Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Deep Cryogenic Low Power 24 Bits Analog to Digital Converter with Active Reverse Cryostat

LBNL is developing an innovative data acquisition module for superconductive magnets where the front-end electronics and digitizer resides inside the cryostat. This electronic package allows conventional electronic technologies such as enhanced metal–oxide–semiconductor to work inside cryostats at temperatures as low as 4.2 K. This is achieved by careful management of heat inside the module that keeps the electronic envelop at approximately 85 K. This approach avoids all the difficulties that arise from changes in carrier mobility that occur in semiconductors at deep cryogenic temperatures. There are several advantages in utilizing this system. A significant reduction in electrical noise from signals captured inside the cryostat occurs due to the low temperature that the electronics is immersed in, reducing the thermal noise. The shorter distance that signals are transmitted before digitalization reduces pickup and cross-talk between channels. This improved performance in signal-to-noise rate by itself is a significant advantage. Another important advantage is the simplification of the feedthrough interface on the cryostat head. Data coming out of the cryostat is digital and serial, dramatically reducing the number of lines going through the cryostat feedthrough interface. It is important to notice that all lines coming out of the cryostat are digital and low voltage, reducing the possibility of electric breakdown inside the cryostat. This paper will explain in details the architecture and inner workings of this data acquisition system. It will also provide the performance of the analog to digital converter when the system is immersed in liquid helium, and in liquid nitrogen. Parameters such as power dissipation, integral non-linearity, effective number of bits, signal-to-noise and distortion, will be presented for both temperatures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Receiver array for high-rate telemetry

RF carrier uses two receiver systems to increase signal-to-noise ratio and sensitivity. Signals separately processed are coherently combined at summing junction for improved reception of marginal high-rate signals frequently lost to system, atmosphere, and galactic noises. Two receivers improve ratio by 2.7 dB; improvement is made by arraying more receiver systems.

Brockman, M. H.↗

An ultra-thin diamond membrane as a transmission particle detector and vacuum window for external microbeams

Several applications of external microbeam techniques demand a very accurate and controlled dose delivery. To satisfy these requirements when post-sample ion detection is not feasible, we constructed a transmission single-ion detector based on an ultra-thin diamond membrane. The negligible intrinsic noise provides an excellent signal-to-noise ratio and enables a hit-detection efficiency of close to 100%, even for energetic protons, while the small thickness of the membrane limits beam spreading. Moreover, because of the superb mechanical stiffness of diamond, this membrane can simultaneously serve as a vacuum window and allow the extraction of an ion microbeam into the atmosphere.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Capacity of noncoherent MFSK channels

Performance limits theoretically achievable over noncoherent channels perturbed by additive Gaussian noise in hard decision, optimal, and soft decision receivers are computed as functions of the number of orthogonal signals and the predetection signal-to-noise ratio. Equations are derived for orthogonal signal capacity, the ultimate MFSK capacity, and the convolutional coding and decoding limit. It is shown that performance improves as the signal-to-noise ratio increases, provided the bandwidth can be increased, that the optimum number of signals is not infinite (except for the optimal receiver), and that the optimum number decreases as the signal-to-noise ratio decreases, but is never less than 7 for even the hard decision receiver.

Bar-David, I.↗

NASA/LMSC instrument design and fabrication

The topics addressed are: (1) class-10 flight test program; (2) class system requirements; (3) Doppler wind velocity measurement; (4) systems specifications rational; (5) signal-to-noise equation for remote atmospheric sensing laser velocimeter; (6) variation of signal-to-noise ratios and true wind velocity with distance; (7) velocity error as a function of signal-to-noise ratio, with turbulence; and (8) final class optomechanical design on NASA B/737.

Targ, Russel↗

External-field-free magnetic biosensor

In this paper, we report a magnetic nanoparticle (MNP) detection scheme without the presence of any external magnetic field. The proposed magnetic sensor uses a patterned groove structure within the sensor so that no external magnetic field is needed to magnetize the MNPs. An example is given based on a giant magnetoresistance (GMR) sensing device with a spin valve structure. For this structure, the detection of MNPs located inside the groove and near the free layer is demonstrated under no external magnetic field. Micromagnetic simulations are performed to calculate the signal to noise level of this detection scheme. A maximum signal to noise ratio (SNR) of 18.6 dB from one iron oxide magnetic nanoparticle with 8 nm radius is achieved. As proof of concept, this external-field-free GMR sensor with groove structure of 200 nm × 200 nm is fabricated using a photo and an electron beam integrated lithography process. Using this sensor, the feasibility demonstration of the detection SNR of 9.3 dB is achieved for 30 μl magnetic nanoparticles suspension (30 nm iron oxide particles, 1 mg/ml). This proposed external-field-free sensor structure is not limited to GMR devices and could be applicable to other magnetic biosensing devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

FORTÉ Machine Learning

Of the non-corrupted data collected by the Orbiting Experiment (forté) satellite’s Photo-Diode Detector during the year 2001, I estimate that 7.9% of 914 894 signals are noise. My result differs dramatically from Guillen’s estimate of 96%. To arrive at this estimate, I used Gaussian mixture model (GMM) clustering–unsupervised machine learning–to aggregate the wave forms into groups based on the absolute value of the lowest 25 positive frequency discrete Fourier transform coefficients. Then, I marked several of the groups as noise by inspecting a random sampling of wave forms from each group. Marking groups as either noise or non-noise is a supervised binary classification operation. After removing the signals in noise groups from further consideration, I clustered the remaining signals into families. Again, I used a GMM, but for the familial clustering I used a Non-Negative Matrix Factorization feature vector transform. The result was 9 distinct families of lightning signals, as well as a second stage of noise filtering. To efficiently represent the entirety of the signal space, I broke each family into deciles based on their distance from the family mean. In this case, distance means the log-likelihood based on the GMM. Signals in lower deciles are more similar in shape and amplitude to their family average. I took the top 200 samples from each decile of each group, resulting in 18 000 signals. These signal approximately represent the entirety of the forté observations. To represent outliers, I also kept a zoo of the 1000 signals furthest from any family’s average. All told, the resulting data set represents the forté data with a reduction of about 51:1. To allow synthesis of an arbitrarily large number of test signals, I also captured each family’s average signal and the time-sample covariance matrix over the signals in each family. Using these two pieces of information, I can synthesize new waveforms by using a Gaussian random realization from the family average and covariance matrix. I wrote a program to test the synthesis quality. The program shows me two signals on the screen, one synthesized and one randomly drawn from the data. I attempted to identify the synthesized signal. Although the synthesis is imperfect, in an A/B comparison I only correctly chose the synthesized signal 36% of the time.

97 MATHEMATICS AND COMPUTING↗

Identifying isotropic events using a regional moment tensor inversion

We calculate the deviatoric and isotropic source components for 17 explosions at the Nevada Test Site, as well as 12 earthquakes and 3 collapses in the surrounding region of the western United States, using a regional time domain full waveform inversion for the complete moment tensor. The events separate into specific populations according to their deviation from a pure double-couple and ratio of isotropic to deviatoric energy. The separation allows for anomalous event identification and discrimination between explosions, earthquakes, and collapses. Confidence regions of the model parameters are estimated from the data misfit by assuming normally distributed parameter values. We investigate the sensitivity of the resolved parameters of an explosion to imperfect Earth models, inaccurate event depths, and data with low signal-to-noise ratio (SNR) assuming a reasonable azimuthal distribution of stations. In the band of interest (0.02–0.10 Hz) the source-type calculated from complete moment tensor inversion is insensitive to velocity model perturbations that cause less than a half-cycle shift (<5 s) in arrival time error if shifting of the waveforms is allowed. The explosion source-type is insensitive to an incorrect depth assumption (for a true depth of 1 km), and the goodness of fit of the inversion result cannot be used to resolve the true depth of the explosion. Noise degrades the explosive character of the result, and a good fit and accurate result are obtained when the signal-to-noise ratio is greater than 5. We assess the depth and frequency dependence upon the resolved explosive moment. As the depth decreases from 1 km to 200 m, the isotropic moment is no longer accurately resolved and is in error between 50 and 200%. Furthermore, even at the most shallow depth the resultant moment tensor is dominated by the explosive component when the data have a good SNR.

58 GEOSCIENCES↗

Imaging of moving fiducial markers during radiotherapy using a fast, efficient active pixel sensor based EPID

Purpose: The purpose of this work was to investigate the use of an experimental complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) for tracking of moving fiducial markers during radiotherapy. Methods: The APS has an active area of 5.4 x 5.4 cm and maximum full frame read-out rate of 20 frame s{sup -1}, with the option to read out a region-of-interest (ROI) at an increased rate. It was coupled to a 4 mm thick ZnWO4 scintillator which provided a quantum efficiency (QE) of 8% for a 6 MV x-ray treatment beam. The APS was compared with a standard iViewGT flat panel amorphous Silicon (a-Si) electronic portal imaging device (EPID), with a QE of 0.34% and a frame-rate of 2.5 frame s{sup -1}. To investigate the ability of the two systems to image markers, four gold cylinders of length 8 mm and diameter 0.8, 1.2, 1.6, and 2 mm were placed on a motion-platform. Images of the stationary markers were acquired using the APS at a frame-rate of 20 frame s{sup -1}, and a dose-rate of 143 MU min{sup -1} to avoid saturation. EPID images were acquired at the maximum frame-rate of 2.5 frame s{sup -1}, and a reduced dose-rate of 19 MU min{sup -1} to provide a similar dose per frame to the APS. Signal-to-noise ratio (SNR) of the background signal and contrast-to-noise ratio (CNR) of the marker signal relative to the background were evaluated for both imagers at doses of 0.125 to 2 MU. Results: Image quality and marker visibility was found to be greater in the APS with SNR {approx}5 times greater than in the EPID and CNR up to an order of magnitude greater for all four markers. To investigate the ability to image and track moving markers the motion-platform was moved to simulate a breathing cycle with period 6 s, amplitude 20 mm and maximum speed 13.2 mm s{sup -1}. At the minimum integration time of 50 ms a tracking algorithm applied to the APS data found all four markers with a success rate of {>=}92% and positional error {<=}90 {mu}m. At an integration time of 400 ms the smallest marker became difficult to detect when moving. The detection of moving markers using the a-Si EPID was difficult even at the maximum dose-rate of 592 MU min{sup -1} due to the lower QE and longer integration time of 400 ms. Conclusions: This work demonstrates that a fast read-out, high QE APS may be useful in the tracking of moving fiducial markers during radiotherapy. Further study is required to investigate the tracking of markers moving in 3D in a treatment beam attenuated by moving patient anatomy. This will require a larger sensor with ROI read-out to maintain speed and a manageable data-rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coded aperture imaging - Predicted performance of uniformly redundant arrays

It is noted that uniformly redundant arrays (URAs) have autocorrelation functions with perfectly flat sidelobes. A generalized signal-to-noise equation has been developed to predict URA performance. The signal-to-noise value is formulated as a function of aperture transmission or density, the ratio of the intensity of a resolution element to the integrated source intensity, and the ratio of detector background noise to the integrated intensity. It is shown that the only two-dimensional URAs known have a transmission of one half. This is not a great limitation because a nonoptimum transmission of one half never reduces the signal-to-noise ratio more than 30%. The reconstructed URA image contains practically uniform noise, regardless of the object structure. URA's improvement over the single-pinhole camera is much larger for high-intensity points than for low-intensity points.

Fenimore, E. E.↗

Is There an Optimal CO2 Partial Column for Flux Inversions?

The fidelity of flux estimates from an atmospheric inversion depends on the ability of atmospheric transport models to simulate the measured quantity. For species such as CO2, with surface fluxes and a large network of surface measurements, this means correctly simulating the dynamics of the planetary boundary layer (PBL), which is one of the most uncertain aspects of atmospheric transport modeling. In contrast, the simulated total column average mole fraction of CO2 (XCO2) is largely insensitive to simulated PBL dynamics. Therefore, measurements of XCO2 provided by current and future short wave infrared (SWIR) greenhouse gas (GHG) satellites such as GOSAT and the OCO family would seem to be more appropriate to flux inversions, as far as minimizing transport model errors (the "noise") is concerned. Unfortunately, the flux-induced variation of CO2 (the "signal") is the largest within the PBL and smallest in XCO2. Therefore, assimilating XCO2 as opposed to PBL CO2 need not give us the strongest "signal to noise" in flux inversions. Recent work on GOSAT and OCO2 retrievals suggest that SWIR satellite spectra may be used to estimate a lower partial column CO2, which could be assimilated in a flux inversion, instead of XCO2.Here we report on a study to assess whether there is an optimal partial column average CO2, intermediate between PBL CO2 and XCO2, whose assimilation might yield the best signal to noise in flux inversions, where (as before) "signal" is the flux-induced variation and "noise" is the error in transport modeling. We simulate atmospheric CO2 with five different global transport models and a common surface CO2 flux over ten years. We consider the spread across the five models to be a proxy for transport model error (the "noise"), and the common variation of CO2 in all five models to be a proxy for the "signal". We compare these signals and noises at different spatiotemporal scales for different partial column specifications to investigate whether there exists an optimal partial column that has large surface flux-driven variations and yet is relatively insensitive to errors in transport models. Finally, we comment on the feasibility of estimating such a partial column from current and future SWIR GHG satellites in the light of recent work on vertically resolved CO2 from current SWIR GHG satellites.

Basu, Sourish↗

High Statistics Analysis using Anisotropic Clover Lattices: (III) Baryon-Baryon Interactions

Low-energy baryon-baryon interactions are calculated in a high-statistics lattice QCD study on a single ensemble of anisotropic clover gauge-field configurations at a pion mass of m_pi ~ 390 MeV, a spatial volume of L^3 ~ (2.5 fm)^3, and a spatial lattice spacing of b ~ 0.123 fm. Luscher’s method is used to extract nucleon-nucleon, hyperon-nucleon and hyperon-hyperon scattering phase shifts at one momentum from the one- and two-baryon ground-state energies in the lattice volume. The N-Sigma interactions are found to be highly spin-dependent, and the interaction in the ^3 S _1 channel is found to be strong. In contrast, the N-Lambda interactions are found to be spin-independent, within the uncertainties of the calculation, consistent with the absence of one-pion-exchange. The only channel for which a negative energy-shift is found is Lambda-Lambda, indicating that the Lambda-Lambda interaction is attractive, as anticipated from model-dependent discussions regarding the H-dibaryon. The NN scattering lengths are found to be small, clearly indicating the absence of any fine-tuning in the NN-sector at this pion mass. This is consistent with our previous Lattice QCD calculation of the NN interactions. The behavior of the signal-to-noise ratio in the baryon-baryon correlation functions, and in the ratio of correlation functions that yields the ground-state energy splitting

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mixed Linear/Square-Root Encoded Single-Slope Ramp Provides Low-Noise ADC with High Linearity for Focal Plane Arrays

Single-slope analog-to-digital converters (ADCs) are particularly useful for onchip digitization in focal plane arrays (FPAs) because of their inherent monotonicity, relative simplicity, and efficiency for column-parallel applications, but they are comparatively slow. Squareroot encoding can allow the number of code values to be reduced without loss of signal-to-noise ratio (SNR) by keeping the quantization noise just below the signal shot noise. This encoding can be implemented directly by using a quadratic ramp. The reduction in the number of code values can substantially increase the quantization speed. However, in an FPA, the fixed pattern noise (FPN) limits the use of small quantization steps at low signal levels. If the zero-point is adjusted so that the lowest column is onscale, the other columns, including those at the center of the distribution, will be pushed up the ramp where the quantization noise is higher. Additionally, the finite frequency response of the ramp buffer amplifier and the comparator distort the shape of the ramp, so that the effective ramp value at the time the comparator trips differs from the intended value, resulting in errors. Allowing increased settling time decreases the quantization speed, while increasing the bandwidth increases the noise. The FPN problem is solved by breaking the ramp into two portions, with some fraction of the available code values allocated to a linear ramp and the remainder to a quadratic ramp. To avoid large transients, both the value and the slope of the linear and quadratic portions should be equal where they join. The span of the linear portion must cover the minimum offset, but not necessarily the maximum, since the fraction of the pixels above the upper limit will still be correctly quantized, albeit with increased quantization noise. The required linear span, maximum signal and ratio of quantization noise to shot noise at high signal, along with the continuity requirement, determines the number of code values that must be allocated to each portion. The distortion problem is solved by using a lookup table to convert captured code values back to signal levels. The values in this table will be similar to the intended ramp value, but with a correction for the finite bandwidth effects. Continuous-time comparators are used, and their bandwidth is set below the step rate, which smoothes the ramp and reduces the noise. No settling time is needed, as would be the case for clocked comparators, but the low bandwidth enhances the distortion of the non-linear portion. This is corrected by use of a return lookup table, which differs from the one used to generate the ramp. The return lookup table is obtained by calibrating against a stepped precision DC reference. This results in a residual non-linearity well below the quantization noise. This method can also compensate for differential non-linearity (DNL) in the DAC used to generate the ramp. The use of a ramp with a combination of linear and quadratic portions for a single-slope ADC is novel. The number of steps is minimized by keeping the step size just below the photon shot noise. This in turn maximizes the speed of the conversion. High resolution is maintained by keeping small quantization steps at low signals, and noise is minimized by allowing the lowest analog bandwidth, all without increasing the quantization noise. A calibrated return lookup table allows the system to maintain excellent linearity.

Wrigley, Chris J.↗

Refinement and application of acoustic impulse technique to study nozzle transmission characteristics

An improved acoustic impulse technique was developed and was used to study the transmission characteristics of duct/nozzle systems. To accomplish the above objective, various problems associated with the existing spark-discharge impulse technique were first studied. These included (1) the nonlinear behavior of high intensity pulses, (2) the contamination of the signal with flow noise, (3) low signal-to-noise ratio at high exhaust velocities, and (4) the inability to control or shape the signal generated by the source, specially when multiple spark points were used as the source. The first step to resolve these problems was the replacement of the spark-discharge source with electroacoustic driver(s). These included (1) synthesizing on acoustic impulse with acoustic driver(s) to control and shape the output signal, (2) time domain signal averaging to remove flow noise from the contaminated signal, (3) signal editing to remove unwanted portions of the time history, (4) spectral averaging, and (5) numerical smoothing. The acoustic power measurement technique was improved by taking multiple induct measurements and by a modal decomposition process to account for the contribution of higher order modes in the power computation. The improved acoustic impulse technique was then validated by comparing the results derived by an impedance tube method. The mechanism of acoustic power loss, that occurs when sound is transmitted through nozzle terminations, was investigated. Finally, the refined impulse technique was applied to obtain more accurate results for the acoustic transmission characteristics of a conical nozzle and a multi-lobe multi-tube supressor nozzle.

Salikuddin, M.↗

Television noise-reduction device

System greatly improves signal-to-noise ratio with little or no loss in picture resolution. By storage of luminance component, which is summed with chrominance component, system performs mathematical integration of basically-repetitive television signals. Integration of signals over interval of their repetition causes little change in original signals and eliminates random noise.

Stamps, J. C.↗

Detection of the pairwise kinematic Sunyaev-Zel'dovich effect with BOSS DR11 and the Atacama Cosmology Telescope

Here, we present a new measurement of the kinematic Sunyaev-Zel'dovich effect using data from the Atacama Cosmology Telescope (ACT) and the Baryon Oscillation Spectroscopic Survey (BOSS). Using 600 square degrees of overlapping sky area, we evaluate the mean pairwise baryon momentum associated with the positions of 50,000 bright galaxies in the BOSS DR11 Large Scale Structure catalog. A non-zero signal arises from the large-scale motions of halos containing the sample galaxies. The data fits an analytical signal model well, with the optical depth to microwave photon scattering as a free parameter determining the overall signal amplitude. We estimate the covariance matrix of the mean pairwise momentum as a function of galaxy separation, using microwave sky simulations, jackknife evaluation, and bootstrap estimates. The most conservative simulation-based errors give signal-to-noise estimates between 3.6 and 4.1 for varying galaxy luminosity cuts. We discuss how the other error determinations can lead to higher signal-to-noise values, and consider the impact of several possible systematic errors. Estimates of the optical depth from the average thermal Sunyaev-Zel'dovich signal at the sample galaxy positions are broadly consistent with those obtained from the mean pairwise momentum signal.

79 ASTRONOMY AND ASTROPHYSICS↗

Practical Weak-lensing Shear Measurement with Metacalibration

Metacalibration is a recently introduced method to accurately measure weak gravitational lensing shear using only the available imaging data, without need for prior information about galaxy properties or calibration from simulations. The method involves distorting the image with a small known shear, and calculating the response of a shear estimator to that applied shear. The method was shown to be accurate in moderate-sized simulations with galaxy images that had relatively high signal-to-noise ratios, and without significant selection effects. In this work we introduce a formalism to correct for both shear response and selection biases. We also observe that for images with relatively low signal-to-noise ratios, the correlated noise that arises during the metacalibration process results in significant bias, for which we develop a simple empirical correction. To test this formalism, we created large image simulations based on both parametric models and real galaxy images, including tests with realistic point-spread functions. We varied the point-spread function ellipticity at the five-percent level. In each simulation we applied a small few-percent shear to the galaxy images. We introduced additional challenges that arise in real data, such as detection thresholds, stellar contamination, and missing data. We applied cuts on the measured galaxy properties to induce significant selection effects. Using our formalism, we recovered the input shear with an accuracy better than a part in a thousand in all cases.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-I-10: Spatially Local Statistics for Adaptive Image Filtering

Purpose: To facilitate adaptive image filtering operations, addressing spatial variations in both noise and signal. Such issues are prevalent in cone-beam projections, where physical effects such as X-ray scattering result in spatially variant noise, violating common assumptions of homogeneous noise and challenging conventional filtering approaches to signal extraction and noise suppression. Methods: We present a computational mechanism for probing into and quantifying the spatial variance of noise throughout an image. The mechanism builds a pyramid of local statistics at multiple spatial scales; local statistical information at each scale includes (weighted) mean, median, standard deviation, median absolute deviation, as well as histogram or dynamic range after local mean/median shifting. Based on inter-scale differences of local statistics, the spatial scope of distinguishable noise variation is detected in a semi- or un-supervised manner. Additionally, we propose and demonstrate the incorporation of such information in globally parametrized (i.e., non-adaptive) filters, effectively transforming the latter into spatially adaptive filters. The multi-scale mechanism is materialized by efficient algorithms and implemented in parallel CPU/GPU architectures. Results: We demonstrate the impact of local statistics for adaptive image processing and analysis using cone-beam projections of a Catphan phantom, fitted within an annulus to increase X-ray scattering. The effective spatial scope of local statistics calculations is shown to vary throughout the image domain, necessitating multi-scale noise and signal structure analysis. Filtering results with and without spatial filter adaptation are compared visually, illustrating improvements in imaging signal extraction and noise suppression, and in preserving information in low-contrast regions. Conclusion: Local image statistics can be incorporated in filtering operations to equip them with spatial adaptivity to spatial signal/noise variations. An efficient multi-scale computational mechanism is developed to curtail processing latency. Spatially adaptive filtering may impact subsequent processing tasks such as reconstruction and numerical gradient computations for deformable registration. NIH Grant No. R01-184173.

60 APPLIED LIFE SCIENCES↗