Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SYMPTOMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

A Novel Carotid Device for Embolic Diversion: Lessons Learned from a 'First in Man' Trial in Patients with Atrial Fibrillation

Purpose: This study was designed to investigate a novel device that was developed to direct emboli away from the internal carotid artery to the external carotid artery to prevent embolic stroke while avoiding the necessity for anticoagulation with warfarin. Methods: A stent-like, self-expandable filter was developed consisting of fine cobalt alloy mesh. After promising preclinical animal testing, the device was implanted into the common carotid artery extending into the external carotid artery in three patients with atrial fibrillation, each of whom were at high-risk for cerebral emboli and were suboptimal candidates for anticoagulation. Follow-up was performed clinically and with carotid duplex ultrasound. Results: The implantation was successful in all three patients. Unrestricted flow through the filter was demonstrated in each patient at 6 months by duplex sonography. However, at 7 months ultrasound demonstrated occlusion of the internal carotid artery filter in one patient, which was subsequently confirmed by angiography. Subtotal filter occlusion occurred in a second patient at 14 months. Neither patient had clinical symptoms. Both internal carotid arteries were successfully recanalized using standard angioplasty techniques without complication. The third patient had completely normal carotid blood flow at 29 months follow-up. Conclusions: Implantation of a novel device intended to divert emboli away from the internal carotid artery was feasible, but resulted in occlusive neointimal proliferation in two of three patients. These results demonstrate a discrepancy from the findings of preclinical animal studies and human investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Uteroenteric Fistula Resulting From Fibroid Expulsion After Uterine Fibroid Embolization: Case Report and Review of the Literature

A 44-year-old woman underwent uncomplicated uterine fibroid embolization (UFE) for menstrual and bulk-related symptoms in an enlarged, myomatous uterus. After surgery, she spontaneously sloughed a large mass of fibroids that arrested in the cervical canal during passage. Four days after gynecological extraction, she developed copious vaginal discharge that contained enteric contents. Contrast-enhanced computed tomography (CT) demonstrated a fistula between the small bowel and the uterus. She subsequently underwent hysterectomy, left oophorectomy, and small-bowel resection. Her postoperative recovery was uneventful.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fracture and Collapse of Balloon-Expandable Stents in the Bilateral Common Iliac Arteries Due to Shiatsu Massage

We report a case of stent fracture and collapse of balloon-expandable stents caused by shiatsu massage. A 76-year-old man presented with complaints of intermittent claudication of the right lower extremity. Stenoses of the bilateral common iliac arteries (CIAs) were detected. Balloon-expandable stents were deployed in both CIAs, resulting in resolution of symptoms. Five months later, pelvis x-ray showed collapse of both stents. Despite the stent collapse, the patient was asymptomatic, and his ankle brachial index values were within the normal range. Further history showed that the patient underwent daily shiatsu therapy in the umbilical region, which may have triggered collapse of the stent. Physicians should advise patients to avoid compression of the abdominal wall after implantation of a stent in the iliac artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanical Recanalization of Subacute Vessel Occlusion in Peripheral Arterial Disease with a Directional Atherectomy Catheter

Purpose: To retrospectively examine the technical feasibility and safety of directional atherectomy for treatment of subacute infrainguinal arterial vessel occlusions. Methods: Five patients (one woman, four men, age range 51-81 years) with peripheral arterial disease who experienced sudden worsening of their peripheral arterial disease-related symptoms during the last 2-6 weeks underwent digital subtraction angiography, which revealed vessel occlusion in native popliteal artery (n = 4) and in-stent occlusion of the superficial femoral artery (n = 1). Subsequently, all patients were treated by atherectomy with the SilverHawk (ev3 Endovascular, USA) device. Results: The mean diameter of treated vessels was 5.1 {+-} 1.0 mm. The length of the occlusion ranged 2-14 cm. The primary technical success rate was 100%. One patient experienced a reocclusion during hospitalization due to heparin-induced thrombocytopenia. There were no further periprocedural complications, in particular no peripheral embolizations, until hospital discharge or during the follow-up period of 1 year. Conclusion: The recanalization of infrainguinal arterial vessel occlusions by atherectomy with the SilverHawk device is technically feasible and safe. In our limited retrospective study, it was associated with a high technical success rate and a low procedure-related complication rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MR-Guided Focused Ultrasound for the Treatment of Uterine Fibroids

Magnetic resonance imaging-guided focused ultrasound (MRgFUS) ablation of uterine fibroids provides a minimally invasive outpatient technique for targeting and treating symptomatic uterine fibroids. Magnetic resonance imaging provides a guidance platform that has high temporal and spatial resolution for guiding, as well as thermal monitoring of the procedure. The high-intensity focused ultrasound provides a mechanism for delivering large amounts of energy directly into the fibroid without causing detrimental effects to the nontarget tissues. Early and intermediate follow-up of patients treated with MRgFUS provided promising results on the efficacy of the technique for providing symptom relief to patients. As more long-term follow-up data are published, the efficacy of this technique can be compared to more invasive surgical and minimally invasive catheter treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Primary Infrarenal Aortic Stenting With or Without Iliac Stenting for Isolated and Aortoiliac Stenoses: Single-Centre Experience With Long-Term Follow-Up

The purpose of this study was to evaluate the technical success, complications, long-term clinical outcome, and patency after primary infrarenal aortic stenting for aortic and aortoiliac stenosis. Between January 1999 and January 2006, 22 consecutive patients underwent endovascular treatment because of infrarenal aortic stenosis with and without common iliac stenosis (10 men; mean age 64 {+-} 14 years). Eleven (11 of 22) patients had an isolated aortic stenosis, whereas 11 of 22 had aortic stenosis that extended into the common iliac arteries (CIAs). Thirteen patients were Rutherford classification type 3, and 9 patients were type 4. Statistical analysis included paired Student t test and Kaplan-Meier life table analysis; p < 0.05 was considered significant. Technical and initial clinical success was achieved in all patients. There were three (14 %) procedure-related complications, which included two access-point pseudoaneurysms and one non-flow-limiting left external iliac dissection. Patients were followed-up for a mean period of 88 months (range 60-132). Mean preprocedure ankle brachial pressure indexes (ABPI) were 0.60 {+-} -0.15 (right) and 0.61 {+-} -0.16 (left). After the procedure they were 0.86 {+-} -0.07 (right) and 0.90 {+-} -0.09 (left). The increase in ABPI was significant (p < 0.05), and this continued throughout follow-up. Four (18 %) patients had recurrence of symptoms during follow-up. These occurred at 36, 48, 48, and 50 months after the original procedure. All four patients were successfully treated with repeat angioplasty procedures. There was a significant difference in primary patency between isolated aortic stenosis (100 %) and aortoiliac stenosis (60 %) (p = 0.031). Cumulative follow-up was 1920 months yielding a reintervention rate of 0.025/events/year. Primary stenting of infrarenal stenosis is safe and successful with a low reintervention rate. It should be considered as first-line treatment for patients with infrarenal aortic stenotic disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Management of Postoperative Lymphoceles After Lymphadenectomy: Percutaneous Catheter Drainage With and Without Povidone-Iodine Sclerotherapy

To report our single-center experience in managing symptomatic lymphoceles after lymphadenectomy for genitourinary and gynecologic malignancy and to compare clinical outcomes of percutaneous catheter drainage (PCD) alone versus PCD with transcatheter povidone-iodine sclerotherapy (TPIS). The medical records of patients who presented for percutaneous drainage of pelvic lymphoceles from February 1999 to September 2007 were retrospectively reviewed. Catheters with prolonged outputs >50 cc/day were treated with TPIS. Technical success was defined as the ability to achieve complete resolution of the lymphocele. Clinical success was defined as resolution of the patient's symptoms that prompted the intervention. Sixty-four patients with 70 pelvic lymphoceles were treated. Forty-six patients (71.9 %) had PCD, and 18 patients (28.1 %) had multisession TPIS. The mean initial cavity size was 294.9 cc for those treated with TPIS and 228.2 cc for those treated with PCD alone (range 15-1,600) (p = 0.59). Mean duration of catheter drainage was 19 days (29 days with TPIS, 16 days with PCD, p = 0.001). Mean clinical follow-up was 22.6 months. Technical success was 74.3 % with PCD and 100 % with TPIS. Clinical success was 97 % with PCD and 100 % with TPIS. Postprocedural complications included pericatheter fluid leakage (n = 4), catheter dislodgement (n = 3), catheter occlusion (n = 9), and secondary infection of the collection (n = 4). PCD of symptomatic lymphoceles is an effective postoperative management technique. Initial cavity size is not an accurate predictor of the need for TPIS. When indicated, TPIS is safe and effective with catheter outputs >50 cc/day.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extrahepatic Pseudoaneurysms and Ruptures of the Hepatic Artery in Liver Transplant Recipients: Endovascular Management and a New Iatrogenic Etiology

To characterize extrahepatic pseudoaneurysm regarding incidence and etiology and determine the effectiveness of endovascular management. A retrospective audit of 1,857 liver transplants in two institutions was performed (1996-2009). Recipients' demographics, clinical presentation, transplant type, biliary anastomosis, and presence of biliary endoprostheses were noted. Pseudoaneurysms were classified into iatrogenic (associated with biliary endoprosthesis or angioplasty) or spontaneous extrahepatic pseudoaneurysms. Spontaneous and iatrogenic pseudoaneurysms were compared for time from transplant, presenting symptoms, location in the arterial anatomy, and 3-month graft survival. Arterial patency and 6-month graft survival were calculated. Twenty pseudoaneurysms were found (1.1 %, 20/1,857): 9 (0.5 % of transplants, 9/1,857) were spontaneous and 11 (0.6 % of transplants, 11/1,857) were 'iatrogenic' (due to minimally invasive procedures: 4 angioplasty and 7 biliary endoprostheses). Sixty percent (12/20) underwent endovascular management (4 coil embolization and 8 stent-grafts). Technical success was 83 % (10/12) with a mean arterial patency of 70 % (follow-up mean, 4.9; range, 0-18 months). The 1-, 3-, and 6-month graft survival was 70, 40, and 35 %, respectively. Due to minimally invasive procedures, posttransplant extrahepatic pseudoaneurysms are no longer an exclusive complication of the transplant surgery itself. Endovascular management is effective to stabilize patients but has not improved historic postsurgical graft survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MINI PCNL in a Pediatric Population

We report our initial experience of MINI percutaneous nephrolithotomy (PCNL) in a pediatric population using a miniature nephroscope through a 16F metal access sheath. All pediatric patients who underwent PCNL from August 2007 to September 2010 using a 14F miniature nephroscope through a 16F metal access sheath for renal stone extraction were evaluated. Patients' demographic details, procedural information, and posttreatment outcomes were prospectively documented. A total of 23 MINI PCNLs were performed on 23 kidneys of 12 patients whose ages ranged from 1.6 to 14.6 years. The median stone burden was 3.44 cm{sup 2}, and there were 11 'Staghorn' stones. The procedure was primary via a single puncture in 19 kidneys and secondary using a preexisting nephrostomy tract in 4 kidneys. Access was successful in all primary and two secondary cases, for a total of success rate of 91.3%. Stones were fragmented using a Holmium laser and/or lithoclast, and fragments were irrigated or sequentially removed by various stone grasping devices. The mean procedural X-ray screening time and total stone extraction period were 4.5 and 109.4 min, respectively. The primary stone free rate was 83.6 %, which increased to 90.5 % after treating the residual fragments. Postoperative hydrothorax developed in one patient, which required a chest drain. Symptoms of chest infection and positive urine culture were detected in one and two patients, respectively. Our initial experience supports previous reports that MINI PCNL is safe and effective for the management of renal stones in children.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Treatment of Iatrogenic Pseudoaneurysms by Cyanoacrylate-Based Wall-Gluing

Purpose. Although the majority of iatrogenic pseudoaneurysms (PSAs) are amenable to ultrasound (US)-guided thrombin injection, patients with those causing neuropathy, claudication, significant venous compression, or soft tissue necrosis are considered poor candidates for this option and referred to surgery. We aimed to test the effectiveness and feasibility of a novel percutaneous cyanoacrylate glue (NBCA-MS)-based technique for treatment of symptomatic and asymptomatic iatrogenic PSA. Material and Methods. During a 3-year period, we prospectively enrolled 91 patients with iatrogenic PSA [total n = 94 (femoral n = 76; brachial n = 11; radial n = 6; axillary n = 1)]. PSA were asymptomatic in 66 % of cases, and 34 % presented with symptoms due to neuropathy, venous compression, and/or soft tissue necrosis. All patients signed informed consent. All patients received NBCA-MS-based percutaneous treatment. PSA chamber emptying was first obtained by US-guided compression; superior and inferior walls of the PSA chamber were then stuck together using NBCA-MS microinjections. Successfulness of the procedure was assessed immediately and at 1-day and 1-, 3-, and 12-month US follow-up. Results. PSA occlusion rate was 99 % (93 of 94 cases). After treatment, mean PSA antero-posterior diameter decrease was 67 {+-} 22 %. Neuropathy and vein compression immediately disappeared in 91 % (29 of 32) of cases. Patients with tissue necrosis (n = 6) underwent subsequent outpatient necrosectomy. No distal embolization occurred, nor was conversion to surgery necessary. Conclusion. PSA treatment by way of NBCA-MS glue injection proved to be safe and effective in asymptomatic patients as well as those with neuropathy, venous compression, or soft-tissue necrosis (currently candidates for surgery). Larger series are needed to confirm these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ureteric Embolization for Lower Urinary Tract Fistulae: Use of Two Amplatzer Vascular Plugs and N-Butyl Cyanoacrylate Employing the 'Sandwich' Technique

PurposeThis study describes and evaluated the effectiveness of occluding distal ureters in the clinical setting of urinary vaginal (vesicovaginal or enterovesicovaginal) fistulae utilizing a new technique which combines Amplatzer vascular plugs and N-butyl cyanoacrylate.MaterialsThis is a retrospective study (January 2007-December 2010) of patients with urinary-vaginal fistulae undergoing distal ureter embolization utilizing an Amplatzer- N-butyl cyanoacrylate-Amplatzer sandwich technique. An 8-12-mm type-I or type-II Amplatzer vascular plug was delivered using the sheath and deployed in the ureter distal to the pelvic brim. Instillation of 0.8-1.5 cc of N-butyl cyanoacrylate into ureter proximal to the Amplatzer plug was performed. This was followed by another set of 8-12-mm type-I or type-II Amplatzer vascular plugs in a technique referred to as the 'sandwich technique.'ResultsFive ureters in three patients were occluded utilizing the above-described technique during the 4-year study period. Mean maximum size Amplatzer used per ureter was 10.8 mm (range, 8-12). One ureter required three Amplatzer plugs and the rest required two. Two patients (3 ureters) were clinically successful with complete resolution of symptoms in 36-48 h. The third patient (2 ureters) was partly successful and required a second Amplatzer- N-butyl cyanoacrylate sandwich technique embolization. The mean clinical follow-up was 11.3 months (range, 1.7-29.2).ConclusionsThe Amplatzer- N-butyl cyanoacrylate-Amplatzer sandwich technique for occluding the distal ureter is safe and effective with a quick (probably due to the N-butyl cyanoacrylate) and durable (probably due to the Amplatzer plugs) clinical response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined Pharmacomechanical Thrombolysis of Complete Portomesenteric Thrombosis in a Liver Transplant Recipient

Treatment options for portomesenteric venous thrombosis range from anticoagulation to surgery, depending on chronicity, severity of symptoms, extent of thrombosis, and the availability of local expertise. For acute and subacute cases, a variety of endovascular options have been described in limited published series and case reports, including thrombolysis and mechanical thrombectomy. We report what is to our knowledge the first case in which the Trellis pharmacomechanical thrombolysis device was used successfully to treat complete acute thrombosis of the entire superior mesenteric vein and the entire portal vein with extension into all segmental intrahepatic portal branches in a young adult after liver transplantation. This device, coupled with adjunctive techniques using balloon catheters, facilitated complete restoration of flow, resulting in graft salvage and long-term patency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role of Interventional Radiology in the Management of Chylothorax: A Review of the Current Management of High Output Chylothorax

Chylothorax is an uncommon type of pleural effusion whose etiology may be classified as traumatic or nontraumatic. Low-output chylothoraces usually respond well to conservative management, whereas high-output chylothoraces are more likely to require surgical or interventional treatment. Conservative management focuses on alleviation of symptoms, replacement of fluid and nutrient losses, and reduction of chyle output to facilitate spontaneous healing. Surgical management can be technically difficult due to the high incidence of variant anatomy and the high-risk patient population. Percutaneous treatments have rapidly developed and evolved during the past 14 years to represent a minimally invasive treatment compared with the more invasive nature of surgery. Percutaneous therapies provide a range of treatment options despite difficult or variant anatomy, with a reported high success rate coupled with low morbidity and mortality. This article is a review of etiology, diagnosis, and treatment of chylothorax, with a focus on interventional management techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical, Laboratorial, and Urodynamic Findings of Prostatic Artery Embolization for the Treatment of Urinary Retention Related to Benign Prostatic Hyperplasia. A Prospective Single-Center Pilot Study

PurposeThis study was designed to describe the clinical, laboratorial, and urodynamic findings of prostatic artery embolization (PAE) in patients with urinary retention due to benign prostatic hyperplasia (BPH).MethodsA prospective study of 11 patients with urinary retention due to BPH was conducted. Patients underwent physical examination, prostate specific antigen (PSA) measurement, transrectal ultrasound, and magnetic resonance imaging. International prostate symptom score (IPSS), quality of life (QoL), and urodynamic testing were used to assess the outcome before and after 1 year.ResultsClinical success was 91 % (10/11 patients) with a mean follow-up of 22.3 months (range, 12-41 months). At the first year follow-up, the mean IPSS score was 2.8 points (p = 0.04), mean QoL was 0.4 points (p = 0.001), mean PSA decreased from 10.1 to 4.3 ng/mL (p = 0.003), maximum urinary flow (Qmax) improved from 4.2 to 10.8 mL/sec (p = 0.009), and detrusor pressure (Pdet) decreased from 85.7 to 51.5 cm H{sub 2}O (p = 0.007). Before PAE, Bladder Outlet Obstruction Index (BOOI) showed values >40 in 100 % of patients. After PAE, 30 % of patients were >40 (obstructed), 40 % were between 20 and 40 (undetermined), and 30 % were <20 (unobstructed). Patients with a BOOI <20 had higher PSA values at 1-day after PAE.ConclusionsClinical and urodynamic parameters improved significantly after PAE in patients with acute urinary retention due to BPH. Total PSA at day 1 after PAE was higher in patients with unobstructed values in pressure flow studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transient Ischemic Rectitis as a Potential Complication after Prostatic Artery Embolization: Case Report and Review of the Literature

Prostatic artery embolization (PAE) is an alternative treatment for benign prostatic hyperplasia. Complications are primarily related to non-target embolization. We report a case of ischemic rectitis in a 76-year-old man with significant lower urinary tract symptoms due to benign prostatic hyperplasia, probably related to nontarget embolization. Magnetic resonance imaging revealed an 85.5-g prostate and urodynamic studies confirmed Inferior vesical obstruction. PAE was performed bilaterally. During the first 3 days of follow-up, a small amount of blood mixed in the stool was observed. Colonoscopy identified rectal ulcers at day 4, which had then disappeared by day 16 post PAE without treatment. PAE is a safe, effective procedure with a low complication rate, but interventionalists should be aware of the risk of rectal nontarget embolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Newly Designed Stent for Management of Malignant Distal Duodenal Stenosis

PurposeTo evaluate the clinical effectiveness of a newly designed stent for the treatment of malignant distal duodenal stenosis.MethodsFrom March 2011 to May 2013, six patients with malignant duodenal stenosis underwent fluoroscopically guided placement of the new duodenal stent consisting of braided, nested stent wires, and a delivery system with a metallic mesh inner layer. Primary diseases were pancreatic cancer in three patients, gastric cancer in two patients, and endometrial stromal sarcoma in one patient. Duodenal obstructions were located in the horizontal part in two patients, the ascending part in two patients, and the duodenojejunal flexure in two patients. Technical success, defined as the successful stent deployment, clinical symptoms before and after the procedure, and complications were evaluated.ResultsTechnical success was achieved in all patients. No major complications were observed. Before treatment, two patients could not take any food and the gastric outlet obstruction scoring system (GOOSS) score was 0; the other four patients could take only liquids orally (GOOSS score = 1). After treatment, five patients could take soft food (GOOSS score = 2) and one patient could take a full diet (GOOSS score = 3). The mean duration of primary stent patency was 115.7 days.ConclusionsThe newly designed stent is associated with a high degree of technical success and good clinical outcome and may be clinically effective in the management of malignant distal duodenal obstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Late Complication after Superficial Femoral Artery (SFA) Aneurysm: Stent-graft Expulsion Outside the Skin

A 78-year-old man presented with a 7-cm aneurysm in the left superficial femoral artery, which was considered unfit and anatomically unsuitable for conventional open surgery for multiple comorbidities. The patient was treated with stent-graft [Viabhan stent-graft (WL Gore and Associates, Flagstaff, AZ)]. Two years from stent-graft implantation, the patient presented a purulent secretion and a spontaneous external expulsion through a fistulous channel. No claudication symptoms or hemorrhagic signs were present. The pus and device cultures were positive for Staphylococcus aureus sensitive to piperacillin/tazobactam. Patient management consisted of fistula drainage, systemic antibiotic therapy, and daily wound dressing. At 1-month follow-up, the wound was closed. To our knowledge, this is the first case of this type of stent-graft complication presenting with external expulsion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Sclerotherapy of Congenital Slow-Flow Vascular Malformations of the Orbit

PurposeThis manuscript describes the clinical features, imaging findings, treatment details, and short-term outcomes of a series of congenital slow-flow vascular malformations.MethodsThis was a prospective study of congenital slow-flow vascular malformations involving the orbital region treated at a single institution with percutaneous sclerotherapy.ResultsTen patients presented during the study period, comprising eight venous malformations, one lymphatic malformation, and one veno-lymphatic malformation. Nine patients underwent percutaneous sclerotherapy under digital subtraction angiography guidance, of which three developed marked rise in intraocular pressure requiring lateral canthotomy. The treatments were performed in the presence of an ophthalmologist who measured the intraorbital pressure during and after the procedure. On follow-up, some of the patients required repeat sessions of sclerotherapy. All patients had improvement of symptoms on follow up after the procedure.ConclusionCongenital slow-flow vascular malformations of the orbital region are rare lesions that should be treated using a multidisciplinary approach. Monitoring of the intraorbital pressure is required both during and after the procedure to decide about the need for lateral canthotomy to reduce the transiently increased intraorbital pressure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗