Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL CONDITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Trial of a proposed protocol for constancy control of digital mammography systems

Purpose: Evaluate the utility of tests in a proposed protocol for constancy control of digital mammography systems. Methods: The protocol contained tests for image acquisition, mechanical function and safety, monitors and printers, and viewing conditions. Nine sites with digital systems from four equipment manufacturers were recruited. Dedicated PMMA test objects and Excel spreadsheets were developed. Quantitative measurements were done on processed images for systems where these images were the ones most readily available. For daily assessment of the automatic exposure control system, a homogeneous PMMA phantom was exposed under clinical conditions. The mAs and signal to noise ratio (SNR) were recorded, the deviation from a target value calculated, and the resulting image inspected for artifacts. For thickness tracking, the signal difference to noise ratio obtained for three thicknesses was calculated. Detector uniformity was assessed through comparison of SNR values for regions of interest in the center and corners of an image of a homogeneous test object. Mechanical function and safety control included a compression test, a checklist for mechanical aspects, and control of field alignment. Monitor performance was evaluated by visual inspection of the AAPM TG 18 QC test image [E. Samei et al., ''Assessment of display performance for medical imaging systems,'' Task Group 18 (Madison, WI, April 2005)]. Results: For quantitative parameters, target values and tolerance limits were established. Test results exceeding the limits were registered. Most systems exhibited stable mAs values, indicating that the tolerance limit of {+-}10% was readily achievable. The SNR also showed little variation, indicating that the tolerance limit of {+-}20% was too wide. At one site, a defective grid caused artifacts that were visible in the test images. The monitor controls proved more difficult to implement due to both difficulties importing and displaying the test image, and the radiographic technologists not getting necessary access to the reading stations. Conclusions: The proposed tests could easily be performed by trained radiographic technologists and within a time frame comparable to similar programs for analog systems. Tests with quantitative measures were more readily performed than procedures that required a subjective evaluation. Several of the proposed tests revealed equipment performance that required intervention, and which would otherwise have gone unnoticed. They therefore defend a place in a vendor-independent constancy control protocol.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical Note: Removing the stem effect when performing Ir-192 HDR brachytherapy in vivo dosimetry using plastic scintillation detectors: A relevant and necessary step

Purpose: The purpose of this study was to investigate whether or not a stem effect removal technique is necessary when performing Ir-192 HDR brachytherapy in vivo dosimetry using a scintillation detector. Methods: A red-green-blue photodiode connected to a multichannel electrometer was used to detect the light emitted from a plastic scintillation detector (PSD) during irradiation with an Ir-192 HDR brachytherapy source. Accuracy in dose measurement was compared with and without the use of stem effect removal techniques. Monochromatic and polychromatic filtration techniques were studied. An in-house template was built for accurate positioning of catheters in which the source and the PSD were inserted. Dose distribution was measured up to 5 cm from source to detector in the radial and longitudinal directions. Results: The authors found the stem effect to be particularly important when the source was close to the optical fiber guide and far from the scintillation component of the detector. It can account for up to (72{+-}3)% of the signal under clinically relevant conditions. The polychromatic filtration outperformed the monochromatic filtration as well as the absence of filtration in regard to dose measurement accuracy. Conclusions: It is necessary to implement a stem effect removal technique when building a PSD for in vivo dosimetry during Ir-192 HDR brachytherapy. The PSD that the authors have developed for this study would be suitable for such an application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intelligent Integrated Machining: Handheld XRF for Mapping Zr Coating and Al-6061 Cladding Thickness in RERTR Fuel Elements

An inexpensive commercially available handheld energy dispersive x‐ray fluorescence spectrometer is used to provide a rapid non‐destructive estimate of coating and/or cladding thickness in situ . The portable XRF instrument contains a battery‐operated low‐power polychromatic source coupled with a Peltier‐cooled silicon drift detector; built‐in analysis software based upon the Method of Fundamental Parameters converts measured spectral intensities to elemental concentrations, reported as normalized weight percentages. Using detected signals from elements unique to the base material and coating or cladding materials, calibration curves and associated empirical algorithms for determining the thickness of the high‐purity zirconium coating on an RERTR fuel element prior to cladding with aluminum, and for determining the thickness of the Al‐6061 cladding after HIP for a known zirconium layer thickness, are constructed. For Zr over bare DU‐10Mo, agreement between the measured and the calculated thickness is ± 5% or better. For the multilayer system consisting of Al‐6061 over Zr over Du‐10Mo, agreement between calculated and measured thickness is ± 10‐15% over the thickness range of interest. Simultaneous estimates for the Al cladding and underlying Zr coating can be made using the elemental composition output only when the Mo signal is in the quasi‐static range (corresponding to Al thicknesses of ~15 mils (0.381 mm) and greater) and not so low that measurement error is greater than the signal itself; under these conditions, accuracy is on the order of ±15 – 20%. More accurate determination of both Zr and Al thickness simultaneously may be possible if the count‐rates associated with individual fluorescent lines in the multilayer sample are available rather than just the weight percent composition currently output by the XRF analyzer software.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Subdiffraction instrumentation development and application to the elucidation of biological systems, thin films, and organic photovoltaic devices

Fluorescence and Raman instrumentation was developed to elucidate morphology, information on local environment, and material properties of target systems. Far-field fluorescence and luminescence spectroscopic measurements were performed using a pulsed super-continuum laser source and detector with high temporal resolution. With this arrangement morphologies of structures were coupled with time-correlated data. Polymeric beads and Alexa Fluor 594-phalloidin labeled cellular actin structures of cultured cells were imaged below the diffraction limit using stimulated emission depletion to resolve structures to ≈40nm. Lifetime imaging revealed a 2.0 ± 0.1 ns lifetime for fluorescently-labeled beads in confocal and depletion imaging modes. Depletion imaging was also able to display a change of 2.2 to 2.9 ns for different regions of the cellular actin network of cultured cells with a possible difference in lifetime caused by tryptophan quenching of the dye. Subdiffraction imaging with a resolution of ≈40 nm was also accomplished using luminescence depletion of photostable giant CdSe/14CdS nanocrystal quantum dots in air. Nanocrystal quantum dots, typically not prone to depletion, exhibited this phenomenon when excited with an energy of 50 pJ and 2 nJ of depletion energy. Luminescence depletion required half the energy compared to stimulated emission depletion to achieve the same resolution limit. The luminescence was depleted by as much as ≈92% with no observable photobleaching. Raman measurements of polymer films were performed with 532-nm laser illumination using scanning angle and conventional 180° backscattering modes to determine chemical information. The scanning angle mode achieved an angle resolution of 0.09° and was used to probe a thin layer of polystyrene as well as a diblock copolymer of polystyrene and poly(3-hexylthiophene-2,5-diyl). Enhancements to the Raman signals at selected angles lower than the critical angle for total internal reflection, characteristic of waveguides, were measured. An additional enhancement in the Raman signal results from resonant conditions for the diblock copolymer. The epi-collection geometry was used to gain spectroscopic information regarding to the stability of heterojunction solar cells with the aid of resonance Raman spectroscopy. Raman spectral characteristics corresponding to thiophene-based functional groups were used to relate stability of the polymers under different processing conditions such as solvent and thermal annealing while undergoing laser induced photodegradation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spatial and temporal dynamics of receptor for advanced glycation endproducts, integrins, and actin cytoskeleton as probed with fluorescence-based imaging techniques

Systematic spatial and temporal fluctuations are a fundamental part of any biological process. For example, lateral diffusion of membrane proteins is one of the key mechanisms in their cellular function. Lateral diffusion governs how membrane proteins interact with intracellular, transmembrane, and extracellular components to achieve their function. Herein, fluorescence-based techniques are used to elucidate the dynamics of receptor for advanced glycation end-products (RAGE) and integrin membrane proteins. RAGE is a transmembrane protein that is being used as a biomarker for various diseases. RAGE dependent signaling in numerous pathological conditions is well studied. However, RAGE lateral diffusion in the cell membrane is poorly understood. For this purpose, effect of cholesterol, cytoskeleton dynamics, and presence of ligand on RAGE lateral diffusion is investigated.

59 BASIC BIOLOGICAL SCIENCES↗

Long range laser traversing system

A study was carried out to determine the feasibility of a man-portable receiver system for land survey, which would be capable of detecting the optical scatter due to molecular and aerosol constituents of the atmosphere from a vertical laser beam. Tests were run with a beacon and receiver separated by approximately one mile. The system was consistently able to detect the laser signal regardless of background conditions.

Caudill, L. O.↗

Near optimum digital phase locked loops.

Near optimum digital phase locked loops are derived utilizing nonlinear estimation theory. Nonlinear approximations are employed to yield realizable loop structures. Baseband equivalent loop gains are derived which under high signal to noise ratio conditions may be calculated off-line. Additional simplifications are made which permit the application of the Kalman filter algorithms to determine the optimum loop filter. Performance is evaluated by a theoretical analysis and by simulation. Theoretical and simulated results are discussed and a comparison to analog results is made.

Polk, D. R.↗

Performance analysis of digital FM demodulators for fading channels in the threshold region

The quasi-optimum digital FM demodulators for fading channels reported earlier (1975) reflected the system performance accurately under high signal to noise ratio conditions. In this paper, the prediction of the system performance for low SNR values is considered. A new set of error variance algorithms is developed from the filter algorithm assuming a Gaussian distribution for the state estimation errors and taking the effect of high frequency terms into consideration. Simulation analysis for an FM system with Rician fading channel shows that these algorithms predict the system performance accurately in the threshold region.

Dharamsi, M. T.↗

EUV observations of the equatorial aurora

Using the Apollo-Soyuz mission's extreme ultraviolet telescope, it proved possible to observe the equatorial aurora on four different occasions. The observations were made from 220 km in quiet geomagnetic conditions. In all cases, signals were well above ambient background in the 50 to 150 A, 114 to 150 A, 170 to 600 A, and 500 to 780 A bands. The existence of a strong feature in the 50 to 150 A region may be an indication that other elements besides helium - possibly oxygen and nitrogen - contribute to the enhancement.

Paresce, F.↗

Some implications of reciprocity for two-way clock synchronization

The difficulties related to propagation perturbances in one-way and two-way methods for the synchronization of remote clocks are defined, and a possible means of circumventing these problems in the two-way method is suggested. In the two-way method, if signals are launched from two sources, A and B, then the two signals arriving at A and B will be displaced in arrival time by an amount that is equal to the difference in launch times of the two signals. Thus, the only condition to comparing clocks is that the medium be isotropic. The practice implementation of this is explored theoretically, in some detail, with respect to the Loran-C navigation system.

Jespersen, J. L.↗

Saturation Phenomena in LIF Measurements, Appendix B

Optical saturation is the phenomenon in which the laser-induced rates of absorption and spontaneous emission between two levels, induced by a laser, become comparable to or greater than the spontaneous emission and collision rates connecting these levels. This results in the excited state population N(u) acquiring a value of similar magnitude to that of the ground state, N(e). Under these conditions the observed fluorescence signal, which is proportional to N(u), is no longer linearly dependent on laser intensity I, but increases at a slower rate, and in principle ultimately becomes independent of I. A conceptual picture of optical saturation using a two-level picture is described. This is, however, inadequate for the description of a real experiment involving a molecule, such as OH, for several reasons, which will be explained briefly; these are the multi-level nature of the electronic states and energy transfer among them and effects due to spatial, spectral, and temporal fluctuations in the laser pulse.

Source record↗

Data presentation techniques for rotating machinery malfunction diagnosis

Baseline steady state data is excellent for documentation of vibration signals at normal operating conditions. Assuming that a set of initial data was acquired with the machinery in a good state of repair, any future changes or deterioration in mechanical condition can be easily compared to the baseline information. Often this type of comparison will yield sufficient information for evaluation of the problem. However, many malfunctions require the analysis of transient data in order to identify the malfunction. Steady-state data formats consist of: Time Base Waveform, Orbit, Spectrum. Transient data formats consist of: Polar, Bode, Cascade. Our objective is to demonstrate the use of the above formats to diagnose a machine malfunction. A turbine-driven compressor train is chosen as an example. The machine train outline drawing is shown.

Spettel, T.↗

Improved VAS regression soundings of mesoscale temperature structure observed during the 1982 atmospheric variability experiment

An Atmospheric Variability Experiment (AVE) was conducted over the central U.S. in the spring of 1982, collecting radiosonde date to verify mesoscale soundings from the VISSR Atmospheric Sounder (VAS) on the GOES satellite. Previously published VAS/AVE comparisons for the 6 March 1982 case found that the satellite retrievals scarcely detected a low level temperature inversion or a mid-tropospheric cold pool over a special mesoscale radiosonde verification network in north central Texas. The previously published regression and physical retrieval algorithms did not fully utilize VAS' sensitivity to important subsynoptic thermal features. Therefore, the 6 March 1982 case was reprocessed adding two enhancements to the VAS regression retrieval algorithm: (1) the regression matrix was determined using AVE profile data obtained in the region at asynoptic times, and (2) more optimistic signal-to-noise statistical conditioning factors were applied to the VAS temperature sounding channels. The new VAS soundings resolve more of the low level temperature inversion and mid-level cold pool. Most of the improvements stems from the utilization of asynoptic radiosonde observations at NWS sites. This case suggests that VAS regression soundings may require a ground-based asynoptic profiler network to bridge the gap between the synoptic radiosonde network and the high resolution geosynchronous satellite observations during the day.

Chesters, Dennis↗

The role of modeling and flight testing in rotorcraft parameter identification

The importance of recognizing that each lower-order model used for rotorcraft parameter identification has a limited range of applicability is illustrated in some detail. Examples are given to illustrate the use of conditioning the test input signals and the potential of using multi-axis test inputs to enhance the parameter identifiability. The paper discusses the benefits and limitations of using frequency sweeps as flight-test input signals for identification of frequency response for rotorcraft and for the subsequent fitting of parametric transfer-function models. This paper demonstrates the major role played by analytical modeling and the understanding of the physics involved in the rotorcraft flight dynamics, particularly understanding the limit of lower-order models, in achieving successful rotorcraft parameter identification.

Chen, R. T. N.↗

Force-Balance Dynamic Display

Balance dynamic display unit (BDDU) is compact system conditioning six dynamic analog signals so they are monitored simultaneously in real time on single-trace oscilloscope. Typical BDDU oscilloscope display in scan mode shows each channel occupying one-sixth of total trace. System features two display modes usable with conventional, single-channel oscilloscope: multiplexed six-channel "bar-graph" format and single-channel display. Two-stage visual and audible limit alarm provided for each channel.

Ferris, Alice T.↗

Land mobile satellite transmission measurements at 869 MHz. A comparison of error probabilities for various message block durations and fade margins as a function of vegetation shadowing

In order to give vehicles travelling in rural areas of the U.S. access to the telephone network, a Land Mobile Satellite System is being planned. Previously presented data by the author were analyzed for the probability that the received signal level dropped below a threshold during short time blocks of various signal durations and the conditional probability that such an event would reoccur after a given delay. If it assumed that a fade threshold crossing of even 1 msec would produce an error in the transmission, then the derived quantities can be considered error probabilities. Extensive tables and graphs are presented with the results from the analysis. They can be used to devise communication strategies which will provide improved link availability in the presence of vegetation shadowing.

Vogel, Wolfhard J.↗

Efficient detection and signal parameter estimation with applications to high dynamic GPS receivers

A novel technique for simultaneously detecting data and estimating the parameters of a received carrier signal phase modulated by unknown data and experiencing very high Doppler, Doppler rate, etc. is discussed. Such a situation arises, for example, in the case of Global Positioning Systems (DPS) where the signal parameters are directly related to the position, velocity and acceleration of the GPS receiver. The proposed scheme is based upon first estimating the received signal local (data dependent) parameters over two consecutive bit periods, followed by the detection of a possible jump in these parameters. The presence of a detected jump signifies a data transition which is then removed from the received signal. This effectively demodulated signal is then processed to provide the estimates of global (data independent) parameters of the signal related to the position, velocity, etc. of the receiver. One of the key features of the proposed algorithm is the introduction of two different schemes which can provide an improvement of up to 3 dB over the conventional implementation of Kalman filter as applied to phase and frequency estimation, under low to medium signal-to-noise ratio conditions.

Kumar, R.↗