Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “QUALITY FACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Quality and Loss Factor Characterization of YBCO Superconducting Transmission Lines for Axion Dark Matter Detection

Axion haloscope experiments aim to detect the conversion of axions into microwave photons under a strong magnetic field through resonant cavity techniques. The conversion produces an extremely small signal, requiring a cryogenic environment to reduce thermal noise, and low-loss superconducting transmission lines for minimal attenuation in the readout chain. Yttrium barium copper oxide (YBCO) cables are a promising candidate. Unlike commonly used low-loss cryogenic cables such as niobium (Nb) and niobium titanium (NbTi), which have low critical fields, YBCO is a high-temperature superconductor that can remain stable in strong magnetic fields. We characterized the quality and loss of five stripline resonators from the Brookhaven Technology Group: three YBCO, a copper reference, and a silver reference. Experimental methodology included collecting scattering parameter data on a vector network analyzer for the samples at 77 K along with room temperature baseline measurements, and employing both Lorentzian-fit and circle-fitting techniques to confirm the coupling regime and corroborate results. We achieved quality factors on the order of $10^3$ with corresponding loss factors on the order of $10^{-1}$ dB/m. Trends were comparable with literature data on Nb and NbTi at 4 K, which did have lower loss under these conditions, but suggested similar or perhaps better loss for YBCO when accounting for the temperature difference. We also developed a cryogenic probe for future measurements in a 14 T applied field at 30 mK. This will serve to directly evaluate YBCO's durability in magnetic fields, and we expect significantly improved performance at millikelvin temperatures.

Marinos, Z. [UCLA]↗

Space Radiation Cancer, Circulatory Disease and CNS Risks for Near Earth Asteroid and Mars Missions: Uncertainty Estimates for Never-Smokers

The uncertainties in estimating the health risks from galactic cosmic rays (GCR) and solar particle events (SPE) are a major limitation to the length of space missions and the evaluation of potential risk mitigation approaches. NASA limits astronaut exposures to a 3% risk of exposure induced cancer death (REID), and protects against uncertainties in risks projections using an assessment of 95% confidence intervals after propagating the error from all model factors (environment and organ exposure, risk coefficients, dose-rate modifiers, and quality factors). Because there are potentially significant late mortality risks from diseases of the circulatory system and central nervous system (CNS) which are less well defined than cancer risks, the cancer REID limit is not necessarily conservative. In this report, we discuss estimates of lifetime risks from space radiation and new estimates of model uncertainties are described. The key updates to the NASA risk projection model are: 1) Revised values for low LET risk coefficients for tissue specific cancer incidence, with incidence rates transported to an average U.S. population to estimate the probability of Risk of Exposure Induced Cancer (REIC) and REID. 2) An analysis of smoking attributable cancer risks for never-smokers that shows significantly reduced lung cancer risk as well as overall cancer risks from radiation compared to risk estimated for the average U.S. population. 3) Derivation of track structure based quality functions depends on particle fluence, charge number, Z and kinetic energy, E. 4) The assignment of a smaller maximum in quality function for leukemia than for solid cancers. 5) The use of the ICRP tissue weights is shown to over-estimate cancer risks from SPEs by a factor of 2 or more. Summing cancer risks for each tissue is recommended as a more accurate approach to estimate SPE cancer risks. 6) Additional considerations on circulatory and CNS disease risks. Our analysis shows that an individual s history of smoking exposure has a larger impact on GCR risk estimates than amounts of radiation shielding or age at exposure (amongst adults). Risks for never-smokers compared to the average U.S. population are estimated to be reduced between 30% and 60% dependent on model assumptions. Lung cancer is the major contributor to the reduction for never-smokers, with additional contributions from circulatory diseases and cancers of the stomach, liver, bladder, oral cavity and esophagus, and leukemia. The relative contribution of CNS risks to the overall space radiation detriment is potentially increased for never-smokers such as most astronauts. Problems in estimating risks for former smokers and the influence of second-hand smoke are discussed. Compared to the LET approximation, the new track structure derived radiation quality functions lead to a reduced risk for relativistic energy particles and increased risks for intermediate energy particles. Revised estimates for the number of safe days in space at solar minimum for heavy shielding conditions are described for never-smokers and the average U.S. population. Results show that missions to near Earth asteroids (NEA) or Mars violate NASA's radiation safety standards with the current levels of uncertainties. Greater improvements in risk estimates for never-smokers are possible, and would be dependent on improved understanding of risk transfer models, and elucidating the role of space radiation on the various stages of disease formation (e.g. initiation, promotion, and progression).

Cucinotta, Francis A.↗

Top-Performing Photovoltaic Cells Compared to the Shockley–Queisser Limit

Top-performing single-junction and two-terminal tandem devices that include at least one polycrystalline cell are compared with each other and their ideal limits. The parameters of open-circuit voltage, short-circuit current, and fill-factor are individually compared to the Shockley–Queisser limit to investigate where different technologies have room to improve. Technologies, such as silicon and cadmium telluride have the most room for improvement in open-circuit voltage currently utilizing 87% and 81% of their maxima, respectively. Detailed diode and fill-factor loss analysis is presented for single-junction devices to give further insight on how they compare and where efficiency is lost. Single-crystal technologies demonstrate a fill-factor closer to the Shockley–Queisser limit than polycrystalline devices. The high diode quality factor of polycrystalline devices is the leading cause of the decreased fill-factor. Similar analysis on tandem cells with at least one thin-film cell shows that although their efficiency exceeds that of the single-junction cells, the fraction of their ideal efficiency is smaller. Here, by comparing parameters to the Shockley–Queisser limit, it becomes clearer where certain technologies have the potential for improvement.

High efficiency↗

Low-Loss Plasmonic Dielectric Nanoresonators

Material losses in metals are a central bottleneck in plasmonics for many applications. We propose and theoretically demonstrate that metal losses can be successfully mitigated with dielectric particles on metallic films, giving rise to hybrid dielectric–metal resonances. In the far field, they yield strong and efficient scattering, beyond even the theoretical limits of all-metal and all-dielectric structures. In the near field, they offer high Purcell factor (>5000), high quantum efficiency (>90%), and highly directional emission at visible and infrared wavelengths. Their quality factors can be readily tailored from plasmonic-like (~10) to dielectric-like (~10 3 ), with wide control over the individual resonant coupling to photon, plasmon, and dissipative channels. Compared with conventional plasmonic nanostructures, such resonances show robustness against detrimental nonlocal effects and provide higher field enhancement at extreme nanoscopic sizes and spacings. These hybrid resonances equip plasmonics with high efficiency, which has been the predominant goal since the field’s inception.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Quantum nanophotonic interface for tin-vacancy centers in thin-film diamond

The negatively charged tin-vacancy center in diamond (SnV − ) is an excellent solid state qubit with optically-addressable transitions and a long electron spin coherence time at elevated (∼1.7 K). However, implementing scalable quantum nodes with high-fidelity optical readout of the electron spin state requires efficient photon emission and collection from the system. Here, in this manuscript, we report a quantum photonic interface for SnV−centers based on one-dimensional photonic crystal cavities fabricated in diamond thin films. Furthermore, we provide a rigorous description of the spontaneous emission dynamics of our system, taking into account individual contributions from both the C and D transitions of the emitter. This allows for determination of Purcell factors per transition and, by extension, the C/D branching ratio SnV− zero phonon line. We observe quality factors up to ~6000 across this sample, and measure up to a 12-fold lifetime reduction, which translates into a Purcell factor of 𝐹 𝐶 =26.2±1.5 for a targeted C transition. By considering the cavity mode polarization alignment with the C and D transition dipole moments, we validate the C/D branching ratio to be 𝜂 BR =0.75±0.01, in line with previous theoretical and experimental findings.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Strategies for mitigating residual magnetic field effect on pre-production PIP-II SSR2 cryomodule performance

This paper outlines the strategy aimed at mitigating the adverse effects of residual magnetic fields on the performance of pre-production SSR2 superconducting cavities within the context of the PIP-II project at Fermilab. Residual magnetic fields can significantly impact cavity performance, leading to reduced quality factor. To address this challenge, our strategy integrates various approaches including magnetic shielding, careful selection of materials, quality controls aimed at measuring magnetic permeability, magnetic hygiene to reduce residual magnetic field at the installation phase. Additionally, experimental studies are being planned to analyze the behavior of the cavities under different magnetic field conditions, and the effectiveness of advanced demagnetization procedures.

43 PARTICLE ACCELERATORS↗

Observation of interface piezoelectricity in superconducting devices on silicon

The development of superconducting quantum processors relies on understanding and mitigating decoherence in superconducting qubits. Piezoelectric coupling contributes to decoherence by mediating energy exchange between microwave photons and acoustic phonons. Although bulk centrosymmetric materials like silicon and sapphire are non-piezoelectric and commonly used as qubit substrates, the lack of centrosymmetry at interfaces may induce piezoelectric losses. This effect was predicted decades ago but never experimentally observed in superconducting devices. Here, we report interface piezoelectricity at aluminum-silicon junctions and demonstrate it as a significant loss channel in superconducting devices. Using aluminum interdigital transducers on silicon, we observe piezoelectric transduction from room to millikelvin temperatures, with an effective electromechanical coupling factor K 2 ≈ (3 ± 0.4) × 10−5%, comparable to weakly piezoelectric substrates. Modeling shows this mechanism limits qubit quality factors to Q ~ 10 4 − 10 8 , depending on surface participation and mode matching. These findings reveal interface piezoelectricity as a major dissipation channel and highlight the need for heterostructure and phononic engineering in next-generation superconducting qubits.

Zhou, Haoxin [University of California, Berkeley, ↗

Lumped elements characterize Q in dielectric resonators

It has been earlier observed (Podcameni et al., 1981) that, as the coupling factor between a microstrip-coupled dielectric resonator and the line becomes much larger than unity, the unloaded quality factor (Q) of the resonator decreases. In this paper it is shown that this effect can be explained using lumped-element models of the coupling line, when the dielectric resonator is either overcoupled or undercoupled to the line.

Hearn, Chase P.↗

Comparisons of LET distributions measured in low-earth orbit using tissue-equivalent proportional counters and the position-sensitive silicon-detector telescope (RRMD-III)

Determinations of the LET distribution, phi(L), of charged particles within a spacecraft in low-Earth orbit have been made. One method used a cylindrical tissue-equivalent proportional counter (TEPC), with the assumption that for each measured event, lineal energy, y, is equal to LET and thus phi(L) = phi(y). The other was based on the direct measurement of LETs for individual particles using a charged-particle telescope consisting of position-sensitive silicon detectors called RRMD-III. There were differences of up to a factor of 10 between estimates of phi(L) using the two methods on the same mission. This caused estimates of quality factor to vary by a factor of two between the two methods.

Flight Experiment↗

Radiation measurements on the Mir Orbital Station

Radiation measurements made onboard the MIR Orbital Station have spanned nearly a decade and covered two solar cycles, including one of the largest solar particle events, one of the largest magnetic storms, and a mean solar radio flux level reaching 250 x 10(4) Jansky that has been observed in the last 40 years. The cosmonaut absorbed dose rates varied from about 450 microGy day-1 during solar minimum to approximately half this value during the last solar maximum. There is a factor of about two in dose rate within a given module, and a similar variation from module to module. The average radiation quality factor during solar minimum, using the ICRP-26 definition, was about 2.4. The drift of the South Atlantic Anomaly was measured to be 6.0 +/- 0.5 degrees W, and 1.6 +/- 0.5 degrees N. These measurements are of direct applicability to the International Space Station. This paper represents a comprehensive review of Mir Space Station radiation data available from a variety of sources. c2002 Elsevier Science Ltd. All rights reserved.

Mir Project↗

Effective dose equivalent on the ninth Shuttle--Mir mission (STS-91)

Organ and tissue doses and effective dose equivalent were measured using a life-size human phantom on the ninth Shuttle-Mir Mission (STS-91, June 1998), a 9.8-day spaceflight at low-Earth orbit (about 400 km in altitude and 51.65 degrees in inclination). The doses were measured at 59 positions using a combination of thermoluminescent dosimeters of Mg(2)SiO(4):Tb (TDMS) and plastic nuclear track detectors (PNTD). In correcting the change in efficiency of the TDMS, it was assumed that reduction of efficiency is attributed predominantly to HZE particles with energy greater than 100 MeV nucleon(-1). A conservative calibration curve was chosen for determining LET from the PNTD track-formation sensitivities. The organ and tissue absorbed doses during the mission ranged from 1.7 to 2.7 mGy and varied by a factor of 1.6. The dose equivalent ranged from 3.4 to 5.2 mSv and varied by a factor of 1.5 on the basis of the dependence of Q on LET in the 1990 recommendations of the ICRP. The effective quality factor (Q(e)) varied from 1.7 to 2.4. The dose equivalents for several radiation-sensitive organs, such as the stomach, lung, gonad and breast, were not significantly different from the skin dose equivalent (H(skin)). The effective dose equivalent was evaluated as 4.1 mSv, which was about 90% of the H(skin).

NASA Center JSC↗

Optically Thin Metallic Films for High-Radiative-Efficiency Plasmonics

Plasmonics enables deep-subwavelength concentration of light and has become important for fundamental studies as well as real-life applications. Two major existing platforms of plasmonics are metallic nanoparticles and metallic films. Metallic nanoparticles allow efficient coupling to far field radiation, yet their synthesis typically leads to poor material quality. Metallic films offer substantially higher quality materials, but their coupling to radiation is typically jeopardized due to the large momentum mismatch with free space. We propose and theoretically investigate optically thin metallic films as an ideal platform for high-radiative-efficiency plasmonics. For far-field scattering, adding a thin high-quality metallic substrate enables a higher quality factor while maintaining the localization and tunability that the nanoparticle provides. For near-field spontaneous emission, a thin metallic substrate, of high quality or not, greatly improves the field overlap between the emitter environment and propagating surface plasmons, enabling high-Purcell (total enhancement >10 4 ), high-quantum-yield (>50%) spontaneous emission, even as the gap size vanishes (3–5 nm). The enhancement has almost spatially independent efficiency and does not suffer from quenching effects that commonly exist in previous structures.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A Hybrid Molecular–Nanophotonic Platform for On-Chip Cavity Quantum Electrodynamics and Collective Interactions

We present a hybrid solid-state cavity quantum electrodynamics (QED) platform that integrates a high density of coherent organic molecules with high-quality-factor nanophotonics. Thin anthracene crystals doped with dibenzoterrylene (DBT) are mechanically transferred onto prefabricated silicon nitride photonic crystal cavities, preserving both the cavity quality and molecular coherence. This approach decouples emitter synthesis from nanofabrication, providing a pathway for integrating other types of emitters. The high density of molecular emitters results in up to ten molecules being coupled to a single cavity. By tuning pairs of molecules into resonance within a single cavity mode, we observe cavity-mediated interactions in both dispersive and dissipative regimes. Furthermore, these results establish an accessible route to deterministic on-chip single- and multiphoton sources.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Dose equivalent near the bone-soft tissue interface from nuclear fragments produced by high-energy protons

During manned space missions, high-energy nucleons of cosmic and solar origin collide with atomic nuclei of the human body and produce a broad linear energy transfer spectrum of secondary particles, called target fragments. These nuclear fragments are often more biologically harmful than the direct ionization of the incident nucleon. That these secondary particles increase tissue absorbed dose in regions adjacent to the bone-soft tissue interface was demonstrated in a previous publication. To assess radiological risks to tissue near the bone-soft tissue interface, a computer transport model for nuclear fragments produced by high energy nucleons was used in this study to calculate integral linear energy transfer spectra and dose equivalents resulting from nuclear collisions of 1-GeV protons transversing bone and red bone marrow. In terms of dose equivalent averaged over trabecular bone marrow, target fragments emitted from interactions in both tissues are predicted to be at least as important as the direct ionization of the primary protons-twice as important, if recently recommended radiation weighting factors and "worst-case" geometry are used. The use of conventional dosimetry (absorbed dose weighted by aa linear energy transfer-dependent quality factor) as an appropriate framework for predicting risk from low fluences of high-linear energy transfer target fragments is discussed.

NASA Discipline Number 45-10↗

Acoustical properties of highly porous fibrous materials

Highly porous, fibrous bulk sound absorbing materials are studied with a view toward understanding their acoustical properties and performance in a wide variety of applications including liners of flow ducts. The basis and criteria for decoupling of acoustic waves in the pores of the frame and compressional waves in the frame structure are established. The equations of motion are recast in a form that elucidates the coupling mechanisms. The normal incidence surface impedance and absorption coefficient of two types of Kevlar 29 and an open celled foam material are studied. Experimental values and theoretical results are brought into agreement when the structure factor is selected to provide a fit to the experimental data. A parametric procedure for achieving that fit is established. Both a bulk material quality factor and a high frequency impedance level are required to characterize the real and imaginary part of the surface impedance and absorption coefficient. A derivation of the concepts of equivalent density and dynamic resistance is presented.

Lambert, R. F.↗

Kansas environmental and resource study: A Great Plains model. Monitoring fresh water resources

The author has identified the following significant results. Processing and analysis of CCT's for numerous ground truth supported passes over Kansas reservoirs has demonstrated that sun angle and atmospheric conditions are strong influences on water reflectance levels as detected by ERTS-1 and can suppress the contributions of true water quality factors. Band ratios, on the other hand, exhibit very little dependence on sun angle and sky conditions and thus are more directly related to water quality. Band ratio levels can be used to reliably determine suspended load. Other water quality indicators appear to have little or no affect on reflectance levels.

Yarger, H. L.↗

Characterization and reduction of microfabrication-induced decoherence in superconducting quantum circuits

Many superconducting qubits are highly sensitive to dielectric loss, making the fabrication of coherent quantum circuits challenging. To elucidate this issue, we characterize the interfaces and surfaces of superconducting coplanar waveguide resonators and study the associated microwave loss. We show that contamination induced by traditional qubit lift-off processing is particularly detrimental to quality factors without proper substrate cleaning, while roughness plays at most a small role. Aggressive surface treatment is shown to damage the crystalline substrate and degrade resonator quality. We also introduce methods to characterize and remove ultra-thin resist residue, providing a way to quantify and minimize remnant sources of loss on device surfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Theoretical Investigation of the Input Characteristics of a Rectangular Cavity-Backed Slot Antenna

Equations which represent the magnetic and electric stored energies are derived for an infinite section of rectangular waveguide and a rectangular cavity. These representations which are referred to as being physically observable are obtained by considering the difference in the volume integrals appearing in the complex Poynting theorem. It is shown that the physically observable stored energies are determined by the field components that vanish in a reference plane outside the aperture. These physically observable representations are used to compute the input admittance of a rectangular cavity-backed slot antenna in which a single propagating wave is assumed to exist in the cavity. The slot is excited by a voltage source connected across its center; a sinusoidal distribution is assumed in the slot. Input-admittance calculations are compared with measured data. In addition, input-admittance curves as a function of electrical slot length are presented for several size cavities. For the rectangular cavity backed slot antenna, the quality factor and relative bandwidth were computed independently by using these energy relationships. It is shown that the asymptotic relationship which is usually assumed to exist between the quality bandwidth and the reciprocal of relative bandwidth is equally valid for the rectangular cavity backed slot antenna.

Cockrell, C. R.↗