Investigation of external refrigeration systems for long-term cryogenic storage
Evaluation of cryogenic refrigeration systems for space applications
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Evaluation of cryogenic refrigeration systems for space applications
Handbook of external refrigeration systems for long term cryogenic storage
Mobile transport system, that can be carried by truck and parked in storage area, consists of an inner container capable of holding 363 kg of diborane and an external, dual refrigeration unit which uses liquid nitrogen and Freon-14.
An experimental investigation was conducted in a five-second zero gravity facility to examine the effects of venting initially saturated Refrigerant 11 from a cylindrical container (15-cm diameter) under reduced gravitational conditions. The system Bond numbers studied were 0 (weightlessness), 9 and 63; the liquid exhibited a nearly zero-degree contact angle on the container surface. During the venting process, both liquid-vapor interface and liquid bulk vaporization occurred. The temperature of the liquid in the immediate vicinity of the liquid-vapor interface was found to decrease during venting, while the liquid bulk temperature remained constant. Qualitative observations of the effects of system acceleration, vent rate, and vapor volume presented. Quantitative information concerning the ullage pressure decay during low gravity venting is also included.
Compatibility of the Brayton power and refrigeration cycles is considered. Performance of the power- and cryo-loop is plotted against compressor pressure ratio. The power- and cryo-loop performance is determined by dividing the compressor work between the two loops in proportion to mass flow rate. Cycle efficiency is defined as the ratio of shaft power available in the power loop to the net thermal input from the heat source. The available shaft power is the excess of the power turbine work over the compressor work needed in the power loop. The best power loop efficiency occurred at a compressor pressure ratio of 1.8, and the best cryo-loop performance was at a compressor pressure ratio of 2.1. Good individual cycle performance occurred over a fairly large range in compressor pressure ratio.
An investigation was conducted of the peak heat flux on cylindrical heaters in a fluid flowing perpendicular to the major axis of the heater. The test fluids were water and Refrigerant 113. Heaters of 0.049 to 0.181 cm diameter were tested over a fluid velocity range of 10.1 to 81.1 cm/sec. The experimental results were observed to fall within two regions based on the vapor removal geometry: jets or sheets. Mathematical models for each region successfully correlated the data for both fluids.
Basic equations of momentum and energy are presented and discussed with respect to heat transfer and pressure drop for forced flow condensation in horizontal tubes under 1-g and 0-g conditions. Some experimental results are presented for condensing refrigerant-12 in a system of three parallel-connected quartz tubes (3-mm inside diameter, G = 1.037 to 3.456 x 105 lbm/hr-sq. ft). From high speed photographs, measurements were obtained of film thickness, phase velocities, disturbance wavelengths, and flow regimes and their transitions. Based upon these measurements various dimensionless force ratios (flow and instability parameters) were calculated. Under 0-g conditions a uniformly thick redistribution of liquid condensate about the tube walls was found to result in a lowered heat transfer coefficient as compared with 1-g conditions, based upon fundamental heat transfer theory. A model is proposed that takes into account the difference in heat transfer due to condensate distribution under 1-g and 0-g conditions.
The on-orbit performance of the Skylab refrigeration system components is presented. Flight anomalies are analyzed and performance of the newly developed components is described. Nine months of orbit data proved the practicality of the leak-free coolant system design. Flight proven application of a thermal capacitor and development test results of the first all-mechanical, low temperature mixing valve represent a significant advance in single-phase, low temperature coolant loop design. System flight data suggest that additional instrumentation and fluid filters could have prevented system orbit performance anomalies.
Temperature-sensing bridge determines liquid reserve level in low-temperature heat exchanger. Device should be of interest to manufacturers of cryogenic refrigerators as well as to those who use them in conjunction with operation of electronic equipment like masers or Josephson junctions.
A device developed to isolate the diode laser from impact shocks delivered during the expansion phase of the Solvay cycle of a helium refrigerator is briefly described. The device uses intermediate cold stations in the stand-off, which permit the stand-off to be short and rigid while minimizing the thermal load at the diode mount.
Closed-cycle helium refrigerator sensor generates negative-feedback control signals that drive heating diode to maintain temperature stability. Temperature-sensing diode and heating diode are mounted on heat sink that provides conductive path between load and cold tip. Method is applicable to other temperature-control applications, such as laser equipment, electronic instruments, and computer systems.
A closed cycle refrigeration (CCR) system is disclosed for providing cooling at different parts of a maser. The CCR includes a first station for cooling the maser's parts, except the amplifier portion, to 4.5 K. The CCR further includes means with a 3.0 K station for cooling the maser's amplifier to 3.0 K and, thereby, increases the maser's gain and/or bandwith by a significant factor. The means which provide the 3.0 K cooling include a pressure regulator, heat exchangers, an expansion valve, and a vacuum pump, which coact to cause helium, provided from a compressor, to liquefy and thereafter expand so as to vaporize. The heat of vaporization for the helium is provided by the maser amplifier, which is thereby cooled to 3.0 K.
Cycling of a closed-cycle refrigerator produces temperature oscillations at the cold-tip which may be 0.5 K peak-to-peak. An active diode heater is described which compensates for the varying temperature and reduces the oscillations at the sample to about 0.003 K peak-to-peak at 9.5 K.
Design criteria are easily evaluated by tool. Thermodynamic analysis of solar-powered vapor-jet refrigerator combines important performance parameters in nomogram that assist design of practical system. Projected coefficients of performance for difference ejector configurations, working fluids, and other design variables are easily obtained from nomogram.
Closed-cycle operation of molecular adsorption refrigeration systems (MARS) has been demonstrated by using thermally cycled zeolites to adsorb and desorb various gases under pressures of 20-60 atm. This paper develops three aspects of the design theory: the physical theory of molecular adsorption of small molecules such as A, N2, N2O and NH3, the design relations for closed-cycle flow for three or more compressors, and the coefficient of performance. This work is intended to demonstrate nonmechanical gas compression for various cryogenic gases than can compete with mechanical systems with a different mix of advantages and disadvantages.
A new approach to the development of a 3- to 5-year lifetime Stirling cycle refrigerator for space is described. The reciprocating components would be driven directly by linear motors. There would be no contact between the moving components and the machine housing or motor during operation. The noncontact operation can be achieved either by magnetic or gas bearings and clearance seals. Consequently, two major contractual efforts are underway, one to develop the magnetic-bearing cooler and the other to develop the gas-bearing machine. The coolers are required to have a 5-W capability at 65 K and to be dynamically balanced. The results of the major contractor phase 1 design definition studies and component testing are discussed. Both the gas-bearing and magnetic-bearing coolers show promise for achieving the 3- to 5-year lifetime goal.
At the present time all traveling-wave maser and closed-cycle refrigerator system (TWM-CCR) and their power supply and helium compressor assemblies are operated manually. Many man-hours are required of highly trained and experienced operators, resulting in high operator cost. Of greater importance are the problems of unpredictable failure and long downtimes. Since field performance is not monitored, system degradation is detected only when it has progressed to the point of catastrophic failure. Without the aid of performance histories, failure diagnosis is arduous and slow. Rational and functional requirements for the TWM-CCR Automation project are the following: (1) to improve reliability and reduce downtime by providing unattended monitor and control, alarm and fault location, failure prediction and self-corrective action; (2) to reduce operator cost by providing automatic tuning and cooldown procedures; and (3) to improve system operations and development by providing the needed engineering data.
Refrigeration module with no moving parts attaches to cold plate of cryostat to reduce temperature. Module includes evaporation chamber, condenser and absorption pump.