Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “READOUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Cryogenic optical systems and instruments II; Proceedings of the Meeting, Los Angeles, CA, Jan. 23, 24, 1986

The topics of the present conference encompass cryogenic optical system design considerations, cryogenic instruments and their components, the design and performance of cryogenic dewars for space, and technologies supporting cryogenic systems and instruments. Attention is given to the Space IR Telescope Facility (SIRTF) observatory's design and on-orbit servicing, hardware development for the Gravity Probe-B program, the multiband imaging photometer aboard SIRTF, and the SIRTF wide field, diffraction-limited array camera. Also discussed are the cryogenic star-tracking telescope for Gravity Probe-B, a balloon-borne spectrometer for measurement of lower stratospheric trace constituents, the primary mirror support system design for a cryogenic space telescope, and the SQUID readout and ultralow magnetic fields of Gravity Probe-B.

Melugin, Ramsey K.↗

Hardware development for Gravity Probe-B

Gravity Probe-B (GP-B), also known as the Stanford Relativity Gyroscope Experiment, will test two fundamental predictions of Einstein's General Theory of Relativity by precise measurement of the precessions of nearly perfect gyroscopes in earth orbit. This endeavor embodies state-of-the-art technologies in many fields, including gyroscope fabrication and readout, cryogenics, superconductivity, magnetic shielding, precision optics and alignment methods, and satellite control systems. These technologies are necessary to enable measurement of the predicted precession rates to the milliarcsecond/year level, and to reduce to 'near zero' all non-General Relativistic torques on the gyroscopes. This paper provides a brief overview of the experiment followed by descriptions of several specific hardware items with highlights on progress to date and plans for future development and tests.

Bardas, D.↗

Cryogenic star-tracking telescope for Gravity Probe B

This paper describes the design, development and preliminary testing of the cryogenic star-tracking telescope used as an optical reference for the gyroscopes in the Gravity Probe B Relativity Gyroscope experiment. The telescope is operated at 1.8 K; it is fabricated entirely from fused quartz components held together by optical contacting; it has a physical length of 14 in., a focal length of 150 in. and an aperture of 5.6 in. Readout is by two photomultiplier chopper-detector assemblies at ambient satellite temperature. When fully operational, the telescope may be expected to have a precision approaching 0.1 milliarcsec over a linear range of 70 + or 70 milliarcsec. Its projected noise performance corresponds to an angular resolution of 1 milliarcsec in 1 Hz bandwidth. The paper includes a theoretical analysis, a description of the design and fabrication of a laboratory version of the telescope, a discussion of techniques of optical contacting, an account of vibration tests on a separate mass model of the telescope, a description of the artificial star developed for optical tests, and an account of preliminary experimental results.

Everitt, C. W. F.↗

A one-megapixel image acquisition and processing system for solar oscillation studies

The 1-Mpixel image acquisition and processing system that has been installed at the Mt. Wilson observatory as part of the development effort for the NASA/ESA Solar Oscillations Imager Experiment of the projected Heliospheric Observatory mission is discussed. The system encompasses a high speed CCD camera with a 1024 x 1024-pixel virtual phase chip array, yielding a readout rate of about 800,000 pixels/sec; this allows the entire Mpixel array to be read out in just over 1 sec. The camera is interfaced with a floating point array processor that integrates several successive exposures from the CCD camera and differences selected pairs of integrated images. The system is currently being used to record and difference narrowband images of the sun.

Rhodes, Edward J., Jr.↗

The Palomar Observatory CCD camera

Standard designs for Dewars and electronics which have been developed for the Palomar Observatory CCD camera are described in detail. The Dewars described have holding times of about 17 to 24 hours. In-operation readout-noise levels of about 8 electrons are achieved for TI 800 x 800 CCDs; tests of these CCDs reveal that, over their range of operation, the amplifiers and A/D converters are linear to better than 0.2 percent.

Gunn, J. E.↗

Scientific charge-coupled devices

The charge-coupled device dominates an ever-increasing variety of scientific imaging and spectroscopy applications. Recent experience indicates, however, that the full potential of CCD performance lies well beyond that realized in devices currently available.Test data suggest that major improvements are feasible in spectral response, charge collection, charge transfer, and readout noise. These properties, their measurement in existing CCDs, and their potential for future improvement are discussed in this paper.

Janesick, James R.↗

Toolmaker's Microscope With Video Monitor

Display accessories increase resolution and flexibility of use. Toolmaker's microscope equipped with video monitor, auxiliary lighting, and high-resolution readout devices enables noncontacting measurements of tiny slots, indentations, and similar features on parts. Measures places difficult or impossible to reach by mechanical means.

Ahmed, Arif S.↗

Detector Arrays For Infrared Astronomy

Paper describes status of program for developing integrated infrared detectors for astronomy. Program covers variety of detectors, including extrinsic silicon, extrinsic germanium, and indium antimonide devices with hybrid silicon multiplexers. Paper notes for arrays to reach background noise limit in cryogenic telescope, continued reductions in readout noise and dark current needed.

Mccreight, C. R.↗

Analysis of pre-flight modulator voltage calibration data for the Voyager plasma science experiment

The Voyager Plasma Science (PLS) modulator calibration (MVM) data analysis was undertaken in order to check the correctness of the fast A/D converter formulas that connect low voltage monitor signals (MV) with digital outputs (DN), to determine the proportionality constants between the actual modulator grid potential (V) and the monitor voltage (MV), and to establish an algorithm to link the digitized readouts (DN) with the actual grid potential (V). The analysis results are surprising in that the derived conversion constants deviate by fairly significant amounts from their nominal values. However, it must be kept in mind that the test results which were used for analysis may be very imprecise. Even if it is assumed that the test result errors are very large, they do no appear to be capable to account for all discrepancies between the theoretical expectations and the results of the analysis. Measurements with the flight spare instrument appear to be the only means of investigating these effects further.

Nastov, Ognen↗

Space infrared telescope facility wide field and diffraction limited array camera (IRAC)

The wide-field and diffraction limited array camera (IRAC) is capable of two-dimensional photometry in either a wide-field or diffraction-limited mode over the wavelength range from 2 to 30 microns with a possible extension to 120 microns. A low-doped indium antimonide detector was developed for 1.8 to 5.0 microns, detectors were tested and optimized for the entire 1.8 to 30 micron range, beamsplitters were developed and tested for the 1.8 to 30 micron range, and tradeoff studies of the camera's optical system performed. Data are presented on the performance of InSb, Si:In, Si:Ga, and Si:Sb array detectors bumpbonded to a multiplexed CMOS readout chip of the source-follower type at SIRTF operating backgrounds (equal to or less than 1 x 10 to the 8th ph/sq cm/sec) and temperature (4 to 12 K). Some results at higher temperatures are also presented for comparison to SIRTF temperature results. Data are also presented on the performance of IRAC beamsplitters at room temperature at both 0 and 45 deg angle of incidence and on the performance of the all-reflecting optical system baselined for the camera.

Fazio, Giovanni G.↗

The dc power control for a liquid-fed resistojet

A simple breadboard power controller was designed and demonstrated for a new liquid-fed water resistojet. The 1-piece laboratory model thruster has an integrated vaporizer/superheater using a single heating element. Heater temperature was maintained at or near a preset reference value with the closed loop controller providing pulse width modulated (PWM) dc power into the thruster heater. A combined thruster, temperature readout, PWM transfer function was experimentally determined. This transfer function was used to design a proportional plus integral controller that demonstrated zero steady state error, conservative stability margins and adequate transient response to step changes in propellant flow rate, input voltage and temperature reference. Initial turn-on temperature overshoot from room temperature to a 650 C setpoint was 80 C. In addition, EMI was alleviated by reducing heater dI/dt and dV/dt using a simple diode-inductor-capacitor network. Based on limited initial tests, thruster preheat with no propellant flow was necessary to achieve stable system operation during startup. Breadboard power efficiency was 99 percent at 1 kW, and component mass was 0.4 kg excluding the power loss and mass of an input filter required for spacecraft integration.

Gruber, Robert P.↗

Recent developments on a 128 x 128 indium antimonide/FET switch hybrid imager for low-background applications

By combining high-quality mesa photovoltaic indium antimonide detector material with a silicon x-y FET switch multiplexer, a useful infrared area detector has been developed. This device is intended for low-background applications, where high sensitivity is required. Initial characterization of the detector at 80 K showed a KTC limited read noise of less than 1000 electrons, good dark current, responsivity uniformity, and a maximum readout rate of 10 MHz. The hybrid mating technology has sufficient precision to allow expansion to a 256 x 256 format. The dark current in the detector material is sufficiently low to allow full-frame integration, even with arrays as large as 256 x 256 elements.

Bailey, Gary C.↗

Test of IR arrays on the Kuiper Airborne Observatory

NASA's Kuiper Airborne Observatory, which is a C-141 transport aircraft equipped with a 90-cm, all-reflective altazimuth telescope, has been engaged in the Kuiper Infrared Technology Experiment. Attention is presently given to the Experiment's flight series for state-of-the-art two-dimensional, 500-element arrays that use either blocked impurity band or bulk silicon devices. The switched FET readout scheme used on the three arrays flown thus far yields exceptionally low crosstalk. System sensitivities are found to be sufficient for the detection of both pointlike and extended sources; several of each type have been used in staring and scanning experiments.

Russell, R. W.↗

Integrated infrared array technology

An overview of integrated infrared (IR) array technology is presented. Although the array pixel formats are smaller, and the readout noise of IR arrays is larger than the corresponding values achieved with optical charge-coupled-device silicon technology, substantial progress is being made in IR technology. Both existing IR arrays and those being developed are described. Examples of astronomical images are given which illustrate the potential of integrated IR arrays for scientific investigations.

Goebel, J. H.↗

Composite Semiconductor Substrates

Epitaxial structure of three semiconductor materials - silicon, gallium arsenide, and cadmium telluride - makes possible integrated monolithic focal-plane arrays of photodectors. Silicon layer contains charge-coupled devices, gallium arsenide layer contains other fast electronic circuitry, and cadmium telluride layer serves as base for array of mercury cadmium telluride infrared sensors. Technique effectively combines two well-established techniques; metalorganic chemical-vapor deposition (MOCVD) and molecular-beam epitaxy (MBE). Multilayer structure includes HgCdTe light sensors with Si readout devices and GaAs signal-processing circuits. CdTe layer provides base for building up HgCdTe layer.

Nouhi, Akbar↗

Support of the eight-foot high-temperature tunnel modifications project

An ultrasonic level sensor was developed to measure the liquid level in a storage vessel under high pressures, namely up to 6000 psi. The sensor is described. A prototype sensor was installed in the cooling-water storage vessel of the Eight-Foot High-Temperature Tunnel. Plans are being made to install the readout instrument in the control room, so that tunnel operators can monitor the water level during the course of a tunnel run. It was discovered that the sensor will operate at cryogenic temperatures. Consequently, a sensor will be installed in the modified Eight-Foot High-Temperature Tunnel to measure the sound speed of liquid oxygen (LOX) as it is transferred from a storage vessel to the tunnel combustor at pressure of about 3000 psi. The sound speed is known to be a reliable indicator of contamination of LOX by pressurized gaseous nitrogen, which will be used to effect the transfer. Subjecting the sensor to a temperature cycle from room temperature to liquid nitrogen temperature and back again several times revealed no deterioration in sensor performance. The method using this sensor is superior to the original method, which was to bleed samples of LOX from the storage vessel to an independent chamber for measurement of the sound speed.

Hodges, Donald Y.↗

Magnetic and electric field meters developed for the US Department of Energy

This report describes work done at the Jet Propulsion Laboratory for the Office of Energy Storage and Distribution of DOE on the measurement of power line fields. A magnetic field meter is discussed that uses fiber optics to couple a small measuring probe to a remote readout device. The use of fiber optics minimizes electric field perturbation due to the presence of the probe and provides electric isolation for the probe, so that it could be used in a high field or high voltage environment. Power to operate the sensor electronics is transferred via an optical fiber, and converted to electrical form by a small photodiode array. The fundamental, the second and third harmonics of the field are filtered and separately measured, as well as the broadband rms level of the field. The design of the meter is described in detail and data from laboratory tests are presented. The report also describes work done to improve the performance of a DC bushing in a Swedish factory, using the improved meter. The DC electric fields are measured with synchronous detection to provide field magnitude data in two component directions.

Kirkham, H.↗