Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Frame”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

On the effect of scalar flux weighing of linearly anisotropic scattering matrices in few-group transport calculations

The majority of the codes available for homogenized group constant generation for deterministic transport calculations apply the approximation of scalar flux weighting during energy group condensation of higher-order anisotropic scattering matrices. In this paper, we discuss the effect of scalar flux weighting of the linearly anisotropic scattering matrices in the frame of S P{sub 3} and S{sub 12} calculations performed for a two-dimensional VVER-440 reactor benchmark. To compare group constants generated for two neutron energy groups, an infinite pin cell was homogenized with Serpent 2 and ERANOS ECCO. Serpent 2 applies scalar flux, while ERANOS ECCO performs current weighting of the linearly anisotropic scattering matrices during energy group condensation. For analyzing the effect of the various weighting options, three simple reactor models were built assuming different core sizes using standard rectangular assemblies with 15*15 fuel pins. Diffusion, SP{sub 3} and S{sub 12} calculations were performed for the 3 models using group constants generated with Serpent 2 and ERANOS ECCO. The effect of scalar flux weighting of linearly anisotropic scattering matrices is shown by comparing the decrease in reactivity due to the decreased reactor size, as well as the assembly power distribution to reference results obtained with Serpent 2 Monte Carlo calculations. Neglecting higher than linearly anisotropic scattering and indirect application of diffusion coefficients in higher-order transport calculations is advised if angular flux-moment spectra weighted higher-order scattering matrices cannot be generated. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Microstructure analyses and thermoelectric properties of Ag{sub 1-x}Pb{sub 18}Sb{sub 1+y}Te{sub 20}

This study reports microstructural investigations of long-term annealed Ag{sub 1-x}Pb{sub m}Sb{sub 1+y}Te{sub 2+m} (m=18, x=y=0, hereinafter referred to as AgPb{sub 18}SbTe{sub 20}) (Lead-Antimony-Silver-Tellurium, LAST-18) as well as of Ag{sub 1-x}Pb{sub 18}Sb{sub 1+y}Te{sub 20}, i.e. Ag-deficient and Sb-excess LAST-18 (x{ne}0,y{ne}0), respectively. Two different length scales are explored. The micrometer scale was evaluated by SEM to analyze the volume fraction and the number of secondary phases as well as the impact of processing parameters on the homogeneity of bulk samples. For AgPb{sub 18}SbTe{sub 20}, site-specific FIB liftout of TEM lamellae from thermoelectrically characterized samples was accomplished to investigate the structure on the nanometer scale. High-resolution TEM and energy-filtered TEM were performed to reveal shape and size distribution of nanoprecipitates, respectively. A hypothesis concerning the structure-property relationship is set out within the frame of a gradient annealing experiment. This study is completed by results dealing with inhomogeneities on the micrometer scale of Ag{sub 1-x}Pb{sub 18}Sb{sub 1+y}Te{sub 20} and its electronic properties. Highlights: Black-Right-Pointing-Pointer SEM and TEM microstructure investigation of long-term annealed AgPb{sub 18}SbTe{sub 20}. Black-Right-Pointing-Pointer SEM and thermoelectric studies on Ag{sub 1-x}Pb{sub 18}Sb{sub 1+y}Te{sub 20}. Black-Right-Pointing-Pointer Discussion concerning structure-property relationship in long-term annealed AgPb{sub 18}SbTe{sub 20}. Black-Right-Pointing-Pointer Correlation between Ag{sub 1-x}Pb{sub 18}Sb{sub 1+y}Te{sub 20} microscale structure and electronic properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Amplitude equations for polycrystalline materials with interaction between composition and stress

Here, we investigate the ability of frame-invariant amplitude equations [G. H. Gunaratne, Q. Ouyang, and H. Swinney, Phys. Rev. E 50, 2802 (1994)] to describe quantitatively the evolution of polycrystalline microstructures and we extend this approach to include the interaction between composition and stress. Validations for elemental materials include studies of the Asaro-Tiller-Grinfeld morphological instability of a stressed crystal surface, polycrystalline growth from the melt, grain-boundary energies over a wide range of misorientation, and grain-boundary motion coupled to shear deformation. Amplitude equations with accelerated strain relaxation in the solid are shown to model accurately the Asaro-Tiller-Grinfeld instability. Polycrystalline growth is also well described. However, the survey of grain-boundary energies shows that the approach is only valid for a restricted range of misorientations as a direct consequence of an amplitude expansion. This range covers approximately half the complete range allowed by crystal symmetry for some fixed reference set of density waves used in the expansion. Over this range, coupled motion to shear is well described by known geometrical rules and a transition from coupling to sliding motion is also reproduced. Amplitude equations for alloys are derived phenomenologically in a Ginzburg-Landau spirit. Vegard’s law is shown to be naturally described by seeking a gauge-invariant form of those equations under a transformation that corresponds to a lattice expansion and deviations from Vegard’s law can be easily incorporated. Those equations realistically describe the dilute alloy limit and have the same flexibility as conventional phase-field models for incorporating arbitrary free-energy/composition curves. As a test of this approach, we recover known analytical expressions for open-system elastic constants [F. C. Larché and J. W. Cahn, Acta Metall. 33, 331 (1985)].

36 MATERIALS SCIENCE↗

A compact high-performance low-field NMR apparatus for measurements on fluids at very high pressures and temperatures

We discuss an innovative new high-performance apparatus for performing low-field Nuclear Magnetic Resonance (NMR) relaxation times and diffusion measurements on fluids at very high pressures and high temperatures. The apparatus sensor design and electronics specifications allow for dual deployment either in a fluid sampling well logging tool or in a laboratory. The sensor and electronics were designed to function in both environments. This paper discusses the use of the apparatus in a laboratory environment. The operating temperature and pressure limits, and the signal-to-noise ratio (SNR) of the new system exceed by a very wide margin what is currently possible. This major breakthrough was made possible by a revolutionary new sensor design that breaks many of the rules of conventional high pressure NMR sensor design. A metallic sample holder capable of operating at high pressures and temperatures is provided to contain the fluid under study. The sample holder has been successfully tested for operation up to 36 Kpsi. A solenoid coil wound on a slotted titanium frame sits inside the metallic sample holder and serves as an antenna to transmit RF pulses and receive NMR signals. The metal sample holder is sandwiched between a pair of gradient coils which provide a linear field gradient for pulsed field gradient diffusion measurements. The assembly sits in the bore of a low-gradient permanent magnet. The system can operate over a wide frequency range without the need for tuning the antenna to the Larmor frequency. The SNR measured on a water sample at room temperature is more than 15 times greater than that of the commercial low-field system in our laboratory. Thus, the new system provides for data acquisition more than 200 times faster than was previously possible. Laboratory NMR measurements of relaxations times and diffusion coefficients performed at pressures up to 25 Kpsi and at temperatures up to 175 °C with crude oils enlivened with dissolved hydrocarbon gases (referred to as “live oils”) are shown. This is the first time low-field NMR measurements have been performed at such high temperatures and pressures on live crude oil samples. We discuss the details of the apparatus design, tuning, calibration, and operation. NMR data acquired at multiple temperatures and pressures on a live oil sample are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical Modelling of Radionuclide Migration in the Context of a Near-Surface LILW Disposal Facility - 18618

The reference solution for the management of low and intermediate level short-lived waste (LILW) in France consists in their emplacement in concrete vaults built at the near-surface. The corresponding disposal facility under operation by the French waste management organization (Andra), is located in North-eastern France and planned to be closed in 2060. The safety case developed by Andra has to show the evidence that, amongst other aspects, the radionuclide transfer through the confinement barriers will occur in such a way that the human and environmental exposure will be as low as reasonably achievable (ALARA) and in accordance with the dose constraints. For this purpose, modelling is used to integrate uncertainties about the characteristics of concrete components, waste and water table and their evolution in time and space. At last, modelling is finally used to investigate the radiological impact of specific scenarios in which the failure of safety barriers occurs. In the frame of its technical review of the safety assessment, the French Institute for Radiological Protection and Nuclear Safety (IRSN) also performs such kind of numerical modelling of radionuclide fate from the waste to the hydrogeological outlets, in order to check whether the assessment performed by Andra takes into account sufficiently conservative assumptions. The present work aims to evaluate the role of components of the vaults on radionuclide transport during the post-closure period over a few thousand years. For this purpose, IRSN carries out numerical calculations with MELODIE software, which simulates water flow and transport of species, in order to simulate radionuclide migration from waste packages emplaced in a concrete vault to the surrounding groundwater. The developed transport model focuses on 3-H radionuclide and integrates Andra's main assumptions (release model from the waste packages, chemical and hydraulic properties of the vault components, shrinkage and cracks in concrete components). An adaptive mesh method, based on an a posteriori error estimator, was used to model the cracks and the consideration of a strong heterogeneity in the hydraulic and transport parameters values in the different components of the model. This method shows an improvement of results of about 40 times, whereas the mesh size was increased by only 2%. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MIRC-X: A Highly Sensitive Six-telescope Interferometric Imager at the CHARA Array

Michigan InfraRed Combiner-eXeter (MIRC-X) is a new highly sensitive six-telescope interferometric imager installed at the CHARA Array that provides an angular resolution equivalent of up to a 330 m diameter baseline telescope in J- and H-band wavelengths ((λ/(2B))∼0.6 mas). We upgraded the original Michigan InfraRed Combiner (MIRC) instrument to improve sensitivity and wavelength coverage in two phases. First, a revolutionary sub-electron noise and fast-frame-rate C-RED ONE camera based on an SAPHIRA detector was installed. Second, a new-generation beam combiner was designed and commissioned to (i) maximize sensitivity, (ii) extend the wavelength coverage to J band, and (iii) enable polarization observations. A low-latency and fast-frame-rate control software enables high-efficiency observations and fringe tracking for the forthcoming instruments of the CHARA Array. Since mid-2017, MIRC-X has been offered to the community and has demonstrated best-case H-band sensitivity down to 8.2 correlated magnitude. MIRC-X uses single-mode fibers to coherently combine the light from six telescopes simultaneously with an image-plane combination scheme and delivers a visibility precision better than 1%, and closure phase precision better than 1°. MIRC-X aims at (i) imaging protoplanetary disks, (ii) detecting exoplanets with precise astrometry, and (iii) imaging stellar surfaces and starspots at an unprecedented angular resolution in the near-infrared. In this paper, we present the instrument design, installation, operation, and on-sky results, and demonstrate the imaging capability of MIRC-X on the binary system ι Peg. The purpose of this paper is to provide a solid reference for studies based on MIRC-X data and to inspire future instruments in optical interferometry.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-168: Automated Pancreas Segmentation Based On Dynamic MRI

Purpose: MRI guided radiotherapy is particularly attractive for abdominal targets with low CT contrast. To fully utilize this modality for pancreas tracking, automated segmentation tools are needed. A hybrid gradient, region growth and shape constraint (hGReS) method to segment 2D upper abdominal dynamic MRI is developed for this purpose. Methods: 2D coronal dynamic MR images of 2 healthy volunteers were acquired with a frame rate of 5 f/second. The regions of interest (ROIs) included the liver, pancreas and stomach. The first frame was used as the source where the centers of the ROIs were annotated. These center locations were propagated to the next dynamic MRI frame. 4-neighborhood region transfer growth was performed from these initial seeds for rough segmentation. To improve the results, gradient, edge and shape constraints were applied to the ROIs before final refinement using morphological operations. Results from hGReS and 3 other automated segmentation methods using edge detection, region growth and level set were compared to manual contouring. Results: For the first patient, hGReS resulted in the organ segmentation accuracy as measure by the Dices index (0.77) for the pancreas. The accuracy was slightly superior to the level set method (0.72), and both are significantly more accurate than the edge detection (0.53) and region growth methods (0.42). For the second healthy volunteer, hGReS reliably segmented the pancreatic region, achieving a Dices index of 0.82, 0.92 and 0.93 for the pancreas, stomach and liver, respectively, comparing to manual segmentation. Motion trajectories derived from the hGReS, level set and manual segmentation methods showed high correlation to respiratory motion calculated using a lung blood vessel as the reference while the other two methods showed substantial motion tracking errors. hGReS was 10 times faster than level set. Conclusion: We have shown the feasibility of automated segmentation of the pancreas anatomy based on dynamic MRI.

60 APPLIED LIFE SCIENCES↗

High Flux Isotope Reactor Low-Enriched Uranium Low Density Silicide Fuel Design Parameters

High Flux Isotope Reactor (HFIR) highly enriched uranium (HEU) to low-enriched uranium (LEU) conversion activities are ongoing as part of the Department of Energy (DOE) National Nuclear Security Administration (NNSA)’s nuclear nonproliferation mission. Design activities studying the conversion of HFIR from HEU to LEU fuel explored different fuel design features and shapes with a low density uranium-silicide dispersion (U 3 Si 2 -Al) fuel, which has a uranium density of 4.8 gU/cm 3 . The goal of these studies is to generate several HFIR LEU fuel designs of varying fuel fabrication complexity that meet the current HEU performance metrics and safety requirements. The documented designs will serve as references for fuel fabrication and qualification activities. Recent advancements in modeling and simulation tools enable quick prototyping of fuel designs. Shift, a Monte Carlo neutron transport and depletion tool optimized for high-performance computing (HPC) architectures, is used for efficient fuel cycle and performance metrics calculations. The HFIR Steady State Heat Transfer Code (HSSHTC) is used to vet the thermal safety margin. Also, a new automation tool that connects all fuel design analysis steps, named Python HFIR Analysis and Measurement Engine (PHAME), has been developed to expedite the design study in an efficient and reproducible manner. Leveraging these tools, several candidate fuel designs were selected for varying fabrication complexity. This report provides design feature details for four selected HFIR LEU low density U 3 Si 2 -Al fuel designs and their corresponding performance and safety metrics. Nominal, best-estimate design parameters and irradiation conditions, including fission rate densities, power densities, heat fluxes, and cumulative fission densities are provided for candidate fuel designs relevant to framing irradiation experiments to support fuel qualification efforts. Simulations show that the low density U 3 Si 2 -Al, with design features to enhance safety, can meet HEU core performance metrics and safety requirements if the reactor power is increased from 85 MW (HEU) to 95 MW (LEU) and if the active fuel length is increased from 50.80 cm (HEU) to 55.88 cm (LEU).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Planck 2013 results. V. LFI calibration

We discuss the methods employed to photometrically calibrate the data acquired by the Low Frequency Instrument on Planck. Our calibration is based on a combination of the orbital dipole plus the solar dipole, caused respectively by the motion of the Planck spacecraft with respect to the Sun and by motion of the solar system with respect to the cosmic microwave background (CMB) rest frame. The latter provides a signal of a few mK with the same spectrum as the CMB anisotropies and is visible throughout the mission. In this data releasewe rely on the characterization of the solar dipole as measured by WMAP. We also present preliminary results (at 44 GHz only) on the study of the Orbital Dipole, which agree with the WMAP value of the solar system speed within our uncertainties. We compute the calibration constant for each radiometer roughly once per hour, in order to keep track of changes in the detectors’ gain. Since non-idealities in the optical response of the beams proved to be important, we implemented a fast convolution algorithm which considers the full beam response in estimating the signal generated by the dipole. Moreover, in order to further reduce the impact of residual systematics due to sidelobes, we estimated time variations in the calibration constant of the 30 GHz radiometers (the ones with the largest sidelobes) using the signal of an internal reference load at 4 K instead of the CMB dipole. We have estimated the accuracy of the LFI calibration following two strategies: (1) we have run a set of simulations to assess the impact of statistical errors and systematic effects in the instrument and in the calibration procedure; and (2) we have performed a number of internal consistency checks on the data and on the brightness temperature of Jupiter. Errors in the calibration of this Planck/LFI data release are expected to be about 0.6% at 44 and 70 GHz, and 0.8% at 30 GHz. Both these preliminary results at low and high ℓ are consistent with WMAP results within uncertainties and comparison of power spectra indicates good consistency in the absolute calibration with HFI (0.3%) and a 1.4σ discrepancy with WMAP (0.9%).

79 ASTRONOMY AND ASTROPHYSICS↗

Conditions for reliable time-resolved dosimetry of electronic portal imaging devices for fixed-gantry IMRT and VMAT

Purpose: The continuous scanning mode of electronic portal imaging devices (EPID) that offers time-resolved information has been newly explored for verifying dynamic radiation deliveries. This study seeks to determine operating conditions (dose rate stability and time resolution) under which that mode can be used accurately for the time-resolved dosimetry of intensity-modulated radiation therapy (IMRT) beams.Methods: The authors have designed the following test beams with variable beam holdoffs and dose rate regulations: a 10 Multiplication-Sign 10 cm open beam to serve as a reference beam; a sliding window (SW) beam utilizing the motion of a pair of multileaf collimator (MLC) leaves outside the 10 Multiplication-Sign 10 cm jaw; a step and shoot (SS) beam to move the pair in step; a volumetric modulated arc therapy (VMAT) beam. The beams were designed in such a way that they all produce the same open beam output of 10 Multiplication-Sign 10 cm. Time-resolved ion chamber measurements at isocenter and time-resolved and integrating EPID measurements were performed for all beams. The time-resolved EPID measurements were evaluated through comparison with the ion chamber and integrating EPID measurements, as the latter are accepted procedures. For two-dimensional, time-resolved evaluation, a VMAT beam with an infield MLC travel was designed. Time-resolved EPID measurements and Monte Carlo calculations of such EPID dose images for this beam were performed and intercompared.Results: For IMRT beams (SW and SS), the authors found disagreement greater than 2%, caused by frame missing of the time-resolved mode. However, frame missing disappeared, yielding agreement better than 2%, when the dose rate of irradiation (and thus the frame acquisition rates) reached a stable and planned rate as the dose of irradiation was raised past certain thresholds (a minimum 12 s of irradiation per shoot used for SS IMRT). For VMAT, the authors found that dose rate does not affect the frame acquisition rate, thereby causing no frame missing. However, serious inplanar nonuniformities were found. This could be overcome by sacrificing temporal resolution (10 frames or 0.95 s/image): the continuous images agreed with ion chamber responses at the center of EPID and the calculation two-dimensionally in a time-resolved manner.Conclusions: The authors have determined conditions under which the continuous mode can be used for time-resolved dosimetry of fixed-gantry IMRT and VMAT and demonstrated it for VMAT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Conceptual Design of Forced Convection Molten Salt Heat Transfer Testing Loop

This report develops a proposal to design and construct a forced convection test loop. A detailed test plan will then be conducted to obtain data on heat transfer, thermodynamic, and corrosion characteristics of the molten salts and fluid-solid interaction. In particular, this report outlines an experimental research and development test plan. The most important initial requirement for heat transfer test of molten salt systems is the establishment of reference coolant materials to use in the experiments. An earlier report produced within the same project highlighted how thermophysical properties of the materials that directly impact the heat transfer behavior are strongly correlated to the composition and impurities concentration of the melt. It is therefore essential to establish laboratory techniques that can measure the melt composition, and to develop purification methods that would allow the production of large quantities of coolant with the desired purity. A companion report describes the options available to reach such objectives. In particular, that report outlines an experimental research and development test plan that would include following steps: •Molten Salts: The candidate molten salts for investigation will be selected. •Materials of Construction: Materials of construction for the test loop, heat exchangers, and fluid-solid corrosion tests in the test loop will also be selected. •Scaling Analysis: Scaling analysis to design the test loop will be performed. •Test Plan: A comprehensive test plan to include all the tests that are being planned in the short and long term time frame will be developed. •Design the Test Loop: The forced convection test loop will be designed including extensive mechanical design, instrument selection, data acquisition system, safety requirements, and related precautionary measures. •Fabricate the Test Loop. •Perform the Tests. •Uncertainty Analysis: As a part of the data collection, uncertainty analysis will be performed to develop probability of confidence in what is measured in the test loop. Overall, the testing loop will allow development of needed heat transfer related thermophysical parameters for all the salts, validate existing correlations, validate measuring instruments under harsh environment, and have extensive corrosion testing of materials of construction.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Joint surface reconstruction and 4D deformation estimation from sparse data and prior knowledge for marker-less Respiratory motion tracking

Purpose: The intraprocedural tracking of respiratory motion has the potential to substantially improve image-guided diagnosis and interventions. The authors have developed a sparse-to-dense registration approach that is capable of recovering the patient's external 3D body surface and estimating a 4D (3D + time) surface motion field from sparse sampling data and patient-specific prior shape knowledge.Methods: The system utilizes an emerging marker-less and laser-based active triangulation (AT) sensor that delivers sparse but highly accurate 3D measurements in real-time. These sparse position measurements are registered with a dense reference surface extracted from planning data. Thereby a dense displacement field is recovered, which describes the spatio-temporal 4D deformation of the complete patient body surface, depending on the type and state of respiration. It yields both a reconstruction of the instantaneous patient shape and a high-dimensional respiratory surrogate for respiratory motion tracking. The method is validated on a 4D CT respiration phantom and evaluated on both real data from an AT prototype and synthetic data sampled from dense surface scans acquired with a structured-light scanner.Results: In the experiments, the authors estimated surface motion fields with the proposed algorithm on 256 datasets from 16 subjects and in different respiration states, achieving a mean surface reconstruction accuracy of ±0.23 mm with respect to ground truth data—down from a mean initial surface mismatch of 5.66 mm. The 95th percentile of the local residual mesh-to-mesh distance after registration did not exceed 1.17 mm for any subject. On average, the total runtime of our proof of concept CPU implementation is 2.3 s per frame, outperforming related work substantially.Conclusions: In external beam radiation therapy, the approach holds potential for patient monitoring during treatment using the reconstructed surface, and for motion-compensated dose delivery using the estimated 4D surface motion field in combination with external-internal correlation models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Quest for New Correlations in the Realm of the Gamma-Ray Burst—Supernova Connection

Gamma-ray bursts (GRBs) are very energetic cosmological transients. Long GRBs are usually associated with Type Ib/c supernovae (SNe), and we refer to them as GRB-SNe. Since the associated SN for a given GRB is observed only at low redshift, a possible selection effect exists when we consider intrinsically faint sources that cannot be observed at high redshift. Thus, it is important to explore the possible relationships between GRB and SN parameters after these have been corrected for astrophysical biases due to the instrumental selection effects and redshift evolution of the variables involved. So far, only GRB prompt emission properties have been checked against the SN Ib/c properties without considering the afterglow (AG). This work investigates the existence of relationships among GRBs’ prompt and AG and associated SN properties. We investigate 91 bidimensional correlations among the SN and GRB observables before and after their correction for selection biases and evolutionary effects. As a result of this investigation, we find hints of a new correlation with a Pearson correlation coefficient >0.50 and a probability of being drawn by chance <0.05. This correlation is between the luminosity at the end of the GRB optical plateau emission and the rest-frame peak time of the SN. According to this relation, the brightest optical plateaus are accompanied by the largest peak times. This correlation is corrected for selection biases and redshift evolution and may provide new constraints for the astrophysical models associated with the GRB-SN connection.

79 ASTRONOMY AND ASTROPHYSICS↗

THE NEW ONLINE METADATA EDITOR FOR GENERATING STRUCTURED METADATA

Nobody is better suited to “describe” data than the scientist who created it. This “description” about a data is called Metadata. In general terms, Metadata represents the who, what, when, where, why and how of the dataset [1]. eXtensible Markup Language (XML) is the preferred output format for metadata, as it makes it portable and, more importantly, suitable for system discoverability. The newly developed ORNL Metadata Editor (OME) is a Web-based tool that allows users to create and maintain XML files containing key information, or metadata, about the research. Metadata include information about the specific projects, parameters, time periods, and locations associated with the data. Such information helps put the research findings in context. In addition, the metadata produced using OME will allow other researchers to find these data via Metadata clearinghouses like Mercury [2][4]. OME is part of ORNL’s Mercury software fleet [2][3]. It was jointly developed to support projects funded by the United States Geological Survey (USGS), U.S. Department of Energy (DOE), National Aeronautics and Space Administration (NASA) and National Oceanic and Atmospheric Administration (NOAA). OME’s architecture provides a customizable interface to support project-specific requirements. Using this new architecture, the ORNL team developed OME instances for USGS’s Core Science Analytics, Synthesis, and Libraries (CSAS&L), DOE’s Next Generation Ecosystem Experiments (NGEE) and Atmospheric Radiation Measurement (ARM) Program, and the international Surface Ocean Carbon Dioxide ATlas (SOCAT).Researchers simply use the ORNL Metadata Editor to enter relevant metadata into a Web-based form. From the information on the form, the Metadata Editor can create an XML file on the server that the editor is installed or to the user’s personal computer. Researchers can also use the ORNL Metadata Editor to modify existing XML metadata files.As an example, an NGEE Arctic scientist use OME to register their datasets to the NGEE data archive and allows the NGEE archive to publish these datasets via a data search portal (http://ngee.ornl.gov/data). These highly descriptive metadata created using OME allows the Archive to enable advanced data search options using keyword, geo-spatial, temporal and ontology filters. Similarly, ARM OME allows scientists or principal investigators (PIs) to submit their data products to the ARM data archive.How would OME help Big Data Centers like the Oak Ridge National Laboratory Distributed Active Archive Center (ORNL DAAC)?The ORNL DAAC is one of NASA’s Earth Observing System Data and Information System (EOSDIS) data centers managed by the Earth Science Data and Information System (ESDIS) Project. The ORNL DAAC archives data produced by NASA's Terrestrial Ecology Program. The DAAC provides data and information relevant to biogeochemical dynamics, ecological data, and environmental processes, critical for understanding the dynamics relating to the biological, geological, and chemical components of the Earth's environment. Typically data produced, archived and analyzed is at a scale of multiple petabytes, which makes the discoverability of the data very challenging. Without proper metadata associated with the data, it is difficult to find the data you are looking for and equally difficult to use and understand the data.OME will allow data centers like the NGEE and ORNL DAAC to produce meaningful, high quality, standards-based, descriptive information about their data products in-turn helping with the data discoverability and interoperability. Useful Links:USGS OME: http://mercury.ornl.gov/OME/NGEE OME: http://ngee-arctic.ornl.gov/ngeemetadata/ARM OME: http://archive2.ornl.gov/armome/Contact: Ranjeet Devarakonda (devarakondar@ornl.gov)References:[1] Federal Geographic Data Committee. Content standard for digital geospatial metadata. Federal Geographic Data Committee, 1998.[2] Devarakonda, Ranjeet, et al. "Mercury: reusable metadata management, data discovery and access system." Earth Science Informatics 3.1-2 (2010): 87-94.[3] Wilson, B. E., Palanisamy, G., Devarakonda, R., Rhyne, B. T., Lindsley, C., & Green, J. (2010). Mercury Toolset for Spatiotemporal Metadata.[4] Pouchard, L. C., Branstetter, M. L., Cook, R. B., Devarakonda, R., Green, J., Palanisamy, G., ... & Noy, N. F. (2013). A Linked Science investigation: enhancing climate change data discovery with semantic technologies. Earth science informatics, 6(3), 175-185.

FGDC CSDGM↗

LiDAR-Aided Interior Orientation Parameters Refinement Strategy for Consumer-Grade Cameras Onboard UAV Remote Sensing Systems

Unmanned aerial vehicles (UAVs) are quickly emerging as a popular platform for 3D reconstruction/modeling in various applications such as precision agriculture, coastal monitoring, and emergency management. For such applications, LiDAR and frame cameras are the two most commonly used sensors for 3D mapping of the object space. For example, point clouds for the area of interest can be directly derived from LiDAR sensors onboard UAVs equipped with integrated global navigation satellite systems and inertial navigation systems (GNSS/INS). Imagery-based mapping, on the other hand, is considered to be a cost-effective and practical option and is often conducted by generating point clouds and orthophotos using structure from motion (SfM) techniques. Mapping with photogrammetric approaches requires accurate camera interior orientation parameters (IOPs), especially when direct georeferencing is utilized. Most state-of-the-art approaches for determining/refining camera IOPs depend on ground control points (GCPs). However, establishing GCPs is expensive and labor-intensive, and more importantly, the distribution and number of GCPs are usually less than optimal to provide adequate control for determining and/or refining camera IOPs. Moreover, consumer-grade cameras with unstable IOPs have been widely used for mapping applications. Therefore, in such scenarios, where frequent camera calibration or IOP refinement is required, GCP-based approaches are impractical. To eliminate the need for GCPs, this study uses LiDAR data as a reference surface to perform in situ refinement of camera IOPs. The proposed refinement strategy is conducted in three main steps. An image-based sparse point cloud is first generated via a GNSS/INS-assisted SfM strategy. Then, LiDAR points corresponding to the resultant image-based sparse point cloud are identified through an iterative plane fitting approach and are referred to as LiDAR control points (LCPs). Finally, IOPs of the utilized camera are refined through a GNSS/INS-assisted bundle adjustment procedure using LCPs. Seven datasets over two study sites with a variety of geomorphic features are used to evaluate the performance of the developed strategy. The results illustrate the ability of the proposed approach to achieve an object space absolute accuracy of 3–5 cm (i.e., 5–10 times the ground sampling distance) at a 41 m flying height.

47 OTHER INSTRUMENTATION↗

Los Alamos National Laboratory standard nuclear material container

The shut down of United States (U.S.) nuclear-weapons production activities in the early 1990s left large quantities of nuclear materials throughout the U.S. Department of Energy (DOE) complex in forms not intended for long-term storage. In May 1994, the Defense Nuclear Facilities Safety Board (DNFSB) issued Recommendation 94-1, which called for the stabilization and disposition of 'thousands of containers of plutonium-bearing liquids and solids' in the DOE complex, including LANL in the nuclear-weapons-manufacturing pipeline when manufacturing ended. This resulted in the development of the 3013 standard with container requirements for long term storage (up to 50 years). A follow on was the Criteria For Interim Storage of Plutonium Bearing Materials, Charles B. Curtis, in 1996 to address storage other than the 3013 standard for shorter time frames. In January 2000, the DNFSB issued Recommendation 2000-1, which stated the need for LANL to repackage 'about one ton of plutonium metal and oxide,' declared excess to Defense Program (DP) needs. The DNFSB recommended that LANL 'stabilize and seal within welded containers with an inert atmosphere the plutonium oxides ... which are not yet in states conforming to the long-term storage envisaged by DOE-STD-3013,' and that they '... enclose existing and newly-generated legacy plutonium metal in sealed containers with an inert atmosphere,' and 'remediate and/or safely store the various residues.' Recommendation 2000-1, while adding to the number of items needing remediation, also reiterated the need to address remaining items from 1994-1 in a timely fashion. Since timetables slipped, the DNFSB recommended that the Complex 'prioritize and schedule tasks according to the consideration of risks.' In March 2005, the DNFSB issued Recommendation 2005-1. This recommendation addresses the need for a consistent set of criteria across the DOE complex for the interim storage of nuclear material packaged outside an engineered barrier. The Department of Energy (DOE) approved and issued on March 7, 2008, DOE M 441.1-1, Nuclear Material Packaging Manual [hereafter referred to as Manual] to address this recommendation, and a Prioritization Methodology as a complex-wide requirement for the packaging of nuclear material outside an engineered barrier. The Manual establishes 'technically justified criteria' for packages in order to ensure safe interim storage and handling outside an engineered barrier. The Prioritization Methodology establishes a risk-based procedure for identifying the order to repackage that would most efficiently reduce the overall risk. It is a logical extension of the work performed to meet the two earlier DNFSB recommendations to include all materials stored outside of engineered barriers, i.e., not just excess materials. LANL will continue to work all aspects of a comprehensive Implementation Plan to d monstrate all aspects of compliance with the Manual. Assessment of materials in nonstandard containers utilizing a risk based approach, repackaging up to 400 containers/year; activities include reprocessing of items to allow container consolidation and subsequent increase in vault capacity. Continued efforts in establishing and implementing a Surveillance and Maintenance Program for current Hagans and for the NG SNMCSs supported by a database for packaging and surveillance. Elastomer aging studies for the NG SNMCs will continue to justify extending the design life well beyond the currently specified five years. First production with containers available for use anticipated in June 2010. LANL will continue to define schedule and resources to meet these objectives.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Proteogenomic strategies for identification of aberrant cancer peptides using large-scale Next Generation Sequencing data

Cancer is driven by the acquisition of somatic DNA lesions. Distinguishing the early driver mutations from subsequent passenger mutations is key to molecular sub-typing of cancers, and the discovery of novel biomarkers. The availability of genomics technologies (mainly wholegenome and exome sequencing, and transcript sampling via RNA-seq, collectively referred to as NGS) have fueled recent studies on somatic mutation discovery. However, the vision is challenged by the complexity, redundancy, and errors in genomic data, and the difficulty of investigating the proteome using only genomic approaches. Recently, combination of proteomic and genomic technologies are increasingly employed. However, the complexity and redundancy of NGS data remains a challenge for proteogenomics, and various trade-offs must be made to allow for the searches to take place. This paperprovides a discussion of two such trade-offs, relating to large database search, and FDR calculations, and their implication to cancer proteogenomics. Moreover, it extends and develops the idea of a unified genomic variant database that can be searched by any mass spectrometry sample. A total of 879 BAM files downloaded from TCGA repository were used to create a 4.34 GB unified FASTA database which contained 2,787,062 novel splice junctions, 38,464 deletions, 1105 insertions, and 182,302 substitutions. Proteomic data from a single ovarian carcinoma sample (439,858 spectra) was searched against the database. By applying the most conservative FDR measure, we have identified 524 novel peptides and 65,578 known peptides at 1% FDR threshold. The novel peptides include interesting examples of doubly mutated peptides, frame-shifts, and non-sample-recruited mutations, which emphasize the strength of our approach.

59 BASIC BIOLOGICAL SCIENCES↗

Purposes, paradigms and pressure groups: Accountability and sustainability in EU environmental assessment, 1985-2010

Twenty five years since the introduction of the European Union (EU) environmental impact assessment (EIA) Directive in 1985 this paper reflects on the extent to which environmental assessment (EA) processes, over the course of their evolution over the last 25 years in the EU, have provided a platform for enhancing accountability and sustainability. Surprisingly-in the context of legal mandates for EA-there is little reference in the EA literature explicitly to the literature on accountability and the role EA may play in this increasingly important aspect of governance. The paper explores EA implementation principally from an environmentalist perspective and particularly the way in which NGOs and other advocates for the environment in the UK and EU have used the EA legislation as a lever for increasing democratic, corporate and professional accountability of proponents and decision-makers alike. From an a historical analysis, including two historical EIA case studies and two contemporary SEA case studies, it becomes clear that EA has had an important role to play-at the legislative level in providing the requirements for accountability, and at the implementation level as the lever that can be used to hold individuals, organisations and authorities to account for their actions. The relationship with the shift to sustainability is a close one, since sustainable development demands greater public involvement in decision-making and greater accountability of executive decisions to the public. The lessons from this analysis allow the development of a nascent policy-oriented theory regarding EA's role in accountability, which provides a framework for a distinctive new area of EA research and policy analysis. Moreover, an accountability perspective on EA could help re-frame EA for policy makers from being purely an informational and procedural instrument to one which promotes better accountability and sustainability simultaneously. - Highlights: Black-Right-Pointing-Pointer Little attention in the literature to environmental assessment (EA) and accountability. Black-Right-Pointing-Pointer Evolution of EA in the EU influenced by shifting policy paradigms and demands for accountability. Black-Right-Pointing-Pointer EIA and SEA, as formal procedures, can provide platforms for accountability. Black-Right-Pointing-Pointer Four case studies illustrate how NGOs and others have used EA to further accountability. Black-Right-Pointing-Pointer A policy-oriented theory provides a basis for considering future evolution of EA in the EU.

54 ENVIRONMENTAL SCIENCES↗