Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Measuring very low radiation doses in PTFE for nuclear forensic enrichment reconstruction

Every country that has made nuclear weapons has used uranium enrichment to do so. Despite the centrality of this technology to international security, there is still no reliable physical marker of past enrichment in the open literature that can be used to perform forensic verification of historically produced weapons on gas centrifuges. We show that the extremely low radioactivity from uranium alpha emissions during enrichment leaves detectable and irreversible calorimetric signatures in the common enrichment gasket material PTFE, allowing for historical reconstruction of past enrichment activities at a sensitivity better than one weapon’s quantity of highly enriched uranium. Fast scanning calorimetry also enables the measurement of recrystallization enthalpies of sequentially microtomed slices, confirming the magnitude and the type of radiation exposure while also providing detection of tampering and a method for analyzing field samples useful for treaty verification. Furthermore, this work opens the door for common items to be turned into precise dosimeters to detect the past presence of radioactivity, nuclear materials, and related activities with high confidence.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Large-misalignment mechanism for the formation of compact axion structures: Signatures from the QCD axion to fuzzy dark matter

Axions are some of the best motivated particles beyond the Standard Model. We show how the attractive self-interactions of dark matter (DM) axions over a broad range of masses, from 10 –22 eV to 10 7 GeV, can lead to nongravitational growth of density fluctuations and the formation of bound objects. This structure formation enhancement is driven by parametric resonance when the initial field misalignment is large, and it affects axion density perturbations on length scales of order the Hubble horizon when the axion field starts oscillating, deep inside the radiation-dominated era. This effect can turn an otherwise nearly scale-invariant spectrum of adiabatic perturbations into one that has a spike at the aforementioned scales, producing objects ranging from dense DM halos to scalar-field configurations such as solitons and oscillons. We call this class of cosmological scenarios for axion DM production “the large-misalignment mechanism.” In this work, we explore observational consequences of this mechanism for axions with masses up to 10 eV. For axions heavier than 10 –5 eV, the compact axion halos are numerous enough to significantly impact Earth-bound direct detection experiments, yielding intermittent but coherent signals with repetition rates exceeding one per decade and crossing times less than a day. These episodic increases in the axion density and kinematic coherence suggest new approaches for axion DM searches, including for the QCD axion. Dense structures made up of axions from 10 –22 eV to 10 –5 eV are detectable through gravitational lensing searches, and their gravitational interactions can also perturb baryonic structures and alter star formation. At very high misalignment amplitudes, the axion field can undergo self-interaction-induced implosions long before matter-radiation equality, producing potentially-detectable low-frequency stochastic gravitational waves.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Overview of a Methodology for Calculating the A Priori Scan Minimum Detectable Concentration for Post-Processed Radiological Surveys (Final Report) (Rev.1)

Increased continuous data collection using automated data loggers and autonomous radiological survey devices or vehicles has introduced a need for corresponding guidance and statistical techniques for data that are collected without surveyor vigilance. This report presents a method for calculating the a priori scan minimum detectable concentrations (MDCs) for surveys performed without vigilance similar to methods described in the Multi-Agency Radiation Survey and Site Investigation Manual, NUREG-1507, and NUREG/CR-6364. A priori scan MDCs are calculated during survey planning to ensure that survey parameters (e.g., scanning speed, scanning altitude, detector geometry) will lead to collecting data in which potentially contaminated areas can be detected when data are processed after the survey, within acceptable statistical error probabilities.

54 ENVIRONMENTAL SCIENCES↗

A laser powder bed fusion system for operando synchrotron x-ray imaging and correlative diagnostic experiments at the Stanford Synchrotron Radiation Lightsource

Laser powder bed fusion (LPBF) is a highly dynamic multi-physics process used for the additive manufacturing (AM) of metal components. Improving process understanding and validating predictive computational models require high-fidelity diagnostics capable of capturing data in challenging environments. Synchrotron x-ray techniques play a vital role in the validation process as they are the only in situ diagnostic capable of imaging sub-surface melt pool dynamics and microstructure evolution during LPBF-AM. In this article, a laboratory scale system designed to mimic LPBF process conditions while operating at a synchrotron facility is described. The system is implemented with process accurate atmospheric conditions, including an air knife for active vapor plume removal. Significantly, the chamber also incorporates a diagnostic sensor suite that monitors emitted optical, acoustic, and electronic signals during laser processing with coincident x-ray imaging. The addition of the sensor suite enables validation of these industrially compatible single point sensors by detecting pore formation and spatter events and directly correlating the events with changes in the detected signal. Experiments in the Ti–6Al–4V alloy performed at the Stanford Synchrotron Radiation Lightsource using the system are detailed with sufficient sampling rates to probe melt pool dynamics. X-ray imaging captures melt pool dynamics at frame rates of 20 kHz with a 2 µm pixel resolution, and the coincident diagnostic sensor data are recorded at 470 kHz. Furthermore, this work shows that the current system enables the in situ detection of defects during the LPBF process and permits direct correlation of diagnostic signatures at the exact time of defect formation.

36 MATERIALS SCIENCE↗

Correlative nano-imaging of metals and proteins in primary neurons by synchrotron X-ray fluorescence and STED super resolution microscopy: Experimental validation

It is becoming increasingly clear that biological metals such as iron, copper or zinc are involved in synaptic functions, and in particular in the mechanisms of synaptogenesis and subsequent plasticity. Understanding the role of metals on synaptic functions is a difficult challenge due to the very low concentration of these elements in neurons and to the submicrometer size of synaptic compartments. To address this challenge we have developed a correlative nano-imaging approach combining metal and protein detection. First, stimulated emission depletion (STED) microscopy, a super resolution optical microscopy technique, is applied to locate fluorescently labeled proteins. Then, synchrotron radiation induced X-ray fluorescence (SXRF) is performed on the same regions of interest, e.g. synaptic compartments. Here, we present here the principle scheme that allows this correlative nano-imaging and its experimental validation. We applied this correlative nano-imaging to the study of the physiological distribution of metals in synaptic compartments of primary rat hippocampal neurons. We thus compared the nanometric distribution of metals with that of synaptic proteins, such as PSD95 or cytoskeleton proteins. Compared to correlative imaging approaches currently used to characterize synaptic structures, such as electron microscopy correlated with optical fluorescence, our approach allows for ultra-sensitive detection of trace metals using highly focused synchrotron radiation beams. We provide proof-of-principle for correlative imaging of metals and proteins at the synaptic scale and discuss the present limitations and future developments in this area.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of trapped charge on the signal formation and detection efficiency for subsequent pulses in irradiated silicon sensors

Envisaged high energy physics experiments like the Future Circular Collider require unprecedented radiation hardness of the detectors, as well as short readout time due to high luminosity and occupancy. Silicon has proven to be extremely radiation hard. Sufficient signals can be recorded even at fluences close to 1 ∙ 1 0 16 n e q / cm 2 . Here, the signal formation was studied in silicon strip sensors, irradiated and annealed until the phenomenon of charge multiplication occurred. ATLAS12EC R0 mini sensors were tested by means of edge TCT measurements at temperatures around –20 °C. It was observed that the detection of subsequent signals separated up to several microseconds is altered by the charge trapped during the preceding pulses. The effects of trapped charge on the electrical configuration of a sensor are well known as a polarization or pumping effect in larger band-gap materials like diamond, but is often neglected for silicon at this relatively high temperature. The investigation of the effect created by trapped charges in silicon sensors using subsequent pulses allows to gain information on important parameters such as de-trapping times. Furthermore, it shows a severe impact on the sensor performance in a pile-up scenario. The irradiation fluence and hence the effective doping concentration, the temperature and the amount of initially created charge have a large impact on this phenomenon. The measurements presented help to characterize this phenomenon; particular attention was paid to the application point of view.

47 OTHER INSTRUMENTATION↗

Qubit-Based Detector For Dark Matter Search And Radiation Studies

One of the challenges in exploring promising novel materials for dark matter searches is the detection of sub-eV energy excitations from light-dark matter interaction with a target material. Dark matter interaction can excite sub-eV optical phonon modes in polar materials like sapphire. We plan to utilize superconducting qubits on a sapphire substrate to study their response to energy deposition into the superconducting film and the substrate by irradiating them with photons and particles and also generating phonons in the chip. A fraction of the incident energy is expected to break Cooper pairs in the superconductor, releasing quasiparticles. As the quasiparticles tunnel across the Josephson junction, the charge parity of the qubit changes. The parity switching rate is proportional to the quasiparticle density in the qubit superconductor film and can be measured using standard qubit readout protocol. This presentation describes our ongoing attempt to build such a prototype detector.

Khatiwada, Rakshya↗

Dual particle imaging: Applications in security and environmental imaging

Radiation imaging detectors have been applied in a variety of fields for detection, localization and characterization of radioactive sources. In this work, we describe a handheld detection system (H2DPI) that can simultaneously image neutrons and gamma rays, and reconstruct the energy spectra of the incident particles. This system was applied to the detection and characterization of a plutonium metal source in experiments performed at the National Criticality Experiments Research Center, where the 4.5 kg plutonium source was placed approximately 60 cm from the H2DPI. Neutron and gamma-ray images were measured that show good agreement with the known location of the source. Furthermore, the H2DPI was also used to measure the neutron spectrum, which shows the expected shape of a Watt fission spectrum, and the gamma-ray energy spectrum, which shows the energies common to plutonium metal. Finally, we describe the application of the H2DPI in augmented reality, whereby real-time neutron and gamma-ray imaging data can be streamed to the Microsoft HoloLens to allow the user to visualize the source locations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ligand assisted growth of perovskite single crystals with low defect density

A low defect density in metal halide perovskite single crystals is critical to achieve high performance optoelectronic devices. Here we show the reduction of defect density in perovskite single crystals grown by a ligand-assisted solution process with 3-(decyldimethylammonio)-propane-sulfonate inner salt (DPSI) as an additive. DPSI ligands anchoring with lead ions on perovskite crystal surfaces not only suppress nucleation in solution, but also regulate the addition of proper ions to the growing surface, which greatly enhances the crystal quality. The grown CH 3 NH 3 PbI 3 crystals show better crystallinity and a 23-fold smaller trap density of 7 × 10 10 cm -3 than the optimized control crystals. The enhanced material properties result in significantly suppressed ion migration and superior X-ray detection sensitivity of CH 3 NH 3 PbI 3 detectors of (2.6 ± 0.4) × 10 6 µC Gy -1 air cm -2 for 60 kVp X-ray and the lowest detectable dose rate reaches (5.0 ± 0.7) nGy s -1 , which enables reduced radiation dose to patients in medical X-ray diagnostics.

36 MATERIALS SCIENCE↗

Electron-ion recombination in composite interactions in liquid xenon

The response of liquid xenon to various types of ionizing radiation has been extensively studied theoretically and experimentally. Recent progress in direct detection dark matter experiments highlights the significance of composite events, where multiple particles interact with xenon simultaneously and generate overlapping ionization signatures. In these events, recombination of electrons and ions associated with different primary particles leads to additional suppression of the ionization signal, introducing a new source of uncertainty in dark matter searches and Migdal effect studies. We developed a model to estimate the recombination enhancement for overlapping low-energy particle interactions. This method, which has minimal dependence on xenon microphysics and is primarily driven by existing experimental data, yields predictions that are consistent with available measurements of composite interactions. Furthermore, we demonstrate that the model predictions are robust against xenon microphysics assumptions.

charge↗

Correlating gravitational wave and gamma-ray signals from primordial black holes

Asteroid-mass primordial black holes (PBHs) can explain the observed dark matter abundance while being consistent with the current indirect detection constraints. These PBHs can produce gamma-ray signals from Hawking radiation that are within the sensitivity of future measurements by the AMEGO and e-ASTROGAM experiments. PBHs which give rise to such observable gamma-ray signals have a cosmic origin from large primordial curvature fluctuations. There must then be a companion, stochastic gravitational wave (GW) background produced by the same curvature fluctuations. We demonstrate that the resulting GW signals will be well within the sensitivity of future detectors such as LISA, DECIGO, BBO, and the Einstein Telescope. The multimessenger signal from the observed gamma-rays and GWs will allow a precise measurement of the primordial curvature perturbation that produces the PBH. Indeed, so we argue that the resulting correlation between the two types of observations can provide a smoking-gun signal of PBHs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Architecture of the personnel protection systems for Spallation Neutron Source Second Target Station

The Oak Ridge National Laboratory (ORNL) is implementing a major upgrade to the Spallation Neutron Source (SNS) facility, encompassing the addition of the Second Target Station (STS). Preliminary design reviews have been conducted on several STS Personnel Protection Systems (PPS). The reviews focused primarily on the integration with the existing SNS PPS, the new proton transport tunnel, and the target areas. Development of the PPS is ongoing, to ensure a coherent safety system with the mission of protecting users and workers from prompt radiation hazards while providing high beam availability to operations. The STS PPS element in the Integrated Control System (ICS) is a facility-wide system composed of multiple safety subsystems, including the Ring to Second Target (RTST) beam transport tunnel, Target, Bunker and Instruments. Personnel working in all these geographic areas are protected by modular reliable PPS solutions. The safety system enforces access controls, radiation monitoring, beam destination control, and application of critical device inhibit upon detection of abnormal condition. It uses well-documented processes, Common Industrial Protocol (CIP) safety, pulsed test, and redundancy to achieve the desired Safety Integrity Level (SIL). This paper gives an architectural overview of the STS PPS and a detailed safety plan for the SNS facility, addressing safety solutions and human factors.

Michaelides, Tommy [ORNL] (ORCID:0000000190499869)↗

An Investigation of the Ice Cloud Detection Sensitivity of Cloud Radars Using the Raman Lidar at the ARM SGP Site

The ice cloud detection sensitivity of the millimeter cloud radar (MMCR) and the Ka-band Zenith radar (KAZR) is investigated using a collocated Raman lidar (RL) at the Atmospheric Radiation Measurement Program Southern Great Plains site. Only profiles that are transparent to the RL with ice clouds only are considered in this study. The MMCR underestimates the RL ice cloud optical depth (COD) by 20%. The MMCR detects no ice clouds in 37% of the profiles. These profiles where ice cloud goes undetected by the MMCR typically contain very optically thin clouds, with a mean RL ice COD of 0.03. Higher ice cloud detection sensitivity is found for the KAZR, which underestimates the RL ice COD by 15%. The decrease in the ice COD bias for the KAZR compared to the MMCR is largely due to a decrease in the ice COD bias for the situation where the transparent profiles with ice clouds are detected by both the RL and cloud radar. The climatic net ice cloud radiative effects (CREs) from the RL at the top of the atmosphere (TOA) and the surface are 3.2 W m−2 and −0.6 W m−2, respectively. The ice CREs at the TOA and surface are underestimated for the MMCR by 0.7 W m−2 and 0.16 W m−2 (21% and 29%) and underestimated for the KAZR by 0.6 W m−2 and 0.14 W m−2 (17% and 24%). The ice clouds undetected by the cloud radars led to underestimating the climatic net cloud heating rates below 150 hPa by about 0–0.04 K day−1.

54 ENVIRONMENTAL SCIENCES↗

Measuring Very Low Radiation Doses in PTFE for Nuclear Forensic Enrichment Reconstruction

Every country that has made nuclear weapons has used uranium enrichment. Despite the centrality of this technology to international security, there is still no reliable physical marker of past enrichment that can be used to perform forensic verification of historically produced weapons. We show that the extremely low radioactivity from uranium alpha emissions during enrichment leaves detectable and irreversible calorimetric signatures in the common enrichment gasket material PTFE, allowing for historical reconstruction of past enrichment activities at a sensitivity better than one weapon's quantity of highly enriched uranium. Fast scanning calorimetry also enables the measurement of recrystallization enthalpies of sequentially microtomed slices, confirming the magnitude and the type of radiation exposure while also providing a detection of tampering and a method for analyzing field samples useful for treaty verification. This work opens the door for common items to be turned into precise dosimeters to detect the past presence of radioactivity, nuclear materials, and related activities with high confidence.

Connick, Rachel↗

Integrated Circuit Design for Radiation-Hardened Charge-Sensitive Amplifier Survived up to 2 Mrad

According to the continuous development of metal-oxide semiconductor (MOS) fabrication technology, transistors have naturally become more radiation-tolerant through steadily decreasing gate-oxide thickness, increasing the tunneling probability between gate-oxide and channel. Unfortunately, despite this radiation-hardened property of developed transistors, the field of nuclear power plants (NPPs) requires even higher radiation hardness levels. Particularly, total ionizing dose (TID) of approximately 1 Mrad could be required for readout circuitry under severe accident conditions with 100 Mrad around a reactor in-core required. In harsh radiating environments such as NPPs, sensors such as micro-pocket-fission detectors (MPFD) would be a promising technology to be operated for detecting neutrons in reactor cores. For those sensors, readout circuits should be fundamentally placed close to sensing devices for minimizing signal interferences and white noise. Therefore, radiation hardening ability is necessary for the circuits under high radiation environments. This paper presents various integrated circuit designs for a radiation hardened charge-sensitive amplifier (CSA) by using SiGe 130 nm and Si 180 nm fabrication processes with different channel widths and transistor types of complementary metal-oxide-semiconductor (CMOS) and bipolar CMOS (BiCMOS). These circuits were tested under γ–ray environment with Cobalt-60 of high level activity: 490 kCi. The experiment results indicate amplitude degradation of 2.85%–34.3%, fall time increase of 201–1730 ns, as well as a signal-to-noise ratio (SNR) of 0.07–11.6 dB decrease with irradiation dose increase. These results can provide design guidelines for radiation hardening operational amplifiers in terms of transistor sizes and structures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Light-tight Skipper-CCDs for X-Ray Detection in Space

Skipper Charge-Coupled Devices (skipper-CCDs) are pixelated silicon detectors with deep sub-electron resolution. Their radiation hardness and capability to reconstruct energy deposits with unprecedented precision make them a promising technology for space-based X-ray astronomy. In this scenario, optical and near-infrared photons may saturate the sensor, distorting the reconstructed signal. We present a light-tight shield for skipper-CCDs to suppress optical backgrounds while preserving X-ray detection efficiency. We deposited thin aluminum layers on the CCD surface using an e-beam evaporator and evaluated their blinding performance across wavelengths from 650 to 1000 nm using a monochromator, as well as the X-ray transmission using an 55 Fe source. We find that 50 and 100 nm layers provide >99.6% light suppression, with no efficiency loss for 5.9 and 6.4 keV X-rays. In addition, we used Geant4 simulations to extend these results to a broader energy range and quantify the efficiency loss for different aluminum thicknesses. Results show that thin aluminum coatings are an effective, low-cost solution for optical suppression in skipper-CCDs intended for X-ray detection and space instrumentation.

79 ASTRONOMY AND ASTROPHYSICS↗

The Use of Long-wave Infrared Cameras for Hazardous Waste Remediation - 20457

For over fifty years, infrared cameras have been used in military applications, nondestructive testing, condition monitoring, and predictive maintenance. As infrared cameras continue to become more sophisticated and less expensive, they are providing value in an ever-increasing variety of unique applications, including hazardous waste remediation. This paper describes several instances of how infrared cameras have been used within the US Department of Defense and the US Department of Energy in support of waste remediation projects, including the author's recent use of an infrared camera in support of the Calcine Retrieval Project at the Idaho National Laboratory. Infrared cameras provide images of infrared radiation, or heat energy, which is otherwise invisible to the unaided eye. Infrared radiation is part of the electromagnetic spectrum, which includes visible light. But unlike visible light, infrared has wavelengths longer than the human eye can detect. Infrared is emitted by everything with a temperature above absolute zero (-273 deg. C, or -459 deg. F); the higher the temperature, the greater the infrared thermal radiation, or heat, that is emitted. Even objects that feel cold to us, like ice, emit thermal radiation and can be imaged by infrared cameras. These cameras are typically used to look for abnormally hot or cold spots on a component or target area under normal operating conditions. The method provides a rapid, wide-area, noncontact technique for identifying problems associated with a temperature differential. All infrared cameras can provide qualitative thermal information by displaying relative differences in temperatures within a two-dimensional image. More expensive infrared cameras can also provide quantitative information where an absolute temperature value is assigned to each pixel associated with the displayed two-dimensional image. Proper camera calibration and a solid understanding of heat transfer and thermography techniques are required when using an infrared camera to obtain quantitative information. Case studies outlined in this paper include the rapid, non-intrusive detection of hazardous decontamination solution within one-ton shipping containers at Pine Bluff Arsenal, the non-intrusive identification of residual elemental sodium within the cooling loops of the Experimental Breeder Reactor II (EBR-II) reactor at the Idaho National Laboratory, process monitoring of heat exchanger melt-and-drain efforts during EBR-II decommissioning, and the remote detection of internal steel supports within calcine storage bins prior to bin penetration. For each use of thermography, the author describes a summary of the waste remediation effort, the infrared camera used, the thermal imaging technique employed, and the results obtained. The paper concludes with a discussion on common mistakes to avoid for similar applications of thermography. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhanced Neutron and γ-Ray Detection via 6 Li Substitution in Undoped and Tl-Doped Zero-Dimensional Perovskite Cs 3 Cu 2 I 5 Scintillators

Radiation detectors are crucial in a wide variety of research and commercial applications, such as oil and gas exploration, medical imaging, nuclear nonproliferation, and homeland security. Neutron and gamma-ray detectors are fundamental components in portal monitors at ports and border crossings, bolstering national security against radiological threats. This study presents a dual-mode scintillator, undoped and Tl-doped 6 Li-Cs 3 Cu 2 I 5 , and demonstrates its potential as a promising material for simultaneous thermal neutron and gamma-ray detection. We explore the Bridgman growth of both undoped and thallium doped Li → Cu and Li → Cs substitutional systems with various Li doping levels and assess their impact on scintillation properties. Under 662 keV gamma-ray excitation, the undoped crystals had light yields up to 35,900 ph/MeV, with energy resolutions down to 4.5%. The Tl-doped crystals performed better than the undoped crystals with light yields peaking at 65,900 ph/MeV and energy resolutions as low as 3.5%. When exposed to a moderated 252 Cf excitation source, our crystals had light yields between 102,900 and 167,200 photons per thermal neutron capture, with a full energy thermal neutron peak reaching 3 MeV in gamma equivalent energy. Pulse shape discrimination studies reveal well-separated gamma and neutron events, resulting in Figure-Of-Merit (FOM) as high as 3.7. Furthermore, these findings highlight the potential of Li-doped Cs 3 Cu 2 I 5 as a viable candidate for next-generation dual-mode scintillators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗