At least 649 records · Page 36

WE-D-BRD-01: New Linac Designs for MR-Guided Therapy Systems

The advantages that make MR highly desirable for in-room treatment guidance, i.e. soft-tissue visualization and physiological assessment of healthy/tumor tissues, are largely recognized in the research community. However, the MR absorption in practical clinical workflows is still hindered by lack of sufficient technological infrastructure. Recent advances have been made towards filling that gap such as the development of integrated therapy systems relying on an MR scanner and a radiation source (linac, Co-60) and/or brachytherapy. The session is intended to present new efforts and methods aimed at facilitating the adoption of MR guidance for treatment delivery. Specifically, the discussion will focus on a) linac designs for reduced footprint and seamless integration with MR/linac systems, b) tracking coils for brachytherapy applications, and c) procedures for the commissioning and monitoring of MR and MR/linac performance. Learning Objectives: Understand limitations and proposed solutions for linac designs and associated integration with MR/linac systems; Understand current issues with MR-guided brachytherapy procedures Understand the issues and needs for new MR commissioning and QC. License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image distortions.

60 APPLIED LIFE SCIENCES↗

WE-D-BRD-02: Tracking Coils for Brachy MR Guidance

The advantages that make MR highly desirable for in-room treatment guidance, i.e. soft-tissue visualization and physiological assessment of healthy/tumor tissues, are largely recognized in the research community. However, the MR absorption in practical clinical workflows is still hindered by lack of sufficient technological infrastructure. Recent advances have been made towards filling that gap such as the development of integrated therapy systems relying on an MR scanner and a radiation source (linac, Co-60) and/or brachytherapy. The session is intended to present new efforts and methods aimed at facilitating the adoption of MR guidance for treatment delivery. Specifically, the discussion will focus on a) linac designs for reduced footprint and seamless integration with MR/linac systems, b) tracking coils for brachytherapy applications, and c) procedures for the commissioning and monitoring of MR and MR/linac performance. Learning Objectives: Understand limitations and proposed solutions for linac designs and associated integration with MR/linac systems; Understand current issues with MR-guided brachytherapy procedures Understand the issues and needs for new MR commissioning and QC. License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image distortions.

60 APPLIED LIFE SCIENCES↗

WE-D-BRD-03: Novel Methods and Tools for MR Commissioning and QC

The advantages that make MR highly desirable for in-room treatment guidance, i.e. soft-tissue visualization and physiological assessment of healthy/tumor tissues, are largely recognized in the research community. However, the MR absorption in practical clinical workflows is still hindered by lack of sufficient technological infrastructure. Recent advances have been made towards filling that gap such as the development of integrated therapy systems relying on an MR scanner and a radiation source (linac, Co-60) and/or brachytherapy. The session is intended to present new efforts and methods aimed at facilitating the adoption of MR guidance for treatment delivery. Specifically, the discussion will focus on a) linac designs for reduced footprint and seamless integration with MR/linac systems, b) tracking coils for brachytherapy applications, and c) procedures for the commissioning and monitoring of MR and MR/linac performance. Learning Objectives: Understand limitations and proposed solutions for linac designs and associated integration with MR/linac systems; Understand current issues with MR-guided brachytherapy procedures Understand the issues and needs for new MR commissioning and QC. License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image distortions.

60 APPLIED LIFE SCIENCES↗

High pressure study of Ti[subscript 4]AlN[subscript 3] to 55 GPa

Using a synchrotron radiation source and a diamond anvil cell, we measured the pressure dependence of the lattice parameters of a polycrystalline Ti{sub 4}AlN{sub 3} sample up to a pressure of 55 GPa. No phase transformations were observed. As observed in Ti{sub 3}SiC{sub 2}, Ti{sub 3}Si{sub 0.5}Ge{sub 0.5}C{sub 2}, and Zr{sub 2}InC, the compressibility of Ti{sub 4}AlN{sub 3} along the c axis was larger than along the a axis which leads to a decrease in the c/a ratio with increasing pressure. The bulk modulus is 216 {+-} 2 GPa, with a pressure derivative of 3.84 {+-} 0.06.

43 PARTICLE ACCELERATORS↗

Surface acoustic wave propagation in graphene film

Surface acoustic wave (SAW) propagation in a graphene film on the surface of piezoelectric crystals was studied at the BESSY II synchrotron radiation source. Talbot effect enabled the visualization of the SAW propagation on the crystal surface with the graphene film in a real time mode, and high-resolution x-ray diffraction permitted the determination of the SAW amplitude in the graphene/piezoelectric crystal system. The influence of the SAW on the electrical properties of the graphene film was examined. It was shown that the changing of the SAW amplitude enables controlling the magnitude and direction of current in graphene film on the surface of piezoelectric crystals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gamma Imaging and Mapping Advancements

The SRNL developed GrayQb{sup TM} gamma mapping system has been successfully deployed in field situations. Currently, to get the image from the GrayQb{sup TM} the internal Phosphor Storage Plate (PSP) used to capture radiation images must be recovered and scanned by a ScanX Scanner. Upgrades are being implemented which will enable the GrayQB{sup TM} to read the PSP using a camera and red LEDs then transmit results to a remote location. This will greatly reduce personnel interaction, increasing safety as well as eliminating the need for the ScanX. Upgrades have been based off of the MiniMax, a Los Alamos National Laboratory developed PSP reading device constructed with a Nikon DSLR and a red LED flash to obtain the images from the PSP. The electronics in the upgraded GrayQb{sup TM} need to be both functional and environmentally rugged. A PC/104 was chosen for its wider operational temperature range and its physical durability. The Sony α7 ii and the Mightex are the candidate cameras for the upgrades based on test results. PSPs were exposed to gamma radiation sources at SRS's Health Physics Instrumentation Calibration Laboratory (HPICL). PSPs were tested with both Am-241 and Cs-137. Linear intensity increased with dose verifying UV image simulations. Data collected enabled the PSP intensity to be referenced to a total dose. Further work includes design and implementation of a 3D printed housing for the new camera system. The housing will include the camera, light flash, PSP holders, tungsten dual pinhole, PC/104, dosimeter, and a battery or tethering option. Once the housing is finalized further testing at the HPICL facility is planned for early August. During this testing, the final housing design will capture both Am-241 and Cs-137 images.

3D PRINTING↗

Observation of a new electronic state of CO perturbing W{sup 1}Π(υ=1)

We observe photoabsorption of the W(1) ← X(0) band in five carbon monoxide isotopologues with a vacuum-ultraviolet Fourier-transform spectrometer and a synchrotron radiation source. We deduce transition energies, integrated cross sections, and natural linewidths of the observed rotational transitions and find a perturbation affecting these. Following a deperturbation analysis of all five isotopologues, the perturbing state is assigned to the υ = 0 level of a previously unobserved {sup 1}Π state predicted by ab initio calculations to occur with the correct symmetry and equilibrium internuclear distance. We label this new state E{sup ″} {sup 1}Π. Both of the interacting levels W(1) and E{sup ″}(0) are predissociated, leading to dramatic interference effects in their corresponding linewidths.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monte Carlo study of the energy and angular dependence of the response of plastic scintillation detectors in photon beams

Purpose: By using Monte Carlo simulations, the authors investigated the energy and angular dependence of the response of plastic scintillation detectors (PSDs) in photon beams. Methods: Three PSDs were modeled in this study: A plastic scintillator (BC-400) and a scintillating fiber (BCF-12), both attached by a plastic-core optical fiber stem, and a plastic scintillator (BC-400) attached by an air-core optical fiber stem with a silica tube coated with silver. The authors then calculated, with low statistical uncertainty, the energy and angular dependences of the PSDs' responses in a water phantom. For energy dependence, the response of the detectors is calculated as the detector dose per unit water dose. The perturbation caused by the optical fiber stem connected to the PSD to guide the optical light to a photodetector was studied in simulations using different optical fiber materials. Results: For the energy dependence of the PSDs in photon beams, the PSDs with plastic-core fiber have excellent energy independence within about 0.5% at photon energies ranging from 300 keV (monoenergetic) to 18 MV (linac beam). The PSD with an air-core optical fiber with a silica tube also has good energy independence within 1% in the same photon energy range. For the angular dependence, the relative response of all the three modeled PSDs is within 2% for all the angles in a 6 MV photon beam. This is also true in a 300 keV monoenergetic photon beam for PSDs with plastic-core fiber. For the PSD with an air-core fiber with a silica tube in the 300 keV beam, the relative response varies within 1% for most of the angles, except in the case when the fiber stem is pointing right to the radiation source in which case the PSD may over-response by more than 10%. Conclusions: At {+-}1% level, no beam energy correction is necessary for the response of all three PSDs modeled in this study in the photon energy ranges from 200 keV (monoenergetic) to 18 MV (linac beam). The PSD would be even closer to water equivalent if there is a silica tube around the sensitive volume. The angular dependence of the response of the three PSDs in a 6 MV photon beam is not of concern at 2% level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spin Polarization Dynamics of Nonequilibrium Conduction Electrons in Magnetic Junctions

The dynamics of the motion of the magnetic moment averaged over an ensemble of nonequilibrium spin-injected electrons in a ferromagnetic junction is considered with allowance for the exchange interaction, as well as the interaction with an external electromagnetic field and a thermostat. The solution of this problem is important for the experimental development of compact terahertz-band radiation sources. The rate of quantum transitions of electrons with opposite spins, which determine the spin relaxation under the interaction with a thermostat, is calculated within the density matrix formalism. It is shown that two spin-relaxation modes can be implemented that correspond to low- and high-Q precession of spin-nonequilibrium injected electrons. The effect of the characteristic features of spin-flip transitions under the relaxation of the magnetic moment on the emission and absorption of photons with-energy corresponding to the energy of effective exchange splitting of spin subbands is discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Kinetic equilibria of relativistic collisionless plasmas in the presence of non-stationary electromagnetic fields

The kinetic description of relativistic plasmas in the presence of time-varying and spatially non-uniform electromagnetic (EM) fields is a fundamental theoretical issue both in astrophysics and plasma physics. This refers, in particular, to the treatment of collisionless and strongly-magnetized plasmas in the presence of intense radiation sources. In this paper, the problem is investigated in the framework of a covariant gyrokinetic treatment for Vlasov–Maxwell equilibria. The existence of a new class of kinetic equilibria is pointed out, which occur for spatially-symmetric systems. These equilibria are shown to exist in the presence of non-uniform background EM fields and curved space-time. In the non-relativistic limit, this feature permits the determination of kinetic equilibria even for plasmas in which particle energy is not conserved due to the occurrence of explicitly time-dependent EM fields. Finally, absolute stability criteria are established which apply in the case of infinitesimal symmetric perturbations that can be either externally or internally produced.

79 ASTRONOMY AND ASTROPHYSICS↗

Small-angle X-ray scattering, synchrotron radiation, and the structure of bio- and nanosystems

Small-angle X-ray scattering is a universal diffraction method for studying the supra-atomic structure of matter. The potential of this technique has greatly increased in recent years due to the development of bright synchrotron radiation sources. The extensive use of these sources, in combination with new techniques for analyzing scattering data and structure modeling, made small-angle scattering one of the most effective analytical methods for studying nanoscale structures. In this review, after a brief outline of the basic principles of small-angle scattering by isotropic dispersed nanosystems, we consider two areas of nanodiagnostics, in which the progress in the small-angle experiment and the latest techniques for interpreting scattering data has become pronounced in recent years. These areas-the analysis of the structure of biological macromolecules in a solution and structural studies of metal nanoparticles synthesized in polymer and aqueous media-are illustrated by examples of practical biological and nanotechnologycal applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Parametric amplification of broadband radiation of a cw superluminescent diode under picosecond pumping

It is proposed to use cw superluminescent diodes with a spectral width of about 300 cm{sup −1} and high spatial coherence as seed radiation sources in parametric amplifiers with picosecond pumping in order to form broadband picosecond pulses. A two-cascade parametric amplifier based on BaB{sub 2}O{sub 4} (BBO) crystals is pumped by 20-ps pulses of the second harmonic of an Nd : YAG laser. For a superluminescent diode spectral width of 275 cm{sup −1} (centre wavelength 790 nm), the spectral width of picosecond pulses at the parametric amplifier output is 203 cm{sup −1}. At a total pump energy of 7.2 mJ for BBO crystals, the energy of the enhanced emission of the superluminescent diode is found to be 0.6 mJ.

42 ENGINEERING↗

High Power UV LED Industrial Curing Systems

UV curing is a green technology that is largely underutilized because UV radiation sources like Hg Lamps are unreliable and difficult to use. High Power UV LEDs are now efficient enough to replace Hg Lamps, and offer significantly improved performance relative to Hg Lamps. In this study, a modular, scalable high power UV LED curing system was designed and tested, performing well in industrial coating evaluations. In order to achieve mechanical form factors similar to commercial Hg Lamp systems, a new patent pending design was employed enabling high irradiance at long working distances. While high power UV LEDs are currently only available at longer UVA wavelengths, rapid progress on UVC LEDs and the development of new formulations designed specifically for use with UV LED sources will converge to drive more rapid adoption of UV curing technology. An assessment of the environmental impact of replacing Hg Lamp systems with UV LED systems was performed. Since UV curing is used in only a small portion of the industrial printing, painting and coating markets, the ease of use of UV LED systems should increase the use of UV curing technology. Even a small penetration of the significant number of industrial applications still using oven curing and drying will lead to significant reductions in energy consumption and reductions in the emission of green house gases and solvent emissions.

42 ENGINEERING↗

A research of W-band folded waveguide traveling wave tube with elliptical sheet electron beam

Folded waveguide (FWG) traveling wave tube (TWT), which shows advantages in high power capacity, moderate bandwidth, and low-cost fabrication, has become the focus of vacuum electronics recently. Sheet electron beam devices are better suited for producing radiation sources with large power in millimeter wave spectrum due to their characteristics of relatively low space charge fields and large transport current. A FWG TWT with elliptical sheet beam working in W-band is presented in this paper, with the analysis of its dispersion characteristics, coupling impedance, transmission properties, and interaction characteristics. A comparison is also made with the traditional FWG TWT. Simulation results lead to the conclusion that the FWG TWT with elliptical sheet beam investigated in this paper can make full use of relatively large electric fields and thus generate large output power with the same electric current density.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The cyclotron resonance in Heterostructures with the InSb/AlInSb quantum wells

The absorption of two-dimensional electrons in InSb-based quantum wells in the quantized magnetic fields in the terahertz spectral region are studied. A p-Ge-based cyclotron laser was used as the radiation source. The effective mass of carriers at the Fermi level equal to 0.0219m{sub 0} (m{sub 0} is the mass of a free electron) is determined from the cyclotron resonance spectra. It is shown that the electron spectrum is described by the Kane model in a wide range of magnetic fields. An anomalously pronounced splitting of the cyclotron resonance line not associated with the nonparabolicity of the conduction band of InAs is observed in low magnetic fields, which can be attributed to the effect of the spin-orbit interaction.

36 MATERIALS SCIENCE↗

A legacy of the ""megagoule committee,"" thirty years of explosive pulsed power research and development at Los Alamos National Laboratory

In 1980, Los Alamos formed the 'Megajoule Committee' with the expressed goal of developing a one Megajoule plasma radiation source. The ensuing research and development has given rise to a wide variety of high explosive pulsed power accomplishments, and there is a continuous stream of work that continues to the present. A variety of flux compression generators (FCGs or generators) have been designed and tested, and a number of pulse shortening schemes have been investigated. Supporting computational tools have been developed in parallel with experiments. No fewer that six unique systems have been developed and used for experiments. This paper attempts to pull together the technical details, achievements, and wisdom amassed during the intervening thirty years, and notes how we would push for increased performance in the future.

47 OTHER INSTRUMENTATION↗

Equation of state of bcc-Mo by static volume compression to 410 GPa

Unit cell volumes of Mo and Pt have been measured simultaneously to ≈400 GPa by x-ray powder diffraction using a diamond anvil cell and synchrotron radiation source. The body-centered cubic (bcc) phase of Mo was found to be stable up to 410 GPa. The equation of state (EOS) of bcc-Mo was determined on the basis of Pt pressure scale. A fit of Vinet EOS to the volume compression data gave K{sub 0} = 262.3(4.6) GPa, K{sub 0}′ = 4.55(16) with one atmosphere atomic volume V{sub 0} = 31.155(24) A{sup 3}. The EOS was in good agreement with the previous ultrasonic data within pressure difference of 2.5%–3.3% in the multimegabar range, though the EOS of Mo proposed from a shock compression experiment gave lower pressure by 7.2%–11.3% than the present EOS. The agreement would suggest that the Pt pressure scale provides an accurate pressure value in an ultra-high pressure range.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A full-field transmission x-ray microscope for time-resolved imaging of magnetic nanostructures

Sub-nanosecond magnetization dynamics of small permalloy (Ni{sub 80}Fe{sub 20}) elements has been investigated with a new full-field transmission microscope at the soft X-ray beamline P04 of the high brilliance synchrotron radiation source PETRA III. The soft X-ray microscope generates a flat-top illumination field of 20 μm diameter using a grating condenser. A tilted nanostructured magnetic sample can be excited by a picosecond electric current pulse via a coplanar waveguide. The transmitted light of the sample plane is directly imaged by a micro zone plate with < 65 nm resolution onto a 2D gateable X-ray detector to select one particular bunch in the storage ring that probes the time evolution of the dynamic information successively via XMCD spectromicroscopy in a pump-probe scheme. In the experiments it was possible to generate a homogeneously magnetized state in patterned magnetic layers by a strong magnetic Oersted field pulse of 200 ps duration and directly observe the recovery to the initial flux-closure vortex patterns.