Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quantum Error Correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Quancorde: Boosting fidelity with Quantum Canary Ordered Diverse Ensembles

On today's noisy imperfect quantum devices, execution fidelity tends to collapse dramatically for most applications beyond a handful of qubits. It is therefore imperative to employ novel techniques that can boost quantum fidelity in new ways. Here, this paper aims to boost quantum fidelity with Clifford canary circuits by proposing Quancorde: Quantum Canary Ordered Diverse Ensembles, a fundamentally newapproach to identifying the correct outcomes of extremely low-fidelity quantum applications. It is based on the key idea of diversity in quantum devices - variations in noise sources, make each (portion of a) device unique, and therefore, their impact on an application's fidelity, also unique. Quancorde utilizes Clifford canary circuits (which are classically simulable, but also resemble the target application structure and thus suffer similar structural noise impact) to order a diverse ensemble of devices or qubits/mappings approximately along the direction of increasing fidelity of the target application. Quancorde then estimates the correlation of the ensemble-wide probabilities of each output string of the application, with the canary ensemble ordering, and uses this correlation to weight the application's noisy probability distribution. The correct application outcomes are expected to have higher correlation with the canary ensemble order, and thus their probabilities are boosted in this process. Doing so, Quancorde improves the fidelity of evaluated quantum applications by a mean of 8.9x/4.2x (wrt. different baselines) and up to a maximum of 34x.

clifford↗

Solvent Dynamics Are Critical to Understanding Carbon Dioxide Dissolution and Hydration in Water

Simulations of carbon dioxide (CO 2 ) in water may aid in understanding the impact of its accumulation in aquatic environments and help advance technologies for carbon capture and utilization (via, e.g., mineralization). Quantum mechanical (QM) simulations based on static molecular models with polarizable continuum solvation poorly reproduce the energetics of CO 2 hydration to form carbonic acid in water, independent of the level of QM theory employed. Only with density-functional-theory-based molecular dynamics and rare-event sampling, followed by energy corrections based on embedded correlated wavefunction theory (in conjunction with density functional embedding theory), can a close agreement between theory and experiment be achieved. Such multilevel simulations can serve as benchmarks for simpler, less costly models, giving insight into potential errors of the latter. The strong influence of sampling/averaging over dynamical solvent configurations on the energetics stems from the difference in polarity of both the transition state and product (both polar) versus the reactant (nonpolar). When a solute undergoes a change in polarity during reaction, affecting its interaction with the solvent, careful assessment of the energetic contribution of the solvent response to this change is critical. Here, we show that static models (without structural sampling) that incorporate three explicit water molecules can yield far superior results than models with more explicit water molecules because fewer water molecules yield less configurational artifacts. Static models intelligently incorporating both explicit (molecules directly participating in the reaction) and implicit solvation, along with a proper QM theory, e.g., CCSD(T) for closed-shell systems, can close the accuracy gap between static and dynamic models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inverse bremsstrahlung absorption rate for super-Gaussian electron distribution functions including plasma screening

Here we provide analytic expressions for the effective Coulomb logarithm for inverse bremsstrahlung absorption which predict significant corrections to the Langdon effect and overall absorption rate compared to previous estimates. The calculation of the collisional absorption rate of laser energy in a plasma by the inverse bremsstrahlung mechanism usually makes the approximation of a constant Coulomb logarithm. We dispense with this approximation and instead take into account the velocity dependence of the Coulomb logarithm, leading to a more accurate expression for the absorption rate valid in both classical and quantum conditions. In contrast to previous work, the laser intensity enters into the Coulomb logarithm. In most laser-plasma interactions the electron distribution function is super-Gaussian [Langdon, Phys. Rev. Lett. 44, 575 (1980)], and we find the absorption rate under these conditions is increased by as much as ≈ 30% compared to previous estimates at low density. In many cases of interest the correction to Langdon's predicted reduction in absorption is large; for example at Z = 6 and Te = 400 eV the Langdon prediction for the absorption is in error by a factor of ≈ 2. However, we also account for the additional effect of plasma screening, which predicts a reduction in absorption by a similar amount (up to ≈ 30%). These two effects compete to determine the overall absorption, which may be increased or decreased, depending on the conditions. The corrections can be incorporated into radiation-hydrodynamics simulation codes by replacing the familiar Coulomb logarithm with an analytic expression which depends on the super-Gaussian order “M” and the screening length.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Baryon acoustic oscillations in 2D: Modeling redshift-space power spectrum from perturbation theory

We present an improved prescription for the matter power spectrum in redshift space taking proper account of both nonlinear gravitational clustering and redshift distortion, which are of particular importance for accurately modeling baryon acoustic oscillations (BAOs). Contrary to the models of redshift distortion phenomenologically introduced but frequently used in the literature, the new model includes the corrections arising from the nonlinear coupling between the density and velocity fields associated with two competitive effects of redshift distortion, i.e., Kaiser and Finger-of-God effects. Based on the improved treatment of perturbation theory for gravitational clustering, we compare our model predictions with the monopole and quadrupole power spectra of N-body simulations, and an excellent agreement is achieved over the scales of BAOs. Potential impacts on constraining dark energy and modified gravity from the redshift-space power spectrum are also investigated based on the Fisher-matrix formalism, particularly focusing on the measurements of the Hubble parameter, angular diameter distance, and growth rate for structure formation. We find that the existing phenomenological models of redshift distortion produce a systematic error on measurements of the angular diameter distance and Hubble parameter by 1%-2%, and the growth-rate parameter by {approx}5%, which would become non-negligible for future galaxy surveys. Correctly modeling redshift distortion is thus essential, and the new prescription for the redshift-space power spectrum including the nonlinear corrections can be used as an accurate theoretical template for anisotropic BAOs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Assessing the accuracy of quantum Monte Carlo and density functional theory for energetics of small water clusters

We propose a detailed study of the energetics of water clusters (H 2 O) n with n ≤ 6, comparing diffusion Monte Carlo (DMC) and approximate density functional theory (DFT) with well converged coupled-cluster benchmarks. We use the many-body decomposition of the total energy to classify the errors of DMC and DFT into 1-body, 2-body and beyond-2-body components. Using both equilibrium cluster configurations and thermal ensembles of configurations, we believe DMC to be uniformly much more accurate than DFT, partly because some of the approximate functionals give poor 1-body distortion energies. Even when these are corrected, DFT remains considerably less accurate than DMC. When both 1- and 2-body errors of DFT are corrected, some functionals compete in accuracy with DMC; however, other functionals remain worse, demonstrating that they suffer from significant beyond-2-body errors. Combining the evidence presented here with the recently demonstrated high accuracy of DMC for ice structures, we suggest how DMC can now be used to provide benchmarks for larger clusters and for bulk liquid water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evolution of the Kondo lattice electronic structure above the transport coherence temperature

Significance The temperature ( T )-dependent evolution of the Kondo lattice electronic structure is a long-standing topic of theoretical and experimental investigation, still lacking a truly microscopic theory that agrees with a full experimental characterization. Here multiple characteristic T scales of the interaction of localized f moments with conduction electrons in the Kondo lattice CeCo I n 5 are identified and investigated using angle-resolved photoemission measurements that substantiate dynamical mean-field theory which newly includes the full realism of crystalline electric-field (CEF) f splittings. Thereby errors in the itinerant versus localized f -state classification from standard density functional theory are corrected, microscopic insight into the broad T -range crossover of f -hybridization effects is gained, and a prediction of CEF degeneracy crossover below the lattice coherence T is made.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comment on "Continuum Lowering and Fermi-Surface Rising in Stromgly Coupled and Degenerate Plasmas"

In a recent Letter, Hu [1] reported photon absorption cross sections in strongly coupled, degenerate plasmas from quantum molecular dynamics (QMD). The Letter claims that the K-edge shift as a function of plasma density computed with simple ionization potential depression (IPD) models are in violent disagreement with the QMD results. The QMD calculations displayed an increase in Kedge shift with increasing density while the simpler models yielded a decrease. Here, this Comment shows that the claimed large errors reported by Hu for the widely used Stewart- Pyatt (SP) model [2] stem from an invalid comparison of disparate physical quantities and is largely resolved by including well-known corrections for degenerate systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monte Carlo MP2-F12 for Noncovalent Interactions: The C 60 Dimer

A scalable stochastic algorithm is presented that can evaluate explicitly correlated (F12) second-order many-body perturbation (MP2) energies of weak, noncovalent, intermolecular interactions. It first transforms the formulas of the MP2 and F12 energy differences into a short sum of high-dimensional integrals of Green’s functions in real space and imaginary time. Furthermore, these integrals are then evaluated by the Monte Carlo method augmented by parallel execution, redundant-walker convergence acceleration, direct-sampling autocorrelation elimination, and control-variate error reduction. By sharing electron-pair walkers across the supermolecule and its subsystems spanned by the joint basis set, the statistical uncertainty is reduced by one to 2 orders of magnitude in the MP2 binding energy corrected for the basis-set incompleteness and superposition errors. The method predicts the MP2-F12/aug-cc-pVDZ binding energy of 19.1 ± 4.0 kcal mol –1 for the C 60 dimer at the center distance of 9.748 Å.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimal Countrates for Deadtime Corrections

The high x-ray flux available at synchrotron radiation sources can cause nonlinearities in photon-counting detectors unless deadtime corrections are employed. We compute the uncertainties associated with several common deadtime-correction formulas. At lower countrates, statistical noise dominates the error in the measured countrates; at higher countrates, the dominating factors are saturation of the response and uncertainty in the value of the deadtime parameter. In between, a range of countrates exists in which the signal-to-noise ratio can be optimized for photon-counting experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Density functional theory and chromium: Insights from the dimers

The binding in small Cr clusters is re-investigated, where the correct description of the dimer in three charge states is used as criterion to assign the most suitable density functional theory approximation. The difficulty in chromium arises from the subtle interplay between energy gain from hybridization and energetic cost due to exchange between s and d based molecular orbitals. Variations in published bond lengths and binding energies are shown to arise from insufficient numerical representation of electron density and Kohn-Sham wave-functions. The best functional performance is found for gradient corrected (GGA) functionals and meta-GGAs, where we find severe differences between functionals from the same family due to the importance of exchange. Only the “best fit” from Bayesian error estimation is able to predict the correct energetics for all three charge states unambiguously. With this knowledge, we predict small bond-lengths to be exclusively present in Cr{sub 2} and Cr{sub 2}{sup −}. Already for the dimer cation, solely long bond-lengths appear, similar to what is found in the trimer and in chromium bulk.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nano-metrology: The art of measuring X-ray mirrors with slope errors <100 nrad

We present a comprehensive investigation of the systematic and random errors of the nano-metrology instruments used to characterize synchrotron X-ray optics at Diamond Light Source. With experimental skill and careful analysis, we show that these instruments used in combination are capable of measuring state-of-the-art X-ray mirrors. Examples are provided of how Diamond metrology data have helped to achieve slope errors of <100 nrad for optical systems installed on synchrotron beamlines, including: iterative correction of substrates using ion beam figuring and optimal clamping of monochromator grating blanks in their holders. Simulations demonstrate how random noise from the Diamond-NOM’s autocollimator adds into the overall measured value of the mirror’s slope error, and thus predict how many averaged scans are required to accurately characterize different grades of mirror.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Convective heat transfer in a high aspect ratio minichannel heated on one side

Experimental results are presented for single-phase heat transfer in a narrow rectangular minichannel heated on one side. The aspect ratio and gap thickness of the test channel were 29:1 and 1.96 mm, respectively. Friction pressure drop and Nusselt numbers are reported for the transition and fully turbulent flow regimes, with Prandtl numbers ranging from 2.2 to 5.4. Turbulent friction pressure drop for the high aspect ratio channel is well-correlated by the Blasius solution when a modified Reynolds number, based upon a laminar equivalent diameter, is utilized. The critical Reynolds number for the channel falls between 3500 and 4000, with Nusselt numbers in the transition regime being reasonably predicted by Gnielinski's correlation. The dependence of the heat transfer coefficient on the Prandtl number is larger than that predicted by circular tube correlations, and is likely a result of the asymmetric heating. The problem of asymmetric heating condition is approached theoretically using a boundary layer analysis with a two-region wall layer model, similar to that originally proposed by Prandtl. The analysis clarifies the influence of asymmetric heating on the Nusselt number and correctly predicts the experimentally observed trend with Prandtl number. Furthermore, a semi-analytic correlation is derived from the analysis that accounts for the effect of aspect ratio and asymmetric heating, and is shown to predict the experimental results of this study with a mean absolute error (MAE) of less than 5% for 4000 < Re < 70,000.

42 ENGINEERING↗

Embedded Model Error Representation for Bayesian Model Calibration

Model error estimation remains one of the key challenges in uncertainty quantification and predictive science. For computational models of complex physical systems, model error, also known as structural error or model inadequacy, is often the largest contributor to the overall predictive uncertainty. This work builds on a recently developed framework of embedded, internal model correction, in order to represent and quantify structural errors, together with model parameters,within a Bayesian inference context. We focus specifically on a Polynomial Chaos representation with additive modification of existing model parameters, enabling a non-intrusive procedure for efficient approximate likelihood construction, model error estimation, and disambiguation of model and data errors’ contributions to predictive uncertainty. The framework is demonstrated on several synthetic examples, as well as on a chemical ignition problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enthalpy Diffusion in Multicomponent Flows

The conclusions of this paper are: (1) Enthalpy diffusion preserves the second law. (2) Euler solvers will not produce correct temperatures in mixing regions. (3) Navier-Stokes solvers will only produce correct temperatures if q{sub d} is included. (4) Errors from neglecting enthalpy diffusion are most severe when differences in molecular weights are large. (5) In addition to temperature, enthalpy diffusion affects density, dilatation and other fields in subtle ways. (6) Reacting flow simulations that neglect the term are a dubious proposition. (7) Turbulence models for RANS and LES closures should preserve consistency between energy and species diffusion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A linearity preserving nodal variation limiting algorithm for continuous Galerkin discretization of ideal MHD equations

A stabilized continuous Galerkin (CG) method for magnetohydrodynamics (MHD) is presented herein. Ideal, compressible inviscid MHD equations are discretized in space on unstructured meshes using piecewise linear or bilinear finite element bases to get a semi-discrete scheme. Stabilization is then introduced to the semi-discrete method in a strategy that follows the algebraic flux correction paradigm. This involves adding some artificial diffusion to the high order, semi-discrete method and mass lumping in the time derivative term. The result is a low order method that provides local extremum diminishing properties for hyperbolic systems. The difference between the low order method and the high order method is scaled element-wise using a limiter and added to the low order scheme. The limiter is solution dependent and computed via an iterative linearity preserving nodal variation limiting strategy. The stabilization also involves an optional consistent background high order dissipation that reduces phase errors. The resulting stabilized scheme is a semi-discrete method that can be applied to inviscid shock MHD problems and may be even extended to resistive and viscous MHD problems. To satisfy the divergence free constraint of the MHD equations, we add parabolic divergence cleaning to the system. Various time integration methods can be used to discretize the scheme in time. We demonstrate the robustness of the scheme by solving several shock MHD problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An ab initio investigation of possible intermediates in the reaction of the hydroxyl and hydroperoxyl radicals

Ab initio quantum chemical techniques are used to investigate covalently-bonded and hydrogen-bonded species that may be important intermediates in the reaction of hydroxyl and hydroperoxyl radicals. Stable structures of both types are identified. Basis sets of polarized double zeta quality and large scale configuration interaction wave functions are utilized. Based on electronic energies, the covalently bonded HOOOH species is 26.4 kcal/mol more stable than the OH and HO2 radicals. Similarly, the hydrogen bonded HO---HO2 species has an electronic energy 4.7 kcal/mol below that of the component radicals, after correction is made for the basis set superposition error. The hydrogen bonded form is planar, possesses one relatively normal hydrogen bond, and has the lowest energy 3A' and 1A' states that are essentially degenerate. The 1A" and 3A" excited states produced by rotation of the unpaired OH electron into the molecular plane are very slightly bound.

Jackels, C. F.↗

Validation of a treatment plan-based calibration method for 2D detectors used for treatment delivery quality assurance

Purpose: Dosimetry using film, CR, electronic portal imaging, or other 2D detectors requires calibration of the raw image data to obtain dose. Typically, a series of known doses are given to the detector, the raw signal for each dose is obtained, and a calibration curve is created. This calibration curve is then applied to the measured raw signals to convert them to dose. With the advent of IMRT, film dosimetry for quality assurance has become a routine and labor intensive part of the physicist's day. The process of calibrating the film or other 2D detector takes time and additional film or images for performing the calibration, and comes with its own source of errors. This article studies a new methodology for the relative dose calibration of 2D imaging detectors especially useful for IMRT QA, which relies on the treatment plan dose image to provide the dose information which is paired with the raw QA image data after registration of the two images (plan-based calibration). Methods: Validation of the accuracy and robustness of the method is performed on ten IMRT cases performed using EDR2 film with conventional and plan-based calibration. Also, for each of the ten cases, a 5 mm registration error was introduced and the Gamma analysis was reevaluated. In addition, synthetic image tests were performed to test the limits of the method. The Gamma analysis is used as a measure of dosimetric agreement between plan and film for the clinical cases and a dose difference metric for the synthetic cases. Results: The QA image calibrated by the plan-based method was found to more accurately match the treatment plan doses than the conventionally calibrated films and also to reveal dose errors more effectively when a registration error was introduced. When synthetic acquired images were systematically studied, localized and randomly placed dose errors were correctly identified without excessive falsely passing or falsely failing pixels, unless the errors were concentrated in a majority of pixels in a contiguous narrow dose band. Irregularities seen in the calibration curve expose these errors. Conclusions: The plan-based calibration method was found to be an accurate, efficient procedure, capable of detecting IMRT QA relative dosimetry errors as well as, or better than conventional calibration methods.

07 ISOTOPE AND RADIATION SOURCES↗