsillectomy Pseudoaneurysm: A Single-Center Case Series

Objective: The aim of this study was to evaluate the efficacy and safety of endovascular embolization of post-tonsillectomy pseudoaneurysm with the usage of monomeric n-butyl-2-cyanoacrylate (NBCA) glue as a first intention. Methods: We retrospectively analyzed the technical details and clinical outcome of ten consecutive children presented with delayed post-tonsillectomy bleeding, caused by lingual or facial artery pseudoaneurysm, which was treated by endovascular embolization. Results: Seven patients had lingual artery pseudoaneurysm, and three patients had injury of a common linguo-facial trunk. Eight patients were treated by endovascular embolization using NBCA glue, and two patients had to be embolized using microcoils. All patients were successfully embolized with no clinical complications. One patient suffered from bleeding during the interventional procedure that was controlled by NBCA which infiltrated normal branches with no clinical sequelae. Conclusion: NBCA glue can be used as an effective appropriate embolizing material in endovascular embolization of post-tonsillectomy pseudoaneurysm. However, certain precautions are mandatory to avoid distal infiltration of normal arteries or proximal reflux that may endanger the internal carotid artery. Level of Evidence: Level 4, case series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unlocking the Spacecraft and Human Habitat Microbiome to Enable the Next Generation of Space Exploration

Planetary protection is the discipline that prevents harmful contamination of the solar system during exploration activities. The current international guidelines and NASA policy addressing biological contamination on spacecraft surfaces contains prescriptive guidelines of spore requirements (e.g., 300 spores/m2, 5×105 spores per spacecraft) applicable to spacecraft bound for Mars. To verify these requirements spacecraft engineers sample spacecraft surfaces throughout the assembly, test and launch operations phase of the mission using damp water cotton swabs and polyester wipes. After sampling, the potential biological contamination is enumerated using a series of traditional microbiology techniques to include sonication, heat shocking at 80°C for 15min to select for spores, and growth on tryptic soy agar at 32°C for 72 hours. To enable crewed missions to Mars and robotic exploration of the Ocean Worlds a risk informed decision making / performance-based approach to assess biological contamination offers a promising solution in the trade space. Recognizing the need for a performance-based approach, NASA’s new Planetary Protection policies now incorporate the agility for missions to be able to leverage a performance or prescriptive approach. One of top contenders in the option space is a coupled quantitative, descriptive and functional based approach to be able to assess the quantity, types and capabilities of the biological contamination present on spacecraft surfaces. A tailored, mission by mission assurance case could then be formulated by building an argument around the target body, projected capabilities surrounding the types of organisms their potential for survival and proliferation, and ability to be transported on the target body to contaminate an area of biological interest. A performance-based requirement would then be used to demonstrate the mission’s compliance in protecting the planetary environment safety objectives. This symposium talk will showcase the background and need case for NASA to develop such a capability as well as provide an update on the efforts underway in developing a transparent and responsible performance-based approach to biological contamination assessments on spacecraft surfaces.

Habitat Microbiome↗

Assessment of herbal medicinal products: Challenges, and opportunities to increase the knowledge base for safety assessment

Although herbal medicinal products (HMP) have been perceived by the public as relatively low risk, there has been more recognition of the potential risks associated with this type of product as the use of HMPs increases. Potential harm can occur via inherent toxicity of herbs, as well as from contamination, adulteration, plant misidentification, and interactions with other herbal products or pharmaceutical drugs. Regulatory safety assessment for HMPs relies on both the assessment of cases of adverse reactions and the review of published toxicity information. However, the conduct of such an integrated investigation has many challenges in terms of the quantity and quality of information. Adverse reactions are under-reported, product quality may be less than ideal, herbs have a complex composition and there is lack of information on the toxicity of medicinal herbs or their constituents. Nevertheless, opportunities exist to capitalise on newer information to increase the current body of scientific evidence. Novel sources of information are reviewed, such as the use of poison control data to augment adverse reaction information from national pharmacovigilance databases, and the use of more recent toxicological assessment techniques such as predictive toxicology and omics. The integration of all available information can reduce the uncertainty in decision making with respect to herbal medicinal products. The example of Aristolochia and aristolochic acids is used to highlight the challenges related to safety assessment, and the opportunities that exist to more accurately elucidate the toxicity of herbal medicines.

60 APPLIED LIFE SCIENCES↗

Regulatory Consideration on Decommissioning Facilitation of Nuclear Power Plants In Korea

As the number of decommissioning NPPs worldwide increases, the necessity of decommissioning feasibility design at the initial design/construction stage of NPP is emphasized. Also as demand for NPP decommissioning increase, the generation of large amount of radioactive waste and environment contamination are expected. Based on the decommissioning experiences of nuclear facilities, it is recognized that the specific design and operational procedure are essentially required to minimize the radioactive waste generation and radiation exposure during decommissioning. Recently the legal framework of decommissioning in Korea was enhanced through the revision of Nuclear Safety Act (NSA) and its subordinate status in 2015. On the other hand, the Korean first NPP, Kori unit 1, will be scheduled permanently shut-down in mid-2017. The Korean regulatory body have experience for decommissioning of small-sized nuclear facilities like research reactors and nuclear fuel cycle facility. However we have no experience on decommissioning of NPP in Korea. Therefore the comprehensive and systematic technical standards and guidelines on safety review and inspection should be required for the Korean first case on decommissioning of NPP. According to the revised NSA, NPP operators in Korea should submit the decommissioning plan (DP) for the permanent shut-down NPP as well as the existing operating NPPs. The operator shall prepare and submit the design features and measures for decommissioning facilitation as one of DP items and regulatory body shall review the feasibility of decommissioning. Therefore the safety review guideline for those decommissioning facilitation should be required. In this paper, we studied the overseas safety requirements, design features and operational procedures for decommissioning facilitation. Through the overseas survey results, the regulatory position and major management plan were proposed for development of detailed implementation guideline on decommissioning facilitation of NPPs in Korea.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Risk assessment of safety-critical data communication in digital safety feature control system - 205

As one of the safety-critical systems in Advanced Power Reactor-1400 (APR-1400) nuclear power plant (NPP), the Engineered Safety Feature-Component Control System (ESF-CCS) employs safety data link and network communication for transmitting safety component actuation to effectively facilitate various safety-critical field controllers. However, data communication failure risk in the ESF-CCS has yet to be fully quantified, the probability that a safety-critical system in digitalized NPP becomes unsafe due to a network failure must be evaluated to quantify the risk of digital I and C system. In this study, a fault tree model was developed to assess the data link and data network failure-induced unavailability of a safety-critical system function used to generate an automated control signal for actuating design basis accident mitigation equipment. Especially, the risk of data communication failure in a digital safety feature control system was analyzed in consideration of interconnection between safety-critical controllers and the fault-tolerant algorithm implemented in the network configuration. Based on the developed fault tree model, case studies were performed to quantitatively assess the unavailability of ESF-CCS signal generation due to safety data link and network failure and their risk effect on safety signal generation unavailability. This study is expected to provide risk information on the safety-critical data communication in a digitalized NPP instrumentation and control system. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Controversies in water management: Frames and mental models

Controversies in decision and policy-making processes can be analysed using frame reflection and mental model mapping techniques. The purpose of the method presented in this paper is to improve the quality of the information and interpretations available to decision makers, by surfacing and juxtaposing the different frames of decision makers, experts, and special interests groups. The research provides a new method to analyse frames. It defines a frame to consist of perspectives and a mental model, which are in close interaction (through second order learning processes). The mental model acts like a 'filter' through which the problem situation is observed. Five major perspective types guide the construction of meaning out of the information delivered by the mental model, and determine what actors see as their interests. The perspective types are related to an actor's institutional and personal position in the decision making process. The method was applied to a case, in order to test its viability. The case concerns the decision making process and environmental impact assessment procedure for the improvement of dike ring 53 in the Netherlands, which was initiated by the Dutch 'Flood Defences Act 1996'. In this specific case the perspectives and mental models of stakeholders were elicited to explain controversies. The case was analysed with regard to the conflicts emerging between stakeholders, on an individual level. The influence of institutional embedding of individuals on the use of information and the construction of meaning, and the limits of a participatory approach were analysed within the details of controversies that emerged during the case analysis. Complicating factor appeared to be the interaction between national dike safety norms (short term) and local water management problems (long term). Revealed controversies mainly concerned disputes between an organisational and a technical perspective. But also disputes on distribution of responsibilities between different institutes, on legal and political liability, and on funding issues, involving persons of both perspectives, were found. The case reveals a lack of possibilities to search for an integrated solution which involves all levels of authority, and a lack of possibilities to discuss the additional problems that were raised by the integrated approach in the initial phase of the case project. The complex and unstructured nature of the problem situation caused the traditional substantive approach to fail to deliver a good solution. Legal, socio-economic and institutional factors ultimately dominated the decision making process.

54 ENVIRONMENTAL SCIENCES↗

Criticality Safety Validation of SCALE 6.1 (Revised)

The computational bias of criticality safety computer codes must be established through the validation of the codes to critical experiments. A large collection of suitable experiments has been vetted by the International Criticality Safety Benchmark Experiment Program (ICSBEP) and made available in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (IHECSBE). A total of more than 350 cases from this reference have been prepared and reviewed within the Verified, Archived Library of Inputs and Data (VALID) maintained by the Reactor and Nuclear Systems Division at Oak Ridge National Laboratory. The performance of the KENO V.a and KENO-VI Monte Carlo codes within the SCALE 6.1 code system with ENDF/B-VII.0 cross-section data in 238-group and continuous energy is assessed using the VALID models of benchmark experiments. The TSUNAMI tools for sensitivity and uncertainty analysis are utilized to examine some systems further in an attempt to identify potential causes of unexpected results. The critical experiments available for validation of the KENO V.a code cover eight different broad categories of systems. These systems use a range of fissile materials including a range of uranium enrichments, various plutonium isotopic vectors, and mixed uranium/plutonium oxides. The physical form of the fissile material also varies and is represented as metal, solutions, or arrays of rods or plates in a water moderator. The neutron energy spectra of the systems also vary and cover both fast and thermal spectra. Over 300 of the total cases used utilize the KENO V.a code. The critical experiments available for the validation of the KENO-VI code cover three broad categories of systems. The fissile materials in the systems vary and include high- and intermediate-enrichment uranium and mixed uranium/plutonium oxides. The physical form of the fissile material is either metal or rod arrays in water. As with KENO V.a, both fast and thermal neutron energy spectra are represented in the systems considered. The results indicate generally good performance of both the KENO V.a and KENO-VI codes across the range of systems analyzed. The bias of calculated k eff from expected values is less than 0.9% Δk in all cases. All eight categories of experiments show biases of less than 0.5% Δk in KENO V.a with the exception of intermediate enrichment metal systems using the 238-group library. The continuous energy library generally manifests lower biases than the multigroup data. The KENO-VI results show slightly larger biases, though this may primarily be the result of modeling systems with more geometric complexity, which are more difficult to describe accurately, even with a generalized geometry code like KENO-VI. Several additional conclusions can be drawn from the results of this validation effort. These conclusions include that the TSUNAMI tools can be used successfully to explain the cause of aberrant results, that some evaluations in the IHECSBE should be updated to provide more rigorous expected k eff values and uncertainties, and that potential cross-section errors can be identified by detailed review of the results of this validation. It also appears that the overall cross-section uncertainty as quantified through the SCALE covariance library is overestimated. Overall, the KENO V.a and KENO-VI codes are shown to provide consistent, low-bias results for a wide range of physical systems of potential interest in criticality safety applications.

Marshall, William (BJ) J.↗

Criticality Safety Validation of Scale 6.1

The computational bias of criticality safety computer codes must be established through the validation of the codes to critical experiments. A large collection of suitable experiments has been vetted by the International Criticality Safety Benchmark Experiment Program (ICSBEP) and made available in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (IHECSBE). A total of more than 350 cases from this reference have been prepared and reviewed within the Verified, Archived Library of Inputs and Data (VALID) maintained by the Reactor and Nuclear Systems Division at Oak Ridge National Laboratory. The performance of the KENO V.a and KENO-VI Monte Carlo codes within the Scale 6.1 code system with ENDF/B-VII.0 cross-section data in 238-group and continuous energy is assessed using the VALID models of benchmark experiments. The TSUNAMI tools for sensitivity and uncertainty analysis are utilized to examine some systems further in an attempt to identify potential causes of unexpected results. The critical experiments available for validation of the KENO V.a code cover eight different broad categories of systems. These systems use a range of fissile materials including a range of uranium enrichments, various plutonium isotopic vectors, and mixed uranium-plutonium oxides. The physical form of the fissile material also varies and is represented as metal, solutions, or arrays of rods or plates in a water moderator. The neutron energy spectra of the systems also vary and cover both fast and thermal spectra. Over 300 of the total cases used utilize the KENO V.a code. The critical experiments available for the validation of the KENO-VI code cover three broad categories of systems. The fissile materials in the systems vary and include high and intermediate-enrichment uranium and mixed uranium/plutonium oxides. The physical form of the fissile material is either metal or rod arrays in water. As with KENO V.a, both fast and thermal neutron energy spectra are represented in the systems considered. The results indicate generally good performance of both the KENO V.a and KENO-VI codes across the range of systems analyzed. The bias of calculated k{sub eff} from expected values is less than 0.9% {Delta}k in all cases. All eight categories of experiments show biases of less than 0.5% {Delta}k in KENO V.a with the exception of intermediate enrichment metal systems using the 238-group library. The continuous energy library generally manifests lower biases than the multi-group data. The KENO-VI results show slightly larger biases, though this may primarily be the result of modeling systems with more geometric complexity, which are more difficult to describe accurately, even with a generalized geometry code like KENO-VI. Several additional conclusions can be drawn from the results of this validation effort. These conclusions include that the TSUNAMI tools can be used successfully to explain the cause of aberrant results, that some evaluations in the IHECSBE should be updated to provide more rigorous expected k{sub eff} values and uncertainties, and that potential cross-section errors can be identified by detailed review of the results of this validation. It also appears that the overall cross-section uncertainty as quantified through the Scale covariance library is overestimated. Overall, the KENO V.a and KENO-VI codes are shown to provide consistent, low bias results for a wide range of physical systems of potential interest in criticality safety applications.

Marshall, William BJ J↗

Structural Design Requirements and Factors of Safety for Spaceflight Hardware: For Human Spaceflight

This document establishes the structural requirements for human-rated spaceflight hardware including launch vehicles, spacecraft and payloads. These requirements are applicable to Government Furnished Equipment activities as well as all related contractor, subcontractor and commercial efforts. These requirements are not imposed on systems other than human-rated spacecraft, such as ground test articles, but may be tailored for use in specific cases where it is prudent to do so such as for personnel safety or when assets are at risk. The requirements in this document are focused on design rather than verification. Implementation of the requirements is expected to be described in a Structural Verification Plan (SVP), which should describe the verification of each structural item for the applicable requirements. The SVP may also document unique verifications that meet or exceed these requirements with NASA Technical Authority approval.

Bernstein, Karen S.↗

Corrective Action Decision Document/Corrective Action Plan for Corrective Action Unit 547: Miscellaneous Contaminated Waste Sites, Nevada National Security Site, Nevada, Revision 0

The purpose of this CADD/CAP is to present the corrective action alternatives (CAAs) evaluated for CAU 547, provide justification for selection of the recommended alternative, and describe the plan for implementing the selected alternative. Corrective Action Unit 547 consists of the following three corrective action sites (CASs): (1) CAS 02-37-02, Gas Sampling Assembly; (2) CAS 03-99-19, Gas Sampling Assembly; and(3) CAS 09-99-06, Gas Sampling Assembly. The gas sampling assemblies consist of inactive process piping, equipment, and instrumentation that were left in place after completion of underground safety experiments. The purpose of these safety experiments was to confirm that a nuclear explosion would not occur in the case of an accidental detonation of the high-explosive component of the device. The gas sampling assemblies allowed for the direct sampling of the gases and particulates produced by the safety experiments. Corrective Action Site 02-37-02 is located in Area 2 of the Nevada National Security Site (NNSS) and is associated with the Mullet safety experiment conducted in emplacement borehole U2ag on October 17, 1963. Corrective Action Site 03-99-19 is located in Area 3 of the NNSS and is associated with the Tejon safety experiment conducted in emplacement borehole U3cg on May 17, 1963. Corrective Action Site 09-99-06 is located in Area 9 of the NNSS and is associated with the Player safety experiment conducted in emplacement borehole U9cc on August 27, 1964. The CAU 547 CASs were investigated in accordance with the data quality objectives (DQOs) developed by representatives of the Nevada Division of Environmental Protection (NDEP) and the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office. The DQO process was used to identify and define the type, amount, and quality of data needed to determine and implement appropriate corrective actions for CAU 547. Existing radiological survey data and historical knowledge of the CASs were sufficient to meet the DQOs and evaluate CAAs without additional investigation. As a result, further investigation of the CAU 547 CASs was not required. The following CAAs were identified for the gas sampling assemblies: (1) clean closure, (2) closure in place, (3) modified closure in place, (4) no further action (with administrative controls), and (5) no further action. Based on the CAAs evaluation, the recommended corrective action for the three CASs in CAU 547 is closure in place. This corrective action will involve construction of a soil cover on top of the gas sampling assembly components and establishment of use restrictions at each site. The closure in place alternative was selected as the best and most appropriate corrective action for the CASs at CAU 547 based on the following factors: (1) Provides long-term protection of human health and the environment; (2) Minimizes short-term risk to site workers in implementing corrective action; (3) Is easily implemented using existing technology; (4) Complies with regulatory requirements; (5) Fulfills FFACO requirements for site closure; (6) Does not generate transuranic waste requiring offsite disposal; (7) Is consistent with anticipated future land use of the areas (i.e., testing and support activities); and (8) Is consistent with other NNSS site closures where contamination was left in place.

54 ENVIRONMENTAL SCIENCES↗

Searching for a Pulse: Evaluating the Use of Rapid DC Pulses for Diagnosing Battery Health, State-of-Charge, and Safety

Rapid electrochemical diagnostics, like DC pulse sequences or electrochemical impedance spectroscopy, are known to be useful for capacity prediction. However, it is unclear how previous results will map to different cell types and use cases and whether rapid diagnostics are useful for remaining useful life prediction or for detecting potential safety issues. To that end, we have collected a data set with ∼50,000 DC pulse measurements from four types of commercial lithium-ion batteries to enable training of state-of-charge, health, and safety diagnostic models via machine-learning. We demonstrate that 120-second DC pulse sequences can be used to predict capacity with 2%–9% average error, which can separate high- from low-capacity cells with only a 0.3% false positive rate but is not accurate enough to estimate remaining useful life. We also find that no safety related targets can be accurately predicted, highlighting the critical need for other non-invasive methods to diagnose battery safety.

25 ENERGY STORAGE↗

Successful delivery of adjuvant external beam radiotherapy for ependymoma in a patient with Ondine's curse

Ondine's curse is a rare, potentially life-threatening disorder characterized by loss of automatic breathing during sleep and preserved voluntary breathing. It is seldom encountered in the radiotherapy clinic but can pose significant technical challenges and safety concerns in the delivery of a prescribed radiation course. We report a unique case of successful delivery of radiotherapy for ependymoma in a patient with Ondine's curse. A 53-year-old gentleman presented with vertigo when lying down. Brain magnetic resonance imaging revealed an enhancing mass in the floor of the fourth ventricle. He underwent maximal safe resection. Pathology revealed ependymoma. The patient was referred for radiotherapy. Computed tomography simulation was performed in supine position with 3-point thermoplastic mask immobilization. Sequential TomoTherapy plans were developed. At first scheduled treatment, shortly after mask placement, his arms went limp and he was unresponsive. Vitals showed oxygen saturation 83%, pulse 127, and blood pressure 172/97 mm Hg. He was diagnosed with Ondine's curse thought secondary to previous brainstem damage; the combination of lying flat and pressure from the mask was causing him to go into respiratory arrest. As supine positioning did not seem clinically advisable, he was simulated in prone position. A RapidArc plan and a back-up conformal plan were developed. Prescriptions were modified to meet conservative organs-at-risk constraints. Several strategies were used to minimize uncertainties in set-up reproducibility associated with prone positioning. He tolerated prone RapidArc treatments well. The report highlights the importance of applying practical patient safety and treatment planning/delivery strategies in the management of this challenging case.

61 RADIATION PROTECTION AND DOSIMETRY↗

AP1000{sup R} nuclear power plant safety overview for spent fuel cooling

The AP1000{sup R} plant is an 1100-MWe class pressurized water reactor with passive safety features and extensive plant simplifications that enhance construction, operation, maintenance, safety and costs. The AP1000 design uses passive features to mitigate design basis accidents. The passive safety systems are designed to function without safety-grade support systems such as AC power, component cooling water, service water or HVAC. Furthermore, these passive features 'fail safe' during a non-LOCA event such that DC power and instrumentation are not required. The AP1000 also has simple, active, defense-in-depth systems to support normal plant operations. These active systems provide the first level of defense against more probable events and they provide investment protection, reduce the demands on the passive features and support the probabilistic risk assessment. The AP1000 passive safety approach allows the plant to achieve and maintain safe shutdown in case of an accident for 72 hours without operator action, meeting the expectations provided in the U.S. Utility Requirement Document and the European Utility Requirements for passive plants. Limited operator actions are required to maintain safe conditions in the spent fuel pool via passive means. In line with the AP1000 approach to safety described above, the AP1000 plant design features multiple, diverse lines of defense to ensure spent fuel cooling can be maintained for design-basis events and beyond design-basis accidents. During normal and abnormal conditions, defense-in-depth and other systems provide highly reliable spent fuel pool cooling. They rely on off-site AC power or the on-site standby diesel generators. For unlikely design basis events with an extended loss of AC power (i.e., station blackout) or loss of heat sink or both, spent fuel cooling can still be provided indefinitely: - Passive systems, requiring minimal or no operator actions, are sufficient for at least 72 hours under all possible pool heat load conditions. - After 3 days, several different means are provided to continue spent fuel cooling using installed plant equipment as well as off-site equipment with built-in connections. Even for beyond design basis accidents with postulated pool damage and multiple failures in the passive safety-related systems and in the defense-in-depth active systems, the AP1000 multiple spent fuel pool spray and fill systems provide additional lines of defense to prevent spent fuel damage. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗