Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pumped Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Hanford Direct Feed Low Activity Waste Program Throughput Optimization Through Modeling - 18587

The Direct Feed Low Activity Waste (DFLAW) program at Hanford allows for the early treatment of tank wastes years earlier than previously planned. Operational Research (OR) modeling is being used to provide invaluable insight into how complex and integrated processes will operate. The DFLAW OR models are used to help optimize the design and operation of the integrated system. The DFLAW OR models include the processes and real-life complexities involved in the day-to-day operation of the systems and equipment, and can predict key performance characteristics including throughput, mission timescale, equipment and labor utilization, lag storage and capacity requirements. The DFLAW OR models also have the in-built capability to simulate random events such as equipment failures. Adding random variability to models introduces a real-life element to model results. For example, OR modeling breakdown analysis of equipment failure and restoration times may inform specific improvements to a design and plant operation, including areas where the provision of spare (duty/standby) equipment would prove beneficial; the optimum number and capacity of lag storage tanks (for waste intermediate storage, reagents, etc.); operational issues, including scheduling constraints, labor resource constraints, effect of shift schedules (e.g. days only, extended shifts, 24/7),, maintenance strategies, including planned maintenance, equipment upgrades, on-hand spare part stockholding, etc. At Hanford, standalone OR models to date, have been used to help identify key operational issues and improve the design and operation of individual systems within the Tank Farms, Low Activity Waste Pretreatment System (LAWPS), Low Activity Waste (LAW) Vitrification and Effluent Management Facility (EMF) and Integrated Disposal Facility (IDF), logistics and infrastructure, 222-S laboratory [References 1 and 2] including: - Identification of critical spares including transfer pumps; - Underpin size and number of lag storage tanks to maintain continuous LAW feed to the LAW melters; - Underpin sample turnaround times at the 222-S Laboratory (e.g. feed prequalification and evaporator campaign samples) and determine how targets can be achieved without impacting waste feed delivery to LAWPS and the LAW Vitrification Facility; - Determine operational strategy required at IDF including shift schedules and sizes and the number of ILAW transporters that can support DFLAW throughput; - Identification of lag storage management strategies for glass formers, reagents, other consumables due to delivery distance and delays due to bad weather; and - Truck delivery badging needs to support 24/7 operation and management of shift in/out times required to reduce congestion. An Integrated DFLAW OR model has been developed and combines the standalone OR models such that integrated throughput and availability can be assessed from a program perspective. The Integrated OR model will provide a more detailed understanding of the interactions between Tank Farms, LAWPS, LAW VIT and IDF such that key bottleneck areas can be identified and ensure improvements are focused. Examples of future improvements that may be considered include identification of critical spare parts, required on-site maintenance capabilities, shift scheduling, and craft and labor availability. The methods, results and insights derived by DFLAW OR modeling efforts are expected to provide useful applications to other projects that involve combinations of mechanical handling, chemical processing, waste treatment/packaging or environmental remediation operations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NASA Redox cell stack shunt current, pumping power, and cell performance tradeoffs

The NASA Redox energy storage system is under active technology development. The hardware undergoing laboratory testing is either 310 sq. cm. or 929 sq. cm. (0.33 sq. ft. or 1.0 sq. ft. per cell active area with up to 40 individual cells connected to make up a modular cell stack. This size of hardware allows rather accurate projections to be made of the shunt power/pump power tradeoffs. The modeling studies that were completed on the system concept are reviewed along with the approach of mapping the performance of Redox cells over a wide range of flow rates and depths of discharge of the Redox solutions. Methods are outlined for estimating the pumping and shunt current losses for any type of cell and stack combination. These methods are applicable to a variety of pumping options that are present with Redox systems. The results show that a fully developed Redox system has acceptable parasitic losses when using a fixed flow rate adequate to meet the worst conditions of current density and depth of discharge. These losses are reduced by about 65 percent if variable flow schedules are used. The exact value of the overall parasitics will depend on the specific system requirements of current density, voltage limits, charge, discharge time, etc.

Hagedorn, N.↗

DOE Cold Climate Heat Pump Challenge Field Validation: Data Collection and Analysis Plan

This document details the data collection, storage, and analysis plan and methodologies for conducting the field validation portion of DOE’s Cold Climate Heat Pump (CCHP) Challenge. The study is focused on validating the in-field heating performance of prototypical CCHPs that have successfully demonstrated that they meet or exceed the Challenge specification in a laboratory setting. The units that have passed laboratory testing will be installed in real homes along with sensors and loggers for monitoring performance over an entire heating season. Data collected through monitoring will be cleaned and stored in a secure database. The data will be analyzed for calculating the key metrics defined by the Challenge including heating capacities at low outdoor air temperatures (below 32 °F), efficiency in terms of the Coefficient of Performance (COP), switchover temperatures and auxiliary heat staging. Demand Response (DR) capabilities will also be tested using specially designed DR events. In most cases, shoulder season and cooling season performance will also be determined and reported.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Turbopump thermodynamic cooling

System for cooling turbopumps used in cryogenic fluid storage facilities is described. Technique uses thermodynamic propellant vent to intercept pump heat at desired conditions. Cooling system uses hydrogen from outside source or residual hydrogen from cryogenic storage tank.

Patten, T. C.↗

High Toughness Cermets for Molten Salt Pumps

Concentrated Solar Power plants using nitrate salts used cantilevered pump designs to avoid use of bearings in the 565°C salt; however, this necessitated the use of a sump that added additional cost, complexity, and thermal losses. Sump systems had their own complications, including risk of flooding the sump due to control issues either with level indicators or failures in the control valve responsible for filling the sump. Long-shafted pumps were developed and tested, and they outline the need to develop journal sleeves and bearings for new salt systems. Based on reports, pumps will need to be a vertical single- or multi-stage type, mounted to the roof of the molten salt tanks. Design and service for molten salt pumps above 550°C is relatively limited, and at temperatures up to 750°C there is no available design or service experience. Long-shaft pumps that extend to the bottom of the thermal energy storage tank will require bearing materials that are suitable to the given salt chemistry. Lubricity of proposed salts is unclear and need to be determined, especially for cold-tank pumps that require multi-stages for lifting the salt to the top of the tower. Materials, design, and maintenance are all major unknowns.

14 SOLAR ENERGY↗

Solar heating, cooling, and hot water systems installed at Richland, Washington

The project described is part of the U. S. Department of Energy's solar demonstration program, and became operational in April 1978. The solar system uses 6,000 square feet of flat-plate liquid collectors in a closed loop to deliver solar energy through a liquid-liquid heat exchanger to the building heat-pump duct work or 9,000-gallon thermal energy storage tank. A 25-ton Arkla solar-driven absorption chiller provides the cooling, in conjunction with a 2,000 gallon chilled water storage tank and reflective ponds on three sides of the building surplus heat. A near-by building is essentially identical except for having conventional heat-pump heating and cooling, and can serve as an experimental control. An on-going public relations program was provided from the beginning of the program, and resulted in numerous visitors and tour groups.

Source record↗

Experimental Evaluation of Thermal Storage Performance of a Dual-Purpose Underground Thermal Battery

A geothermal heat pump (GHP) system is an energy-efficient building heating and cooling technology with great potential for reducing energy consumption and decarbonization. However, applications of GHP are still limited due to the high cost, of which 30% is related to the cost of installing the conventional vertical bore ground heat exchangers, which are usually installed in boreholes 60 meters deep. A dual-purpose underground thermal battery (DPUTB) has been developed to offer a low-cost ground heat exchanger with a built-in thermal storage capacity. The DPUTB innovatively integrates a shallow-bore ground heat exchanger (the outer tank), which can be installed in a borehole less than 6 m deep, with thermal energy storage (TES) (the inner tank). DPUTB has the potential to reduce the cost of a ground source heat pump system while allowing shifting the electric demand of the building served by the GHP system from peak to off-peak hours of the electric grid by charging and discharging the thermal storage. A lab-scale (1:125 in volume) DPUTB prototype was built. Phase change material (PCM) was added to increase the thermal storage capacity and maintain the supply water temperature from the TES within the desired range for direct cooling operation during the discharge period. As PCMs are critical to the TES performance of the DPUTB, this study compared the influence of different PCMs (including salt hydrate and organic PCMs) on the discharge performance of the DPUTB. The thermal State of Charge (SoC) of the DPUTB was used to compare the performance resulting from using different PCMs. Test results indicate that the organic PCM (Methyl Laurate) outperforms salt-hydrate PCMs due to a lower melting temperature and a narrower melting temperature range during the phase change process. The results of this study provide a guide for PCM selection and the optimal design of DPUTB.

Wang, Lingshi↗

Angularly quantized spin rotations in hexagonal LuMnO 3

Optical control of the spin degree of freedom is often desired in application of the spin technology. Here we report spin-rotational excitations observed through inelastic light scattering of the hexagonal LuMnO 3 in the antiferromagnetically (AFM) ordered state. We propose a model based on the spin–spin interaction Hamiltonian associated with the spin rotation of the Mn ions, and find that the spin rotations are angularly quantized by 60°, 120°, and 180°. Angular quantization is considered to be a consequence of the symmetry of the triangular lattice of the Mn-ion plane in the hexagonal LuMnO 3 . These angularly-quantized spin excitations may be pictured as isolated flat bubbles in the sea of the ground state, which may lead to high-density information storage if applied to spin devices. Optically pumped and detected spin-excitation bubbles would bring about the advanced technology of optical control of the spin degree of freedom in multiferroic materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Solar heating and hot water system installed at Southeast of Saline, Unified School District 306, Mentor, Kansas

The solar system, installed in a new building, was designed to provide 52 percent of the estimated annual space heating load and 84 percent of the estimated annual potable hot water requirement. The liquid flat plate collectors are ground-mounted and cover a total area of 5125 square feet. The system will provide supplemental heat for the school's closed-loop water-to-air heat pump system and domestic hot water. The storage medium is water inside steel tanks with a capacity of 11,828 gallons for space heating and 1,600 gallons for domestic hot water. The solar heating facility is described and drawings are presented of the completed system which was declared operational in September 1978, and has functioned successfully since.

Source record↗

Residential Photovoltaic/Thermal Energy System

Proposed system supplies house with both heat and electricity. Pair of reports describes concept for self-sufficient heating, cooling, and power-generating system for house. Panels on walls of house provide hot water, space heating, and heat to charge heat-storage system, and generate electricity for circulation pumps and fans. Roof panels generate electricity for household, operate heat pump for summer cooling, and provide supplementary winter heating via heat pump, using solar-cell cooling-fluid loop. Wall and roof panels used independently.

Selcuk, M. K.↗

Environmental calibration chamber operations

Thermal vacuum capabilities are provided for the development, calibration, and functional operation checks of flight sensors, sources, and laboratory and field instruments. Two systems are available. The first is a 46 cm diameter diffusion pumped vacuum chambler of the bell jar variety. It has an internal thermal shroud, LN2 old trap, two viewing ports, and various electrical and fluid feedthroughs. The other, also an oil diffusion pumped system, consists of a 1.8 m diameter by 2.5 m long stainless steel vacuum tank, associated pumping and control equipment, a liquid nitrogen storage and transfer system and internal IR/visible calibration sources. This is a two story system with the chamber located on one floor and the pumping/cryogenic systems located on the floor below.

Lester, D. L.↗

Domestic Dishwasher Simulated Energy Efficiency Evaluation Using Thermoelectric Heat Pump for Water Heating and Dish Drying

A quasi-steady state, heat and mass transfer lumped-capacitance model was developed to predict the energy consumption and drying performance of domestic dishwashers. A numerical finite element solution was applied, assuming that the following components could each be treated as a lumped thermal capacitance: dish load, tub, wash water, and air in tub. The model was used to predict the energy consumption savings of heating water using a thermoelectric heat pump that extracts heat from a thermal storage medium, and the drying performance of circulating tub air through the cold and then hot side of TE modules.

Abuheiba, Ahmad↗

Development of an Underground Thermal Battery for Enabling Ground Source Heat Pump Applications and Shaping Electric Demand of Buildings

An innovative underground thermal battery (UTB) can provide not only a stable heat sink or heat source for efficient heat pump operation, but also a thermal energy storage to overcome the mismatch between intermittent renewable power supply and fluctuating thermal demands of a building. This article introduces the recent developments of the UTB, including concept design, lab tests, and modeling. Initial results indicate that the UTB has a potential to enable both efficient air-conditioning and active demand side management without sacrificing the desired comfort condition and convenience in the building.

25 ENERGY STORAGE↗

Case study in corporate memory recovery: Hanford tank farms miscellaneous underground waste storage tanks - 15344

In addition to managing the 177 underground waste storage tanks containing 212,000 m{sup 3} (56 million gal) of radioactive waste at the U. S. Department of Energy's Hanford Site 200 Area Tank Farms, Washington River Protection Solutions LLC is responsible for managing numerous small catch tanks and special surveillance facilities. These are collectively known as 'MUSTs' - Miscellaneous Underground Storage Tanks. The MUSTs typically collected drainage and flushes during waste transfer system piping changes; special surveillance facilities supported Tank Farm processes including post-World War II uranium recovery and later fission product recovery from tank wastes. Most were removed from service following deactivation of the single-shell tank system in 1980 and stabilized by pumping the remaining liquids from them. The MUSTs were isolated by blanking connecting transfer lines and adding weatherproofing to prevent rainwater entry. Over the next 30 years MUST operating records were dispersed into large electronic databases or transferred to the National Archives Regional Center in Seattle, Washington. During 2014 an effort to re-acquire the historical bases for the MUSTs' published waste volumes was undertaken. Corporate Memory Recovery from a variety of record sources allowed waste volumes to be initially determined for 21 MUSTs, and waste volumes to be adjusted for 37 others. Precursors and symptoms of Corporate Memory Loss were identified in the context of MUST records recovery. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Resource Adequacy and Capital Cost Considerations Pertaining to Large Electric Grids Powered by Wind, Solar, Storage, Gas, and Nuclear

The capacity and generation of wind, solar, storage, nuclear, and gas are estimated for large, idealized copper-plate electric grids. Wind and solar penetrations of 30% to 80% are considered together with different storage systems such as vanadium and lithium-ion batteries, pumped hydroelectric, compressed air, and hydrogen. In addition to a baseline dispatchable fleet without wind/solar, two bounding cases with wind/solar are analyzed: one without storage and one where the whole wind/solar fleet is connected to the storage system, hence providing a buffer between the wind/solar fleet and the grid. The reality will likely be somewhere between these bounding cases. The viability of a power grid with a large wind/solar penetration and no storage is not guaranteed but was nonetheless considered to provide a lower-bound capital cost estimate. Overall, the options that rely strongly on wind, solar, and storage could be significantly more capital-intensive than those that rely strongly on nuclear, depending on the amount of storage necessary to ensure grid stability. This is especially true in the long run because wind, solar, and storage assets have shorter lifetimes than nuclear plants and, consequently, need to be replaced more frequently. More analyses (e.g., grid stability and public acceptance) are necessary to determine which option is most likely to provide the path of least resistance to powering a clean, affordable, and reliable grid in a timely manner. Depending on the priorities, the path of least resistance may not necessarily be the one that is less capital intensive.

adequacy↗