Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reactor physics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Demonstration of Emitted-Neutron Computed Tomography to Count Fuel Pins

In this paper, we report demonstration of emitted-neutron computed tomography using fast fission neutrons to infer the geometry of sources of special nuclear material (SNM) such as fuel pins. In a proof-of-concept measurement at the Idaho National Laboratory’s (INL’s) Zero Power Physics Reactor (ZPPR) facility, an array of unirradiated Pu MOX fuel rodlets in a soup can were imaged, and a bias defect consisting of a single rodlet containing Pu replaced by one containing depleted uranium (DU) was detected. The imaging system employed in the demonstration is based on a newly constructed array of pixelated neutron detectors that are suitable for arrangement in a close-packed imaging array and whose active volume consists of liquid scintillator EJ-309 which allows neutron-gamma discrimination via pulse shape to enable pure fast-neutron imaging. The imaging array was used along with a radial collimator aperture in order to perform high quality fast-neutron imaging where tomographic reconstruction of slices through an object resolve neutron sources similar in dimension to a fuel pellet, or about 1 cm. Measurements were performed at Oak Ridge National Laboratory (ORNL) with neutron sources in addition to those performed at the INL’s ZPPR facility with Pu MOX fuel rodlets. An analogous capability to detect single-pin defects in spent fuel assemblies would be desirable, such as for safeguards verification measurements of spent fuel assemblies just prior to transferring them from the spent fuel cooling pool to long term dry cask storage. This paper describes the design and construction of the present imager, characterization measurements with neutron sources at ORNL, measurements with SNM at INL’s ZPPR facility, and feasibility of building an analogous imager for spent fuel measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast-neutron coded-aperture imaging of special nuclear material configurations

In the past year, a prototype fast-neutron coded-aperture imager has been developed that has sufficient efficiency and resolution to make the counting of warheads for possible future treaty confirmation scenarios via their fission-neutron emissions practical. The imager is constructed from custom-built pixelated liquid scintillator detectors. The liquid scintillator detectors enable neutron-gamma discrimination via pulse shape, and the pixelated construction enables a sufficient number of pixels for imaging in a compact detector with a manageable number of channels of readout electronics. The imager has been used to image neutron sources at ORNL, special nuclear material (SNM) sources at the Idaho National Laboratory (INL) Zero Power Physics Reactor (ZPPR) facility, and neutron source and shielding configurations at Sandia National Laboratories. This paper reports on the design and construction of the imager, characterization measurements with neutron sources at ORNL, and measurements with SNM at the INL ZPPR facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pre-Processing of Cross-Sections Using Dimensionality Reduction Techniques

Reactor physics codes rely on cross-section data to determine, for example, flux profiles or burn-up calculations. This data contains cross section values for different neutron-atom interactions (e.g., absorption, fission and scattering) for a large number of isotopes as function of energy and it is tabulated for a specific set of parameters (e.g., moderator temperature, fuel temperature, moderator density). In order to perform such neutronic calculations, the amount of this data that needs to be stored is very large due to the high number of isotopes and many tabulation points are needed. This data needs to be retrieved at each time iteration of the code from the machine memory which negatively affects the computational time of the code itself.

99 GENERAL AND MISCELLANEOUS↗

Demonstration of Emitted-Neutron Computed Tomography to Count Fuel Pins

In this paper, we report demonstration of emitted-neutron computed tomography using fast fission neutrons to infer the geometry of sources of special nuclear material (SNM) such as fuel pins. In a proof-of-concept measurement at the Idaho National Laboratory s (INL s) Zero Power Physics Reactor (ZPPR) facility, an array of unirradiated Pu MOX fuel rodlets in a soup can were imaged, and a bias defect consisting of a single rodlet containing Pu replaced by one containing depleted uranium (DU) was detected. The imaging system employed in the demonstration is based on a newly constructed array of pixelated neutron detectors that are suitable for arrangement in a close-packed imaging array and whose active volume consists of liquid scintillator EJ-309 which allows neutron-gamma discrimination via pulse shape to enable pure fast-neutron imaging. The imaging array was used along with a radial collimator aperture in order to perform high quality fast-neutron imaging where tomographic reconstruction of slices through an object resolve neutron sources similar in dimension to a fuel pellet, or about 1 cm. Measurements were performed at Oak Ridge National Laboratory (ORNL) with neutron sources in addition to those performed at the INL s ZPPR facility with Pu MOX fuel rodlets. An analogous capability to detect single-pin defects in spent fuel assemblies would be desirable, such as for safeguards verification measurements of spent fuel assemblies just prior to transferring them from the spent fuel cooling pool to long term dry cask storage. This paper describes the design and construction of the present imager, characterization measurements with neutron sources at ORNL, measurements with SNM at INL s ZPPR facility, and feasibility of building an analogous imager for spent fuel measurements.

Hausladen, Paul↗

Fast neutron coded-aperture imaging of special nuclear material configurations

In the past year, a prototype fast-neutron coded-aperture imager has been developed that has sufficient efficiency and resolution to make the counting of warheads for possible future treaty confirmation scenarios via their fission-neutron emissions practical. The imager is constructed from custom-built pixelated liquid scintillator detectors. The liquid scintillator detectors enable neutron-gamma discrimination via pulse shape, and the pixelated construction enables a sufficient number of pixels for imaging in a compact detector with a manageable number of channels of readout electronics. The imager has been used to image neutron sources at ORNL, special nuclear material (SNM) sources at the Idaho National Laboratory (INL) Zero Power Physics Reactor (ZPPR) facility, and neutron source and shielding configurations at Sandia National Laboratories. This paper reports on the design and construction of the imager, characterization measurements with neutron sources at ORNL, and measurements with SNM at the INL ZPPR facility.

Hausladen, Paul↗

Overview of Scale 6.2

SCALE is an industry-leading suite of tools for nuclear systems modeling and simulation that provides comprehensive, verified and validated, user-friendly capabilities for criticality safety, reactor physics, radiation shielding, and sensitivity and uncertainty analysis. For more than 30 years, regulators, licensees, and research institutions around the world have used SCALE for nuclear safety analysis and design. SCALE provides a plug-and-play framework that includes three deterministic and three Monte Carlo radiation transport solvers that are selected based on the desired solution. SCALE includes the latest nuclear data libraries for continuous-energy and multigroup radiation transport as well as activation, depletion, and decay calculations. SCALE s graphical user interfaces assist with accurate system modeling, visualization, and convenient access to desired results. SCALE 6.2 provides several new capabilities and significant improvements in many existing features, especially with expanded CE Monte Carlo capabilities for criticality safety, shielding, depletion, and sensitivity and uncertainty analysis. A brief overview of SCALE capabilities is provided with emphasis on new features for SCALE 6.2.

97 MATHEMATICS AND COMPUTING↗

The SCALE Verified, Archived Library of Inputs and Data - VALID

The Verified, Archived Library of Inputs and Data (VALID) at ORNL contains high quality, independently reviewed models and results that improve confidence in analysis. VALID is developed and maintained according to a procedure of the SCALE quality assurance (QA) plan. This paper reviews the origins of the procedure and its intended purpose, the philosophy of the procedure, some highlights of its implementation, and the future of the procedure and associated VALID library. The original focus of the procedure was the generation of high-quality models that could be archived at ORNL and applied to many studies. The review process associated with model generation minimized the chances of errors in these archived models. Subsequently, the scope of the library and procedure was expanded to provide high quality, reviewed sensitivity data files for deployment through the International Handbook of Evaluated Criticality Safety Benchmark Experiments (IHECSBE). Sensitivity data files for approximately 400 such models are currently available. The VALID procedure and library continue fulfilling these multiple roles. The VALID procedure is based on the quality assurance principles of ISO 9001 and nuclear safety analysis. Some of these key concepts include independent generation and review of information, generation and review by qualified individuals, use of appropriate references for design data and documentation, and retrievability of the models, results, and documentation associated with entries in the library. Some highlights of the detailed procedure are discussed to provide background on its implementation and to indicate limitations of data extracted from VALID for use by the broader community. Specifically, external users of data generated within VALID must take responsibility for ensuring that the files are used within the QA framework of their organization and that use is appropriate. The future plans for the VALID library include expansion to include additional experiments from the IHECSBE, to include experiments from areas beyond criticality safety, such as reactor physics and shielding, and to include application models. In the future, external SCALE users may also obtain qualification under the VALID procedure and be involved in expanding the library. The VALID library provides a pathway for the criticality safety community to leverage modeling and analysis expertise at ORNL.

97 MATHEMATICS AND COMPUTING↗

Development of Fuel Shuffling Module for PHISICS

PHISICS (Parallel and Highly Innovative Simulation for the INL Code System) [4] code toolkit has been in development at the Idaho National Laboratory. This package is intended to provide a modern analysis tool for reactor physics investigation. It is designed with the mindset to maximize accuracy for a given availability of computational resources and to give state of the art tools to the modern nuclear engineer. This is obtained by implementing several different algorithms and meshing approaches among which the user will be able to choose, in order to optimize his computational resources and accuracy needs. The software is completely modular in order to simplify the independent development of modules by different teams and future maintenance. The package is coupled with the thermo-hydraulic code RELAP5-3D [3]. In the following the structure of the different PHISICS modules is briefly recalled, focusing on the new shuffling module (SHUFFLE), object of this paper.

97 MATHEMATICS AND COMPUTING↗

Integral Benchmark Data for Nuclear Data Testing Through the ICSBEP & IRPhEP

The status of the International Criticality Safety Benchmark Evaluation Project (ICSBEP) and International Reactor Physics Experiment Evaluation Project (IRPhEP) was last discussed directly with the nuclear data community at ND2007. Since ND2007, integral benchmark data that are available for nuclear data testing have increased significantly. The status of the ICSBEP and the IRPhEP is discussed and selected benchmark configurations that have been added to the ICSBEP and IRPhEP Handbooks since ND2007 are highlighted.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Role of Experiment Covariance in Cross Section Adjustments

This paper is dedicated to the memory of R. D. McKnight, which gave a seminal contribution in establishing methodology and rigorous approach in the evaluation of the covariance of reactor physics integral experiments. His original assessment of the ZPPR experiment uncertainties and correlations has made nuclear data adjustments, based on these experiments, much more robust and reliable. In the present paper it has been shown with some numerical examples the actual impact on an adjustment of accounting for or neglecting such correlations.

97 MATHEMATICS AND COMPUTING↗

Enhancements in Continuous-Energy Monte Carlo Capabilities for SCALE 6.2

SCALE is a widely used suite of tools for nuclear systems modeling and simulation that provides comprehensive, verified and validated, user-friendly capabilities for criticality safety, reactor physics, radiation shielding, and sensitivity and uncertainty analysis. For more than 30 years, regulators, industry, and research institutions around the world have used SCALE for nuclear safety analysis and design. SCALE provides a plug-and-play framework that includes three deterministic and three Monte Carlo radiation transport solvers that are selected based on the desired solution. SCALE includes the latest nuclear data libraries for continuous-energy and multigroup radiation transport as well as activation, depletion, and decay calculations. SCALE s graphical user interfaces assist with accurate system modeling, visualization, and convenient access to desired results. SCALE 6.2 provides several new capabilities and significant improvements in many existing features, especially with expanded continuous-energy Monte Carlo capabilities for criticality safety, shielding, depletion, sensitivity and uncertainty analysis, and improved fidelity in nuclear data libraries. A brief overview of SCALE capabilities is provided with emphasis on new features for SCALE 6.2.

Continuous-Energy↗

Modernization Enhancements in SCALE 6.2

SCALE is a widely used suite of tools for nuclear systems modeling and simulation that provides comprehensive, verified and validated, user-friendly capabilities for criticality safety, reactor physics, radiation shielding, and sensitivity and uncertainty analysis. For more than 30 years, regulators, industry, and research institutions around the world have used SCALE for nuclear safety analysis and design. However, the underlying architecture of SCALE is based on a 40-year old design with dozens of independent functional modules and control programs, primarily implemented in the Fortran programming language, with extensive use of customized intermediate files to control the logical flow of the analysis. Data are passed between individual computational codes using custom binary files that are read from and written to the hard disk. The SCALE modernization plan provides a progression towards SCALE 7, which will provide an object-oriented parallel-enabled software infrastructure with state-of-the-art methods implemented as reusable components. This paper provides a brief overview of the goals of SCALE modernization and details some modernized features available with SCALE 6.2.

modern↗

Fast-Neutron Multiplicity Counter for the Detection of Diversion Scenarios

We demonstrated the application of a fast-neutron multiplicity counter (FNMC) to detect small variations in an assembly of uranium-oxide pins. The current version of the FNMC includes eight liquid organic scintillators (EJ-309 7.62 cm diameter x 7.62 cm) and eight crystal organic scintillators (stilbene 5.08 cm diameter x 5.08 cm) in a checkerboard assembly. We measured time-correlated fast neutrons, emitted by an assembly of 32 uranium-oxide pins, using two AmLi sources to induce fissions in the sample. Each pin is a cylinder of approximately 1 cm diameter and 10 cm length, with a mass of 75.52 g and 16.37 wt% enrichment. We removed up to 16 pins from a sample consisting of 32 pins, and determined the minimum number of pins that resulted in a statistically significant decrease of neutron coincidence counts. All the measurements were performed at the Zero Power Physics Reactor facility of Idaho National Laboratory. We found that a diversion of the four innermost pins could be detected by the system in 5 minutes. The detection of time-correlated neutrons requires their discrimination from gamma-ray events. This is an especially challenging task when measuring uranium isotopes, because of the intense gamma-ray flux generated by the radioactive decay of uranium daughters. We will describe the on-board pulse shape discrimination and post processing techniques that we applied to effectively distinguish neutrons from gamma-rays. Fast-neutron measurements have several potential advantages compared to thermal and epithermal neutron counters, the most important being a shorter die-away time and therefore reduced spurious coincidences due to accidental counts. This advantage may result in a higher sensitivity in timely detecting diversion of nuclear material from peaceful uses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast-neutron Multiplicity Counter for Passive and Active Measurements of Special Nuclear Material

We developed a fast-neutron multiplicity counter (FNMC) based on organic scintillators (liquid and stilbene). The system is able to detect correlated photon and neutron multiplets emitted by fission reactions. We tested the system both in passive and active operation mode, and present the results of the experiments, both carried out at the Zero Power Physics Reactor of Idaho National Laboratory. The system was operated in coincidence mode (with a gate time of 50 nanoseconds) and two calibration-based approaches were used to estimate the 240Pu effective (240Pueff) and 235U mass of the samples. In passive mode, we assayed two types of plutonium metal plates, i.e. PAHN and PANN, with a 240Pueff mass of 4.7 g and 25.05 g per plate, respectively. The 239Pu mass percentage was 74% for the PAHN and 95% for the PANN series. We measured neutrons emitted in coincidence by several plate assemblies, having an overall 240Pueff mass in the 4.7 g to 500 g range. In active mode, we characterized several uranium samples. We used two AmLi sources (~50000 neutrons emitted per second) to induce fission in the samples. The first six measured samples were certified reference materials (CRM, set 149), having a constant enrichment, i.e. 93.2 wt%, and mass in the range between 0.5 and 4 kg. Additionally, we assayed three CRM-146 samples, with constant total mass of 500 g and an enrichment of 20.1 wt%, 52.8 wt% and 93.2 wt%. In both configurations, the system succeeded in estimating the fissile mass of an unknown sample with a statistical uncertainty lower than 1% (4-minute assay) and 7% (10-minute assay), in passive and active mode, respectively. In passive mode, the statistical uncertainty is lower than the one achieved by standard 3He counters for plutonium metal samples of similar mass. The difference between the estimated and the declared 240Pueff mass, i.e., the bias error, measured by the fast neutron multiplicity counter was consistently lower compared to the bias error of a standard thermal system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling of the TREAT M8 Calibration Series Measurements using MAMMOTH

This presentation provides an overview of the modeling efforts performed in to validate the MAMMOTH multi-physics reactor analysis application using historical TREAT data. These data come from the M8 series of calibration measurements, which was the last series performed before TREAT was shut down in 1994. The data applied in this work include an experiment flux profile and low level steady state power coupling factors for both flux wires and fuel pins. MAMMOTH was able to obtain reasonable results for all cases with the exception of the H91-8-1 flux wire, the only flux wire containing highly-enriched uranium. The feasibility of performing similar simulations of the calibration series fuel pins was demonstrated with the flux wire calculations, and will be performed in future work.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

U-10Mo Conversion Burnup Benchmarking Activities for Full-Size LEU Fuel Plates

Validation benchmark experiments for low-enriched uranium (LEU) U-Mo fuel systems are currently being developed from existing experiments irradiated in the Advanced Test Reactor. (ATR) and ATR Critical Facility (ATRC). The experiments chosen include the ATR Full size plate In center Flux trap Position (AFIP-7) experiment and the Ki-Jang Research Reactor Lead Test Assembly (KJRR-LTA) located in the Northeast Flux Trap. Each experiment was modeled using a high-fidelity three-dimensional Monte Carlo code with depletion capabilities. A description of the validation experiments will be provided as well as comparison to post irradiation examination results for the AFIP-7 experiment. The PIE results for the AFIP-7 experiment have demonstrated good agreement with analytical models. Due to the complex nature in of the ATR, modeling simplifications to support benchmark activities using lower fidelity reactor physics software. A discussion of the analytical bias associated with modeling simplifications will also be provided.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simulation of Thermal Spectrum MSR using PROTEUS

In recent years, there has been renewed interest in Molten Salter Reactors (MSRs) for their potential advantages compared to reactors that rely on solid fuel. Given the current interest for MSRs, it is a good opportunity to demonstrate that the advanced tools developed in the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program are useful for modeling MSRs. In addition, one objective of the program is to develop modeling and simulation capabilities to predict the performance and safety of all types of advanced nuclear reactor. For this study, PROTEUS [1], the primary reactor physics tool within the program, was assessed and used to model one of the preliminary core designs provided by ThorCon, one of the leading MSR companies from industry. The focus of this first step in the modeling and simulation work is to predict the core design’s steady state performance.

Fei, T.↗

UMo Benchmark Experiment Data Needed to Support Computational and Nuclear Data Validation

Currently there are almost no benchmark experiment data available directly supporting neutronics modeling and simulation of ~20 wt.% 235U, UMo fuel contained within the Organisation for Co-operation and Development Nuclear Energy Agency (OECD NEA) international benchmark handbooks from the International Criticality Safety Benchmark Evaluation Project (ICSBEP) and International Reactor Physics Experiment Evaluation Project (IRPhEP). The benchmarks within these two handbooks represent the international standards used to support computational and nuclear data validation. Recent activities in nuclear data development supporting new neutronics thermal scattering cross sections for UMo fuel indicate the necessity to provide quality benchmark experiment data that can be utilized to support their validation and development. Preparation of high-integrity neutronics benchmarks from UMo experimental data will ensure proper integral testing of these cross sections, as well as serve to support computational validation of contemporary modeling and simulation software.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗