Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quality Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Theorising EIA effectiveness: A contribution based on the Danish system

Considerable attention has been given to the effectiveness of environmental impact assessment (EIA) since the 1970s. Relatively few research studies, however, have approached EIA as an instrument of environmental governance, and have explored the mechanisms through which EIA influences the behaviour of actors involved in planning processes. Consequently, theory in this area is underspecified. In this paper we contribute to theory-building by analysing the effectiveness of a unique EIA system: the Danish system. In this system the competent authority, instead of the project proponent, undertakes EIA reporting. Additionally, the public, rather than experts, play a central role in quality control and the Danish EIA community is relatively small which influences community dynamics in particular ways. A nation-wide survey and expert interviews were undertaken in order to examine the views of actors involved in EIA on the effectiveness of this anomalous system. The empirical data are compared with similar studies on governance mechanisms in other countries, especially the United Kingdom and the Netherlands, as well as with earlier evaluations of EIA effectiveness in Denmark. The results indicate that the more extensive role attributed to the competent authority may lead to higher EIA effectiveness when this aligns with their interests; the influence of the public is amplified by a powerful complaints system; and, the size of the EIA community appears to have no substantial influence on EIA effectiveness. We discuss how the research findings might enhance our theoretical understanding of the operation and effectiveness of governance mechanisms in EIA. - Highlights: • The effectiveness of the unique Danish EIA system is explored. • Results are compared with similar studies in the Netherlands and the UK. • Findings lead to hypotheses that contribute to theorising EIA effectiveness.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Aerial Radiological Survey of Selected Areas of the City of North Las Vegas

As part of the proficiency training for the Radiological Mapping mission of the Aerial Measuring System (AMS), a survey team from the Remote Sensing Laboratory-Nellis (RSL-Nellis) conducted an aerial radiological survey of selected areas of the city of North Las Vegas for the purpose of mapping natural radiation background and locating any man-made radioactive sources. Survey areas were selected in collaboration with the City Manager's office and included four separate areas: (1) Las Vegas Motor Speedway (10.6 square miles); (2) North Las Vegas Downtown Area (9.2 square miles); (3) I-15 Industrial Corridor (7.4 square miles); and (4) Future site of University of Nevada Las Vegas campus (17.4 square miles). The survey was conducted in three phases: Phase 1 on December 11-12, 2007 (Areas 1 and 2), Phase 2 on February 28, 2008 (Area 3), and Phase 3 on March 19, 2008 (Area 4). The total completed survey covered a total of 44.6 square miles. The flight lines (without the turns) over the surveyed areas are presented in Figures 1, 2, 3, and 4. A total of eight 2.5-hour-long flights were performed at an altitude of 150 ft above ground level (AGL) with 300 feet of flight-line spacing. Water line and test line flights were conducted over the Lake Mead and Government Wash areas to ensure quality control of the data. The data were collected by the AMS data acquisition system (REDAR V) using an array of twelve 2-inch x 4-inch x 16-inch sodium iodide (NaI) detectors flown on-board a twin-engine Bell 412 helicopter. Data, in the form of gamma energy spectra, were collected continually (every second) over the course of the survey and were geo-referenced using a differential Global Positioning System. Collection of spectral data allows the system to distinguish between ordinary fluctuations in natural background radiation levels and the signature produced by man-made radioisotopes. Spectral data can also be used to identify specific radioactive isotopes. As a courtesy service, with the approval of the U.S. Department of Energy, National Nuclear Security Administration, Nevada Site Office, RSL-Nellis is providing this summary to the office of the Mayor of the City of North Las Vegas along with the gross-count-based exposure rate and man-made count contour maps and GIS shape files in electronic format on a compact disk.

54 ENVIRONMENTAL SCIENCES↗

Challenges in Credentialing Institutions and Participants in Advanced Technology Multi-institutional Clinical Trials

The Radiological Physics Center (RPC) has functioned continuously for 38 years to assure the National Cancer Institute and the cooperative groups that institutions participating in multi-institutional trials can be expected to deliver radiation treatments that are clinically comparable to those delivered by other institutions in the cooperative groups. To accomplish this, the RPC monitors the machine output, the dosimetry data used by the institutions, the calculation algorithms used for treatment planning, and the institutions' quality control procedures. The methods of monitoring include on-site dosimetry review by an RPC physicist and a variety of remote audit tools. The introduction of advanced technology clinical trials has prompted several study groups to require participating institutions and personnel to become credentialed, to ensure their familiarity and capability with techniques such as three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, stereotactic body radiotherapy, and brachytherapy. The RPC conducts a variety of credentialing activities, beginning with questionnaires to evaluate an institution's understanding of the protocol and their capabilities. Treatment-planning benchmarks are used to allow the institution to demonstrate their planning ability and to facilitate a review of the accuracy of treatment-planning systems under relevant conditions. The RPC also provides mailable anthropomorphic phantoms to verify tumor dose delivery for special treatment techniques. While conducting these reviews, the RPC has amassed a large amount of data describing the dosimetry at participating institutions. Representative data from the monitoring programs are discussed, and examples are presented of specific instances in which the RPC contributed to the discovery and resolution of dosimetry errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of linear accelerator performance standards using an outcome oriented approach

Radiation therapy, along with other branches of medicine, is moving towards a firmer basis in evidence to optimally utilize resources. As new treatment technology and strategies place greater demands on quality assurance resources, the need to objectively evaluate equipment and process performance standards from the perspective of predicted clinical impact becomes more urgent. This study evaluates the appropriateness of recommended quality control tolerance and action levels for linear accelerators based on the calculated dosimetric impact of suboptimal equipment performance. A method is described to quantify the dosimetric changes, as reflected by the changes in the outcome surrogate, equivalent uniform dose (EUD), of machine performance deviations from the optimal, specifically in the range of tolerance and action levels promulgated by the Canadian Association of Provincial Cancer Agencies (CAPCA). Linear accelerator performance deviations were simulated for the treatment of prostate, breast, lung, and brain using 3D conformal techniques, and the impact evaluated in terms of the changes in the EUD of the target volumes and two principal organs at risk (OARs) per site. The eight key performance characteristics examined are: Output constancy, beam flatness, gantry angle, collimator angle, field size indicator, laser alignment (three directions) and, by inference, the optical distance indicator. Currently accepted CAPCA tolerance levels for these eight performance characteristics are shown to maintain average EUD deviations to within 2% for the targets and 2 Gy for the OARs. However, within the 2% or 2 Gy range, the recommended tolerance levels are found to have markedly different effects on the EUDs of the structures of interest.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assembling the Marine Metagenome, One Cell at a Time

The difficulty associated with the cultivation of most microorganisms and the complexity of natural microbial assemblages, such as marine plankton or human microbiome, hinder genome reconstruction of representative taxa using cultivation or metagenomic approaches. Here we used an alternative, single cell sequencing approach to obtain high-quality genome assemblies of two uncultured, numerically significant marine microorganisms. We employed fluorescence-activated cell sorting and multiple displacement amplification to obtain hundreds of micrograms of genomic DNA from individual, uncultured cells of two marine flavobacteria from the Gulf of Maine that were phylogenetically distant from existing cultured strains. Shotgun sequencing and genome finishing yielded 1.9 Mbp in 17 contigs and 1.5 Mbp in 21 contigs for the two flavobacteria, with estimated genome recoveries of about 91percent and 78percent, respectively. Only 0.24percent of the assembling sequences were contaminants and were removed from further analysis using rigorous quality control. In contrast to all cultured strains of marine flavobacteria, the two single cell genomes were excellent Global Ocean Sampling (GOS) metagenome fragment recruiters, demonstrating their numerical significance in the ocean. The geographic distribution of GOS recruits along the Northwest Atlantic coast coincided with ocean surface currents. Metabolic reconstruction indicated diverse potential energy sources, including biopolymer degradation, proteorhodopsin photometabolism, and hydrogen oxidation. Compared to cultured relatives, the two uncultured flavobacteria have small genome sizes, few non-coding nucleotides, and few paralogous genes, suggesting adaptations to narrow ecological niches. These features may have contributed to the abundance of the two taxa in specific regions of the ocean, and may have hindered their cultivation. We demonstrate the power of single cell DNA sequencing to generate reference genomes of uncultured taxa from a complex microbial community of marine bacterioplankton. A combination of single cell genomics and metagenomics enabled us to analyze the genome content, metabolic adaptations, and biogeography of these taxa.

99 GENERAL AND MISCELLANEOUS↗

Reactive impinging-flow technique for polymer-electrolyte-fuel-cell electrode-defect detection

Reactive impinging flow (RIF) is a novel quality-control method for defect detection (i.e., reduction in Pt catalyst loading) in gas-diffusion electrodes (GDEs) on weblines. The technique uses infrared thermography to detect temperature of a nonflammable (<4% H 2 ) reactive mixture of H 2 /O 2 in N 2 impinging and reacting on a Pt catalytic surface. In this article, different GDE size defects (with catalyst-loading reductions of 25, 50, and 100%) are detected at various webline speeds (3.048 and 9.144 m min -1 ) and gas flowrates (32.5 or 50 standard L min -1 ). Furthermore, a model is developed and validated for the technique, and it is subsequently used to optimize operating conditions and explore the applicability of the technique to a range of defects. The model suggests that increased detection can be achieved by recting more of the impinging H 2 , which can be accomplished by placing blocking substrates on the top, bottom, or both of the GDE; placing a substrate on both results in a factor of four increase in the temperature differential, which is needed for smaller defect detection. Lastly, overall, the RIF technique is shown to be a promising route for in-line, high-speed, large-area detection of GDE defects on moving weblines.

30 DIRECT ENERGY CONVERSION↗

Effects of pH and Iminosugar Pharmacological Chaperones on Lysosomal Glycosidase Structure and Stability

Human lysosomal enzymes acid-{beta}-glucosidase (GCase) and acid-{alpha}-galactosidase ({alpha}-Gal A) hydrolyze the sphingolipids glucosyl- and globotriaosylceramide, respectively, and mutations in these enzymes lead to the lipid metabolism disorders Gaucher and Fabry disease, respectively. We have investigated the structure and stability of GCase and {alpha}-Gal A in a neutral-pH environment reflective of the endoplasmic reticulum and an acidic-pH environment reflective of the lysosome. These details are important for the development of pharmacological chaperone therapy for Gaucher and Fabry disease, in which small molecules bind mutant enzymes in the ER to enable the mutant enzyme to meet quality control requirements for lysosomal trafficking. We report crystal structures of apo GCase at pH 4.5, at pH 5.5, and in complex with the pharmacological chaperone isofagomine (IFG) at pH 7.5. We also present thermostability analysis of GCase at pH 7.4 and 5.2 using differential scanning calorimetry. We compare our results with analogous experiments using {alpha}-Gal A and the chaperone 1-deoxygalactonijirimycin (DGJ), including the first structure of {alpha}-Gal A with DGJ. Both GCase and {alpha}-Gal A are more stable at lysosomal pH with and without their respective iminosugars bound, and notably, the stability of the GCase-IFG complex is pH sensitive. We show that the conformations of the active site loops in GCase are sensitive to ligand binding but not pH, whereas analogous galactose- or DGJ-dependent conformational changes in {alpha}-Gal A are not seen. Thermodynamic parameters obtained from {alpha}-Gal A unfolding indicate two-state, van't Hoff unfolding in the absence of the iminosugar at neutral and lysosomal pH, and non-two-state unfolding in the presence of DGJ. Taken together, these results provide insight into how GCase and {alpha}-Gal A are thermodynamically stabilized by iminosugars and suggest strategies for the development of new pharmacological chaperones for lysosomal storage disorders.

36 MATERIALS SCIENCE↗

The Worldwide C3S CORDEX Grand Ensemble: A Major Contribution to Assess Regional Climate Change in the IPCC AR6 Atlas

The collaboration between the Coordinated Regional Climate Downscaling Experiment (CORDEX) and the Earth System Grid Federation (ESGF) provides open access to an unprecedented ensemble of regional climate model (RCM) simulations, across the 14 CORDEX continental-scale domains, with global coverage. These simulations have been used as a new line of evidence to assess regional climate projections in the latest contribution of the Working Group I (WGI) to the IPCC Sixth Assessment Report (AR6), particularly in the regional chapters and the Atlas. Here, we present the work done in the framework of the Copernicus Climate Change Service (C3S) to assemble a consistent worldwide CORDEX grand ensemble, aligned with the deadlines and activities of IPCC AR6. This work addressed the uneven and heterogeneous availability of CORDEX ESGF data by supporting publication in CORDEX domains with few archived simulations and performing quality control. It also addressed the lack of comprehensive documentation by compiling information from all contributing regional models, allowing for an informed use of data. In addition to presenting the worldwide CORDEX dataset, we assess here its consistency for precipitation and temperature by comparing climate change signals in regions with overlapping CORDEX domains, obtaining overall coincident regional climate change signals. The C3S CORDEX dataset has been used for the assessment of regional climate change in the IPCC AR6 (and for the interactive Atlas) and is available through the Copernicus Climate Data Store (CDS).

54 ENVIRONMENTAL SCIENCES↗

Plasma-Based Ambient Desorption/Ionization Mass Spectrometry for the Analysis of Liquid Crystals Employed in Display Devices

Liquid-crystal displays (LCDs) are the most frequently used display technology worldwide these days. Due to the rather complex manufacturing process and purity requirements for the chemicals used, quality control and display failure analysis are important analytical tasks. Currently, the state-of-the-art techniques (e.g., high-performance liquid chromatography (HPLC), gas chromatography (GC) coupled to mass spectrometry (MS), time-of-flight secondary ion mass spectrometry (TOF-SIMS), or high-resolution microscopy) are costly and time-consuming. Hence, a new pathway to precisely analyze liquid-crystalline materials and LCDs in their native state is reported. A new approach for direct analysis via plasma-based ambient desorption/ionization mass spectrometry (ADI-MS) offers an inexpensive and faster alternative. In this study, direct analysis in real time (DART), the low-temperature plasma (LTP) probe, and flowing atmospheric-pressure afterglow (FAPA) ADI sources coupled to high-resolution mass spectrometry (HR-MS) are compared based on their capabilities and performance for liquid-crystal analysis. These sources enable direct analyte desorption from a sample surface at ambient conditions and ionize the vaporized analyte molecules in a subsequent step. Primarily, the ionization capabilities of the three ADI sources are compared for individual liquid-crystal standards, mixtures of liquid crystals (LCs), and complex liquid crystal/additive mixtures applied in commercially available LCDs. Furthermore, direct surface analysis from a glass substrate is also performed with ADI-MS to compare their applicability to this type of sample matrix. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-I-41: Non-Cartesian MR Image Reconstruction with Integrated Gradient Non-Linearity Correction

Purpose: Nonlinearities in the spatial encoding gradients of MRI systems cause geometric distortion in images. Typically, this is retrospectively corrected via image-domain interpolation (a.k.a., “gradwarp”) albeit with a loss of spatial resolution. For non-Cartesian MRI, the latter problem is exaggerated by noise and undersampling artifact. In this study, we describe a novel correction strategy that accounts for gradient nonlinearities during — rather than after — non-Cartesian MRI reconstruction, and demonstrate that this approach mitigates the resolution loss that can occur with standard methods. Methods: To test the proposed method, the American College of Radiology (ACR) quality control phantom was scanned on at 1.5 T (General Electric, v16.0, “zoom” gradient) using a 1.6x undersampled 3D non- Cartesian Shells trajectory (GRE, FOV=24 cm3, 120 shells, 16552 shots, 512 readout, matrix=2403). Image reconstruction was first performed via standard k-space density-compensated gridding and retrospectively corrected via cubic spline interpolation. Image reconstruction was then separately performed using a k-space and image-domain densitycompensated type-3 non-uniform fast Fourier transform (NUFFT), which provides a direct mapping between non-Cartesian k-space samples and warped image space voxel locations. Thus, no separate distortion correction procedure is needed for the proposed approach. The gradient distortion field was determined using vendor provided calibration data. Results: Phantom scan results show that both processing approaches successfully correct geometric distortion. However, visual inspection of the ACR phantom spatial resolution inserts shows that the proposed strategy preserves the resolution of the nominal (uncorrected) reconstruction while “gradwarp” imparts marked spatial blurring (especially for the 1.0 and 1.1 mm inserts) and thus resolution loss. Conclusion: We've presented a novel reconstruction strategy for non-Cartesian MRI that corrects for gradient nonlinearities during — rather than after — reconstruction, and thus better preserves image resolution than traditional interpolation-based methods. This approach is expected to be especially advantageous when imaging with non-standard magnet geometries. NIH RR018898; NIH EB10065.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental and Sampling Design for the INL-2 Sample Collection Operational Test

This report describes the experimental and sampling design developed to assess sampling approaches and methods for detecting contamination in a building and clearing the building for use after decontamination. An Idaho National Laboratory (INL) building will be contaminated with BG (Bacillus globigii, renamed Bacillus atrophaeus), a simulant for Bacillus anthracis (BA). The contamination, sampling, decontamination, and re-sampling will occur per the experimental and sampling design. This INL-2 Sample Collection Operational Test is being planned by the Validated Sampling Plan Working Group (VSPWG). The primary objectives are: 1) Evaluate judgmental and probabilistic sampling for characterization as well as probabilistic and combined (judgment and probabilistic) sampling approaches for clearance, 2) Conduct these evaluations for gradient contamination (from low or moderate down to absent or undetectable) for different initial concentrations of the contaminant, 3) Explore judgment composite sampling approaches to reduce sample numbers, 4) Collect baseline data to serve as an indication of the actual levels of contamination in the tests. A combined judgmental and random (CJR) approach uses Bayesian methodology to combine judgmental and probabilistic samples to make clearance statements of the form "X% confidence that at least Y% of an area does not contain detectable contamination” (X%/Y% clearance statements). The INL-2 experimental design has five test events, which 1) vary the floor of the INL building on which the contaminant will be released, 2) provide for varying the amount of contaminant released to obtain desired concentration gradients, and 3) investigate overt as well as covert release of contaminants. Desirable contaminant gradients would have moderate to low concentrations of contaminant in rooms near the release point, with concentrations down to zero in other rooms. Such gradients would provide a range of contamination levels to challenge the sampling, sample extraction, and analytical methods to be used in the INL-2 study. For each of the five test events, the specified floor of the INL building will be contaminated with BG using a point-release device located in the room specified in the experimental design. Then quality control (QC), reference material coupon (RMC), judgmental, and probabilistic samples will be collected according to the sampling plan for each test event. Judgmental samples will be selected based on professional judgment and prior information. Probabilistic samples were selected with a random aspect and in sufficient numbers to provide desired confidence for detecting contamination or clearing uncontaminated (or decontaminated) areas. Following sample collection for a given test event, the INL building will be decontaminated. For possibly contaminated areas, the numbers of probabilistic samples were chosen to provide 95% confidence of detecting contaminated areas of specified sizes. For rooms that may be uncontaminated following a contamination event, or for whole floors after decontamination, the numbers of judgmental and probabilistic samples were chosen using the CJR approach. The numbers of samples were chosen to support making X%/Y% clearance statements with X = 95% or 99% and Y = 96% or 97%. The experimental and sampling design also provides for making X%/Y% clearance statements using only probabilistic samples. For each test event, the numbers of characterization and clearance samples were selected within limits based on operational considerations while still maintaining high confidence for detection and clearance aspects. The sampling design for all five test events contains 2085 samples, with 1142 after contamination and 943 after decontamination. These numbers include QC, RMC, judgmental, and probabilistic samples. The experimental and sampling design specified in this report provides a good statistical foundation for achieving the objectives of the INL-2 study.

59 BASIC BIOLOGICAL SCIENCES↗

Fluorescence imaging of viscous materials in the ultraviolet-visible wavelength range

This paper presents an approach of an innovative measurement principle for the quality control of viscous materials during a manufacturing process based on fluorescence imaging. The main contribution to the state of the art provided by this measurement system is that three equal fluorescence images of a static or moving viscous object are available in different optical paths. The independent images are obtained by two beam splitters which are connected in series. Based on these images, it is possible to evaluate each image separately. In our case, three optical bandpass filters with different center wavelengths of 405 nm, 420 nm, and 440 nm were used to filter the separate fluorescence images. The developed system is useable for the detection of impurities in the micrometer range. Further, incorrect mixing ratios of particular components and wrong single components in the viscous materials can be detected with the setup. Moreover, it is possible to realize static and dynamic measurements. In this case the maximum speed of the objects was 0.2 m/s for the dynamic measurements. Advantages of this measurement setup are the universality due to the use of optical standard components, the small dimension and the opportunity to integrate it easily into ongoing processes. In addition, the measurement system works on a non-contact basis. Thus, the expense for maintenance is at a very low level compared to currently available measurement setups for the investigated application. Furthermore, the setup provides for the first time a simultaneous analysis of more than one component and the detection of impurities concerning their nature and size in a manufacturing process.

36 MATERIALS SCIENCE↗

WE-FG-207B-10: Dual-Energy CT Monochromatic Image Consistency Across Vendors and Platforms

Purpose: Although dual-energy CT provides improved sensitivity of HU for certain tissue types at lower simulated energy levels, if these values vary by scanner type they may impact clinical patient management decisions. Each manufacturer has selected a specific dual-energy CT approach (or in one case, three different approaches); understanding HU variability among low monochromatic images may be required when more than one dual-energy CT scanner type is available for use. Methods: A large elliptical dualenergy quality control phantom (Gammex Inc.; Middleton, WI) containing several standard tissue type materials was scanned at least three times on each of the following systems: GE HD750, prototype GE Revolution CT with GSI, Siemens Flash, Siemens Edge, Siemens AS 128, and Philips IQon. Images were generated at 50, 70, and 140 keV. Soft tissue and Iodine HU were measured on a single central 5mm-thick image; NIST constants were used to calculate the ideal HU for each material. Scan acquisitions were approximately dose-matched (∼25mGy CTDIvol) and image parameters were held as consistent as possible (thickness, kernel, no noise reduction). Results: Measured soft tissue (29 HU at 120 kVp) varied from 28 HU to 44 HU at 50 keV (excluding one outlier), from 21 HU to 31 HU at 70 keV, and from 19 HU to 32 HU at 140 keV. Measured iodine (5mg/ml, 106 HU at 120 kVp) varied from 246 HU to 280 HU at 50 keV, from 123 HU to 129 HU at 70 keV, and from 22 HU to 32 HU at 140 keV. Conclusion: Measured HU in standard rods across 3 dual-energy CT manufacturers and 6 scanner models varied directly with monochromatic level, with the most variability was observed at 50 keV and least variability at 70keV. Future work will include additional scanner platforms and how measurement variability impacts radiologists. This research has been supported by funds from Dr. William Murphy, Jr., the John S. Dunn, Sr. Distinguished Chair in Diagnostic Imaging at MD Anderson Cancer Center.

60 APPLIED LIFE SCIENCES↗

Ubiquitination of specific mitochondrial matrix proteins

Several protein quality control systems in bacteria and/or mitochondrial matrix from lower eukaryotes are absent in higher eukaryotes. These are transfer-messenger RNA (tmRNA), The N-end rule ATP-dependent protease ClpAP, and two more ATP-dependent proteases, HslUV and ClpXP (in yeast). The lost proteases resemble the 26S proteasome and the role of tmRNA and the N-end rule in eukaryotic cytosol is performed by the ubiquitin proteasome system (UPS). Therefore, we hypothesized that the UPS might have substituted these systems – at least partially – in the mitochondrial matrix of higher eukaryotes. Using three independent experimental approaches, we demonstrated the presence of ubiquitinated proteins in the matrix of isolated yeast mitochondria. First, we show that isolated mitochondria contain ubiquitin (Ub) conjugates, which remained intact after trypsin digestion. Second, we demonstrate that the mitochondrial soluble fraction contains Ub-conjugates, several of which were identified by mass spectrometry and are localized to the matrix. Third, using immunoaffinity enrichment by specific antibodies recognizing digested ubiquitinated peptides, we identified a group of Ub-modified matrix proteins. The modification was further substantiated by separation on SDS-PAGE and immunoblots. Last, we attempted to identify the ubiquitin ligase(s) involved, and identified Dma1p as a trypsin-resistant protein in our mitochondrial preparations. Taken together, these data suggest a yet undefined role for the UPS in regulation of the mitochondrial matrix proteins. -- Highlights: •Mitochondrial matrix contains ubiquitinated proteins. •Ubiquitination occurs most probably in the matrix. •Dma1p is a ubiquitin ligase present in mitochondrial preparations.

60 APPLIED LIFE SCIENCES↗

Test and extraction methods for the QC parameters of silicon strip sensors for ATLAS upgrade tracker

The Quality Control (QC) of pre-production strip sensors for the Inner Tracker (ITk) of the ATLAS Inner Detector upgrade has finished, and the collaboration has embarked on the QC test programme for production sensors. This programme will last more than 3 years and comprises the evaluation of approximately 22000 sensors. 8 Types of sensors, 2 barrel and 6 endcap, will be measured at many different collaborating institutes. The sustained throughput requirement of the combined QC processes is around 500 sensors per month in total. Measurement protocols have been established and acceptance criteria have been defined in accordance with the terms agreed with the supplier. For effective monitoring of test results, common data file formats have been agreed upon across the collaboration. To enable evaluation of test results produced by many different test setups at the various collaboration institutes, common algorithms have been developed to collate, evaluate, plot and upload measurement data. This allows for objective application of pass/fail criteria and compilation of corresponding yield data. These scripts have been used to process the data of more than 3000 sensors so far, and have been instrumental for identification of faulty sensors and monitoring of QC testing progress.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Establishing an acoustic-property relationship in laser powder bed fusion with machine learning

Quality control of Laser Powder Bed Fusion (PBF-LB) additively manufactured parts is an important hurdle inhibiting the technology’s use structural applications. Acoustic monitoring of the laser powder bed fusion process can detect defects in-situ that are known to degrade mechanical properties. However, processing-structure-property (PSP) relationships are required to extrapolate from detected defects to part performance. Here, this study explores how acoustics may be a suitable signature linking processing conditions to properties, thus effectively substituting for structure in the PSP relationship. Establishing such a relationship would enable a part’s mechanical performance to be directly predicted from its acoustic signature, reducing the need for destructive testing or microstructural analysis to ensure a part will meet performance requirements. One hundred CoCrFeMnNi high entropy alloy tensile bars were printed across 13 process conditions in a series of 6 prints. The acoustic signatures of these tensile bars were used to train machine learning models to predict each part’s mechanical properties. By using both process information and acoustic information to predict mechanical properties, yield strength was predicted 18% more accurately and ductility to failure was predicted 10% more accurately than is achieved when using duplicate parts to predict part performance. Finally, individual acoustic frequencies were investigated to determine why acoustic signatures improve mechanical property predictions and the potential physical origins of these signatures. This work demonstrates how blending acoustics, process information, and machine learning can provide in-situ diagnostics of mechanical properties and improve the reliability of the PBF-LB process.

Acoustic emission↗

TU-B-19A-01: Image Registration II: TG132-Quality Assurance for Image Registration

AAPM Task Group 132 was charged with a review of the current approaches and solutions for image registration in radiotherapy and to provide recommendations for quality assurance and quality control of these clinical processes. As the results of image registration are always used as the input of another process for planning or delivery, it is important for the user to understand and document the uncertainty associate with the algorithm in general and the Result of a specific registration. The recommendations of this task group, which at the time of abstract submission are currently being reviewed by the AAPM, include the following components. The user should understand the basic image registration techniques and methods of visualizing image fusion. The disclosure of basic components of the image registration by commercial vendors is critical in this respect. The physicists should perform end-to-end tests of imaging, registration, and planning/treatment systems if image registration is performed on a stand-alone system. A comprehensive commissioning process should be performed and documented by the physicist prior to clinical use of the system. As documentation is important to the safe implementation of this process, a request and report system should be integrated into the clinical workflow. Finally, a patient specific QA practice should be established for efficient evaluation of image registration results. The implementation of these recommendations will be described and illustrated during this educational session. Learning Objectives: Highlight the importance of understanding the image registration techniques used in their clinic. Describe the end-to-end tests needed for stand-alone registration systems. Illustrate a comprehensive commissioning program using both phantom data and clinical images. Describe a request and report system to ensure communication and documentation. Demonstrate an clinically-efficient patient QA practice for efficient evaluation of image registration.

60 APPLIED LIFE SCIENCES↗

What's with all this peer-review stuff anyway?

The Journal of Physical Security was ostensibly started to deal with a perceived lack of peer-reviewed journals related to the field of physical security. In fact, concerns have been expressed that the field of physical security is scarcely a field at all. A typical, well-developed field might include the following: multiple peer-reviewed journals devoted to the subject, rigor and critical thinking, metrics, fundamental principles, models and theories, effective standards and guidelines, R and D conferences, professional societies, certifications, its own academic department (or at least numerous academic experts), widespread granting of degrees in the field from 4-year research universities, mechanisms for easily spotting 'snake oil' products and services, and the practice of professionals organizing to police themselves, provide quality control, and determine best practices. Physical Security seems to come up short in a number of these areas. Many of these attributes are difficult to quantify. This paper seeks to focus on one area that is quantifiable: the number of peer-reviewed journals dedicated to the field of Physical Security. In addition, I want to examine the number of overall periodicals (peer-reviewed and non-peer-reviewed) dedicated to physical security, as well as the number of papers published each year about physical security. These are potentially useful analyses because one can often infer how healthy or active a given field is by its publishing activity. For example, there are 2,754 periodicals dedicated to the (very healthy and active) field of physics. This paper concentrates on trade journal versus peer-reviewed journals. Trade journals typically focus on practice-related topics. A paper appropriate for a trade journal is usually based more on practical experience than rigorous studies or research. Models, theories, or rigorous experimental research results will usually not be included. A trade journal typically targets a specific market in an industry or trade. Such journals are often considered to be news magazines and may contain industry specific advertisements and/or job ads. A peer-reviewed journal, a.k.a 'referred journal', in contrast, contains peer-reviewed papers. A peer-reviewed paper is one that has been vetted by the peer review process. In this process, the paper is typically sent to independent experts for review and consideration. A peer-reviewed paper might cover experimental results, and/or a rigorous study, analyses, research efforts, theory, models, or one of many other scholarly endeavors.

99 GENERAL AND MISCELLANEOUS↗